Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance NO 305 1 NEW COLONY 2ND STREET VALLAM POST CHENGALPET 603 002 | CHENGALPET | CHENGALPET | TAMIL NADU | 603002 | Admitted-Finance |
| 4 | Admitted-Finance NO 71 1 7TH STREET PARVATHI AVENUE SAKTHI NAGAR PORUR CHENNAI 600 116 | CHENNAI | CHENNAI | TAMIL NADU | 600116 | Admitted-Finance |
Tender Value
₹45.6 L
EMD Value
₹46,000
Closing Date
10 May 2023, 3:00 pmClosed
Block Development officer(BP),Kattankolathur
Block Development office,Kattankolathur
Construction of Open Well, Pump Room and Providing Submersible Pumpset to the Murugamangalam Habitation in Keerapakkam Village Panchayat in Kattankolathur Panchayat Union in Chengalpattu District under TNUHDB 2022-23 Funds
2023_RDTN_305327_1
5639/2022/A12 Date 22.04.2023
Open Tender
Civil Works
Item Rate
90 days
Block Development office, Kattankolathur
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹46,000
Yes
29 May 2023
22 Apr 2023
10 May 2023
22 Apr 2023
10 May 2023
22 Apr 2023
Amount
Earth work open well excavation, complying with relevant clauses of T.N.D.S.S. Well sinking and with lead upto 10 metres in Hard stiff clay, stiff black cotton soil, hard red earth, shales,murrams gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil - First depth of 2 metres
Earth work open well excavation, complying with relevant clauses of T.N.D.S.S. Well sinking and with lead up to 10 metres in soft disintegrated rock, laterite, soft rock or kankar, not requiring blasting. II nd Depth 2.00m to 4.00m below GL
III rd Depth 4.0m to 6.00m below GL
Open well excavation, complying with relevant clauses of T.N.D.S.S. Well sinking and with lead up to 10m in Medium rock and Dense medium rock not requiring blasting. IV th depth 6.00 to 8.00m below GL
Open well excavation complying with relevant clauses of T.N.D.S.S. well sinking and with lead up to 10m in Medium rock and Dense medium rock requiring blasting. V th depth 8.00 to 10.00m Below GL
Open well excavation complying with relevant clauses of T.N.D.S.S. well sinking and with lead up to 10m in hard granite measured in solid including blasting and stacking. VI th depth 10.00 to 12.00m Below GL
VII th Depth 12.00 to 14.00m below GL
VIII th Depth 14.00 to 15.00m below GL
Cement Concrete 1:4:8 mix using 40mm ISS metal with cost and conveyance incluidng all other labour charges etc complete
Randam Rubble Masonary in CM1:5 mix using rough stones including cost and conveyance and all other labour charges etc complete.
Openwell steining wall above GL & below 1.50m
Openwell steining wall 1.50 to 4.50m below GL
Openwell steining wall 4.50 to 9.00m below GL
R.C.C 1:1.5:3 mix using 20mm ISS HBG meral including cost and conveyance and all other labour charges etc complete.
Ring Beam at GL(0 to 1.50m Below GL)
1.50m to 4.5m below GL
Ring Beam at 4.50 to 6.00m Below GL
Centering with shuttering for all cc works using mS Sheet including all other charges etc complete
Plane Surface Upto 3.30m HT
Curved Surface Upto 3.30m HT
Casting of Precast RCC Cover Slab of size 1.20mX0.45mX0.075m using 20mm hard broken stone jelly,lifting and fixing in position over the well including cost and conveyance and all other labour charges etc complete.
Supplying and fabrication of steel including cost and conveyance and all other labour charges etc complete.
Bailing out of water by hiring diesel pumpset upto 5HP including cost and conveyance and all other labour charges etc complete.
Refilling the outside of the well with excavated earth complying with standard specification for filling the foundation including watering etc complete
Pointing with Cement mortar 1:3 for R.R Masonry inclduing cost of all materials,labour charges curing etc complete
Provision ventilating arrangement with 110 PVC Cowl with mosquito net as per standard specification
white washing two coats using fine screened shell lime etc
Applying two coats of cement paint of approved colour and quality over cement plastered well etc
painting of TWAD Emblem for openwell etc
Provision for Geophysical investigation charges
provision for water analytical charges
Supply and Delivery Erection and testing of openwell type Submersible Pumpsets with accessories.
Supply and delivery and erection of Submersible Pumpset of 202 lpm X 66m Head,7.50HP.
Supply and delivery of fully automatic transformer starter suitable for the motor offered. Floor mounting type air/oil cooled auto transformer Starter with tapings at 50%,60%,80%,housed tobust steel chamber with arc and main contacts confirming ti IS 8544 part IV and amended thereafter for operation in AC three phase 50Hz with the following componenets etc
Supply,delivery of 1.1 KV grade PVC insulated and sheathed 3 core flat copper cable with iSI marking etc complete 6.00 Sq.mm copper cable
Supply,delivery of 1.1 KV grade PVC insulated and sheathed 3 core flat copper cable with iSI marking etc complete 16 Sq.mm armoured aluminium conductor cable
Laying of 16 Sq.mm armoured aluminium conductor cable below GL including earth work excavation and refilling the trench after the cable etc
Laying of 16 Sq.mm armoured aluminium conductor cable in trenches inside the pumproom or in air etc
Supply and delivery of GI Medium class pipes and specials as per IS as listed below.
50mm GI Pipe
50mm GI Coupling Heavy
50mm GI Bend Heavy
50mm GI Flangeset Heavy
50mm MS Clampset Heavy
50mm GM Non return Valve
50X65mm GI coupler
75m PVC T.Coupler
50mm Ball valver/GM gate Valve
75mm HDPE Tee
Lighting the pumproom including internal wiring with switch circute fuses etc
40W box type tubelight
100w Bulb with angle holder
100w bulk head fittings
5Amps 3pin socket with switch
5Amps switches for light
Providing lighting wiring using MS conduit pipes and specials with 2 runs 1.5 sq.mm PVC copper wire and 1 run 12swg GI wire for earthing for light,fans etc
Obtaining power supply including cost of following materials and by engaging B license holder. EB fee for application form and deposit amount will be borne by the board.
i. Aerial fuse board of size 15X10X6cm with 32A aeerial fuse carrier
ii. Wall mounting type MS cubial EB meter box with fuse carrier
iii. Supply and laying of 7/20 size PVC insulator copper conductor cable from fuse to EB supply point etc
25mm dia GI Pipes for service point
25mm dia GI elbow
No. 8 GI wire for earth
stay wire
20mm GI Pipe foe twin earthing and cable encasing
4 way nutural link
TW panel board(41 X 31X 6cm)
labour Charges for erection of submersible pumpset including fixing and jointing the submersible cable with clamps to the required depth,valves and erection panel board control room twin earthing as per I.E rules etc
Construction of Pumproom
Earthwork excavation and depositing on bank with an initial lead of 10m and initial lift of 2m etc complete
Supplying and filling in foundation and basement with filling sand including water consolidating etc.,
Cement Concrete 1:4:8 mix using 40mm ISS metal with cost and conveyance incluidng all other labour charges etc complete
Randam Rubble Masonary in CM1:5 mix using rough stones including cost and conveyance and all other labour charges etc complete.
Brick work in cement mortar 1:5 using country bricks of size 83/4"x41/4"x23/4" etc., complete
Reinforced cement concrete 1:1.5:3 mix using 20mm iSs metal including all other labour charges etc complete upto GL
Reinforced cement concrete 1:1.5:3 mix using 20mm iSs metal including all other labour charges etc complete Above GL
Centering with shuttering for all cc works using mS Sheet including all other charges etc complete Upto GL
Centering with shuttering for all cc works using mS Sheet including all other charges etc complete Above GL
Plastering with CM 1:5 mix of 12mm thick including all other labour charges etc complete
Pointing with CM 1:3 for RR masonry including all other labour charges etc complete
Supplying and fabrication of steel including cost and conveyance and all other labour charges etc complete.
Floor finishing with CM 1:3 20mm thick including cost and conveyance and all other labour charges etc complete.
Special ceiling plastering with CM 1:3,10mm thick including cost and conveyance and all other labour charges etc complete.
white washing two coats using fine screened shell lime etc
Colour washing two coats with approved colour and quantity over two coats of white washing for outside of the room etc
Supplying and fixing of steel doors two leaves including all cost with filling etc
Supplying and fixing of steel windows two leaves including all cost with filling etc
Painting the doors,windows and ventilators on both sides with ready mixed enamel paint two coats over priming coat of approved quality and colour etc
Weathering course concrete using 20mm broken brick jelly in pure slacked lime including all other labour charges etc complete
Terrace flooring with two course of flat tiles using of size 200mm X 200mm X20mm laid in CM 1:3 mixed with crude oil to10% by weight of cement and pointed neatly by with the same oiled mortoe etc
Refilling wioth excavated earth complying with standard specifications for filling the foundations including watering and consolidation etc
Provision for RCC Cubboard
Provision for Levelling the site
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}18%
Ellappan contractor
DHANALAKSHMI
M.RAMARAJ
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .