Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹21.7 LAccepted-AOC | L-1 | Accepted-AOC Being the lowest bidder | |
| 2 | L-2₹30.5 L+₹6.7 L (28.1%)Rejected-AOC JAMMU PYRAMID CONSTRUCTIONS SAINIK COLONY JAMMU JAMMU 29 SECTOR SAINIK COLONY JAMMU JAMMU KASHMIR 180011 | JAMMU | JAMMU AND KASHMIR | 180011 | L-2 | Rejected-AOC Not being the lowest bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical No experience certificate of similar nature of work as per NIT conditions provided |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
24 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SANGRAM SINGH
GE Kaluchak Pin-900673 C/o 56 APO
REPAIR REPLACEMENT OF HOT COLD WEATHER APPLIANCES AND CONNECTED WORKS UNDER GE KALUCHAK
2020_MES_390593_1
GE/KC/NIT-55/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹50,000
Yes
15 Jan 2021
28 Oct 2020
26 Nov 2020
28 Oct 2020
24 Nov 2020
12 Nov 2020
28 Oct 2020 - 11 Nov 2020
60 days
Amount
E/M Portion
FANS Taking down carefully ceiling fans at any height of any sweep/ make /model after disconnecting electric connection and dismantling and opening the body of ceiling fan and examine for repairs including servicing,overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as split pins,cater pins,coupling bolt, capacitor holder,terminal adoptor, screws, nuts, spring washers for blade /body etc and replacement of components /accessories such as ball bearings, gun metal bushes, capacitor, canopy top & bottom, shackle clip assembly and assembling of all parts, remetalling of worn out shaft of fan cutting brazing machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the engineer in charge to ensure smooth and noise free operation(bearing shall be measured and paid seperately) including hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance complete all as specified and directed.
Note:- (i) Spare parts will be measured and paid separately under relevant item of schedule as supply only. (ii) Rewinding of fan motor,painting will be measured and paid separetly under relevant item of schedule. (iii) Labour element for fixing of spare parts and removing old unserviceable items are deemed to be included in quoted rate. (iv) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (v) Minimum two technicians (one Electrician and one plumber ) and two helper with all types of tools and plants/vehicle etc should report to E/M yard at 9am hrs in all working days and sundays / holidays for repair of fans including taking down / fixing of same. (vi) Repair works of fans should completed and refixed the same within 12 hours after receipt of complaint slip.If the complaint not attended /not completed on same day recovery will be done from RAR bill as follows: a) For first day Rs 200 b) For second day Rs 300 c) For next every day Rs 500.
All as per Srl item No. 1 above but for exhaust fans of 300mm/450mm sweep.
Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the ceiling fan (1200mm / 1400mm sweep) armature with new super enamelled copper wire of existing gauge including supply and fixing necessary E Class insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed.
Material and labour for rewinding of heavy duty exhaust fan motor of 300 mm sweep of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns and assembling of fan motor and rotor and testing including removing burnt out copper winding wire from fan motor complete all as specified and directed.
Material and labour for rewinding of heavy duty Exhaust fan motor 450 mm sweep sweep of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns as existing,including cleaning the motor properly and applying varnishing heating and assembling of fan motor and rotor fixing back after testing including removing burnt out copper winding wire from air circulator fan motor complete all as specified and directed.
Supply only gun metal bush suitable for ceiling fan/ exhaust fan/ air circulator fan/ wall mounted fan of any sweep/ type /size, complete all as specified & directed. Make. TATA/ MSP.
Supply only Ball bearing No. 6201/ 6202/ 6203/ 6204 for ceiling fan, complete all as specified & directed. Make. TATA/ SKF/ NBC/ NRB.
Supply only fan condensor of 2.5 MFD, complete all as specified & directed. Make. USHA/ UNIVERSAL/ Havells.
Supply only fan condensor of 3.15 MFD, complete all as specified & directed. Make. USHA/ UNIVERSAL/ Havells.
Supply only Electronic fan regulator stepped type with five step, two module, 100 Watt 240 volts complete all as directed.
Supply only PVC insulated flexible multistranded copper wire, three core of size 0.75 sqmm, complete all as specified & directed. Make. Havells/ Plaza/ Polycab.
Supply only PVC connector 4 way 6Amp with connection screws nuts etc complete all as directed.
Supply only PVC canopy set of two pieces for ceiling fans of any size complete all as directed.
Supply only rubber reel with nuts bolts clamp and washers of suitable size for ceiling fan complete all as specified and as directed.
Supply only louver shutter made of MS sheet metal 1.2mm thick for round base and 0.8 mm thick for flaps comprising of mounting legs frames made of MS flat strips of size 25mm x 3mm including heavy duty rust proof passivated bolts of size 50 mm long 8mm dia to be fixed on wall complete with using fastner bolt, drilling and duly painted by two coat of synthertic enamelled paint (spray painting ) over a coat of primer for exhaust fan up to 400 mm sweep incl taking down old one complete all as directed by the Enhineer in charge.
Cutting the wall surface of brick/stone masonry and making round hole at any height, suitable for fixing 300 mm to 450 mm sweep exhaust fan including providing nut, bolt and washers and including providing MS jali made of 3 mm dia MS wire, 5 cm apreature fixed with and including proper wooden frame, fixed at outer surface of wall and making good the disturbed surface complete all as specified and directed.
Supply only down rod made of MS pipe medium grade 15mm bore of 900mm long including drilling hole both ends & making slot in one end for fixing of ceiling fan of any sweep/type including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply, hanging and testing of BEE 1 star rated energy efficient ceiling fan with double ball bearing, 1200mm (48 inch) sweep, having 3 blades, down rod, canopies, shackles, 230volt, single phase suitable for input voltage range140-285 volt AC, 50Hz, higher, air delivery minimum 230 cu metre/min or more power consumption maximum 60 watt or lower, top speed minimum 340rpm or higher, speed control by 5 step electronic regulator copper winding complete as per IS:374-1979 or latest IE rule & site requirement, colour white, complete including taking down old unserviceable fan of any type & size from existing location and deposited in MES store yard complete all as specified and directed. Make:Havells/CG/Bajaj.
GEYSERS Comprehensive repair/maintenance of storage type electric water heater (Geyser ) vertical or horizontal type of capacity 50 Ltrs comprising of the followings : (a) Inspection, taking down, opening or dismantling, de-scaling,brushing and thoroughly cleaning the storage tank up to the satisfaction of the Eng-in-charge. (b) Checking of all stop cock, pressure release valves, fusible plugs for its serviceability etc in situ to ensure free movement of the parts including supply and replacing the washers/ gasket nut etc. (c) Checking and rectify earth continuity of the Electrical circuits of the Geysers and power point. (d) Checking, re-fixing thermostat and re-adjust. (e) De-scaling the immersion type heating element and siphon assembly with diluted Hydro chloric acid or clear pedette solution. (f) Checking of indicator lamp for it serviceability. (g) Re-assembling the Geyser, re-installation and testing complete.
(h) The rate for above ietm are deemed to include for transportation to fro of geyser to the work shop as approved by Engr-in-Charge/GE for necessary repairs and testing of Geyser at workshop. (j) Minimum two technicians (one Electrician and one plumber ) and two helper with all types of tools and plants/vehicle etc should report to E/M yard at 9am hrs in all working days and sundays / holidays for repair of geyser including taking down / fixing of same. (k) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (l) Repair works of geysers should completed and refixed the same within 12 hours after receipt of complaint slip.If the complaint not attended /not completed on same day recovery will be done from RAR bill as follows: a) For first day Rs 200. b) For second day Rs 300. c) For next every day Rs 500. Note : Parts / components of geysers found unserviceable shall be replaced by the contractor. New parts/components required shall be measured and paid separately under item here-in-after as supply only and labour charges required for replacement are deemed to be included in the quoted rate of item no. 19.
All as per Serial Item No. 19 here-in-before but 25 ltrs capacity.
Supply only thermostat (Adjustable type) of Rod/stem Type EST-11EM, 20A resistive, 250 Volt, opening on temperature rise of approved make and having ISI mark all as specified.
Supply only steel inner tank suitable for storage type water heater (geyser) 25 litre capacity.
Supply only steel inner tank suitable for storage type water heater (geyser) 50 litre capacity.
Supply only steel siphon geyser assembly 6/9 hole suitable for 50 ltrs capacity geyser of any make as required at site of approved make complete with inlet and outlet, provision for thermostat pipe with drain pipes & drain plug, screws, studs, clamps for fixing heating elements, gasket etc., complete all as specified & directed
All as per item No. 24 Here-in-above but siphon assembly suitable for 25 ltrs capacity Geysers.
Supply only heating elements of capcity 1.5 KW AC - 240 Volts suitable for storage type electric water heater as per site requirement (press type / screw type / triangular / circular base or ceramic cartige type), ISI marked all as specified and as directed.
All as per item No. 26 Here-in-before but of capacity 2 KW AC 240 Volts.
Supply only glass wool for geyser 25/50litres capacity all as directed.
Supply only gasket of thickness 5mm for geyser assembly of 09 holes/09 holes complete all as specified and as directed.
Supply only geyser indicator pilot lamps (red and green lamps) with wiring, round/ square/ rectangle type suitable for geysers of any type/capacity, complete all as specified & directed.
Supply only PVC connection pipe 15 mm dia, 450mm long with end nuts and washer, suitable for hot water outlet of geyser complete all as specified and directed.
Supply only PVC connection pipe 15 mm dia, 600mm long with end nuts and washer, suitable for hot water outlet of geyser complete all as specified and directed.
Supply only PVC connection pipe 15 mm dia, 450mm long with end nuts and washer suitable for cold water inlet of geyser complete all as specified and directed.
Supply only PVC connection pipe 15 mm dia, 600mm long with end nuts and washer suitable for cold water inlet of geyser complete all as specified and directed.
Supply only safety valve suitable for 25 Ltr/50 Ltr geyser all as specified and as directed.
Supply only non return valve 15mm bore as in replacement of old one and connection and testing complete all as specified and as directed.
Supply only plug top 3 pin 16 Amps, 240 volts. Make : Anchor/Philips.
Supply only flexible multi stranded copper wire three core of size 2.5 sqmm all as specified and as directed. (Make : Havells/Plaza/Polycab).
Supply only fastner mild steel 100/150/200mm long complete all as directed.
Supply and fix in repair Single pole and neutral enclosure(1P+N+E ) with a two pin and earth plug and socket complete with one double pole 20A MCB all as directed.Make Schneider cat No A9HMS220.
Supply and fix in repairs Switch socket combination universal type, 3 pin 16 Amp, flush type, 240 volts, ISI marked complete all as specified and as directed at site by the Engrs-in-Charge.
Supply, install and testing water heater storage type (Geyser) single phase 230V, 50Hz, 5 star energy saving high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type, 25 Litre capacity, 2000Watt rated power, incoloy 800 glass coated heating element, tank coating of feroglas powder, tank made of ultra thick super cold rolled steel plates, rated pressure 0.8MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting upand fixing arrangement on wall including providing hole fastners-04 Nos, hot & cold water PVC pipes 15 mm bore of adequate length as required at site-2Nos, chromium plated brass stop cock 15 mm bore -01 No and including necessary plumbing work, tesing including taking down existing old unserviceable geyser and depositing in MES Store yard all as spcified and directed. Make :- Havells Monza DX (Model No.GHWAMGTWH025 / Bajaj new shakti 25 litre vertical /Crompton greaves Solarium DLX SWH825 25Ltrs as approved by GE.
Supply, install and testing water heater storage type (Geyser) single phase 230V, 50Hz, 5 star energy saving high density PUF insulation tank made of heavy duty magnesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type, 50 Litre capacity, 2000Watt rated power, incoloy 800 glass coated heating element, tank coating of feroglas powder,tank made of ultra thick super cold rolled steel plates, rated pressure 0.8MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting upand fixing arrangement on wall including providing hole fastners-04 Nos, hot & cold water PVC pipes 15 mm bore of adequate length as required at site-2Nos, chromium plated brass stop cock 15 mm bore -01 No and including necessary plumbing work, tesing including taking down existing old unserviceable geyser and depositing in MES Store yard all as spcified and directed. Make :- Havells Monza DX (Model No.GHWAMGTWH025 / Bajaj new shakti 25 litre vertical /Crompton greaves Solarium DLX SWH825 25Ltrs as approved by GE.
WATER COOLER Disconnecting, dismantling and taking out the non-functional Water coolers of any description, any make and in any position, capacity 40 ltr to 150 ltr, including water connections, single phase, 50 Hz, strip opening, cleaning and servicing of the water cooler with using MAIC-DS solution, taking out and removing unserviceable/defective wiring & damaged/un-serviceable parts, replacement of the unserviceable and defective parts, necessary brazing, reassembling water cooler, restoring water supply connections and testing of the water coolers complete as all specified and directed by Engineer–in–charge. Note: (i) The replacement of defective / nonfunctional parts shall be measured & paid separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item. (ii) Replacement of unserviceable / damaged body portions of the water coolers shall also be measured and paid for separately under appropriate item of Schedule `A' as supply only but fixing/assembling element of new / repaired body parts with existing parts is deemed to be included under this item.
(iii) Burnt out windings and internal wiring, if any, replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding & supply only of internal wiring kit. (iv) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (v) Charging of gas to make up required pressure, if any, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. (vi) Rates quoted by the contractor for this item are also deemed to be included for de-scaling of chilled water pipe line including brazing of damaged portion of pipe line. (vii) The contractor should detail minimum one Refrigerator/AC Technician and one helper to attend complaints at different location under GE Kaluchak. (viii) The Complaint should be attended on same day. If the complaint not attended /not completed on same day recovery will be done from RAR bills as follows: a) For first day Rs 200 b) For second day Rs 300 c) For next every day Rs 500.
Material & Labour for cleaning / Flushing out the gas system with anti corrosive solution (CO2) with anti moisture substance condenser tubing by vacuumisation, pressure testing of the system, demoisturing the system, supply and charging of refrigerant gas and compressor oil in the water cooler of 40/80 litres or 60/120 litres capacity to its rated capacity including brazing, checking of leakage rectification of leakage in the entire system if any and testing on full load complete all as specified and as directed by Engineer in Charge. Note: The type of refrigerant gas (i.e R-12/R-22/R-134A ) shall be charged as per compressor compatbility or compressor manufacturer recommendation.
Material & Labour for cleaning / Flushing out the gas system with anti corrosive solution (CO2) with anti moisture substance condenser tubing by vacuumisation, pressure testing of the system, demoisturing the system, supply and charging of refrigerant gas and compressor oil in the water cooler of 150/150 litres capacity to its rated capacity including brazing, checking of leakage rectification of leakage in the entire system if any and testing on full load complete all as specified and as directed by Engineer in Charge. Note: The type of refrigerant gas (i.e R-12/R-22/R-134A ) shall be charged as per compressor compatbility or compressor manufacturer recommendation.
Supply only PVC Gasket non- magnet for chiller top any make of water cooler including fixing arrangement complete all as specified and directed.
Supply only starting relay unit suitable for any type and make water cooler all as directed.
Supply only starting capacitor 40/60 MFD Make : EPCOS/Sycaparisto/ASIAN.
Supply only starting capacitor 60/80 MFD (Make : EPCOS/Sycaparisto/ASIAN.
Supply only starting capacitor 80/100 MFD Make : EPCOS/Sycaparisto/ASIAN.
supply only Running capacitor 10 to 15 MFD : EPCOS/Sycaparisto/ASIAN.
Supply only Running capacitor 20 to 36 MFD : : EPCOS/Sycaparisto/ASIAN.
Supply only Thermostat , 220 volts suitable for water coolers upto 150 ltr cap complete all as specified and directed. Make : Indfoss / Renutrol/ Rockwell.
Supply only over load protector relay (Suitable for any make / model of compressor all as approved by Engineer-in-Charge. Make : Kilxen /KCL/ Electrica.
Supply only AC electric condensor motor of 1/35 HP , SP 230 Volts, complete with blade all as specified and directed. Make : KSB/Beacon/ Kirlosker.
Supply only AC electric condensor motor of 1/7 HP , SP 230 Volts, complete with blade all as specified and directed. Make : KSB/Beacon/ Kirlosker.
Supply only brass Nipple 15 mm dia for inlet and out let connection of water cooler any type / size including one PVC connection 15 mm dia with brass coupling on both ends.
Supply only Drain Pipe PVC flexible 25mm dia with one end circle clip complete all as specified and directed.
Supply only CP brass Push cock, 15 mm. Dia (ISI marked) inner/outer threaded complete all as specified and directed.
Supply only capillary tube suitable for any type and size of water cooler.
Supply and fix new sealed unit compressor for water coolers of any make and model, as approved by GE including vacuum testing and filling of Refrigerant Gas to required pressure complete all as specified and directed for the following capacity :-
(a) Refrigeration compressor suitable for 40/80 ltr capacity. Make :Voltas/Blue Star/Godrej.
(b) Refrigeration compressor suitable for 60/120 ltr capacity. Make :Voltas/Blue Star/Godrej.
c) Refrigeration compressor suitable for 120/150 ltr capacity. Make :Voltas/Blue Star/Godrej. Note for Srl item No 62(a), 62(b), 62(c) :-- (i) The cost of fixing, brazing to suction and discharge line and testing of compressor at site is deemed to be included under Schedule `A' item No.1. (ii) Refrigerant gas for charging of compressors shall be measured and paid for separately under respective item of this Schedule.
Supply only stop valve/ globe valve with iron wheel head screwed both ends for iron pipe and fixed complete of size 15mm.
Supply and Fixing only ball valves high pressure with polythene float and fly nut(PTMT) complete screwed for iron pipe or brass ferrule suitable for 15mm bore pipe complete all as specified and as directed. Make: Prayag/Polytuf.
DESERT COOLER Disconnecting and taking out the defective / non-functional desert cooler of any description and in any position, strip opening of desert cooler, cleaning, servicing, oiling & greasing etc of desert cooler, taking out and removing unserviceable / defective parts and internal wiring, replacement of unserviceable & damaged parts and internal wiring, re-assembling & testing of the desert cooler all as specified and directed by Engineer-in-Charge. Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item .and replacement of unserviceable / damaged body portions i.e. panels / switch board / bottom / top / grills / frame etc. of the desert cooler shall also be measured and paid for separately under appropriate item of Schedule `A'.
(ii) Burnt out fan windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (iv) The contractor should detail minimum one Refrigerator/AC Technician and one helper to attend complaints at different location under GE Kaluchak. (v) The Complaint should be attended on same day. If the complaint not attended /not completed on same day recovery will be done from RAR bills as follows: a) For first day Rs 200 b) For second day Rs 300 c) For next every day Rs 500.
Supply only PVC flexible water Pipe 15 mm dia including fittings suitable for desert cooler complete all as specified and directed by Engineer-in-Charge.
Supply only PVC distributor 3 way, 15mm dia for water distribution inside desert water cooler including clamping by screw/strip all as specified and directed by Engineer-in-Charge.
Supply only new 3 core PVC insulated copper cable size 2.5 Sq mm round 1100 volt grade as in connection to desert coolers all as specified and directed by Engineer-in-Charge.
Supply only gun metal bushes for fan motor of desert cooler all as specified and directed by Engineer-in-Charge.
Supply only Ball bearing suitable for Desert cooler all as directed. Make - TATA/SKF /NBC/NRB.
Supply only water lifting submersible pump 230Volts AC 50Hz for desert cooler 1.5 mtr head.(Make : Crompton / AUE / Khaitan/ Bajaj /Usha.
Supply only blower fan motor 230V AC 50Hz, 150w to 180w for desert cooler complete with blade, locknut, and standard accessories as per OEM complete all as directed. (Make : Crompton / AUE / Khaitan/ Bajaj.
Supply only PVC fan blade ( set of three blades) for cooler motor of any description to suit existing motor all as specified and directed by Engineer-in-Charge.
Supply only new wood pads of required size as approved (three in each on desert cooler) complete material and labour all as specified and directed by Engineer-in-Charge.
Supply only plug top 3 pin 5 Amps,240 volts.Make: Anchor/Philips.
REFRIGERATOR Disconnecting, dismantling and taking out the non-functional Refrigerators of any description, any make and in any position, capacity 165 ltr to 310 ltr, single phase, 50 Hz, opening, cleaning and servicing of the refrigerator with using MAIC-DS solution, taking out and removing unserviceable/defective wiring & damaged/un-serviceable parts, replacement of the unserviceable and defective parts, necessary brazing, reassembling refrigerator and testing complete as all specified and directed by Engineer–in–charge. NOTE (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item. (ii)The contractor should detail minimum one Refrigerator/AC Technician and one helper to attend complaints at different location under GE Kaluchak. (iii) The Complaint should be attended on same day. If the complaint not attended /not completed on same day recovery will be done from RAR bills as follows: a) For first day Rs 200 b) For second day Rs 300 c) For next every day Rs 500.
(iv) Replacement of unserviceable / damaged body portions of the Refrigerator shall also be measured and paid for separately under appropriate item of Schedule `A' as supply only but fixing/assembling element of new / repaired body parts with existing parts is deemed to be included under this item. (v) Burnt out windings and internal wiring, if any, replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding & supply only of internal wiring kit. (vi) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (vii) Charging of gas to make up required pressure, if any, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item.
Supply only new compressor unit for 195 Ltr capacity Refrigerator Make: Whirlpool/VOLTAS/LG/GODREJ.
Supply only new compressor unit for 310 Ltr capacity refrigerator Make: Whirlpool/VOLTAS/LG/GODREJ
Supply only new compressor unit for 280 Ltr capacity refrigerator Make: Whirlpool/VOLTAS/LG/GODREJ
Supply only blower fan motor suitable for refrigerator of cap 165 to 310 Ltr cap.
Supply only thermostat switch with defrosting arrangement suitable for Refrigerator of capacity 165 to 310 Ltrs
Supply only starting relay suitable for refrigerator of cap 165 to 310 Ltr cap.
Supply only magnetised door lock rubber strip gasket set complete for refrigerator of cap 165-310 Ltrs
Supply only freezer for Refrigerator 195 Lt capacity
Supply only freezer for refrigerator for 280/310 Ltrs capacity
Material & Labour for cleaning/ flushing out the gas system with anti corrosive solution with anti moisture substance ,condensor tubing by vacuumisation,pressure testing of the system ,demoisturing the system, Supply and charging of refrigerant gas and compressor oil in the Refrigerator of any capacity ranging from 165 litres to 195 litres ,to its rated capacity including brazing,checking of leakage , rectification of leakage in the entire system if any and testing on full load complete all as specified and as directed by Engineer in Charge.The type of Refrigerant gas (i.e R-12R/R-134A) shall be charged as per compressor compatibility or compressor manufacturer recommendation.
M & L for cleaning/ flushing out the gas system with anti corrosive solution with anti moisture substance ,condensor tubing by vacuumisation,pressure testing of the system ,demoisturing the system, Supply and charging of refrigerant gas and compressor oil in the Refrigerator of any capacity ranging from 210 litres to 310 litres ,to its rated capacity including brazing,checking of leakage , rectification of leakage in the entire system if any and testing on full load complete all as specified and as directed by Engineer in Charge.The type of Refrigerant gas (i.e R-12R/R-134A) shall be charged as per compressor compatibility or compressor manufacturer recommendation.
Supply only electric bulb SP 230 volts screw/Pin type with base all as directed
Supply only top plug three pins 15 Amps,240 volts, ISI marked all as directed.
Supply only over load protection for refrigerator of capacity 165 Ltr-310 ltr.
Supply only Freezer door with hinges for refrigerator of cap 280 ltr/310 Ltrs (As per sample )
Supply only Freezer door with hinges 165-210 Ltrs capacity (As per sample )
DEEP FREEZER Disconnecting, dismantling and taking out the non-functional Deep Freezers of any description, any make and in any position, capacity upto 400 Lts, including water connections, single phase, 50 Hz, strip opening, cleaning and servicing of the Deep Freezer with using MAIC-DS solution, taking out and removing unserviceable/defective wiring & damaged/un-serviceable parts, replacement of the unserviceable and defective parts, necessary brazing, reassembling Deep Freezer and testing of the Deep Freezer complete as all specified and directed by Engineer–in–charge. NOTE (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item.
(ii) Charging of gas to make up required pressure, if any, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. (iii) Rates quoted by the contractor for this item are also deemed to be included for de-scaling of chilled water pipe line including brazing of damaged portion of pipe line. (iv) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (v) The contractor should detail minimum one Refrigerator/AC Technician and one helper to attend complaints at different location under GE Kaluchak. (vi) The Complaint should be attended on same day. If the complaint not attended /not completed on same day recovery will be done from RAR bills as follows: a) For first day Rs 200 b) For second day Rs 300 c) For next every day Rs 500.
Supply and fix new compressor sealed unit for deep freezer 300/320 Ltrs obtained from the factory outlet /authorised dealer alongwith test certificate and with one year guarantee card and testing on full load complete all as specified and directed by Engineer in charge. Make: Blue star / Emerson /Tecumesh /LG /Kirloskar / Whirlpool. Note : Gas charging and gas shall be paid and measured separately under appropriate item of this schedule.
Supply and fix blower motor 1/9 HP 230 volt single phase Make: Unitech/Universal.
Supply and fix Thermostat for Deep Freezer upto 320 Ltrs capacity.
suopply only starting relay suitable for deep freezer upto capacity 500Litres.
Supply only overload protector device for deep freezer upto 500 litres capacity.
Supply only Running capacitor for deep freezer upto 400 Litres capacity.
Supply only Starting capacitor for deep freezer upto 400 Litres capacity.
Supply & charging gas refrigerant( R-134A or OEM recommendatation) to deep freezer upto 400 Ltr capacity in required qty complete all as directed by the Engineer in charge.
WINDOW / SPLIT AC Disconnecting, dismantling and taking out the non-functional Air conditioner window/Split type of any description, any make and in any position, 1.5/2 TR capacity, single phase, 50 Hz, strip opening, cleaning and on site comprehensive servicing/maintenance of the AC with electric blower,water under pressure, descaling,brushing and cleaning using caustic soda/detergent powder solution,filter cleaning and replacing ,cleaning of condensor tubes,cleaning of cooling coil of evaporator,lubrication of fan motor ,checking and tightning all nuts and bolts etc,checking of electric circuit for smooth functioning of Air conditioner etc checking,taking out and removing unserviceable/defective wiring & parts, painting the bottom with one coat of black synthetic enameled paint, replacement of the unserviceable and defective parts, brazing, reassembling(indoor/outdoor unit) and testing of the AC to make functional complete all as specified and directed by Engineer–in–charge. Note : (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item.
(ii) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (iii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item. (iv) The contractor should detail minimum one Refrigerator/AC Technician and one helper to attend complaints at different location under GE Kaluchak. (v) The Complaint should be attended on same day. If the complaint not attended /not completed on same day recovery will be done from RAR bill as follows: a) For first day Rs 200 b) For second day Rs 300 c) For next every day Rs 500. (vi) Equipment shall be serviced once in six month and no repeat maintenance shall be measured.
Supply only over load protector relay suitable for window/ Split type AC 1.5/2 TR capacity complete all as directed. (Make :Kirloskar / KCL/ Pecific/ Renutrol/ Hitech)
Supply only relay assembly 1.5 / 2TR Window AC including making necessary connections and testing complete all as directed by Engineer in Charge. Make : Ranutrol/Anupurna/Kirloskar /Danfoss /Indfos/Classic.
Supply only running capacitor 36-60 Mfd, 230 Volts, suitable for window/Split type AC 1.5/2 TR complete all as specified and directed by Engineer-in-Charge. Make : EPCOS/Sycaparisto/ASIAN /Usha /Havells /Tesla.
Supply only starting capacitor 80-120 Mfd, 230 Volts, suitable for window/Split type AC 1.5/2 TR complete all as specified and directed by Engineer-in-Charge. Make: EPCOS/Sycaparisto/ASIAN/Usha /Havells/Tesla.
Supply only capacitor 4/6 Mfd, 230 Volts for blower motor complete all as specified and directed by Engineer-in-Charge. Make : EPCOS/Sycaparisto/ASIAN /Usha / Havells/Tesla.
Supply only Thermostat Switch suitable for window/Split AC 1.5/2 TR including making necessary connections and testing complete all as directed by Engineer in Charge all as directed by Engineer-in-Charge. Make : Indfos/AnnaPurna/Ranutrol /Indfoss /Pecific.
Supply and fix AC Electric Blower motor of 1/3 HP to 1/8 HP 230 volts 930 RPM,copper wound, 3 speed,single/double shaftas per existing model suitable for window type/Split type AC and capacity upto 2TR complete all as directed. Make : KSB/Beacon/ Kirlosker/Usha/Carrier /Fedders Llyoid/Voltas/Hitachi.
Supply and fix electrical wiring kit (PCB) of window/Split AC all as specified and as directed.
Disconnecting and taking out existing defective compressor of any description & in any Position and supplying and fixing new Refrigeration Compressor obtained from factory outlet/authorised dealer alongwith test certificates and with one year guarantee card for any type of widow AC 1.5/2TR Capacity, single phase, 230volt including brazing to suction & discharge line, replacement of capillary tube and dryer filter,replacement of foundation rubber pads,nuts and bolts ,vacuum testing, with and including providing and filling/charging of refrigerant gas(R 134) & testing on full load complete all as directed by Engineer-in-Charge. (Make Godrej/Blue Star/Voltas/Kirloskar/Copeland/Tecumseh/Carrier ).Note:Refrigerant Gas will be provided by Contractor.
All as per item No 111 here-in-before but for Split AC 1.5/2 TR.
Supply only new 3 core PVC insulated copper cable size 2.5 Sq mm round 1100 volt grade as in connection to desert coolers all as specified and directed by Engineer-in-Charge.
Supply and charging(Top up) of refrigerant gas R-134 or OEM recommended refrigerant to Window/Split AC upto 2TR to make up required pressure complete cleaning/ flushing out the gas system with anti corrosive solution with anti moisture substance ,condensor tubing by vacuumisation,pressure testing of the system ,demoisturing the system complete all as specified and as directed by the Engineer in Charge.
Supply and fix synthetic rubber tube insulation of thickness 9mm and internal diameter 6mm / 13mm for refrigerant copper piping of split AC's all as directed.
Material & Labour for shifting of split type AC 1.5/2 TR capacity including dismantling all accessories indoor/outdoor unit,copper insulation,voltage stabilizer from position transportation to new location and reinstalling the all accessories as directed,grouting /fixing with nuts/bolts complete all as specified and directed by Engineer in charge.
Material & Labour for shifting of Window type AC 1.5/2 TR capacity including dismantling from position transportation to new location and grouting /fixing with nuts/bolts complete all as specified and directed by Engineer in charge.
Supply and fix in repair Single pole and neutral enclosure(1P+N+E ) with a two pin and earth plug and socket complete with one double pole 20A MCB all as directed.Make Schneider cat No A9HMS220.
Supply and fix in repair metallic plugs top of AC box 20A specified make,2P+E and connecting all as specified and directed. Make:C&S cat No CSDBPSPN020 or equivalent in schneider/Legrand/ABB.
Material & Labour for converting the existing AC (Window/Split) type from cooling system to heating system of the existing AC by using reverse cycle valve ,toggle switch,new heating element 2.5KW, etc and necessary extension to suction / discharge copper tubing from window / split type of any capacity complete all as specified and directed.
Supply and fix in repairs MCB SP-06 to 32 Amp, C curve, 240 volts complete all as specified.
Supply and fix in repairs MCB DP-6 to 32 Amp, C curve,240 volts 50Hz AC supply, complete all specified.
VOLTAGE STABILIZER Disconnecting & taking out the non-functional voltage stabilizer of any description and in any position & strip opening of Voltage Stabilizer of 4/5 KVA single phase, air cooled, taking out unserviceable/defective wiring & parts, cleaning and servicing complete including replacement of unserviceable parts with new one and unserviceable wiring with new PVC insulated and unseathed stranded copper conductor cable of existing size, reassembling ,connecting and testing including cleaning the exposed surfaces of stabilizers& applying a coat of synthetic enamel paint after preparation of old painted steel surfaces and writing MES No/SM No in different tint in the pattern & style all as directed by Engineer-in-Charge complete all as specified and directed. Notes (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item.
(ii) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (iii) The Complaint should be attended on same day.If the complaint not attended /not completed on same day recovery will be done from RAR bill as follows: a) For first day Rs 200 b) For second day Rs 300 c) For next every day Rs 500.
All as per Item No. 123 above but stabilizer of capacity 2/3 KVA.
All as per Item No- 123 above but stabilizer of capacity 0.5/1 KVA.
Supply only the following new parts commonly used in the voltage stabilizer of any capacity (0.5 KVA to 5 KVA) & any type as approved by GE. (Make : Blue Line/Blue Bird/Citizen/volina/Luminous/v-guard) : -
(a) Power transformer Input 140 – 280 volts & output 220 volts + 9% for 4/5 KVA Stabilizer
(b) Power transformer Input 140 – 280 volts & output 220 volts + 9% for 2/3 KVA stabilizer
(c) Power transformer Input 140 – 280 volts & output 220 volts + 9% for 0.5/1 KVA stabilizer
(d) Relay 24 volts, single change over, 30 Amps. (MAKE : OEN/ Dunmag / Eagle man)
(e) Relay 18 volts, single change over, 10 Amps.
Pyramid constructions
Bidder Name
M/S PRAJAPATI ENGINEERS
Pyramid constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .