| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.1 LAccepted-Finance PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L1 | Accepted-Finance Being lowest | |
| 2 | L2₹71.8 L+₹1.7 L (2.49%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹72.5 L+₹2.4 L (3.42%)Rejected-Finance COLABA MUMBAI | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹72.9 L+₹2.8 L (4.00%)Rejected-Finance COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹75.8 L+₹5.7 L (8.13%)Rejected-Finance COLABA MUMBAI | L5 | Rejected-Finance Being other than lowest |
Tender Value
₹63 L
EMD Value
₹1.2 L
Closing Date
29 Aug 2020, 6:00 pmClosed
CWE NW Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIRS REPLACEMENT AND ROUTINE MAINTENANCE OF ELECT LIFTS AT CORE 1 2 4 6 8 OTIS MAKE AT INHS ASVINI AND REPAIRS AND ROUTINE MAINTENANCE INCLUDING MANUAL OPERATION AND RESCUE OPERATION OF LIFTS AT CORE 3 AND CORE 7 OF BLDG P 72 AND 40 S
2020_MES_363868_1
8071/CWE(NW)/MUMBAI
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
AGE (I) Asvini
Class C and above and category
c ii and d v
8 documents required · 8 mandatory
₹1,000
Yes
AGE (I) Asvini
₹1.2 L
Yes
1 Sept 2020
24 Jul 2020
31 Aug 2020
24 Jul 2020
29 Aug 2020
16 Aug 2020
24 Jul 2020 - 14 Aug 2020
Amount
Repair/Route maintenance of lifts including carrying out daily check and periodical services of fully automatic electrically operated passenger lift (OTIS) make, 10 Passengers, 680 Kg Capacity) having dual power operatede door, automatic leveling device and microporcessor based duplex collective control system with repair and replacement of unserviceable parts such as bearings, bushes, all type of guide shoes, hangers, door rope, door locks and its contacts control cards / logic boards, control connector/ links, lmit switches, hall push buttons and its spares, rewinding of motors, welding of cracked /broken MS parts if any, repair /replacement of door safety edge working at any principle and any type sensor or mechanical safety lock, magnetic lock or contact, LOP & COP buttons with bulbs, car position indicator floor calling / indication disply buttons , floor / door sill, necessary wiring and cable as per requirement for safe operation of lift, maintaining of cabin, cabin fan repair, cabin light, acrilic sheets of suitable size, maint of auto rescue devise (ARD), cleaning of SWR with cleaning oil etc to ensure safety and smooth functioning of complete all as specified and directed of Lift No 06 at Core 8 INHS Asvini (01 No Lift)
All as per item No 1 above but for Lift No 01 at CORE-1 (Simplex Control System) at INHS Asvini
All as per item No 1 above but for Lift No 03 at CORE-2 (Simplex Control System) at INHS Asvini
All as per item No 1 above but for Lift No 15 at CORE-6 (Simplex Control System) at INHS Asvini
All as per item No 1 above but for 16 Passengers lift 1088 Kg Capacity, Lift No 07 at CORE-8 (Duplex Control System) at INHS Asvini
All as per item No 1 above but for 20 Passengers lift 1360 Kg Capacity, Lift No 14 at CORE-4 (Simplex Control System) at INHS Asvini
All as per item No 1 above but for 26 Passengers lift 1768 Kg Capacity, Lift No 02 at CORE-2 (Simplex Control System) (Bed Lift) at INHS Asvini
All as per item No 1 above but for 26 Passengers lift 1768 Kg Capacity, Lift No 13 at CORE-4 (Simplex Control System) (Bed Lift) at INHS Asvini
Taking out old unserviceable cabin fan from car cabin, supply & fixing new cabin fan non-oscillating type axial flow, single speed 300mm sweep. 240 Volts ISI mark with powder coated grill complete all as specified & directed . Make: VBM/EMCO/CINI
Dismantling & taking out unserviceable sensor system complete, supply & fixing new sensor system assembly with new edge along with full beam infrared sensor upto full length of car doors complete all as specified and directed. Make: WECO/TL JONE/ OTIS.
Taking down existing unserviceable ARD from Machine room and supply and fixing New ARD (Automatic Rescue Device) comprising of PCBs, Transformers, invertors, relays, and all connnected electric & electronic components including replacing of existing unserviceable batteries 12V 17 AH - 04 Nos with maintenance free batteries of same / equivalent capacity complete all as specified and directed. Make: Exide / Amron
Manning and operation of electrically operated lifts of any make type and capacity to serve any floors 08 hrs daily i.e. (One shift of 08 hours per day) (0700 hrs to 1500 hrs) including taking care of lift from any pilferage, theft or damage etc, in INHS Asvini Lift No 15 (One lift) complete all as specified and directed
Manning and operation of electrically operated lifts of any make/type and capacity to serve any floors 16 hrs daily i.e. two shift per day from 0600 hrs to 1400 hrs, 1400 hrs to 2200 hrs including Sunday and holidays including taking care of all lifts from any pilferage, theft or damage etc in INHS Asvini. complete all as specified and directed for the following buildings :- (A) AT CORE-3 (i) Lift No - 04 (Bed lift 15 passenger 1020 Kg) (ii) Lift No - 05 ( Bed Lift 20 passengers 2040 Kgs) (B) AT CORE-7 (i) Lift No - 08 (16 Passenger 1088 Kg) (ii) Lift No - 09 (1000 kg freight elevataor) (iii) Lift No - 11 (Bed lift 15 passenger 1020 kg) (iv) Lift No -12 (16 Passenger 1088 Kg)
Repairs/routine maintenance of fully automatic electrically operated passenger lift (OTIS make) of capacity 16 Passengers or 1088 Kgs having power operated door, automatic levelling device and microprocessor based collective control system with repair and replacement of unserviceable parts such as bearings, bearing bushes, all type of guide shoes, hangers, door rope, door locks and its contacts control cards, control connector/ links, hall push buttons and its spares, rewinding of motors, welding of cracked /broken MS parts if any, repair /replacement of door safety edge working at any principle and any type sensor or mechanical safety lock, magnetic lock or contact, COP & LOP buttons with bulbs, car position indicator, door sill, necessary wiring and cable as per requirement for safe operation of lift, maintaining of cabin, cabin fan repair, cabin light, maint of auto rescue devise (ARD) cleaning of SWR with cleaning oil etc to ensure safety and smooth functioning etc to ensure safe and smooth functioning of Lift all as specified and as directed by Engineer-in-charge, for Lift No-08 (16 Passenger) and Lift No-12 (16 Passengers) at Core 7 INHS Asvini. (Total two Nos lifts) Note: Cost of spare parts / material required for above mentioned maintenance is deemed to be included in the quoted rate. No additional cost of spares is admissible for the above maintenance.
All as per item No 14 above but for Lift No-11 (Bed lift 15 Passengers) at CORE-7 and Lift No- 04 (Bed lift 15 Passengers) at CORE-3 of INHS Asvini (Total two Nos lifts).
All as per item No 14 above but for Lift No-05 (Bed lift 20 Passengers capacity) at CORE-3 of INHS Asvini.
All as per item No 14 above but for Lift No-09 (1000 Kgs Freight Elevator) at Core-7 of INHS Asvini.
All as per item No 14 above but for Lift No-10 (500 Kgs Freight Elevator) at CORE-7 of INHS Asvini.
Note for above items :- (a) There shall be two category of operators :- (i) One category is Rescue Operator who shall be invariably ITI qualified & trained for Rescue Operation for all the building - Each shift. (ii) The other category is for Lift mechanic (skilled) duly trained for all building (b) Rescue operator having ITI qualification with at least 02 (Two) years practical experience shall posses thorough knowledge to rescue user in case of emergency like anybody getting trapped in lifts (Rescue Operator) for all building - Each Shift (c) Passes will be processed alongwith (after verification on signed certificate, verified ITI certificate only. Pass shall not be granted without submission of ITI qualification proof & experience certificate. (d) Contractor shall submit ID proof, Residential proof, Bank A/C details to department and obtain approval of Engrr-in-Charge before employing a person as Lift mechanic and Rescue Operator. (e) Payment to Lift mechanic and Rescue Operators shall be done by crossed cheque only which shall not be less than minimum fare wages as per Act in vouge. The contractor shall submit proof to Engineer-in-Charge before claiming any payment. After entire satisfaction of Engineer-in-Charge the payment action shall be processed further. (f) Rescue Operators shall be trained for rescue passangers of lift by an enlisted OEM / Lift maintenance contractor / Lift maintenance having approval lift licence issued by lift inspector of PWD and certificate for the same be submitted with proposal for passes.
(g) Lift mechanic shall be available as per the shift timings specified in the tender and he will report to JE E/M in-Charge or Lift Cell in-Charge. In case of emergency he will function according to their direction. If he is found absent or move without intimating to in-Charge of Lift Cell or JE E/M he will be treated as absent for the said shift and recovery to this effect for Rs 1500/- per shift shall affected. (h) Payment as per quoted rate shall also be deducted in addn to the penalty as specified above. (j) In case of malfunctioning if any noticed, lift operator shall intimate to the lift cell. (k) In case of any necessity for rescue operation or accident, Rescue Operator shall be capable of rescue the passenger and reacting to the situation (accident etc) (l) Contractor shall submit the labour licenece and Copy of GST Regn registered number issued by concerned authority. (m) Insurance coverage, compensation if any applicable or necessitated due to mis operation of lift shall be the responsibility of contractor. The quantum of compensation shall be assessed based on the BOO composing of Lift Inspector of Maharashtra State, representatives of both agencies carrying out M&O works and routine maintenance work of lift and members from department.
Repair/Routine maintenance of fully automatic electrically operated passeanger lift two Nos of capacity 08 Passengers of 544 Kgs having power operated door, automatic levelling device and microprocessor based collective control system with repair and replacement of unserviceable parts such as bearing bushes, all type of guide shoes, hangers, door rope, door locks and its contacts controll cards, control connector/ links, limit switches, hall push buttons and its spares, rewinding of motors, welding of cracked / broken MS parts if any, repair /replacement of door safety edge working at any principle and any type sensor or mechanical safety lock, magnetic lock or contact, LOP & COP buttons with bulbs, car position indicator floor calling / indication disply buttons , floor/ door sill, necessary wiring and cable as per requirement for safe operation of lift, maintaining of cabin, cabin fan repair, cabin light, acrilic sheets of suitable size, maint of auto rescue devise (ARD), cleaning of SWR with cleaning oil etc to ensure safe and smooth functioning of Lift complete all as specified and directed for 40 single officers accn at INHS Asvini. (Total two Nos lifts)
Dismantling and taking out unserviceable VVVF of any specifications and Supply, fixing and testing in existing control panel new VVVF (Variable Volstage Variable Freequency) Drive control unit of capacity 11 kw Make: Yaskawa, Model L-1000 complete all as specified and directed
Shree Elevator Engineering Co.
Monarch Enterprises
Escon Elevators Pvt Ltd
Veer High Tech Solution
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .