Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹17.7 L+₹1.2 L (6.98%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹17.7 L+₹1.2 L (7.02%)Rejected-Finance FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹18.0 L+₹1.4 L (8.47%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹19.1 L+₹2.5 L (15.2%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L5 | Rejected-Finance Other than lowest |
Tender Value
₹26.3 L
EMD Value
₹52,500
Closing Date
20 Oct 2020, 6:00 pmClosed
CWE New Delhi
HQ CWE New Delhi, Rao Tula Ram Marg, Delhi Cantt-10
Special repair to Bldg No P-67 SDS Mall of 1 CBPO under GE (South), Delhi Cantt-10
2020_MES_344385_1
CWE-ND/04/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
Delhi Cantt
Please refer tender document
9 documents required · 9 mandatory
₹500
GE (South)
₹52,500
Yes
13 Nov 2020
23 Jul 2020
22 Oct 2020
23 Jul 2020
20 Oct 2020
6 Oct 2020
Amount
Dismantling of brick tiles (laid flat or on edge) on roof surface, laid bedded and pointed in any mortar complete all as specified and as directed.
Demolition of mud in roof, any thickness, including plastering and leeping up to two storey bldg. including necessary scaffolding arrangement and removing outside the MOD land complete all as specified and as directed.
M&L for brushing neat cement slurry with 3.00 Kg of cement per Sqm on existing surfaces all complete all as specified and as directed.
M&L for PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) finish surface even & smooth using extra cement as in roof padding to maintain the uniform slope complete all as specified & directed.
S&F APP polymeric water proofing membrane minimum 3 mm thick and weighing not less than 3.0 kg per Sqm of black finish reinforced with non woven polyester matt with a thermo fusible finish laid over a coat of bitumen primer @ 0.5kg/Sqm by torching application with a propane or a butane gas torch with an overlap of 100 mm at the sides and 150 mm at the ends and including applying a coat of cold emulsion bituminous primer all as per manufactures instructions including preparation of surface complete all as specified and directed. Note :- The water proofing treatment shall beexecuted by manufacture or their authorized applicators only.
M&L for cement concrete tiles 25cmx25cmx22mm thick, machine pressed, set jointed and pointed in neat cement slurry in floors, and cut and polished with grey cement and pigments over 20 mm thick screed bed in CM (1:6) complete all as specified and directed .
M & L for Providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered edges including necessary form work complete as specified and directed .
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete as specified and directed .
M&L for Vitrified Ceramic tiles light shade, 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including screed bed or bedding layer of mortar 15 mm thick in CM 1:6 complete all as specified and directed.
All as per item No 09 here-in-before but as in skirting laid over and including 10 mm thick backing coat of cement mortar (1:4), complete all as specified and directed.
Dismantling of stone slabs of any description or thickness in floors, aprons etc. laid and bedded in any mortar, complete all as specified and directed.
M&L for Machine cut Mirror polished kota stone slab flooring 18 to 20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
All as per item No 14 here in before but in vertical surface including 10 mm thick backing coat of cement mortar (1:4), complete all as specified and directed.
Taking down cement plaster including racking out joints hacking for key scrubbing down with water etc. on walls and ceiling, complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 on wall surfaces and finished surface even and smooth without using extra cement complete all as specified and as directed .
M&L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 on wall surfaces and finished even and smooth without using extra cement, complete all as specified and as directed.
M&L for 10 mm thick rendering in CM (1:3) on ceiling finished even & Fair without using extra cement, complete all as specified and as directed.
M&L for applying two coats of cement base paint, white or tinted on new plastered surface including preparation of surface, complete all as specified and as directed.
M & L for preparing new plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & including a coat of wall care putty, complete all as specified and as directed.
M&L for 3 coat of white wash on ceiling including preparation of surface over newly plastered surface, complete all as specified and as directed.
M&L for preparation of old decorated wall surfaces by complete removal of existing treatment and applying two coats of cement base paint, white or tinted (colour and shade as per new colour scheme approved by GE) over a coat of primer of same make complete all as specified and directed.
M&L for complete removal of existing treatment , washing down and stopping of distempered and painted surfaces and old plastered or unplastered surfaces of wall and applying two coats of distemper oil emulsion, white or tinted over & including a coat of wall care putty complete, all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness including frame work complete all as specified and directed.
M&L for 16 mm thick of size 600x 600 mm mineral fibre false ceiling system of bevelled tegular edge classic pattern including grid system using hot dipped galvanised steel section, exposed surface with pre-powder coated capping, main runner and cross runner and to comprise main tee/runner 15 mm x 38 mm size (load carrying capacity 14 kg/Sqm) spaced at 1200 mm centres securely fixed to the structural soffit and flush fitting 1200 mm long cross tee/runner to be interlocked between main runners at 600 mm centre to centre form 1200 x 600 mm module, cut sub cross tee/runner 600 mm require independent support. Wall angle of size 19 mm x 19 mm, secured to the periphery of the wall at 450 mm maximum centres. The above grid is suspended at every 1200 mm centre to centre in both direction and starting from wall at the distance 350 mm from wall by using 3.50 mm dia aquiline wire with suitable fasteners and hook clip complete all as specified and directed.
Taking down old unserviceable Aluminium/Copper point wiring (light, fan, socket or power) including steel terminal boxes, switches, ceiling roses, pendants, sockets, regulators, etc. and making good disturbed surfaces of walls to match with existing surface, complete all as specified and as directed.
M&L for point wiring complete with single core multi strand copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 Volts grade electrical cable in and including concealed PVC existing conduit medium grade and sunk in new pressed steel terminal boxes of required size factory made and factory painted with stove enamelled black paint with top cover 3 mm thick plastic/laminated sheet (ISI Marked) of required colour with screwed and cup washer with all accessories including 1.5 Sqmm single core with multi strand copper conductor PVC unsheathed cable earth and connected to earth dolly complete all as specified for following : Note : (1) The rate is inclusive cutting /chasing and making good the disturbed surface with CM 1:3 and same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash complete. (2) New conduit with connected accessories will be laid if there is damage/blockage in existing conduit and the rates are inclusive of quoted rate.
(a) One light/fan point controlled by one way switch
(b) One 3 pin socket outlet 5 amps independent board
(c ) One 3 pin socket outlet 5 amps point on same board
(d) One 3 pin socket outlet, 15 amps on independent board with cable 2.5 Sqmm for main current and 2.5 Sqmm as earth wire as power point.
( e) One 3 pin socket outlet, 15 amps on independent board with cable 4 Sqmm for main current and 4 Sqmm as earth wire as power point for AC.
S&F switch piano, flush type 5 Amps single pole one way, complete all as specified and directed.
S&F socket, flush type 5 Amps single pole one way, complete all as specified and directed.
S&F switch piano, flush type 15 Amps single pole one way, complete all as specified and directed.
S&F socket, flush type 15 Amps single pole one way, complete all as specified and directed.
S&F ceiling rose surface Bakelite 60x25 mm two to three terminals, complete all as specified and directed.
S&F fan regulator electronic, socket type complete all as specified and directed.
Taking down carefully old unserviceable aluminium sub main wiring any type including all accessories complete and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area i.e. with OBD/colour wash/white wash as the existing finish complete all as specified and directed.
M & L for power/sub main wiring with two runs of single core 6 Sqmm size and one run of single core 6 Sqmm (green colour as earth continuity conductor ) PVC insulated unsheathed multi stranded copper conductor cables drawn through PVC concealed conduit not less than 25 mm dia including all accessories all as per site requirement complete all as specified and directed . Note :Two runs of 6 Sqmm single core copper conductor and one run of 6 Sqmm copper conductor shall be measured as one unit length)
Supply & fix in replacement of sheet metal enclosure MCB DB double door bus bar neutral link, earth bar and din rail SPN 12 way complete all as specified and directed.
Supply & Fixing in replacement of MCB SPN 40 Amps 240 volts complete all as specified and directed.
Supply & Fixing in replacement of MCB SP 10 to 32 Amps 240 volts complete all as specified and directed.
S&F in replacement of distribution board triple pole and neutral (VTPN) 4 way for fixing MCCB up to 125/160 Amps as incomer and MCBs as out goings with metal door and IP 43 Protections and connecting complete all as specified
S&F MCCB in replacement MCCB 125 Amp 3 pole, 415 V, 36kA complete all as specified and directed.
S&F in replacement MCCB 160 Amp 3 pole, 415 V, 36kA complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25 mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing complete all as specified and as directed.
M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire
S & F LED in replacement of Integrated Batten T5 20 watt - 4 Ft White, indoor decorative PVC extruded T5 LED batten-integrated type complete with including flexible wire in replacement of old unsv existing 36 Watt tube light fitting complete all as specified and as directed.
S&F in replacement of ceiling surface mounting in round shape LED down lighter with durable housing with Al heat shrink with diffuser to give glare free light with removable driver 6 Watt LED 6000K lamp type in replacement of old unserviceable existing CFL fitting any type from ceiling of stairs/common areas, complete all as specified and directed.
S&F LED Building security light fitting 45 Watt on existing bracket with suitable size of nuts, bolts and washers including replacement of old unsv existing security light fitting any type complete all as specified and as directed.
S&F Recessed Mounting 36 Watt 2'x2' flat LED panel fitting with soft light and glare free symmetrical illumination suitable for POP/Gypsum/Arm Strong false ceiling supplied with wedge bracket to fix in existing POP ceiling including cutting/grouting of existing POP ceiling in replacement of existing old unserviceable CFL fitting any type from ceiling of stairs/common areas and making good a disturbed surface/POP ceiling to match with POP and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and directed.
S&F in replacement ceiling Fan 1200 mm sweep, 5 Star rating in pearl white complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Note : Old u/s ceiling fan will be deposited by the contractor in MES store.
Supply and fix in replacxement metal body exhaust fan 450 mm sweep copper wound of 230 volts with louver including necessary electric connection with appropriate size of PVC copper wire from ceiling rose / switch board to exhaust fan and suitable size of nuts, bolts and washers complete all as specified and directed . Note : Old u/s fan will be deposited by the contractor in MES store.
Taking down of Wall mounted fan and Air circulator of any size and dismantling of blades complete all as specified and directed at site.
M&L for painting of wall mounted & air circulator of 650 mm after repair with spray gun in off white colour with good quality of synthetic enamelled paint complete all as per specified and directed .
M&L for Rewinding of wall mounted air circulator of 650 mm by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enamelled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush, ball bearing, painting where ever required. Note:- Cost of replacement of gun metal bush and bearings shall be included in quoted rates.
M&L for Rewinding of wall mounted fan of 450 mm by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enamelled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush, ball bearing where ever required. Note:- Cost of replacement of gun metal bush and bearings shall be included in quoted rates.
S & F in replacement Metal clad plug and socket 20 Amps with MCB SP and steel enclosure.
M&L for GI tubing medium grade 15 mm dia including cutting, screwing and necessary welding with painting the rod in good quality of synthetic enamelled white paint and making a hole at specific point of rod using as down rod suitable for ceiling fan up to 4 feet and to be fixed with ceiling fan bearing assembly including nut, bolts and washers as required complete all as directed at site.
P R Constructions
The new hut furnitures
aggarwal engineers contractors
verma enterprises
ramveer Singh
M/S.M.S.Devi.Const.Co
m/s VK construction company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .