Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7.5 LQualified Make: MAHINDRA - GSP
Model: GSP/82.5/TP/C2-F3 B 2 16 MOHAN COOPERATIVE INDUSTRIAL ESTATE BADARPUR BORDER NEW DELHI SOUTH DELHI DELHI 110044 | SOUTH EAST DELHI | DELHI | 110044 | Make: MAHINDRA - GSP
Model: GSP/82.5/TP/C2-F3 | L1 | Qualified | |
| 2 | L2₹7.5 L+₹1,499 (0.20%)Qualified Make: Swadeshi WhisPower
Model: Skyline Power Solutions, Model WDL82.5KT-3A-2Y-INST-NEW 13 14 RAJA GARDEN NEAR RAJOURI GARDEN METRO STATION NEW DELHI WEST DELHI DELHI 110015 UDYAM DL 11 0014726 07AAAPA2227M1Z3 B 18AAAPA2227M1Z0 G 02AAAPA2227M1ZD M 07AAAPA2227M1Z3 R MII STATUS AS VERIFIED | WEST DELHI | DELHI | 110015 | Make: Swadeshi WhisPower
Model: Skyline Power Solutions, Model WDL82.5KT-3A-2Y-INST-NEW | L2 | Qualified | |
| 3 | L3₹7.5 L+₹4,576 (0.61%)Qualified Make: Mahindra
Model: MAHINDRA-82.5KVA MECH CPCB2 22 IIIRD FLOOR MAIN MARKET MOTI NAGAR DELHI DELHI 110015 | WEST DELHI | DELHI | 110015 | Make: Mahindra
Model: MAHINDRA-82.5KVA MECH CPCB2 | L3 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
24 Jul 2018, 11:00 amClosed
diesel generators- DG Sets Experience with Gov. Required 5 Year (s) Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 82.5 82.5 No of Phase - Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine false - BIS license No
if applicable - - Type of Engine cooling Liquid Cooled Liquid Cooled Type of governer Mechanical Mechanical Class of governer A1 A1 Number of cylinders (nos) 4 - No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500 1/4 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 - Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 82.5 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 91.1 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 2 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel AMF AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6 Thickness of Foam 40 - Density of Foam for sound insulation 32 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - Test Report number - - 2/4 and date(Engine) Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986
in respect of noise and emission norms
as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 2.0 Installation & Commissioning With Installation With Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Varinder Kumar 181124
Frontier Hqrs
Border Security Force
Paloura Camp
Jammu 1 15
338426
GEM/2018/B/47966
diesel generators- DG Sets
15 days
Jammu And Kashmir; Jammu
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| diesel generators- DG Sets Experience with Gov. Required 5 Year (s) Diesel Generators- DG Sets ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 82.5 82.5 No of Phase - Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine false - BIS license No | - | - | - |
| if applicable - - Type of Engine cooling Liquid Cooled Liquid Cooled Type of governer Mechanical Mechanical Class of governer A1 A1 Number of cylinders (nos) 4 - No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500 1/4 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 - Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 82.5 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 91.1 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 2 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel AMF AMF IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6 Thickness of Foam 40 - Density of Foam for sound insulation 32 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - Test Report number - - 2/4 and date(Engine) Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 2 2.0 Installation & Commissioning With Installation With Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Varinder Kumar 181124 | - | - | - |
| Frontier Hqrs | - | - | - |
| Border Security Force | - | - | - |
| Paloura Camp | - | - | - |
| Jammu 1 15 | - | - | - |
Exempted
24 Jul 2018
16 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_338426.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .