| 1 | L1₹47.4 LAccepted-AOC NO 9A VINAYAKANILAYA KANAKA GANAPATHI STREET OM SHAKTHI LAYOUT KANAKAGIRI HORAMAVU POST BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹48.9 L+₹1.2 L (2.54%)Rejected-Finance | L2 | Rejected-Finance No lowest | |
| 3 | L3₹48.9 L+₹1.2 L (2.59%)Rejected-Finance | L3 | Rejected-Finance No lowest | |
| 4 | L4₹48.9 L+₹1.3 L (2.67%)Rejected-Finance | L4 | Rejected-Finance No lowest | |
| 5 | L5₹49.4 L+₹1.8 L (3.72%)Rejected-Finance NO 8 1 KHB MAIN ROAD OPP NATURE VIEW APARTMENT MANORAYAN PALYA RT NAGAR BANGALORE 560 032 | BENGALURU URBAN | KARNATAKA | 560032 | L5 | Rejected-Finance No lowest |
Tender Value
Refer Docs
EMD Value
₹92,000
Closing Date
27 Jun 2022, 6:00 pmClosed
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
PROVISION OF STORAGE ACCN SPECIAL REPAIRS ROOF INCLUDING SHIFTING OF SOLAR PANEL JOINERY AND OTHER MISC B R SANCTION WORKS AT MDC UNDER GE N BLORE
2022_MES_528904_1
8285
Open Tender
Civil Works
Item Rate
150 days
BLORE
Class D Category a(i) b(i)
7 documents required · 7 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹92,000
Yes
8 Aug 2022
6 Jun 2022
29 Jun 2022
6 Jun 2022
27 Jun 2022
21 Jun 2022
6 Jun 2022 - 20 Jun 2022
Amount
(B/R PORTION)
Demolition of cement concrete and paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed.
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Dismantling of Stone sett paving of any description or thicknessor thickness in floors, aprons etc (Laid bedded and pointed in any cement mortar) incl removing off the premises etc complete all as specified and as directed
Dismantling of single layer Mangalore pattern roofing including ridges bedded in cement mortar etc complete all as specified and as directed
Demolition of brick work /stone masonry/PCC block masonry built in cement mortar of any description all as specified and directed.
Taking down cement plaster of any description hacking for key or raking out joint on old brick work/stone/concrete surface etc complete all as specified and as directed
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition), as in Roofs, floors, beams, staircases, landing,chajjas, walls and similar suspended work etc complete all as specified and as directed
Taking down chowkats or frames with shutters (without taking off shutter from frames) not exc. 1.5 sqm each, including cutting holes for removing the hold fast etc (Distrubed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same) complete all as specified and as directed
Taking down chowkats or frames with shutters (without taking off shutter from frames) exc. 1.5 Sqm but n exc 4 Sqm each, including cutting holes for removing the hold fast etc (Distrubed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same) complete all as specified and as directed
Dismantling timber scantlings 40 sq. cm and over in section, in any position as in Framed work etc complete all as specified and as directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out and getting out in hard / dense soil etc complete all as specified and as directed
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth in layers not exceeding 25 cm, and getting out in Hard/Dense soil etc complete all as specified and as directed
M&L Cement concrete type D 2 1:4:8 (using 40 mm graded stone aggregates) as in foundations, filling and mass concrete etc complete all as specified and and as directed
M&L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat with rough finished surface of concrete etc complete all as specified and as directed
M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc for flat with rough finished surfaces of concrete etc complete all as specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs / col hts from 3.50 mtr to 5.00 mtr heights, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) with Rough finished surfaces of concrete (Flat) etc complete all as specified and as directed
M&L for Reinforcement Concrete (Nominal Mix) Type A-1 (1:1.5:3) (using 20 mm grades stone aggregates) as in slabs supported on walls, beam, columns, in floor roofs, landing / lintel beams, deck slab and shelves like etc similar articles, (Working Hts - 3.50 mtr to 4.50 mtr) etc compelete all as specified and as directed
M&L RCC (Nominal mix) type B1, 1:2:4 (20mm graded aggregate), as in foundation incl rafts, fottings, foundation beams, plinth beam, bse for columns etc basement slab under reamed piles and mass concrete etc complete all as specified and directed.
M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips etc complete all as specified and as directed
All as per item No 1.019 above but 6 to 8 mm dia etc complete all as specified and as directed
All as per item no 1.019 above, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and as directed
S&F Steel work in tubular section including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-4923 as in Col, Trusses, Beam, Purlins etc complete all as specified and as directed
M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 etc complete all as specified and as directed
Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts etc complete all as specified and as directed
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified etc complete all as specified and as directed
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges / valley gutters fixed with self tapping screws as specified etc complete all as specified and as directed
M&L for cement concrete 1:2:4 type, B1 using 20 mm graded stone aggregates as in copings, Chajja kerbs, roof padding/staging of water tank etc including necessary fromwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed
M&L for rendering 10 mm thick in CM (1:3) on fair faces of brick work or concrete surface mixed with water proofing compound as per manufacture instruction etc complete all as specified and as directed Notes : WPC shall be measured and paid seperately
M&L for removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth and APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017, 3mm thick and weighing not less than 3.60kg/Sqm reinforced with non woven polyster/HMHDPE matt black finished over compatible primer/bonding bitumen @ 0.40 Litr/Sqm and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer's instructions and applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sqm complete all as specified and directed incl taking down existing roof treatment of any types incl HP clay tiles etc along with cement plastering etc incl removing of debries exc 1.50 Km etc complete all as specified and directed.
M&L Roof tiles, Mangalore pattern, interlocking at side joints, laid and Jointed with cement motar etc complete all as specified and as directed
M&L Ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement 1:6 etc complete all as specified and as directed
M&L for plaster of paris ceiling (Gypsum anhydrous) including sunk or raised moulding or coving, design, pattern as decided by Engr-In-Charge fixed in galvanised grid work including GI suspenders and joints of ceiling board shall be finished with textile tape incl taking down existing false ceiling of any description and in any position etc complete all as specified and directed
M&L for preparing POP false ceiling and applying two coat of plastic emulsion paint over a coat of primer etc complete all as specified and as directed
M&L for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width Type C1 1:3:6(with using 20 mm graded stone aggregates) and setting in CM 1:6 complete all as specified and directed
Plain Cement Concrete,(1:2:4), type B0, 40mm thick as in damp proof course using with and including supply of approved integral liquid water proofing compound as per manufacturers instructions complete all as specified and as directed.
M&L Hardcore of gauge n exc. 63 mm, broken stone or boulder, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface etc complete all as specified and as directed
M&L for M Sand cushioning for paving block tiles etc complete all as specified and directed
M&L for 75 mm thick cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub base of flooing etc complete all as specified and as directed
M&L for 40mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in flooring finished even and smooth without using extra cement etc complete all as specified and as directed
M&L for 25 mm thick Cement concrete type B-0,1:2:4 (12.5mm graded aggregate) as in levelling course of flooing etc complete all as specified and as directed
M&L Screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes complete all as specified and directed
M&L for vitrified ceramic tiles (Dark shade / double charged/ultracharged) 9 to 10mm thick (square/rectangular) polished, area of each tiles exc 0.42 sqm but not exc 1.00 sqm in flooring and vertical surfaces, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed
M&L for machine presssd pre-cast concrete interlocking coloured paving Block of glass fibre reinfoced glossy finished vibro compacted any shape and size confirming to IS-15658-2006 of 60 mm thick, M-35 grade to match with grey cement and pigment etc complete all as specified and as directed
M&L for cement concrete type C-1, 1:3:6 (using 20 mm graded crushed stone aggregate) 75mm thick as in plinth protection, laid in alternate bays (not exceeding 2 Sqm each) finished the concrete surface even and smooth at top without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight all as specified and directed
M&L for Rubber Moulded pre-cast Kerb stones of cement concrete 1:2:4 (20mm graded stone aggregates) factory made, size, shape, pattern and finished as approved, including rounding, chamfered or half round and bedded of perfectely levelled surface pointed and jointed in CM 1:4 etc complete all as specified and as directed
S&F 2nd class hard wood scantling clean sawn surfaces for grid work of wall panelling fixed with nails in the wall incl preparation of wooden surface and applying one coat of Creosote oil etc complete all as specified and as directed
S&F 4 mm thick MFD board, medium density, fibre board single layer type or three layer type with BWR type adhensive, fixed with screws over 0.90 mm thick decorative laminate type 1, of surface finsih, colour and pattern as aprroved, fixed with approved adhesive as per maker's instructions over 8mm thick block boards, grade 1 quality, exterior grade, commercial type, water proof, termite proof, fixed with screws to timber frame work as in wall panelling / cubboard shuttle, shelves over etc complete all as specified and as directed including taking down existing boarding.
M&L for 0.90 mm thick Decorative laminate type 1, of surface finish, colour and pattern as approved, fixed with approved adhesive as per maker's instructions, fixed to door/cub board shutter incl teak wood weading 3mm thick and 12 mm wide incl painting to match the existing colour etc incl taking down existing complete all as specified and as directed incl taking down existing treatment
S&F Powder Coating (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified and as directed
S&F Powder Coating (minimum thickness of powder coating 50 micron) aluminium sliding window and ventilator shutters, with aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified etc. complete all as specified.
S&F Powder Coating (minimum thickness of powder coating 50 micron) aluminium door shutters, aluminium section weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified and as directed '
S & F Sheet glass 4mm thick Tinted glass and glazing with oil putty in squares n exc 0.5 sq. m in each pane etc complete all as specified and as directed
S & F Sheet glass 5.5mm thick tinted glass and glazing with oil putty in squares exc 0.5 sq. m in each pane etc complete all as specified and as directed
S&F in repairs aluminium Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed etc complete all as specified and as directed
M&L for rendering 15 mm thick in CM (1:4) other than fair faces of brick work or concrete or stone masonry surface finsihed even and smooth (without using extra cement) mixed with water proofing compound as per manufacture instruction etc complete all as specified and as directed Notes : WPC shall be measured and paid seperately
M&L for rendering 15 mm thick in CM (1:6) on fair faces of brick work or concrete or stone masonary surface finsihed even and smooth (without using extra cement) etc complete all as specified and as directed
Supply only liquid water proofing compound
Complete removal of existing treatment by means of wire brushing, sand paper, manually or mechanically up to visible of plastered surface incl rubbing and washing etc complete all as specified and as directed
M&L for 1mm thick wall care putty on wall including preparation of surface with sand paper etc to obtain smooth surface etc complete all as specified and as directed
M&L for Preparing new plastered suface of walls and applying two coats distemper oil emulsion, white or tinted over a coat of primer complete all as specified and as directed
All as per item no 1.061 above, but on old Plastered surface of wall
Complete removal of existing treatment of wall and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre / 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre / 10 sqm over new surfaces. etc complete all as specified and as directed
M&L for preparing newly plastered surface of wall and applying two coat of cement base paint over a coat of white wash etc complete all as specified and as directed
M&L for preparing newly plastered surface of wall and applying three coat of white wash etc complete all as specified and as directed
M&L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed
M&L for preparing new concrete surface and applying two coat of synthetic enamel paint over a coat of primer etc complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. with soil complete all as specified and as directed
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point etc complete all as specified and as directed
(E/M PORTION)
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, call bell socket or power circuits), without taking out switches, sockets, regulators, light fittings, etc., complete and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Taking out by unscrewing from boards outlet boxes, fittings & fixtures such as switch socket, ceiling rose , ceiling fiitings, old CFL/FTL / post of lantern tubelight fittings & regulators etc and making good disturbed surface of walls and floors etc.
Taking down carefully copper/alluminium sub main wiring complete and making good disturbed surface of walls and floors etc.
Taking down carefully copper/alluminium sub main wiring complete and making good disturbed surface of walls and floors etc.
Taking down carefully U/S Earth continuity conductor
Taking down carefully unserviceable Earthing complete
Taking down carefully unserviceable DB and MCB of any type
Material and labour for Concealed Point Wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concealed in walls incl MS terminal boxes fabricated with 1.6 mm thick MS sheet, covering with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for One light point controlled by one switch / One fan point controlled by one switch / regulator / one bell / buzzer point controlled by bell push
All as per Serial Item No 2.002 here-in-above, but for one 3 pin socket outlet 5 Amps on indepenedent board.
All as per Serial Item No 2.002 here-in-above, but for one 3 pin socket outlet 5 Amps on Same Board.
Material and labour for Concealed Point Wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concealed in walls incl MS terminal boxes fabricated with 1.6 mm thick MS sheet, covering with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for cable for power switch socket 15 Amps
All as per Serial Item No 2.011 here-in-above, but for 4 Sqmm cable power switch socket 15 Amps.
Taking down unserviceable sub main wiring, supply and fixing Sub main wiring using FRLS grade PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable, 2 runs of single core of size 4 Sq mm and one run of earth continuity conductor of size 4 Sq mm to be drawn through and including PVC non metallic rigid conduit complete all as specified and as directed. NOTE: - Two runs of 4 sq.mm cable, one run of 4 sq mm earth wire and PVC conduite shall be measured as one length.
Taking down unserviceable sub main wiring, supply and fixing Sub main wiring using FRLS grade PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable, 2 runs of single core of size 6 Sq mm and one run of earth continuity conductor of size 6 Sq mm to be drawn through and includin PVC non metallic rigid conduit complete all as specified and as directed. NOTE: - Two runs of 6 sq.mm cable, one run of 6 sq mm earth wire and PVC conduite shall be measured as one length.
Supply and fix in repairs, Modular Switch, One module, One way, 6 Amps, 240 Volts all as specified and as directed.
Shifting of 5KW solar roop top removing and reinstalation where required complete all as specified and as directed.
Supply and Fix ceiling fan1200 mm sweep 5 Star rated service value 6.00 BEE with electronic fon regulator, Three Blade, down rod as per requirement along with all accessaries complete all as specified and directed. Make-HAVELLS (Enticer Art)
Supply and Fix exhaust fan 300 mm sweep with louvers complete all as specified and directed.
Supply and Fix for outdoor type LED post of lantern light fitting of 20 watts comprising of epoxy powder coated hsg, enclosed with glass cover in frame, with protection complete with all accessories and lamp colour white and fixing all as specified and directed. make Havells or eqivalent of Bajaj / CG.
Supply and fix in repairs, MCB single netural (SPN), 440 Volts of capacity 40 Amps all as specified and as directed.
Supply and fix in repairs, MCCB 4 pole 63 Amps, 415 volt, 16 KA all as specified and as directed.
Supply and fix in repairs, Ceiling rose surface type, Bakelite, 65 x 50 mm ISI marked with three terminals all as specified and as directed.
Supply and fix in repairs, MCB SP, 240 volts, 6 to 32 Amps, 50 Hz, 10 KA breaking capacity, 'C' Series, using copper lugs for terminations, complete all as specified and as directed.
Supply and fix in repairs, connecting and testing issolator / MCB single (SP), 440 volts of capacity 6 Amps, complete all as specified and as directed.
Supply and Fix of Double Door TPN DB 4 Way 440 Volt 3 phase MCCB incomer type e with minimum 200 Amps rated Bus Bar including necessary dummy plate.
Supply and Fix of Double Door vertical type DB SPN 8 Way 230 Volt with 200 Amps rated Bus Bar including necessary dummy plate.
S&F 2' x 2' Recess mounted LED Luminaire suitable for Gypsum/ grid type false ceiling of capacity 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make: Bajaj, Cat No : BZRSQL 36W GZI WH / LTCRSLM36WATT2X2 of C & S / HLFPR22-36-CW-R of Halonix
Demolishing of existing earth pits, and providing Material and labour for, earthing complete with Galvanized Iron earth plate electrode 600 mm x 600 mm x 6 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized earth lead wire of 4 mm dia by means of bolts, nuts, Contd/... 2.052
Condt/...2.051 check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery / equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 40 mm bore light grade GI pipe for watering funnel wire mesh, PCC chamber in CC (1:3:6), type C1, manhole cover with RCC (1:2:4), type B1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover and MS frame etc., complete all as specified and as directed NOTE :- Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc. as required 4 mm dia galvanised iron or steel wire
XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor 1100 volts grade cross-sectional area 10 Sqmm 3.5 core in trenches / ducts /Wall / through pipe / on pole / roads fixing to the poles through clamps and connecting up, testing and commissioning including taking down old unserviceable LT UG cables jointing and testing complete all as directed
Atom Engineers and Builders
PRANAVI CONSTRUCTION
J PUSHPALATHA ENGINEER AND CONTRACTOR
Sangam Construction
MAA ENGINEERING SERVICERS
ADWITHI
ABHISHEK CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .