Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAccepted-AOC AT SAMET ELECTRO TOWER TAMRIT MARKET COMPLEX ROOM NO 15 HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | TALCHER | ANGUL | ODISHA | 759100 | ₹4.5 L | L1 | Accepted-AOC Technocommercially eligible L1 bidder |
| 2 | Rejected-Technical AT FCI TOWNSHIP PO VIKRAMPUR DIST ANGUL ODISHA PIN 759106 | VIKRAMPUR | ANGUL | ODISHA | 759106 | - | - | Rejected-Technical Rejected for not being L1 |
| 3 | Rejected-Technical AT FCI LAXMI BAZAR TALCHER PO VIKRAMPUR DIST ANGUL ODISHA 759117 | TALCHER | ANGUL | ODISHA | 759117 | - | - | Rejected-Technical Rejected for not being L1 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected for not being L1 |
| 5 | Rejected-Technical | - | - | Rejected-Technical Rejected for not being L1 |
Tender Value
₹7.0 L
EMD Value
₹8,800
Closing Date
26 Jun 2024, 5:00 pmClosed
Staff Officer(EnM), Jagannath Area, MCL
Jay Prakash, Staff Officer(EnM), Jagannath Area, MCL PH 06760-269717, 06670-269751(Extn)2023 Fax 06760-269527 E-mail so-enm-jaga.mcl(at)coalindia.in
Renovation of Indoor Electrical Rewiring and illumination system of OLD office building at 132/33 KV Sub-station, Nandira, Jagannath Area.
2024_MCL_310457_1
GM(JA)/EnM/e-Tender/24-25/ E-664/29 DTD.14/06/24
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
TALCHER
AS PER NIT
4 documents required · 4 mandatory
₹8,800
5 Sept 2024
14 Jun 2024
28 Jun 2024
15 Jun 2024
26 Jun 2024
15 Jun 2024
15 Jun 2024 - 19 Jun 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 Amp Switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 Amp Socket outlet
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2X2.5 Sq.mm + 1X2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2X4 Sq.mm + 1X4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel,MOB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door
Supplying, installing, testing and commissioning of following capacity End Feed Unit made of 1.6mm thick sheet steel enclosure duly painted with powder coating to existing rising mains complete with TPN disconnector FSU and HRC fuses, mounting stands, cable end box, brass compression gland, connections, earthing etc. as required. 200A TPN
Supplying of one number PVC insulated and PVC sheathed / XLPE Allumium power cable of 1.1 KV grade as required 4X70 sq.mm,(300 mtrs) [DEPRATMENTAL SUPPLY]
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 35 sq. mm and upto 95 sq. mm
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63A
Supplying & fixing 5 amps to 32 amps rating, 240/415 V "C" curve, miniature circuit breaker suitable for inductive load of following poles in th existing MCB DB complete with connection, testing and commisioning etc. as required. Single Pole and neutral, 32 Amp
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth,metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete withconnections, testing and commissioning etc. as required.
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commisioning etc. as required Upto 450 mm sweep.
Supplying of exhaust fan 200 mm sweep, 1400 rpm, 230volts, 70 W, double ball bearing copper wound with bird guard to protect the fan in running condition and Double ball bearings heavy duty motor complete set as required.
Supplying Ultra modern recess mounting 36 watt luminaire with high performance LEDs, suitable for mounting with Armstrong/ Grid ceiling as required. Fixture size :(LxWxH) in (595x595x65)mm
Supplying surface and wall mounted LED batten with polycarbonate housing & integrated elctronic driver as required. 1X 22 Watt(14 nos)[Departmental Supply]
Supplying and installation of wall mounting fan,400 mm sweep , 230 V AC as required.
Installation,testing and commissioning of pre-wired, fluorescent fitting/ compact fluroscent fitting of all types, complete with allaccesories and tube etc. directly on celling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated , copper conductor, single core cable and earthing etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
J.N. RAY
M/S MAA ELECTRICALS
S.N. ENTERPRISES
M/s. Sahida Electrical Works
GAGAN BIHARI BISWAL
JEET ELECTRICALS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .