Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.0 LAccepted-AOC | L1 | Accepted-AOC Found lowest | |
| 2 | L2₹14.2 L+₹26,825.10 (1.92%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Not Found lowest | |
| 3 | L3₹14.3 L+₹37,559.15 (2.69%)Rejected-Finance | L3 | Rejected-Finance Not Found lowest | |
| 4 | L4₹17.5 L+₹3.5 L (25.1%)Rejected-Finance | L4 | Rejected-Finance Not Found lowest | |
| 5 | L5₹19.8 L+₹5.8 L (41.9%)Rejected-Finance | L5 | Rejected-Finance Not Found lowest |
| Sl No | Description | Qty | Unit | G.M. ENGINEERING SERVICES L4 | KALSI CONSTRUCTION CO L7 | kailu construction co L2 | dinesh enterprises L1 | KHAJURIA ENGINEERS L6 | M/s. Aggarwal Engineers L5 | ANIL ENTERPRISES L3 | Durga Electricals L8 | M/S Raghuvanshi Builders L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Maintenance and repair to existing street/perimeter security lights fittings/solar lights etc of any type/size/wattage from date of work order/physically handing over site to contractor as nature the work is of urgent requirement keeping security of areas and any specifications, fittings/fixed of poles, buildings or watching towers of any heights, finding faults in LT feeder and light fittings, liasoning with connectioning sub station of MES, reporting to concerned JE E/M and Engr-in-Charge about the faults complete manpower for repair including rectifying the same by replacing defective spare parts as per direction by concerned JE E/M and Engr-in-Charge at various location complete all as specified and directed for OTM accn at Madhopur, NCSSR & Bucthary complex.
Note: 1. Spare parts of light fitting/fitting shall be measured and paid separately under relevant items of Schedule 'A' as supply only as per requirement for repair/replacement however providing manpower on daily basis as quoted above. | 350 | Each Job | 60 ₹21,000 | 100 ₹35,000 | 200 ₹70,000 | 40 ₹14,000 Lowest | 85 ₹29,750 | 200 ₹70,000 | 190 ₹66,500 | 50 ₹17,500 | 50 ₹17,500 |
| 2.00 | Supply only LED street light driver of capacity 25 to 40 watt, make of LED driver as per suitable light fitting of make and type as per sample complete all as specified and directed. | 40 | Each | 300 ₹12,000 | 250 ₹10,000 | 150 ₹6,000 | 120 ₹4,800 Lowest | 550 ₹22,000 | 300 ₹12,000 | 150 ₹6,000 | 180 ₹7,200 | 240 ₹9,600 |
| 3.00 | Supply only LED street light driver of capacity 45 to 60 watt, make of LED driver as per suitable light fitting of make and type as per sample complete all as specified and directed. | 40 | Each | 300 ₹12,000 | 300 ₹12,000 | 150 ₹6,000 Lowest | 200 ₹8,000 | 600 ₹24,000 | 350 ₹14,000 | 150 ₹6,000 Lowest | 180 ₹7,200 | 250 ₹10,000 |
| 4.00 | Supply onlyLED street light driver of capacity 70 to 100 watt, make of LED driver as per suitable light fitting of make and type as per sample complete all as specified and directed | 10 | Each | 300 ₹3,000 | 450 ₹4,500 | 150 ₹1,500 Lowest | 220 ₹2,200 | 650 ₹6,500 | 500 ₹5,000 | 150 ₹1,500 Lowest | 320 ₹3,200 | 310 ₹3,100 |
| 5.00 | Taking out old U/S damaged street light fittings and M & L for Providing street light fitting of capacity 90 Watt LED fitting, 5700 K made up of pressure die cast aluminium housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 complete including 2 RM, 3 core, 1.5 Sqmm copper wire for each light fitting, complete all as specified and directed.Make-Wipro, cat part no : LR02-102-XXX-57-G2/Crompton, cat part no :TRP-425-90-57-HL2-LM-NBK/Orient, cat part no : LSFS-090-C/Polycab, cat part no: PCGLS C4 90 W complete all as specified and directed. | 60 | Each | 3,376 ₹2,02,560 | 4,000 ₹2,40,000 | 2,700 ₹1,62,000 Lowest | 3,300 ₹1,98,000 | 4,200 ₹2,52,000 | 3,100 ₹1,86,000 | 2,800 ₹1,68,000 | 4,985 ₹2,99,100 | 5,980 ₹3,58,800 |
| 6.00 | Taking out old U/S damaged street light fittings and M & L for Providing street light fitting of capacity 60 Watt LED fitting,5700 K new generation energy saving and environmental friendly long life LED street light fitting made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeddedPC cover with IP65 protection and impact resistance of IK07 complete including 2 RM, 3 core, 1.5 Sqmm copper wire for each light fitting etc complete all as specified and directed. Havells Cat Part ENDURASUNDOWNSL60WLED765PASYBOTG/Wipro , cat part no : LR02-671-XXX-57-G3 / Crompton ,cat part no :TRP-421-60-57-SL-LM-NBK/Orient, cat part no : LSFS-060-C complete all as specified and directed. | 20 | Each | 2,668 ₹53,360 | 2,650 ₹53,000 | 1,900 ₹38,000 Lowest | 2,800 ₹56,000 | 3,300 ₹66,000 | 2,100 ₹42,000 | 2,000 ₹40,000 | 3,078 ₹61,560 | 4,870 ₹97,400 |
| 7.00 | Taking out old U/S damaged street light fittings and M & L for Providing street light fitting of capacity 70 Watt LED fitting,5700 K energy saving and environmental friendly long life LED street light fitting made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP65 protection and impact resistance of IK07 complete including 2 RM, 3 core, 1.5 Sqmm copper wire for each light fitting etc complete all as specified and directed. Havells Cat Part ENDURASUNDOWNSL70WLED765PASYBOTG/Wipro , cat part no : LR02-681-XXX-57-G3/ Crompton , cat part no :TRP-421-70-57-SL-LM-NBK complete all as specified and directed. | 40 | Each | 2,753 ₹1,10,120 | 3,000 ₹1,20,000 | 2,000 ₹80,000 Lowest | 2,700 ₹1,08,000 | 3,500 ₹1,40,000 | 2,650 ₹1,06,000 | 2,200 ₹88,000 | 4,295 ₹1,71,800 | 5,600 ₹2,24,000 |
| 8.00 | Taking out old U/S damaged flood light/street light fittings and M & L for Providing LED Flood Light luminaire in pressure die-cast aluminium housing with IP66 protection of capacity 70 watts, 230 volts, 50 Hz, area lighting including 70 watts LEDs and driver of make: Havells Cat Part JETALEGANZAFLS70WLED757P60DTOTG/Cromton, cat part No : TFS-504-100-57-NL-SL-GL-NBK/Orient, cat part no : LFSMU-070-C complete all as specified and directed. | 30 | Each | 3,483 ₹1,04,490 | 4,800 ₹1,44,000 | 2,000 ₹60,000 Lowest | 2,000 ₹60,000 Lowest | 4,100 ₹1,23,000 | 3,050 ₹91,500 | 3,000 ₹90,000 | 4,602 ₹1,38,060 | 5,950 ₹1,78,500 |
| 9.00 | Taking out old U/S damaged flood light/street light fittings and M & L for Providing LED Flood Light luminaire in pressure die-cast aluminium housing with IP66 protection of capcity 100 watts, 230 volts, 50 Hz, area lighting including 100 watts LEDs and driver. Make of flood light: Havells Cat Part JETALEGANZAFLS100WLED757P60DTOTG/ Cromton, cat part no :TFS-504-70-57-60D-SL-GL-NSG/Orient, cat part no : LFSMU-100-C complete all as specifed and directed. | 30 | Each | 3,730 ₹1,11,900 | 6,200 ₹1,86,000 | 2,800 ₹84,000 | 2,400 ₹72,000 Lowest | 4,900 ₹1,47,000 | 3,500 ₹1,05,000 | 3,000 ₹90,000 | 6,596 ₹1,97,880 | 8,500 ₹2,55,000 |
| 10.00 | Supply and fix in replacement of three core copper conductor multi-stranded type PVC insulated and sheathed of 1.5 sqmm, 1100 volts grade and connected to the street light from over head line or Junction boxes complete all as specified and directed. | 200 | RM | 20 ₹4,000 | 20 ₹4,000 | 20 ₹4,000 | 10 ₹2,000 Lowest | 52 ₹10,400 | 115 ₹23,000 | 20 ₹4,000 | 50 ₹10,000 | 35 ₹7,000 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
10 Jul 2025, 6:00 pmClosed
Lt Col Nitin Bisht
GE Basoli PO Lakhanpur Distt Kathua (JK) 184152
GE/BAS-34/2025-26 Repair and Maintenance of security lights, road lights, solar lights and standby generator sets at Madhopur station under GE Basoli
2025_MES_713868_1
GE/BAS-34/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Madhopur station under GE Basoli
As per tender docs
8 documents required · 8 mandatory
₹500
GE Basoli
₹60,000
Yes
14 Aug 2025
12 Jun 2025
12 Jul 2025
12 Jun 2025
10 Jul 2025
26 Jun 2025
Amount
Maintenance and repair to existing street/perimeter security lights fittings/solar lights etc of any type/size/wattage from date of work order/physically handing over site to contractor as nature the work is of urgent requirement keeping security of areas and any specifications, fittings/fixed of poles, buildings or watching towers of any heights, finding faults in LT feeder and light fittings, liasoning with connectioning sub station of MES, reporting to concerned JE E/M and Engr-in-Charge about the faults complete manpower for repair including rectifying the same by replacing defective spare parts as per direction by concerned JE E/M and Engr-in-Charge at various location complete all as specified and directed for OTM accn at Madhopur, NCSSR & Bucthary complex. Note: 1. Spare parts of light fitting/fitting shall be measured and paid separately under relevant items of Schedule 'A' as supply only as per requirement for repair/replacement however providing manpower on daily basis as quoted above.
Supply only LED street light driver of capacity 25 to 40 watt, make of LED driver as per suitable light fitting of make and type as per sample complete all as specified and directed.
Supply only LED street light driver of capacity 45 to 60 watt, make of LED driver as per suitable light fitting of make and type as per sample complete all as specified and directed.
Supply onlyLED street light driver of capacity 70 to 100 watt, make of LED driver as per suitable light fitting of make and type as per sample complete all as specified and directed
Taking out old U/S damaged street light fittings and M & L for Providing street light fitting of capacity 90 Watt LED fitting, 5700 K made up of pressure die cast aluminium housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 complete including 2 RM, 3 core, 1.5 Sqmm copper wire for each light fitting, complete all as specified and directed.Make-Wipro, cat part no : LR02-102-XXX-57-G2/Crompton, cat part no :TRP-425-90-57-HL2-LM-NBK/Orient, cat part no : LSFS-090-C/Polycab, cat part no: PCGLS C4 90 W complete all as specified and directed.
Taking out old U/S damaged street light fittings and M & L for Providing street light fitting of capacity 60 Watt LED fitting,5700 K new generation energy saving and environmental friendly long life LED street light fitting made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeddedPC cover with IP65 protection and impact resistance of IK07 complete including 2 RM, 3 core, 1.5 Sqmm copper wire for each light fitting etc complete all as specified and directed. Havells Cat Part ENDURASUNDOWNSL60WLED765PASYBOTG/Wipro , cat part no : LR02-671-XXX-57-G3 / Crompton ,cat part no :TRP-421-60-57-SL-LM-NBK/Orient, cat part no : LSFS-060-C complete all as specified and directed.
Taking out old U/S damaged street light fittings and M & L for Providing street light fitting of capacity 70 Watt LED fitting,5700 K energy saving and environmental friendly long life LED street light fitting made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP65 protection and impact resistance of IK07 complete including 2 RM, 3 core, 1.5 Sqmm copper wire for each light fitting etc complete all as specified and directed. Havells Cat Part ENDURASUNDOWNSL70WLED765PASYBOTG/Wipro , cat part no : LR02-681-XXX-57-G3/ Crompton , cat part no :TRP-421-70-57-SL-LM-NBK complete all as specified and directed.
Taking out old U/S damaged flood light/street light fittings and M & L for Providing LED Flood Light luminaire in pressure die-cast aluminium housing with IP66 protection of capacity 70 watts, 230 volts, 50 Hz, area lighting including 70 watts LEDs and driver of make: Havells Cat Part JETALEGANZAFLS70WLED757P60DTOTG/Cromton, cat part No : TFS-504-100-57-NL-SL-GL-NBK/Orient, cat part no : LFSMU-070-C complete all as specified and directed.
Taking out old U/S damaged flood light/street light fittings and M & L for Providing LED Flood Light luminaire in pressure die-cast aluminium housing with IP66 protection of capcity 100 watts, 230 volts, 50 Hz, area lighting including 100 watts LEDs and driver. Make of flood light: Havells Cat Part JETALEGANZAFLS100WLED757P60DTOTG/ Cromton, cat part no :TFS-504-70-57-60D-SL-GL-NSG/Orient, cat part no : LFSMU-100-C complete all as specifed and directed.
Supply and fix in replacement of three core copper conductor multi-stranded type PVC insulated and sheathed of 1.5 sqmm, 1100 volts grade and connected to the street light from over head line or Junction boxes complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and not exc 1.5 mtr deep and getting out in any type of soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
Returning filling in (soil) including spreading levelling, watering and well ramming in layers not exc 25 cm thick each complete all as specified and directed.
Supply & laying of approved quality sand under cable upto 15cm before laying the cable and 8cm over the cable after laying, punned down to overall thickness of 18cm in trenches for cable cushioning complete all as specified and directed. (Note: Punned thickness shall be measured)
Material and labour for well burnt, old size Sub Class 'B' brick covering protection to the electric cable laid dry flat transversally along the length of cable with width equal to length of brick complete all as specified and directed.
S&F in replacement GI pipe 50mm bore (Light grade) for protection of LT cable fixed to walls/ poles/road crossing including suitable size clamps complete all as specified and directed
Supply and fixing for XPLE insulated screened,PVC bedded galvanised steel strip & wire armoured electric power cable (heavy duty) 1100 volts grade of size 50 sqmm, 3.5 core with stranded aluminium conductor including proper connection to LT panel/bus bar with aluminium thimbles of suitable size/rating laid in trenches through pipe or under culvert including taking out existing cables/UNSV AI conductor, complete all as specified and directed. (Note – Necessary excavation, returning, filling in, removal of soil, sand cushioning, brick cover work and GI pipe shall be measured and paid seperately under respective item of BOQ).
Supply and fixing for XPLE insulated screened, PVC bedded galvanised steel strip & wire armoured electric power cable (heavy duty) 1100 volts grade of size 25 sqmm, 4.0 core with stranded aluminium conductor including proper connection to LT panel / bus bar with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables/UNSV AI conductor, complete all as specified and directed. (Note – Necessary excavation, returning, filling in, removal of soil, sand cushioning,brick cover work and GI pipe shall be measured and paid seperately under respective item of BOQ).
Supply and fixing for XPLE insulated screened, PVC bedded galvanised steel strip & wire armoured electric power cable (heavy duty) 1100 volts grade of size 16 sqmm, 4.0 core with stranded aluminium conductor including proper connection to LT panel/bus bar with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables/UNSV AI conductor, complete all as specified and directed. (Note – Necessary excavation, returning, filling in, removal of soil, sand cushioning, brick cover work and GI pipe shall be measured and paid seperately under respective item of BOQ).
Supply and fixing for XPLE insulated screened,PVC bedded galvanised steel strip & wire armoured electric power cable (heavy duty) 1100 volts grade of size 16 sqmm, 2.0 core with stranded aluminium conductor including proper connection to LT panel/bus bar with aluminium thimbles of suitable size/rating laid in trenches through pipe or under culvert including taking out existing cables/UNSV AI conductor, complete all as specified and directed. (Note – Necessary excavation, returning, filling in,removal of soil, sand cushioning, brick cover work and GI pipe shall be measured and paid seperately under respective item of BOQ).
Supply and fixing for XPLE insulated screened, PVC bedded galvanised steel strip & wire armoured electric power cable (heavy duty) 1100 volts grade of size 10 sqmm, 2.0 core with stranded aluminium conductor including proper connection to LT panel/bus bar with aluminium thimbles of suitable size /rating laid in trenches through pipe or under culvert including taking out existing cables/UNSV AI conductor, complete all as specified and directed. (Note – Necessary excavation, returning, filling in,removal of soil , sand cushioning, brick cover work and GI pipe shall be measured and paid seperately under respective item of BOQ).
M & L for 1100 volts grade heavy duty cable PVC insulated aluminum conductor of size 16 Sqmm served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm dia suspensions wire including taking down old unserviceable complete all as specified and directed.
M & L for 1100 volts grade heavy duty cable PVC insulated aluminum conductor of size 10 Sqmm served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm dia suspensions wire including taking down old unserviceable complete all as specified and directed.
Supply and fix in Replacement of junction box of minimum size 30cm (height)x20 cm (width)x15 cm (depth) made of steel sheet 1.6 mm thick duly painted with two coat of synthetic enamel paint over a coat of red oxide primer having aluminium bus bar 4 Nos of capacity 63 Amps with minimum 04 Set of nuts, bolts & washers on each busbar mounted on porcelain/PVC insulator having 01 No MCB, SP, 16 Amps. Junction box shall be fixed on pole & including suitable, MS strip, nuts, bolts & washers suitable for bottom entry of cable of size upto 25 sqmm including suitable cable glands, thimbles complete all as specified and directed.
S&F structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including, nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat, one finishing coat of aluminium paint and epoxy coating, including taking down old corroded structural steel complete all as specified and directed.
Comprehensive maintenance and repair of diesel engine of DG sets 62.5 KVA capacity installed at various locations, by periodical servicing maintenance as per OEM recommendations, repair including replacement of defective/unserviceable spare parts, tracing & removing of any fault/error indication or meassage showing/ indicating on display screen, greasing to doors/over hauling to various parts, cleaning of DG set, inspecting the serviceability of all parts and testing on full load after periodical service/repair by manufacturer's authosied workshop, complete all as specified and as directed by Engineer-In-Charge. (Spare Parts shall be measured and paid for seperately under respective items. The maintenance of above mentioned DG sets carried out will be measured as one unit)
All as per Srl Item No 26 above but DG Set of 40 KVA/30 KVA capacity complete all as specified and as recommanded by BOO (Note: The maintenance of above mentioned DG set carried out will be measured as one unit) Notes for Sr Item No 26 to 27 (i) New spare parts and engine oil shall be measured and paid separately under respective items.(ii) Labour charges for replacement of old engine oil and old defective spare parts shall be deemed included in quoted rates. (iii) Cost of routine lubrication/ greasing to spare parts, lubricants/grease, tightening of nut, bolts and washers etc. shall deemed to be included in quoted rates.(iv) Cost of fixing and transportation of all components/ spare parts required being repair, of DG sets from site to workshop for repair and workshop to site after repair shall be deemed included in quoted rates. (v) Periodical routine maintenance/ checkup of diesel generator sets shall be carried out as per TI-04 of 1984 and maintenance record, prepared/ maintained by contractor and signed by concerned JE E/M, Engineer-In-Charge and Contractor. This maintenance record shall be produce to Garrison Engineer whenever asked. (vi) Periodical routine maintenance/ checkup of diesel generator sets shall be carried out as per following periodicity:a) Stage-I (Monthly): (i) Cleaning of air cleaner/ filter. (ii) Changing of lubricants and oil filter elements. (iii) Cleaning of fuel tanks and cleaning of fuel filter elements. (iv) Cleaning of radiator cooling fins and top up of coolant. (v) Cleaning of line cylinder head fins, in case of air cooled engines. (vi) Checking of all electrical instruments/indicating or any other gauge i.e. frequency meter,voltmeter, ammeter, revolution meter, Hrs run meter, water temp gauge, fuel gauge etc for satisfactory functioning. (b) Stage-II (Quarterly): (i) Changing of engine oil, if required, and clean the pre-cleaner bowl.(ii) Check/ open radiator fins, and clean, if chocked/ blocked. (iii) Check button filter in banjo bolt of feed pump. (iv) Drain the water from water separator, if provided. (v) Check all external fasteners as per specified torques. (vi) battery lead connections. (vii) Check belt alignment and belt condition. (viii) Check turbo changer. (ix) Leakage in air take/ exhaust of exhaust piping (x) Lubrication to the turbo charger,Oil filter.
Replacement of existing UNSV parts with new parts (fixing shall be paid against Srl item No. 26 of DG set 62.5/50 KVA (a) Fuel Filter
(b) Oil filter
(c) Fan belt
(d) Hose pipe with two Nos. of metallic clips
(e) Diesel pipe(steel) with banjo connection.
(f) Air filter
Replacement of existing UNSV parts with new parts (fixing shall be paid against Srl item No. 27 of DG set 40/30 KVA (a) Fuel Filter
(b) Oil filter
(c) Fan belt
(d) Hose pipe with two Nos. of metallic clips
(e) Diesel pipe(steel) with banjo connection.
( f) Air filter
Replacement of coolant fluid of make as approved by Engr-in-Charge suitable for radiator of DG set of any capacity/make complete all as specified and directed.
Replacement of Engine oil/ lubricant, 20 W 40 grade or any other grade as recommended by OEM of Engine or Engr-in-Charge suitable for DG set of any capacity and any make, complete all as specified and directed.
Suppy only distill water for battery of DG Set etc complete all as specified and directed.
Supply and fix in Replacement of battery 12 volt, 120 AH heavy duty maintenance free incl initial charged complete in all respects complete all as specified and directed.
Supply and fix in Replacement of battery 12 volt, 150 AH heavy duty maintenance free incl initial charged complete in all respects complete all as specified and directed.
S&F of bracket made out of 1.5M long 50mm dia light grade galvanished iron steel tubing for fixing light fitting including dismantling taking out old U/S complete all as specified and directed.
M&L earthing complete with galvanised steel earth plate eletrode 600mmx600mm and 6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edges, of the plate not less than 1.5m below normal ground level, connected to the Galvanise Iron earth lead 32mmx6mm (GI Strip) size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6 mm earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4), reinforced with XPM (weight not less than 4 kg per sqmm) and frame of angle iron 40mmx40mmx3mm and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe of suitable length for watering perforated at bottom placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exceeding 50 mtr and removal of surplas soil to plate No 3 of SSR 2009 Part-I and connecting to feeder pillers and Transformer all as specified including testing on completion complete all as specified and directed.
Taking out the unsv alternator of DG Sets 30 KVA to 63 KVA and shifting to workshop for rewinding of armature including replacement of unserviceable, bushes & minor parts & reinstalling the same after testing complete as specified.
M&L cleaning of diesel tank of DG Set of any capacity including replacement of worn-out pipe line and measuring scale and fixing in original position and make it leak proof with necessary clamps complete all as specified and directed.
Supply only Battery Terminals heavy duty Copper.(Positive & Nagative) complete all as specified and directed.
Supply only Radiator hose pipe for DG Set complete all as specified and directed.
S&F in replacement water pump assembly with DEL Body of 30 KVA to 62.5 KVA, capacity complete all as specified and directed.
M & L for replacement fan assembly suitable for DG Set of 32 KVA to 62.5 KVA capacity complete all as specified and directed.
Overhauling of radiator assembly of 30 KVA to 62.5 KVA DG set by disconnecting and removing from the engine, dismantling the top and bottom chambers, descaling the sediments, scales, corrosion etc. by means of acid, cleaning and high pressure water washing, air cleaning, re-assembling the same with new gaskets including arresting leakages, if any and fixing to the engine with new hoses, clips etc. all as required and as directed.Note: The rate quoted shall be inclusive of transporting of the radiator to the workshop and back and all incidental charges.
Supply and replacement of AVR (automatic voltage regulator) suitable for 30 KVA to 62.5 KVA DG set complete all as specified and directed.
Material and labour for control panel of DG set for operating the DG set including pressure gauge, lub oil gauge, KWH meter, start stop button, RPM meter including replacement of internal control wiring, controller, Relay card, MPU, resistance kit and fixing the panel on the top of the DG set on angle iron frame complete all as specified and directed.
Supply and fixing for bus bar chamber, 3 phase 415 volts, 4 ways having aluminium bus bar of capacity 200 amps, fixing on angle iron 40x40x5mm including PCC 1:3:6 complete all as specified and directed. Make of bus bar chamber: Havells, cat part no: IHBC020004 or technocommerically equivalent to Legrand /ABB/C&S/Schneider.
kailu construction co (BID ID -3345899)
ANIL ENTERPRISES (BID ID -3354133)
G.M. ENGINEERING SERVICES (BID ID -3345277)
M/s. Aggarwal Engineers (BID ID -3354361)
KHAJURIA ENGINEERS (BID ID -3345008)
KALSI CONSTRUCTION CO (BID ID -3345488)
Durga Electricals (BID ID -3353899)
M/S Raghuvanshi Builders (BID ID -3344325)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .