| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC RZ 40 PALAM VIHAR DWARKA SECTOR 6 NEW DELHI 75 | NEW DELHI | DELHI | 75 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹39.1 L+₹9.7 L (32.8%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹42.9 L+₹13.4 L (45.6%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹48.4 L+₹18.9 L (64.2%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹50.1 L+₹20.6 L (69.9%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹47.1 L
EMD Value
₹94,200
Closing Date
5 Sept 2022, 6:00 pmClosed
ARJUN PATRO,IDSE
GE U ELECTRIC SUPPLY,DELHI CANTT
REPAIR AND MAINTENANCE OF LT CABLE, LT POLE EARTHING FENCING AND CONNECTED WORKS AT KARAM VIHAR MAP, 285 FD WKSP, 261 AB TIGRIS ROAD MAP, SUMRAN LINE, NPG LINE, MAUDE LINE, SANYAT LINE, PANCHWATI DAD, NSB III, 20 PUNJAB, 147 FD WKSP, 15 GRENADIERS, 2
2022_MES_534080_1
GE ELECT/D-47/2022-2023
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE U ELECTRIC SUPPLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹94,200
Yes
12 Dec 2022
30 Jul 2022
7 Sept 2022
30 Jul 2022
5 Sept 2022
24 Aug 2022
Amount
Dismantling broken concrete/steel poles, any size complete all as directed by Engr-in-charge
Taking down of existing street light from item No 1 above and fixing on new poles complete all as directed by Engr-in-charge
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
All as per srl item No 7 here-in-before but using old bricks obtained under srl item No 3 here in before.
Demolition of road, path, drain and concrete in ground floors, RCC/Brick wall (below or above ground level) complete all as specified and as directed.
M&L for providing cement concrete 1:2:4 type B-2 (using 40 mm grade crushed stone aggregate) 80 mm Thick complete all as specified and as directed by Engr in charge.
Trimming and cutting of tree branches (not more than 25mm girth) coming across LT over head line clearing the line around 2m single/both sides and disposal of branches from site exceeding 50m and not exceeding 250m from site complete all as directed by Engr-in-Charge. Note :- (i) Length of span is approx 25 to 50 RM. (ii) Due care is to be given while trimming/cutting the tree branches that there should no damage to over head line conductor/pole. In case due to any negligence, damage is caused to be make good/ renewal by the contractor from his own resources and nothing extra is admissible. (iii) All safety to laborer must be adhered by the contractor during trimming and cutting of tree branches.
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
16 Sqmm 4 core
25 Sqmm 4 core
35 Sq mm 3.5 core.
50 Sq mm 3.5 core.
70 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
400 Sqmm 3.5 core
400 Sqmm single core
Boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends all specified and directed
S&F in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah of following bore sizes
Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required. Note: (a) 1100 Volt LT cable & joints shall be measured and paid for separately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs. (c) Excavation and earth work will be measured and paid for separately under respective items of schedule.
Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminum conductor 1100 Volts grade complete all as directed for the following sizes :-
25-50 Sqmm x 3.5 core/ 4 core
70-150 Sqmm x 3.5 core
185 -300 Sqmm x 3.5 core
Supply & installing steel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II) including excavation, earth work, PCC foundation, base plate,PCC coping,G I pipe for cable protection etc. and GI bracket for fitting mounting, complete all as per manufacturer's instructions and as specified and as directed by Engg-in-charge. NOTE:- 1.The unit rate in this item is deemed to be included the cost of ,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole . The steel pole shall be painted by bituminous paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminum paint over a coat of red oxide complete all as specified and directed. 2. Excavation, earth work and GI brackets will measured and paid separately under relevant item .”
Supply & Fixing in replacement bracket for street light fitting complete with 1.5 to 2.2 mtr long 32/40mm dia GI pipe medium grade and including necessary mild steel clamp , nuts, bolts and washers and painting on steel surfaces with two coats of aluminum paint complete as as specified and directed.
Material and labor disconnecting faulty /burnt end or portion of cable by removing the cable from loop including necessary excavation & earth work , suitable size of thimble LT tap , relaying and reconnecting the cable by removing faulty/burnt portion of cable and preparing fresh terminals for 25 Sqmm 3.5/4 core to 240 Sqmm 3.5 core of LT cable to LT Panel/pole/main switch complete all as directed.
Supplying and fixing in replacement MCB DP , 63 Amps,50 Hz,10 KA,240 Volts complete as as specified and directed.
Supplying and fixing in replacement MCB SP , 6 to 32 Amps,50 Hz,10 KA,240 Volts complete as as specified and directed.
S&F in replacement KIOSK box weather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amps including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red color on front face of KIOSK box body complete all as specified and directed.Incluiding MS clamp of size 25x3 mm with suitable size nut, bolts & washer.
M&L for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminum paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed.
Earthing in replacement complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32 X6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanized ironsides complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Supply and fix in replacement of UNSV MCCB 4 pole of following capacity, 415 volts 50 Hz AC with thermal and magnetic release fixed in any type of existing LT panel/Feeder pillar including taking out old existing UNSV MCCB from panels etc complete all as directed .
MCCB 630 Amp 50 KA.
MCCB 400 Amp 36 KA.
MCCB 320 Amp 36 KA.
MCCB 250 Amp 36 KA.
MCCB 200 Amp 25 KA.
MCCB 160 Amp 25 KA.
MCCB 125 Amp 25 KA.
MCCB 100 Amp 25 KA.
MCCB 63 Amp 25 KA.
Supply and fix in replacement of UNSV MCCB 3 pole of following capacity , 415 volts 50 Hz AC with thermal and magnetic release fixed in any type of existing LT panel/Feeder pillar including taking out old existing UNSV MCCB from panels etc complete all as directed .
MCCB 630 Amp 50 KA.
MCCB 400 Amp 36 KA.
MCCB 320 Amp 36 KA.
MCCB 250 Amp 36 KA.
MCCB 200 Amp 25 KA.
MCCB 160 Amp 25 KA.
MCCB 125 Amp 25 KA.
MCCB 100 Amp 25 KA.
MCCB 63 Amp 25 KA.
Supply and fix in replacement outdoor type wall mounted Busbar chamber having 04 pole busbar of rating 200 amps fitted with MCCB 100 Amp, 4 pole , 25 KA, 50 Hz as incomer including suitable hole in bus bar for outgoing cable connection including suitable size nut bolt and fasyner complete all as directed at site by Engr -in-charge.
Supply, installing, testing and commissioning in replacement of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement of size not less than 400mm x 400mm x 300mm with 4 Nos 400 Amps aluminum bus bar and with 250 Amp MCCB, 4 pole, 25 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded stone aggregate, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded stone aggregate on top and grouting bolts etc for Bus bar chamber. The platform shall be such that it is of a height 45 cm above the nearest road level.
Supply in replacement and Installation of LT CT operated Trivector Meter with the following specifications:- (a) Meter Type: LT 3 Phase 4 Wire Electronic Tri vector Meter (b) Standard: IS 13779:1999 / CBIP 88 (c) Accuracy: Class 0.5 (d) Voltage and Current rating:- (i) Reference Voltage - 3x240 V (ii) Basic Current (Ib) - 5 A (iii) Maximum continuous current (Imax) - 10 A (e) Rated Frequency (variation) - 50Hz (±5%) (f) Power consumption:- (i) Voltage circuit: Less than 1.5 W and 10 VA per Phase at reference voltage, reference temperature and reference frequency (ii) Current circuit: Less than 1 VA per phase at basic current, reference frequency and reference temperature (g) Display type: 8 digit 7 segment backlit LCD display, not less than10 mm character height (h) Display in the event of Power Failure: Internal battery back-up for LCD display (j)Communication port: (i) Galvanically isolated Optical Communication port for data transfer through either CMRI or remote device or both is provided (ii) RS 485 for DLMS protocol (iii) Energy recording - Unidirectional
Supply drawing, connecting and testing of 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed copper conductor (flexible ) industrial cable, 1100 Volts conforming to IS 694 in steel tubular poles from KIOSK box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
Taking down existing worn out/old/broken ACSR conductors of any size and length at any position from LT poles and supply, fixing and stretching new ACSR conductors of any size and type for over head LT poles including binding at site to insulator with suitable size of binding wire etc complete all as specified and directed by Engr in charge.
Material and labor for carrying out balance distribution of load on LT Lines by checking the existing load on the feeder (3 phase,4wire system) and accordingly shifting & connecting service cables to another phase conductor in accordance with balancing of Electric load. submit feeder wise report for before load balancing and after load balancing as per format given including maintenance of LT panel i.e. tinting of all nuts, bolts, washers, cleaning of LT panel dust etc complete all as specified and directed by Engr-in-Charge.
Preparation of old painted surfaces of LT PCC poles for cross arms, MS strap, nuts, bolts, washers, cable protection pipe wherever provided etc and painting with one coat of aluminum paint and painting of bottom area of pole upto 2.1 m from ground level with synthetic enamel paint in alternate layer (30 cm wide) with black and yellow paint including writing pole numbers in white letter of approved size on black ground complete all as specified and directed.
Supply & Fixing in replacement of PVC four way separator for existing over head ACSR conductor complete all as specified and directed.
Supply & Fixing in repairs integral LED light fitting 45 watts comprising pressure die cast housing with power coated aluminum housing working as a heat shrink and toughened glass suitable for 32 mm OD pipe bracket IP-65 protection complete all as specified and directed.
S & F in repair PVC insulated twin core copper conductor cable of size 2.5 sqmm for connection of street light fittings.
S & F in repairs "ON LOAD" Change over switch suitable for three phase, 415 V, 50 Hz AC supply of 400 Amps 4P complete all as specified and directed.
S & F in repairs "ON LOAD" Change over switch suitable for three phase, 415 V, 50 Hz AC supply of 250 Amps 4P complete all as specified and directed.
S & F in repairs "ON LOAD" Change over switch suitable for three phase, 415 V, 50 Hz AC supply of 200 Amps 4P complete all as specified and directed.
S & F in repairs "ON LOAD" Change over switch suitable for three phase, 415 V, 50 Hz AC supply of 125/100 Amps 4P complete all as specified and directed.
NOTE :-(i)contractor should provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge.
Rajindera Enterprises
MV Engineers And Contractors
INDIAN CONSTRUCTION CO.
mayur enterprises
M/s JAIMAA ASSOCIATES
Vijay Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .