E.E.(E)/Z-V/GRU
LIGHTING department THE Kolkata Municipal Corporation E/3, Circular Garden Reach Road, Kolkata-700 024 West Bengal
RENOVATION OF STREET LIGHTING SYSTEM AT DIFFERENT LANES AND BYE LANES OF KHALDHARI MALI BAGAN, BIDHAN MAATH AND ADJACENT AREAS IN WARD NO. 140, UNDER BR-XV.
2026_KMC_988052_1
KMC/LTG/RS/73/25-26/188
Open Tender
Electrical Work/ Equipment
12 days
WARD 140
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹10,000
15 Mar 2026
17 Jan 2026
27 Jan 2026
17 Jan 2026
27 Jan 2026
17 Jan 2026
SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 14. Dismantling steel tubular/Rail/Strut embedded in CC foundation incl. excavation, filling of holes, restoring surface,loading at site and delivering, unloading, sorting, stacking properly at any place as per direction upto a lead of 1.6 km
Supplying Al.conductor PVC insulated and sheathed unarmoredcable (1.1KVgrade, Gloster/Havells/Polycab). 10sqmm x 2core
Supply and drawing of 7/14 SWG galvanised stranded wire for drawing unarmored cable (supply of cable is not included in the scope) by catenary system of wiring with 3nos. reel insulator per mtr. and binding with binding wires etc,as reqd. for drawing
Drawing of unarmoured cable of suitable size (supply of cable is not included in the scope)on existing Galvanized stranded wire for centenary system with reel insulators and binding wires.
CHAPTER - II LAYING & JOINTING PIPES, SPECIALS ETC.2.1 C.I. / D.I. Pipe & Specials 2.1 C.I. / D.I. Pipe & Specials 2.3 M.S. Pipes 2.3.1 Gas cutting of M.S. pipes and/or M.S. plates of different thickness all complete as per specification and direction of the Engineer-in- Charge. Thikness in mm 5mm to 8mm thick plate
CHAPTER - II LAYING & JOINTING PIPES, SPECIALS ETC.2.1 C.I. / D.I. Pipe & Specials 2.1 C.I. / D.I. Pipe & Specials 2.3 M.S. Pipes 2.3.1 Gas cutting of M.S. pipes and/or M.S. plates of different thickness all complete as per specification and direction of the Engineer-in- Charge. Thikness in mm 5mm to 8mm thick plate
BUILDING WORKS (F) STRUCTURAL STEEL WORKS, GRILLS, GATES ETC. B. REPAIRING 2. Welding in M.S. structural work with gas or electric: (b) Continuous weld.
SCHEDULE OF RATES FOR OVERHEAD LINE INSTALLATION - REPAIR 13. Providing CC (6:3:1) muffing 450x450x600 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable muffing if any incl. fixing only loop box if necessary (a) Without Loop Box
SCHEDULE OF RATES FOR EARTHING INSTALLATIONS.Earthing Installation ... with Pipe Electrode.Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (HOT Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(a)By ISI Medium GI pipe.
Removing of luminaries with lamp from the pole/column and keeping them ready for dispatch as per direction of EIC: HPMV/HPSV luminaries/MH/LED street light fittings.
Hoisting fixing and commissioning of luminaries including making necessary connection and earthing attachment: HPMV/HPSV luminaries/LED fittings of any wattage.
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of(approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. FOR receiving fresh coat of paint.Upto 9.0 mtr. long pole.(i)1st coat of aluminium paint over 1 coat of RO priming
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of(approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. FOR receiving fresh coat of paint.Upto 9.0 mtr. long pole.ii2nd coat of aluminium paint over 1st coat
Outdoor Lighting Installation, Steel Tubular Pole, M.S. Pipe, G.I. Pipe, Pole CAP etc Supplying of Swaged Steel Tubular pole as per IS 2713, Pt. II, 1980 for following designation and of following dimensions.(Outside dia & thickness are given in Annexture -1)e) 410 SP - 9 ; 7.5 Mtr., 110.00 Kg.
SCHEDULE OF RATES FOR OH LINE INSTALLATION (LT DISTRIBUTION).Erection of Poles.Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work(site including filling up the excavated earth pit with shifted soil and ramming properlyUpto 9.0 mtr. Size 0.6x0.6x1.70 mts
A N N E X U R E - I Basic Rate of Materials: (All Rates of materials from K-1 to K-14 are excluding VAT) 145. Galv. Straining screw 12"x5/8" dia
Erection of Galv. (HOT Dip) Cross arms/ `D... Iron Clamp7).Supplying & Erection of Galv. `D... iron complete with suitable pole clamp 75mmx88mm porcelain shackle insulator & 15 mm dia Galv. bolts & nuts. incl. painting
Painting Block Letters or Digits within a circle/square as required, with ...Black Japan... paint of(approved make & brand, the size of letters and digits as given below.Size 40 mm and upto 50 mm
Supplying Al.conductor PVC insulated and sheathed unarmoredcable (1.1KVgrade,Gloster/Havells/Polycab). 4sqmm x 2core
Laying through RCC/Hume/GI Pipe.(a)Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench FOR single, 2, 3, 3... & 4 core
SUPPLY & DELIVERY APPROVED MATERIALS_STREET LIGHT FITTINGS/LUMINAIRES 200 WATT LED FITTINGS_(BIS APPROVED)_AS PER KMC CENTRAL STORE PURCHASED RATE. (WITH O5 YEARS ONSITE WARRANTY WITHOUT ANY COST)
SUPPLY & DELIVERY APPROVED MATERIALS_STREET LIGHT FITTINGS/LUMINAIRES 100 WATT LED FITTINGS_(BIS APPROVED)_AS PER KMC CENTRAL STORE PURCHASED RATE. (WITH O5 YEARS ONSITE WARRANTY WITHOUT ANY COST)
S/F of special head type M S loop box (3 mm thick) with connecting bar and other accessories fixed on the top the pole as required and as per direction of Engineer-In-Charge. For 3 phase connection.
Sub Total
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.34 MB
BOQ_2413640.xls
BOQ • 0.36 MB
FORM.pdf
Tender Documents • 0.64 MB
Download all tender documents and submit your bid