Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 LAccepted-AOC 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | ₹10.3 L Quoted ₹11.2 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹12.5 LRejected-Finance | ₹12.5 L | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹12.9 LRejected-Finance | ₹12.9 L | L3 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | DEO Traders L1 | YS CONSTRUCTION L3 | M/S PASHUPATI TRADERS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, for laying of pipe line not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth and getting out in soft/ loose soil complete all as specified and as directed. | 130 | Cum | 100 ₹13,000 | 95 ₹12,350 | 120 ₹15,600 |
| 2.00 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/ loose soil complete all as specified and directed. | 117 | Cum | 50 ₹5,850 | 10 ₹1,170 | 80 ₹9,360 |
| 3.00 | Removing excavated material in soft/ loose soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. | 13 | Cum | 50 ₹650 | 10 ₹130 | 100 ₹1,300 |
| 4.00 | M&L for cutting of PCC/Hard standing/WBM road not exceeding 30 cm in depth not exceeding 60 cm in width for passing of GI/CI pipes all as specified and directed .Note : Making good with PCC shall be measured and paid separetely under respective item. | 18 | RM | 200 ₹3,600 | 100 ₹1,800 | 500 ₹9,000 |
| 5.00 | M&L for cement concrete(1:2:4) type B-0 using 12.50 mm graded granite stone aggregate for repairing to disturded surfaces complete all as directed. | 0.5 | Per Cum | 1,000 ₹500 | 2,500 ₹1,250 | 5,000 ₹2,500 |
| 6.00 | Taking up/ down of following bores of steel tubing and connections from excavated trenches and building up to tripple storey with due care from site complete all as specified and directed :- (a) 15 mm nominal bore | 200 | RM | 5 ₹1,000 | 5 ₹1,000 | 5 ₹1,000 |
| 7.00 | All as per Serial item No 6.00 above but 20 mm nominal bore | 270 | RM | 5 ₹1,350 | 5 ₹1,350 | 5 ₹1,350 |
| 8.00 | All as per Serial item No 6.00 above but 25 mm nominal bore | 260 | RM | 10 ₹2,600 | 5 ₹1,300 | 10 ₹2,600 |
| 9.00 | All as per Serial item No 6.00 above but 40 mm nominal bore | 230 | RM | 10 ₹2,300 | 5 ₹1,150 | 10 ₹2,300 |
| 10.00 | All as per Serial item No 6.00 above but 50 mm nominal bore | 240 | RM | 20 ₹4,800 | 10 ₹2,400 | 10 ₹2,400 |
Updated dates
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
6 Dec 2025, 6:00 pmClosed
Offg GE I R AND D KANPUR
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
REPAIR MAINT OF PUMP MOTOR CLEANING OF OVER HEAD TANK GI PIPE PVC TANK EXTERNAL WATER SUPPLY COMPLAINTS AND ALLIED WORKS IN DMSRDE AND WAR MEMORIAL UNDER GE I R AND D KANPUR
2025_MES_738055_1
8457/E/8
Open Tender
Electrical and Maintenance Works
270 days
KANPUR
As per Appx A of NIT
8 documents required · 8 mandatory
₹500
GE I R and D Kanpur
₹28,000
Yes
14 Feb 2026
1 Nov 2025
8 Dec 2025
1 Nov 2025
6 Dec 2025
16 Nov 2025
1 Nov 2025 - 15 Nov 2025
Amount
Excavation in trenches, for laying of pipe line not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/ loose soil complete all as specified and directed.
Removing excavated material in soft/ loose soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 30 cm in depth not exceeding 60 cm in width for passing of GI/CI pipes all as specified and directed .Note : Making good with PCC shall be measured and paid separetely under respective item.
M&L for cement concrete(1:2:4) type B-0 using 12.50 mm graded granite stone aggregate for repairing to disturded surfaces complete all as directed.
Taking up/ down of following bores of steel tubing and connections from excavated trenches and building up to tripple storey with due care from site complete all as specified and directed :- (a) 15 mm nominal bore
All as per Serial item No 6.00 above but 20 mm nominal bore
All as per Serial item No 6.00 above but 25 mm nominal bore
All as per Serial item No 6.00 above but 40 mm nominal bore
All as per Serial item No 6.00 above but 50 mm nominal bore
Supply & Fixing for replacement of following bore of GI tube medium grade/ ISI marked complete with all fittings (such as bends, elow, tees, connectors, caps, plugs, unions etc) including cutting, screwing as required and fixed to wall or roof or laid on floor or in trenches including fixing wall hooks, cutting through wall, floors etc and making good the disturbed surface with cement mrtar 1:3 after fixing the tubes complete all as specified and directed :- (a) 15 mm nominal bore
All as per Serial item No 11.00 above but 20 mm nominal bore
All as per Serial item No 11.00 above but 25 mm nominal bore
All as per Serial item No 11.00 above but 40 mm nominal bore
All as per Serial item No 11.00 above but 50 mm nominal bore
Re-laying, jointing and testing old but serviceable GI tubing of following bore (obtained from srl item No-6) and connection in new or old portion incl new fittings such as bends, elbows, union, tees, reducers etc as required at site laid in trenches or on floor or wall complete and making good all disturbed surfaces of wall/ floor/ road/ path to match with existing specification all as specified and as directed :- (a) 15 mm nominal bore
All as per Serial item No 16.00 above but 20 mm nominal bore
All as per Serial item No 16.00 above but 25 mm nominal bore
All as per Serial item No 16.00 above but 40 mm nominal bore
All as per Serial item No 16.00 above but 50 mm nominal bore
Disconnecting, dismaantling and taking down CI/GI/DI/Cemented pipe line of size 100mm bore, including all fittings with spigot and socket/ flanged end or any type, lead joint including removing from site complete all as specified and directed.
All as per Serial item No 21.00 above but of size 150mm.
All as per Serial item No 21.00 above but of size 200mm.
M&L in replacement of ductile iron pies 100mm bore incl rubber gasket joints and other relative accessories, class K-7 in any length laid in trenches complete all as specified and directed.
All as per Serial item No 24.00 above but of size 150 mm.
All as per Serial item No 24.00 above but of size 200 mm.
S&F in replacement of cast iron double flanged sluice valve of size 80mm bore class PN 1.0 confirming to IS 14846/2000 with with high tensile stainless steel spindle with CI wheel, Gun Metal Nuts/rings 'I' bolt, ISI marked including replacement of rubber packing complete all as specified and directed.
All as per Serial item No 27.00 above but sluice valve of size 100mm.
All as per Serial item No 27.00 above but sluice valve of size 150mm.
All as per Serial item No 27.00 above but sluice valve of size 200mm.
S&F in replacement of cast iron double flanged sluice valve of 150mm dia class PN 1.6 confirming to IS 14846/2000 with with high tensile stainless steel spindle with CI wheel, Gun Metal Nuts/rings 'I' bolt, ISI marked including replacement of rubber packing complete all as specified and directed.
Material & Labour to repair leakages through lead joints from existing CI/DI pipe, fittings, tee, bends tail pieces, connecting pieces etc by using previously used and additional run lead , spun yarn including caulking to make the joints water tight including excavation works as required complete all as specified and directed for the following bore pipe line but of size 80/100 mm.
All as per Serial item No 32.00 above but of size 150/200 mm.
M&L for Cast iron/ductile iron special fittings for spigot and socketed pipes such as bends (any type, radius and angle) socket tapers any type, (straight, bend, increasing, decreasing or double socket etc) Tee pieces, single branch, Y junction, double branch, cross (all sockets or socket and spigot) collers, caps and plugs for upto 150 mm bore pipes complete all as specified and directed.
S&F gun metal iron gate valve 20mm dia with iron wheel head, screwed both ends for iron pipe, ISI marked, complete all as specified including dismantling the old unserviceable existing valve complete all as specified and directed.
All as per Serial item No 35.00 above but of size 25 mm bore.
All as per Serial item No 35.00 above but of size 40 mm bore.
All as per Serial item No 35.00 above but of size 50 mm bore.
S&F in replacement of Dosing tank only capacity 100 Ltrs MOC PE FRP Ltd contaning port hole for pouring chlorination chemical and water them necessary provision for mounting of moteo at proper angel provision for mounting dosing pump on lid level gauge.
M&L for opening up of leaking sluice valve 80 to 150mm and repacking of stuffing box, steel spindle with check nut & replacement of gland packing, nuts, bolts & washers, rubber gaskets etc complete all as specified.
Cutting and removing unwanted grass and wild growth including bushes and shrubs from the roots at water supply installations including removing and even finish the entire area complete all as specified and directed at site by Engineer in charge.
Supply & Feeding/Dissolving calcium Hypo chlorite having 65% to 70% chlorine content Granular Chlorination Chemical (Water Treatment Chemical ), free flowing granular material free of foreign matter in 45 Kg in sealed packing complete all as specified and directed. Note : Feeding of calcium Hypo chlorite granules to dozer pump should be done on daily basis in limited amount as specified by Engg-in-charge.
Material and Labour for brick masonry valve pit chamber of size 1200mm x 1200mm x 1200 mm (internal) complete with PCC (1:3:6) type C-2 for foundation, brick work in Cement Mortar (1:6), 15 mm thick plastering in Cement Mortar (1:4) (internally) including 6.0 mm thick MS plate covering and angle iron frame of 40mm x 40mm x 6.0 mm including coping, 100 mm thick, PCC flooring in 1:2:4 type B-1 and two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces with locking arrangement complete all as specified and directed.
Material and Labour for brick masonry valve pit chamber of size 1000mm x 1000mm x 1000 mm (internal) complete with PCC (1:3:6) type C-2 for foundation, brick work in Cement Mortar (1:6), 15 mm thick plastering in Cement Mortar (1:4) (internally) including 6.0 mm thick MS plate covering and angle iron frame of 40mm x 40mm x 6.0 mm including coping, 100 mm thick, PCC flooring in 1:2:4 type B-1 and two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces with locking arrangement complete all as specified and directed.
Testing of drinking water for chemical analysis as per IS 10500:2012 guideline after lifting the sample from pump as per testing guide line enumarated in test physical parameter (pH value, turbudity, colour, order) Chemical parameter (Amonia free & saline, Ammonia Albuminoid o2 absorbed, nitrate, chloride, hardness temprory and permanent, TDS, Metal Iron, Magnese, Zinc, Calcium, Magnisium, Sulphate, Phenolic Sustances) all as directed by Engr In Charge. Make: Bhart Test House/HBTU/ Sepectro, BalaJee Labs
Supply and replacement of Bib tap 15 mm size ISI marked standard of PTMT any colour high pressure screwed for iron pipes and fixed.
Attending of day to day complaints of external water supply of any floor and all nature i.e. leakage in water pipe lines, fittings /fixture, no water supply including all type of complaint noted in complaint register all complaints slips received from the complaint cell and deposit the complaint slip after reactification and obtained signature of users with necessary T&P with experianced trade man with GI fittings i.e. elbow, tee, reducer, union, long screw socket, nipple, plug etc complete all as directed . Note : The complaint shall be attended and defect shall be rectified with in 24 hrs commencing from the date and time of notifying the complaint failing which a penalty @ Rs 100 per complaint per day shall be recovered from BIll.
M&L for quarterly cleaning after disconnecting and stopping of incoming and outgoing pipes of RCC over head tank of capacity 1,00,000 gallon by means of hassen clothe to avoid choking of distribution pipe lines,removing total water ,frame the over head tank,cleaning tank complete with steel brush, removing complete settled dirt /sand/silt and flushing the complete tank through wash out pipes,cleaning of pipes(Rising, delivery wash out ,over flow pipes),Sluice valve of any size including painting after cleaning surface of pipes with existing shade of synthetic enamel paint and date of cleaning shall also be mentioned on over head tank of pillar with synthetic enamel paint, including removing bee hives from OH Tank if present as directed by Engr-in-Charge at site complete all as specified and directed Note:- (a) The work shall be carried out through trained staff with hygiene and safety equipment. (b) Responsibility for insurance and safety of team will solely rest with the contractor.
M&L for quarterly cleaning after disconnecting and stopping of incoming and outgoing pipes of RCC over head tank of capacity 50,000 gallon by means of hassen clothe to avoid choking of distribution pipe lines,removing total water ,frame the over head tank,cleaning tank complete with steel brush, removing complete settled dirt /sand/silt and flushing the complete tank through wash out pipes, cleaning of pipes (Rising, delivery wash out, over flow pipes),Sluice valve of any size including painting after cleaning surface of pipes with existing shade of synthetic enamel paint and date of cleaning shall also be mentioned on over head tank of pillar with synthetic enamel paint, including removing bee hives from OH Tank if present as directed by Engr-in-Charge at site complete all as specified and directed Note:- (a) The work shall be carried out through trained staff with hygiene and safety equipment. (b) Responsibility for insurance and safety of team will solely rest with the contractor.
S&F in replacement Digital AC Volt meter ( 0 to 500/600 Volt), square size, flush mounted case, complete all as specified and directed.
S&F in replacement Digital AC Ammeter ( 0 to 200 Amp ), CT Operated-5 Amps, square type, flush mounted case,complete all as specified and directed .
S&F in replacement single phase preventer VSP3 auto reset 50 volts unbalanced type for 30to 50 HP submersible pump set completet all as specified.
S&F in replacement of fully automatic star delta starter, suitable for 30to 50 HP submersible motor, 3 phase 440 volt complete with over load protection with adjustable relay range, electronic timer relay and single phasing preventor incl suitable size 40X4 mm angle iron frame grouted on wall for proper mounting arrangement all as specified.
S&F of in repair Power contactor TP as per existing type & make fitted at site for starter suitable for 40 HP/30HP/20 HP submersible pump set. Make- L&T/Legrand/Siemens
S&F in repair Over load relay (as per sample) for starter suitable for 40 HP/30HP/20HP submersible pump set. Make- L&T/Legrand/Siemens
S&F in repair Timer (as per sample) suitable for star delta starter for 40/30/25/20 HP submersible pump set. Make- L&T/Legrand/Siemens
M&L for replacement of MS angle iron/Channel support for motor/pump incl nut bolt etc incl painting and making good all disturbed surfaces with PCC 1:2:4 complete all as spfd and directed.
M&L for repairing the leakage of flange end joints for MS/CI pipe by doing welding incl replacement of rubber gasket, nut, bolt and washers etc bailing out pipe line water as required and directed for the sizes upto 150mm bore.
Taking / lifting out defective submersible pumps set from bore well complete with column pipe upto 25mm dia steel rope, submersible cable and accessories etc and relowering and commissioning the same after repairing works including rubber gasket and testing complete of rating 1.5 to 2 HP 3 phase.
Dismantling, taking out complete burnt winding wire of submersible motor including cleaning of stator slots replacement of defective parts and rewinding with existing type & gauge of copper winding wire pvc insulated as per motor capacity and using new insulation material such as insulating paper sleeves etc.replacement of submersible cable as required size/ length complete incl testing all as directed of rating 1.5 HP to 2 HP 3 phase. Noe : The cost of transportation from pump house/yard to workshop and workshop to pump house/yard shall deemed to be included in item rate quoted by contractor.
Dismantling submersible pump, straightening & polishing of pump shaft, making threading and key way, turning surfacing polishing to impellers, CI bowl complete including ss implellers,NRV,Thrust bearing,Neck ring,Dsitance sleeve, High tensile nut bolts, coupling key ,Sand guard replacement of worn out parts as per requirement complete incl testing and all as directed of rating 1.5 to 2 HP 3 Phase. Noe : The cost of transportation from pump house/yard to workshop and workshop to pump house/yard shall deemed to be included in item rate quoted by contractor.
Taking / lifting out defective submersible pumps set from bore well complete with column pipe upto 150mm dia steel rope, submersible cable and accessories etc and relowering and commissioning the same after repairing works including rubber gasket and testing complete of rating 30 to 40 HP 3 phase.
Dismantling, taking out complete burnt winding wire of submersible motor including cleaning of stator slots replacement of defective parts GM motor bus, Rotor bearing, and rewinding with existing type & gauge of copper winding wire pvc insulated as per motor capacity and using new insulation material such as insulating paper sleeves etc.replacement of submersible cable as required size/ length complete incl testing all as directed of rating 20 to 30 HP 3 phase. Noe : The cost of transportation from pump house/yard to workshop and workshop to pump house/yard shall deemed to be included in item rate quoted by contractor.
Dismantling submersible pump, straightening & polishing of pump shaft, making threading and key way, turning surfacing polishing to impellers, CI bowl complete including replacement of worn out parts of SS impellers with Key and distance bushes, Trust Bearing, Distance sleeves, Neck ring High tensile nut bolts , coupling key, Housing ,sand guard as per requirement complete incl testing and all as directed of rating 20 to 30 HP 3 Phase. Noe : The cost of transportation from pump house/yard to workshop and workshop to pump house/yard shall deemed to be included in item rate quoted by contractor.
Supply only steel wire rope stranded 12 mm dia for hanging of submersible pump set .
Supply only electric cable for submersible pump set, flat 6 Sqmm 3 core stranded copper conductor PVC sheathed cable all as specified and directed. Make- Finolex/ Paragon/Havells
Supply only electric cable for submersible pump set, flat 10 Sqmm 3 core stranded copper conductor PVC sheathed cable all as specified and directed. Make- Finolex/ Paragon/Havells
Supply only electric cable for submersible pump set, flat 16 Sqmm 3 core stranded copper conductor PVC sheathed cable all as specified and directed. Make- Finolex/ Paragon/Havells
Supply only MS column pipe heavy Duty of size 150 mm nominal dia in standard length of 3.0 mtr, heavy duty duly threaded welded with MS Flange of 12 mm thick on both end with supporting ribs (4 Nos.) including jointing & with new rubber or fiber board gasket with all nuts, bolts and washer set complete all as specified and directed of Make : Jindal/TATA.
S&F Rotationl moulded polyethylene water storage tank 500 liters capacity, white triple layer construction (cylindrical vertical closed top), hoisted & fixed in position including all fittings i.e. GI tank nipple, PVC Float valve 20mm etc complete all as specified and as directed.
S&F Rotationl moulded polyethylene water storage tank 1000 liters capacity, white triple layer construction (cylindrical vertical closed top), hoisted & fixed in position including all fittings i.e. GI tank nipple, PVC Float valve 20mm etc complete all as specified and as directed.
M/S PASHUPATI TRADERS (BID ID -3491330)
YS CONSTRUCTION (BID ID -3490757)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
BOQ_826425.xls
BOQ • 0.35 MB
Tender8457.pdf
Tender Documents • 0.81 MB
Download all tender documents and submit your bid