Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.3 LAccepted-AOC | ₹7.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹7.7 L+₹40,718 (5.57%)Rejected-Finance | ₹7.7 L+₹40,718 (5.57%) | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | SREE SAI KRISHNA ENTERPRISES L1 | POORVIKA CONSTRUCTION L2 |
|---|---|---|---|---|---|
| 1.00 | Geophysical Investigation charges including preparation of geophysical report as per TWAD Board type circular including all cost of transportation and handling charges etc.,complete | 2 | No | 3,500 ₹7,000 Lowest | 3,720 ₹7,440 |
| 2.00 | Supply and delivery of 150mm (CS) 6KSC pvc casing pipe for bore well including cost ang convayance of material and labour charge etc complete. | 36 | Rm | 450 ₹16,200 | 424 ₹15,264 Lowest |
| 3.00Drilling of 150mm(6") dia Vertical clear bores in Hard rock in any habitation any where in Salem District to any required depth as directed b y the officers concerened including labour charges for inserting M.S/P.V.C Casing pipes to any reauired depth , assembilling in the drilled hole including welding joints if necessary . Grouting the cassing pipes including conducting proper yield test at final depath (by provinding 90 ' V' Notch fitted in a formed channel and the correct yield at the time of free flow in the channel while flushing the bore after completion of drilling process should be ascertained of and reported )including Bore cover transportation. crew and fuel charges for rigs and supporting Vechicles from one place to another etc Complete and as directed by officers Concerned. | |||||
| 3.01 | upto 150m Below Ground Level | 300 | Rm | 290 ₹87,000 Lowest | 305 ₹91,500 |
| 3.02 | from 151m upto 180m | 60 | Rm | 300 ₹18,000 Lowest | 335 ₹20,100 |
| 3.03 | From 181 to 210m | 40 | Rm | 350 ₹14,000 Lowest | 390 ₹15,600 |
| 4.00 | Supply and delivery of clear water vertical wet type submersible pumpset suitable for 50mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 % | 2 | No | 60,000 ₹1,20,000 Lowest | 74,374.5 ₹1,48,749 |
| 5.00 | Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). | 2 | No | 18,000 ₹36,000 Lowest | 18,398 ₹36,796 |
| 6.00 | Supply and delivery of 4.00sqmm flat type PVC insulated 3core copper cable confirming to IS694/1990 with ISI Marking suitable for submersible pump set etc complete. | 380 | Rm | 200 ₹76,000 | 192.2 ₹73,036 Lowest |
| 7.00Supply and delivery of following pipeline materials from approved company including all cost and conveyance etc.,complete | |||||
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
14 Aug 2026, 3:00 pmClosed
Executive officer Belur Town Panchayat
Executive officer Belur Town Panchayat
Providing New Borewell and Extension of Pipeline at Ward No. 2 Near Malligai Mahal and Ward No. 6 Near Thumbal Road in Belur Town Panchayat
2026_DTP_691993_1
176/2026
Open Tender
Civil Works
Works
Belur
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹20,000
Yes
31 Aug 2026
7 Aug 2026
14 Aug 2026
7 Aug 2026
14 Aug 2026
7 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Geophysical Investigation charges including preparation of geophysical report as per TWAD Board type circular including all cost of transportation and handling charges etc.,complete | 2 | No | 4,000 | ₹8,000 |
| 2 | Supply and delivery of 150mm (CS) 6KSC pvc casing pipe for bore well including cost ang convayance of material and labour charge etc complete. | 36 | Rm | 457 | ₹16,452 |
| 3Drilling of 150mm(6") dia Vertical clear bores in Hard rock in any habitation any where in Salem District to any required depth as directed b y the officers concerened including labour charges for inserting M.S/P.V.C Casing pipes to any reauired depth , assembilling in the drilled hole including welding joints if necessary . Grouting the cassing pipes including conducting proper yield test at final depath (by provinding 90 ' V' Notch fitted in a formed channel and the correct yield at the time of free flow in the channel while flushing the bore after completion of drilling process should be ascertained of and reported )including Bore cover transportation. crew and fuel charges for rigs and supporting Vechicles from one place to another etc Complete and as directed by officers Concerned. | |||||
| 3.01 | upto 150m Below Ground Level | 300 | Rm | 330 | ₹99,000 |
| 3.02 | from 151m upto 180m | 60 | Rm | 360 | ₹21,600 |
| 3.03 | From 181 to 210m | 40 | Rm | 420 | ₹16,800 |
| 4 | Supply and delivery of clear water vertical wet type submersible pumpset suitable for 50mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 % | 2 | No | 79,973 | ₹1,59,946 |
| 5 | Supply and delivery of Star-Delta starter confirming to IS 13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/ Three Phase/50HZ (+/- 5%) and 415V (+/- 10%) including 3 pole magnetic contactor with under voltage release - 3 nos., CT operated Ammeter (65 mm dia) with suppressed scale, Voltmeter (65mm dia), Voltmeter selector switch, Miniature circuit breaker, Thermal Overload relay, Air Break contactors suitable for next Standard higher KW rating, Single phasing preventor, dry running preventor and On/Off Push button switches, wiring with 1 sq.mm/4 sq. mm copper pvc insulated cable, powder coated vermin proof box, including the capacitor (the cost of capacitor is to be taken separately). | 2 | No | 19,784 | ₹39,568 |
| 6 | Supply and delivery of 4.00sqmm flat type PVC insulated 3core copper cable confirming to IS694/1990 with ISI Marking suitable for submersible pump set etc complete. | 380 | Rm | 206 | ₹78,280 |
| 7Supply and delivery of following pipeline materials from approved company including all cost and conveyance etc.,complete | |||||
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.23 MB
Bid.pdf
Tender Documents • 0.76 MB
BOQ_832042.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .