Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 LAccepted-AOC 0 AJAY KUMAR 85 HASTAM HASTAM BANDA UTTAR PRADESH 210001 HASTAM BANDA UTTAR PRADESH 210001 UDYAM UP 13 0007628 | BANDA | UTTAR PRADESH | 210001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹6.8 L+₹1.3 L (23.7%)Rejected-AOC DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC L2 |
Tender Value
Refer Docs
EMD Value
₹15,000
Closing Date
26 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Prashant Kumar Gaur
AGE (i) Raiwala
PROVN OF CERTAIN SANCTION WORK FOR E M SERVICES AT MILY STN RAIWALA
2020_MES_381778_1
8835/E8
Open Tender
Civil Works
Item Rate
180 days
Raiwala
as per tender documents
8 documents required · 8 mandatory
₹500
Yes
AGE (I) Raiwala
₹15,000
Yes
27 Nov 2020
1 Oct 2020
28 Oct 2020
1 Oct 2020
26 Oct 2020
9 Oct 2020
60 days
Amount
M & L for point wiring with PVC unsheathed, fire resistance, low smoke, stranded copper conductor of size 2.5 sqmm (nominal cross sectional area ) single core cable in and including concealed (surface only on roof & colomns) wiring incl PVC conduit medium grade, ISI marked, 20 mm or higher dia complete with all accessories/fittings and sunkan MS boxes of thickness not less than 1.2 mm covered with 3 mm thick plastic laminated hard glassy surface sheet cover concealed in wall with brass screws & washers including unsheathed single core PVC insulated cable green in colour 1.5 sqmm stranded copper conductor as earth wire and connecting to earth dolly,and making good all disturbed work to match the existing. complete all as specified & directed for the one light /fan /bell /exhaust fan point controlled by one way 5/6 switch.
S&F switch piano flush type white /ivory finish 5/6 Amps, single pole one way complete all as specified & directed.
Supply and fixing 100W flood light Rectangular LED Flood Light with innovative thermal management and available in multiple optics and equipped, with environment friendly and robust open type verticle Highbay LED IP 66 luminaire with heigh power COB LED as light source inlcuding all fixing arrangements and connecting service cable from ceiling rose to light complete all as specefied and as directed.
S& F double door sheet metail enclosure for DB , 04 way , SPN, with 200 Amps bus bar , 240 Volts suitable for housing MCBs and isolator and making good for disturbed surface with existing etc complete all as specified & directed.
S&F MCB, single pole 240 Volts 5 to 30 Amps complete all as specified & directed.
S&F Isolator single pole and neutral 240 Volts 40 Amps complete all as specified & directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core all as specified and directed.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter depth and getting out soft / loose soil complete all as specified and directed by Engr-in-Charge.
M&L for filling dry river sand, spread &compacting for sand cushioning of Under ground cable all as specified complete all as specified and directed by Engr-in-Charge.
Supply and laying burnt brick sub class 'b' 22 X 10 X 7.5 cm locally available laid length of brick perpendicular to the length of cable complete all as specified and directed by Engr-in-Charge.
Returning and filling of soil including spreading leveling, watering and ramming in layers not exceeding 25 cm complete all as specified and directed by Engr-in-Charge.
Removing excavated soil to a distance not exceeding 50 meter , not exceeding 1.5 meter above the starting point and depositing where directed complete all as specified and directed by Engr-in-Charge.
S&Laying GI tubing 40 mm dia Light grade with all fittings in trenches or road crossing for protection of LT under ground cables complete all as specified and directed by Engnr-in-Charge.
Supply & fix ceiling fans complete with elctronic type regulatorand accessories 230 volt,1200 mm sweep complete all as specified & directed by Engineer-in- Charge
M & L for point wiring with PVC unsheathed, fire resistance, stranded copper conductor of size 1.5 sqmm (nominal cross sectional area ) single core cable in and including concealed (surface only on roof & colomns) wiring incl PVC conduit medium grade, ISI marked, 20 mm or higher dia complete with all accessories/fittings and sunkan MS boxes of thickness not less than 1.2 mm covered with 3 mm thick plastic laminated hard glassy surface sheet cover concealed in wall with brass screws & washers including unsheathed single core PVC insulated cable green in colour 1.5 sqmm stranded copper conductor as earth wire and connecting to earth dolly, complete all as specified & directed for One light /fan /bell /exhaust fan point controlled by one , one way 5/6 switch.
M & L for sub main wiring with two run of 4 Sqmm (nominal cross sectional area ) of single core unsheathed PVC insulated cables 1100 Volts grade multi stranded copper conductor drawn through & including non metallic rigid PVC conduit of size 19/20 mm or higher dia with & including necessary conduit accessories concealed/surface only on roof & colomn) type including 2.5 Sqmm stranded copper conductor PVC insulated cable as earth wire connected to common earth dolly complete all as specified & directed by Engineer-In-charge.
M& L for earthling complete with galvanized steel earth plate, electrode 600 x 600x6 mm thick , buried directly under ground (earth pit not less than 2.25 m below ground level ) with top edge of the plate not less than 1.5 below ground level connected to galvanized earth wire 4.0 mm dia by means of nuts, bolts, check nuts & washers, of galvanized iron or steel all as Shown in electrical plate No 5 connected to main switch board, including all necessary excavation & earth work in hard/dense soil, common salf and charcoal dust mixed & packed 150 mm thick homogeneous layer all around the GI earth plate, earth pit chamber made out of cast iron frame with hinged door , GI protection pipe light grade upto 7.5 meter from electrode complete all as specified & shown on drawings with watering pipe .Note :- (1) Earth lead and GI pipe light grade 15 mm dia for protection against mechanical damage beyond 7.5 mtr from electrode to earth terminal point/main switch board. Etc shall be measured separately .(2) On testing, after completion of Job , if desired earth resistance is not obtained , the earthing shall be redone at no extra cost to contractor.
S &F socket out let 2 pin 5/6 Amps & 3 pin 5/6 Amps flush type - ditto-.
Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 6000 CuM per hour (or nearest size).(*Steel body) including internal and external body paint to avoid from rusting.Make :- USHA/Bajaj/Crompton/Kaitan .
M & L for brik work including excavation plastring and finishes as cooler stand all as specefied and as directed by .
Supply and fixing flood light 150watt LED IP 66 luminaire with heigh power LED as light source inlcuding all fixing arrangements and connecting service cable from pole box to light complete all as specefied and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core all as specified and directed.
Supply and fix 1.5 ton invertor split type air condioner 5 star rating with air circulation 850 cfm and copper condensor coil all as specified and as directed by engr -in charge Of Make :- Voltas/LG/Daikin/Carrier.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.00 KVA WITH TDR of Make :- Luminious/V guard/microtek etc
Supplied & fixed Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240 volt 20 Amps complete all as specefied and as directed by engr in chage.
Supply and fix Water heater storage type, electric,capacity 25 litres.BEE 5 star rated complete all as specified & directed by Engineer In-charge.Make Bajaj Shakti GPV SWH ABS body or equivalent in crompton/Havells/Usha.
S & F necessary connecting items for making geyser water supply connection from the exisiting 15 mm GI pipeline including hot water PVC connection(02 No.), necessary 15 mm GI pipe medium grade from exisiting water supply to geyser and two nos of 15 mm Stop cocks and one no of cromimum plated tap with inculding all fittings and fixtures to install geyser on cemented / brick wall .
TARUN ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .