| Sl No | Description | Qty | Unit | Swarnendu Sarkar L2 | M/S S. CHATTERJEE L1 | BABA ELECTRIC L3 |
|---|---|---|---|---|---|---|
| 1.00SITC of Microprocessor based Intelligent, addressable fire alarm control panel ( VDS / UL / FM / ULC /EN-54 approved ) fully networkable having requisite numbers of loops with 20% spare capacity with each loop capable of taking requisite number of devices as per latest IS/NBC, 1/4 VGA display character alpha-numeric liquid crystal display. The panel shall be soft addressable type.The panel shall be able to give pinpoint location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches whenever any alarm is triggered.The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. IS / NBC. Should have the provision for incorporating with BMS. | ||||||
| 1.01The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 30 minutes during Emargency condition, with integral battery charger complete as required. | ||||||
| 1.02 | The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 bus.The FACP shall have provision for interfacing with the public address system and BMS( RS 485 ). The panel should have modbus output & ready to communicate with remote computer. The system must be preloaded with licenced software. (Approved Make: Esser/ Notifer /Secutron / GST/ Mircom ). | 1 | Set | 3,61,000 ₹3.6 L | 3,60,000 ₹3.6 L | 3,61,500 ₹3.6 L |
| 2.00 | SITC of Analog Addressable Intelligent multisensor detector ( VDS / UL / FM / ULC /EN-54 approved ) with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard.(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended IS / NBC ) without any additional cost). (Approved Make: Esser/ Notifer /Secutron / GST/ Mircom ). | 120 | Nos | 3,850 ₹4.6 L | 3,850 ₹4.6 L | 3,850 ₹4.6 L |
| 3.00 | SITC of Addressable Heat Detector (Fixed temperature cum rate of rise) ( VDS / UL / FM / ULC /EN-54 approved ) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Approved Make: Esser/ Notifer /Secutron / GST/ Mircom ). | 6 | Nos | 3,750 ₹22,500 | 3,750 ₹22,500 | 3,750 ₹22,500 |
| 4.00 | SITC of Addressable Manual Call Point ( VDS / UL / FM / ULC /EN-54 approved ) soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Esser/ Notifer /Secutron / GST/ Mircom ). | 4 | Nos | 5,300 ₹21,200 | 5,300 ₹21,200 | 5,300 ₹21,200 |
| 5.00 | SITC of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL / FM / ULC /EN-54 approved ) (Approved Make: Esser/ Notifer /Secutron / GST/ Mircom ). | 4 | Nos | 6,200 ₹24,800 | 6,200 ₹24,800 | 6,200 ₹24,800 |
| 6.00 | SITC of Addressable Loop Isolator Module ( VDS / UL / FM / ULC /EN-54 approved ) for SLC line protection from loop line short circuit and any serge pass (Approved Make: Esser/ Notifer /Secutron / GST/ Mircom ). | 14 | Nos | 4,600 ₹64,400 | 4,600 ₹64,400 | 4,600 ₹64,400 |
| 7.00 | Supply and installation of Fire extinguishing Ball with Mounting Accessories. Make AFO/Fyrex/Cease Fire. | 2 | Nos | 3,800 ₹7,600 | 3,800 ₹7,600 | 3,800 ₹7,600 |
| 8.00 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/RR Kable/Polycab ) with 20 mm NB PVC rigid conduit pipe (Make: Precision /AKG/ATUL /VIP/ Universal /BEC/Polycab) on the surface of the wall. | 1,100 | Mtr | 143 ₹1.6 L | 143 ₹1.6 L | 143 ₹1.6 L |
Tender Value
Refer Docs
EMD Value
₹22,406
Closing Date
28 Dec 2024, 2:30 pmClosed
Superintending Engineer, SWEC, PWD
OFFICE OF THE SUPERINTENDING ENGINEER (P.W.Dte) South-Western Electrical Circle PWD Compound,Midnapore,Paschim Medinipur
Construction of a new ITI Building at Gangajalghati under Gangajalghati Block in the district of Bankura---SITC of Fire Detection and annunciation system.
2024_WBPWD_765013_1
WBPWD/SE/SWEC/NIQ54/2024-25
Open Tender
ELECTRICAL WORKS ORG
30 days
BANKURA
Please refer Tender documents.
3 documents required · 3 mandatory
₹22,406
O/O of SE, SWEC,PWD, PWD Compound, Midnapur
27 May 2026
12 Dec 2024
30 Dec 2024
12 Dec 2024
28 Dec 2024
16 Dec 2024
16 Dec 2024
Amount
SITC of Microprocessor based Intelligent, addressable fire alarm control panel ( VDS / UL / FM / ULC /EN-54 approved ) fully networkable having requisite numbers of loops with 20% spare capacity with each loop capable of taking requisite number of devices as per latest IS/NBC, 1/4 VGA display character alpha-numeric liquid crystal display. The panel shall be soft addressable type.The panel shall be able to give pinpoint location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches whenever any alarm is triggered.The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. IS / NBC. Should have the provision for incorporating with BMS.
The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 30 minutes during Emargency condition, with integral battery charger complete as required.
The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 bus.The FACP shall have provision for interfacing with the public address system and BMS( RS 485 ). The panel should have modbus output & ready to communicate with remote computer. The system must be preloaded with licenced software. (Approved Make: Esser/ Notifer /Secutron / GST/ Mircom ).
SITC of Analog Addressable Intelligent multisensor detector ( VDS / UL / FM / ULC /EN-54 approved ) with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard.(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended IS / NBC ) without any additional cost). (Approved Make: Esser/ Notifer /Secutron / GST/ Mircom ).
SITC of Addressable Heat Detector (Fixed temperature cum rate of rise) ( VDS / UL / FM / ULC /EN-54 approved ) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Approved Make: Esser/ Notifer /Secutron / GST/ Mircom ).
SITC of Addressable Manual Call Point ( VDS / UL / FM / ULC /EN-54 approved ) soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Esser/ Notifer /Secutron / GST/ Mircom ).
SITC of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL / FM / ULC /EN-54 approved ) (Approved Make: Esser/ Notifer /Secutron / GST/ Mircom ).
SITC of Addressable Loop Isolator Module ( VDS / UL / FM / ULC /EN-54 approved ) for SLC line protection from loop line short circuit and any serge pass (Approved Make: Esser/ Notifer /Secutron / GST/ Mircom ).
Supply and installation of Fire extinguishing Ball with Mounting Accessories. Make AFO/Fyrex/Cease Fire.
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/RR Kable/Polycab ) with 20 mm NB PVC rigid conduit pipe (Make: Precision /AKG/ATUL /VIP/ Universal /BEC/Polycab) on the surface of the wall.
TERMS & CONDITIONS a.The Fire Alarm system shall comply with latest requirements of -- 1. National Fire Protection Association (NFPA) Standards. 2. IS 2189 3. NFPA 70 National Electric Code 4. NFPA 72 National Fire Alarm Code 5. local Statutory Regulations 6. Manufacturer Recommendation.
b. TESTS:1.The system shall be tested and commissioned by a qualified competent,trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults, continuity, and insulation and other tests as per above standards must be done.
c. Auto CAD Drawing of whole FDA system & submission of 5 set hard copy of drawing and soft copy (in Auto-CAD format) is to be submitted.
d. The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
e. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
f. If any refurbished material is supplied and installed, penal action will be taken as per existing rules
Swarnendu Sarkar (BID ID -5892284)
BABA ELECTRIC (BID ID -5919017)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid