| 1 | 1₹2.9 LAccepted-Finance 10 BKGI GARDEN SEMMEDU GARDEN THIRUPUR | ERODE | TAMIL NADU | 638051 | 1 | Accepted-Finance Bidder Quoted Value is Less than the Estimate Amount | |
| 2 | 2₹3.0 L+₹5,949 (2.04%)Rejected-Finance NO 152 E V R NAGAR SRIRANGAM TIRUCHIRAPPALLI 5 | TIRUCHIRAPPALLI | TAMIL NADU | 620001 | 2 | Rejected-Finance Bidder Quoted Value is Greater than the Estimate Amount |
Tender Value
₹3 L
EMD Value
₹6,000
Closing Date
13 Aug 2024, 3:00 pmClosed
ASSISTANT COMMISSIONER
ASSISTANT COMMISSIONER ZONE 2
Erection of 7 5HP Submersible pump, Panel board UPVC pipes cable in Borewell at TNK Puram 3RD Street in Ward No 19
2024_MAWS_467990_35
E1/3100/2024/Z2
Open Tender
Civil Works - Water Works
Works
90 days
Tirupur City Municipal Corporation Zone 2
Please Refer Tender Document
3 documents required · 3 mandatory
₹0
₹6,000
20 Sept 2024
31 Jul 2024
13 Aug 2024
31 Jul 2024
13 Aug 2024
31 Jul 2024
Amount
Supply and delivery of the following size of UPVC pipes with ISI specification as directed by the departmental officers including cost and conveyence the same to the departmental store etc complete as per standard specification.
Supply and delivery of clear water vertical wet type submersible pumpset suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 %
Supply of 4 sqm submercible cabel with ISI make etc., complete as per standard specification. (IS 694/1990)
Labour Charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable withproper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days.
Supply and fixing of TNEB meter Board suitable for 32A Three Phase service connection with 3 Nos. 32A Fuse unit (500V) 32A neutral link and earth link (1" x 1/8" Copper flat) on TW plank of size 600mm x 450mm x 19mm with supporting TW reepers of 1" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit.
Supply of 63 Amps 30 MA RCCB/ELCB (FOUR POLE) etc., complete.
Supply and run of 4 of 4 Sq.mm (56/0.3) PVC insulated unsheathed Copper conductor cable of 1100 V grade on 7/20 GI bearer wire for service connection mains (SD 50)
Supply and run of 4 of 4 sq.mm (56/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in 25mm dia GI pipe (Class 'B') bent at both ends with necessary angle iron up right and end supports for mains (SD 72)
Add GST @ 18%
SVT Constructions (BID ID -1108214)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .