Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC | ₹40.4 L Quoted ₹41.1 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹41.6 L+₹55,154.50 (1.34%)Rejected-AOC | ₹41.6 L+₹55,154.50 (1.34%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹43.6 L+₹2.6 L (6.26%)Rejected-AOC VILL BUNGDAL DADHANI P O BADHANI DISTT PATHANKOT PIN 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹43.6 L+₹2.6 L (6.26%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹43.9 L+₹2.9 L (6.97%)Rejected-AOC 137 MODEL TOWN PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹43.9 L+₹2.9 L (6.97%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹45.4 L+₹4.4 L (10.6%)Rejected-AOC | ₹45.4 L+₹4.4 L (10.6%) | L5 | Rejected-AOC Rejected |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
30 Jan 2023, 6:00 pmClosed
Garrison Engineer(N) Mamun
Garrison Engineer(N) Mamun Pin-145001
SPECIAL REPAIR TO BLDG NO P-53, P-13 AND P-14 AND PROVN OF CHAIN LINK FENCING AT MD ACCN IN CANDETH ENCLAVE UNDER AGE B/R-II AND AGE B/R-I OF GE (N) MAMUN
2023_MES_572501_1
GE(N)/M-50/2022-23
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer(N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer(N) Mamun
₹92,000
22 May 2023
2 Jan 2023
1 Feb 2023
2 Jan 2023
30 Jan 2023
17 Jan 2023
Amount
Taking down chowkhats or frames n.exc 1.50 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frames exc 1.50 sqm but n. exc 4.0 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
M&L for Box type steel windows and ventilator comprised of tubular frame and shutters made out of 1.25 mm thick M S sheet tube factory made with double side shutters wire gauged shutter & glass/ glazed shutter (wire cloth and glass panes only shall be measured and paid seperately) with side hung shutters with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 150 mm long for each leaf and 10 mm square bar grills at spacing as shown on drg welded to FI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks etc all as shown on drg No CEPZ/TD-354/09 sheet 1/3 to 3/3 including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F pressed steel frame made out of MS sheet 1.25mm thick of size 125x60mm for doors/windows with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc including filling of concrete 1:3:6 type C-0 (12.50 mm graded stone aggregate) back of chowkhats and incl two coats of synthentic enamel paint over a coat of red oxide primer complete all as specified and directed.
All as per item 4 but size 105x60 mm
All as per item 4 but size 75x50 mm
S&F 35mm thick, 2nd class hard wood plain framed, panelled (factory made) shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces, The size of rail and stile as per IS-1003 (Part-I) (Larger size to be provided) kiln seasoned and chemically pressure treated fitted to chowkats complete all as specified and directed.
S&F 2nd class hard wood 35mm thick glazed and skeleton door shutters factory made, open rebated and prepared to receive glass or gauge etc with rounded, chamfered or mitred sash bars edges of framing plain chamfered or rounded fitted with cut and mitred beads and fitted to chowkats for securing glass/gauge, size of stiles rails and other parts as per clause 8.20 (a) of SSR Part-I 1991 (Larger size to be provided) complete all as specified and directed.
M & L preparation of new wood or wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
S&F Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm wood grain printed PVC sheet used instead f plain colour PVC sheet & edges will be painted to match with printed sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing complete all as specified and directed.
S & F Factory Made Solid PVC Moulded door Shutter With PVC Solid Core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick prelam Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed.
Hacking out old broken glass ( any thickness , size, quality, or description) from metal frame glazed with putty or fixed with beads/ clips, rubbish off the premises, complete all as specified and directed.
S&F stainless steel wire cloth 0.34 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks, or galvanized wire staples all as specified & directed.
M&L for prepration of new steel surface and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F 3 mm thick Figured glass, pin head type and glazing with oil putty or fixed with bead / glazing pins in squares size n.exc 0.5 sqm in each pane complete all as specified and directed.
S&F of 3 mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead / glazing pins in squares size n.exc 0.5 sqm in each pane complete all as specified and directed.
S&F 250 mm long aluminium alloy, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts complete all as specified and directed.
S&F for aluminium anodized barrel tower bolts 200 mm of extruded section complete all as specified and directed.
S&F 150 mm size aluminium alloy handles, febricated type extruded section, ISI marked complete all as specified and directed.
S&F in repairs 150 mm MS Rat tail door spring for door closer,complete all as specified and directed
Supply only SS butt hinges 100 mm, and fixed all as specefied and as directed.
Taking down cement plaster on brick walls or stone walls any descrition etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises complete all as specified and directed.
M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and as directed.
M&L for Rendering 5 mm thick cement plaster on faces of brick work or concrete surfaces in cement mortar (1:3) as in ceiling finished even and fair complete all as specified and directed.
M&L for Rendering 15mm thick in two layers (10+5mm) on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and directed
M&L for rendering or plastering work 10mm thick in CM 1:3 in fascia / edging / ceiling of Chajjas, roof projections etc, including taking out peeled off plaster / concrete and making the surface, edge in true shape/line and finished without using extra cement complete all as specified and directed.
M&L for Preparation of new plastered surface of external wall and chajjas and making the surface smooth with sand paper, priming the surface with alkali resistance primer paint for external surface, over primed surface, applying two coat of cement base paint incl curing complete all as specified & directed.
M&L for Preparing new wall/ chajjas/ facia surface including making surface clean, dry and free from any loose paint film, dirt, chalk, grease, fungus and algae and applying two coats of acrylic, antifungal emulsion exterior weather proof paint over a coat of primer on external surfaces, complete all as specified and directed.
M&L for Preparation of new plastered surface of walls making the surface smooth by applying wall care putty and applying two coats of oil emulsion distemper over a coat of primer complete all as specified & directed.
M&L for three coats of white wash on surface of wall including preparation of new plastered surface complete all as specified and directed.
M&L for three coats of white wash on surface of ceiling including preparation of new plastered surface complete all as specified and directed.
M&L for complete removal of existing treatment and preparation of old surface with mechanical sander and apply two coats of white wash on surface of wall including preparation of old plastered surface complete all as spd and directed.
M&L for one coats of white wash on surface of ceiling including preparation of old plastered surface complete all as specified and directed.
M&L for complete removal of existing treatment and preparation of old surface with mechanical sander including preparation of old surface by filling small holes with CM 1:4, making the surface smooth and applying two coats of cement base paint over a coat of alkali-resistant priming paint complete all as specified & directed.
M&L for complete removal of existing treatment and preparation of old surface with mechanical sander and applying 1mm thick wall care putty after filling small holes with CM 1:6 and making the surface smooth and applying two coats of Oil bound distemper over one coat of primer complete all as spd and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc. 15cm thickness and removal of debris out of premises complete all as specified and directed.
M&L for Cement concrete type C-1, 1:3:6 (using 20mm graded crushed stone aggregate) as in plinth protection and paving 75mm thick laid in slope finished even and fair incl making joints at every 2.5 m and at corner filled with bitumen 85/25 and sand in ratio 1:2 by weight complete all as specified and directed.
M&L for 25 mm thick PCC type B-0 (12.5 mm graded crushed stone aggregate) in flooring subbase/laveling layer complete all as specified and directed.
Dismantling old floor tiles including cement mortar bedding and removal of debris out of premises complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc set and jointed (joint free) in neat cement slurry and pointed in coloured cement over screed bed or bedding layers of mortars 15 mm thick in CM 1:6 for laying floor finishes complete all as spd and directed.
All as per item No 40 but in skirting/dado/risers of steps etc inclding taking down cement plaster on walls etc complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed of 10mm thick in CM (1:4), finished rough, incl demolition of floor, hearth or wall tiling, cement mortar backing/bedding and removing rubbish off the premises complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors and skirting etc, set and jointed in neat cement slurry and pointed in coloured cement over bedding layer of cement mortar in CM (1:6) incl dismantling wall tiling, cement mortar backing/bedding and removing rubbish off the premises complete all as specified and directed.
M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brusing neat cement slurry with 3.00 kg per sqm complete all as specified and directed.
M&L for green Marble work 15 mm thick (table rubbed and polished) in cooking plateform, window cill, steps, stair case trade & riser etc over bedding layer of 15 mm thick in cement mortar (1:4), pointed in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Bhaislana Zebra complete all as specified and directed.
M&L for Round chamfering to the edges of granite n.exc 15mm wide on granite stone shelves complete all as specified and directed.
S&F in repair Stop valve/ Angle valve cast copper alloy (ISI Marked) chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe 15mm bore dia, complete all as specified and directed.
S&F in repair Bib taps for 15 mm bore pipe, cast copper alloy fancy type chromium plated complete all as specified and directed.
S&F Brass CP sink mixer for mixing hot & cold water for 15 mm bore pipe, cast copper alloy fancy type chromium plated complete all as specified and directed.
S&F in repair Stop valve concealed cast copper alloy (ISI Markd) fancy type, chromium plated with long shank and cup (concealed type) screwed down high pressure with capstan head screwed both ends for iron pipe 15mm bore dia in repair, complete all as specified and directed.
S & F in repairs Vitreous china wash basin with padestal, white flat back, size 550 x 400 mm including waste pipe , brackets and cutting for and pinning in ends of brackets or errecting stand and 32 mm dia PVC waste pipe including waste coupling 32mm size full thread , complete all as specified and directed.
S&F in repairs 15mm bore pillar cock fancy type, screwed down high pressure with or without letters hot or cold with long screwed shank and fly nuts screwed for iron pipe ISI marked complete all as specified & directed.
S&F in repair towel rail CP 600 mm long with hooks on both ends complete all as specified and directed.
S&F Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed.
S & F in repair CP Shower rose 200X200 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
S&F in repair Vitreous China squatting pan of orissa pattern, size 580x440mm white with CI ‘P’ or ‘S’ trap, front or back inlet and foot rests, any pattern (including fixing of flush pipe) including provision of cement concrete bedding, complete all as specified and as directed.
S&F in repairs Vitreous china urinals size 465x355x265 mm with 32mm CP coupling & PVC waste pipe complete all as specified & directed.
S&F in repair PVC flushing cistern 10 ltr capacity incl PVC connection inlet and and outlet connections, brackets, PVC flush pipe with bend 32 mm dia of suitable length including making necessary connections to water supply pipe line and jointing to WC complete all as specified and directed.
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
Taking down eaves gutters and rainwater pipes 100 mm dia (any size or pattern), including all fittings, head, shoes, bend, swan-nacks etc. complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore, single socketd , in any length with rubber ring joints , in any length fixed to walls, end rest on PCC stay complete all as specified and directed.
S&F PVC (SWR) bend any radius 110mm dia bore complete all as specified and directed.
S&F 100 mm bore sand cast iron soil waste and vent pipes ISI marked in any length with or without ears laid in floor with cement joints including taking up/down old CI pipe of any description complete all as specified and directed.
All as per item No 64 above but fixed to walls with clamps .
S&F in repair 100 mm dia CI bends (any radius) diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
S&F in repair Cast Iron Branch peices, single (equal or unequal) ordinary or inverted (spigot or socket type), or with parrallel branches fitted with oval access doors of 100 mm bore complete , ISI Marked, complete all as specified and directed.
S&F 75 mm bore sand cast iron soil waste and vent pipes ISI marked in any length with or without ears laid in floor with cement joints including Taking up or down cast iron (sand cast) soil waste and vent pipes (including all fittings) and joints complete all as specified and directed.
All as per item 68 but fixed on walls.
All as per item 68 but 50mm bor fixed on walls.
S&F in repair 75 mm dia CI bends (any radius) diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
S&F in repair Cast Iron Branch peices, Double (equal or unequal) ordinary or inverted (spigot or socket type), or with parrallel branches fitted with oval access doors of 75 mm bore dia complete , ISI Marked, fixed in repairs complete all as specified and directed.
S&F in repair CI floor trap 100 mm with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) with CP grating with ot without hole for waste pipe complete all as specified and directed.
All as per item 73 but size 75 mm.
S&F in repair cast iron cowl for 50 mm dia complete all as specified and directed.
Taking up or down steel water tubing and connections including cleaning for refixing or removal to store, bore of pipe 15mm complete all as specified and directed.
All as per item 76 but size 20mm bore
Refixing of old steel tubing 15 mm bore medium grade galvanized ISI marked with new fittings, short pieces and fixed complete to walls, floor etc complete all as specified and directed.
All as per item 78 but size 20mm bore
S&F 15mm bore tubes medium grade galvanized ISI marked with all fittings short pieces and fixed complete to walls, floor, ceiling etc all as specified.
All as per item 80 but size 20mm bore
M&L for cutting chases pinning in brick work and making good to facing where required, pointing and making good in CM 1:3 cutting n.exc. 10 cm in girth complete all as specified and directed.
M&L for Rotational moulded polyethlene water storage tanks double layered, ISI marked of capacity 500 litres (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete including 20mm dia ball brass valve high pressure with polythene float including dismantling and taking down of existing PVC tank of any capacity complete all as specified & directed.
All as per item No 83 but capacity 1000 litres
S&F Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified & directed.
S&F in repair 20 mm bore dia gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed, cast copper alloy, chromium plated, fancy type ISI marked with crutch or butter fly handles screwed down screwed for iron pipe complete all as specified and directed.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen with plugs and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915x460mm bowl size 410mm x 330mm x 160mm, complete all as specified and directed.
S&F stainless steel kitchen plate rack of size 750 x 900 mm of approved make fixed with mild steel screw complete all as specified and directed.
M&L for 10 mm thick cement plaster in cement mortar 1:3 on brick or concrete surface of sunken floor finished even and smooth using WPC liquid of make Dr. Fixit or STP as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement complete all as specified & directed (WPC shall be measured and paid for separately)
M&L for bitumen blown grade, applied hot, two coats, to concrete/ plastered surfaces at the rate of 1.5 Kg per sqm per coat and applying polythene film black, 50 micron for sunken floor slab, embedded in side wall / covered fillet complete all as specified and directed.
M&L for 75mm thick PCC type B-1, 1:2:4 ( using 20mm graded stone aggregate) as in sub floors for laying floor finish in sunken floor complete all as specified and directed.
M&L Plain cement concrete 1:5:10 type E2 using 40mm graded stone aggregate as in sunken floors, filling as mass concrete complete all as specified and directed.
M&L for 20mm thick cement plaster in cement mortar 1:4 on concrete surface finished even and smooth using WPC liquid of make Dr. Fixit or STP as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition, removal of rubbish complete all as specified and directed
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
S&F Mild steel TMT bars 6mm to 8mm dia cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified & directed.
M&L for reinforced cement concrete 1:2:4 type B-0 (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns, in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary formwork complete all as specified & directed.
Taking down brick tiles, terracing tiles, single layer from roof laid, bedded and pointed in any mortar, rubbish of the premises complete all as specified & directed.
Demolition of cement concrete (unreinforced) of any description and in any position not specifically provided for, removing of rubbish complete all as specified and as directed.
M&L for PCC 1:2:4 type B-0 using 12.50mm graded stone aggregate as in roof padding, surface finished even and smooth without using extra cement complete all as specified & directed.
M & L for cement concrete (1:2:4) type B1 ( using 20 mm graded stone aggregate) as seismic, plinth and similar bands, coping, kerbs, cills, steps, parapets, apex stones, bed plates, kerbs, railings up to 60 cm in height, water troughs and the like rounded or chamfered on edges including necessary form work. ( Item also applied in broken RCC chajjas and roof projection ) complete all as specified & directed.
M&L for APP modified roof treatment over existing accessible RCC roof slab / chajjah / canopy / parapet wall to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufacture by the same agency as that of APP with a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm/Sqm using butane torch by torch application with 10cm side laps and 15cm end lap. Laying of membrane. (d) APP membrane shall be laid using butane torch by Torch application with minimum 10cm side overlap and 15cm end lap.
All as per item No 102 but on non accessible roof and top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg/Sqm as prescribed by manufacture of membrane.
M&L for 40mm thick brick tiles laid on cement mortar & joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement over and including 15mm thick screed bed or bedding layer of mortar in CM 1:6 etc complete all as specified & directed.
All as per item 104 but except brick tile using old serviceable brick tile retrieved from item here in before complete all as specified & directed.
Supply only liquid water proofing compound
M&L for Providing and injecting chemical emulsion for post construction anti-termite treatment along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 litre per linear meter including drilling and plugging of holes etc in apron/plinth protection complete all as specified in IS-Code 6313 Part (3) : 2001 and directed.
M&L for Providing and injecting chemical emulsion for post construction anti-termite treatment of soil under existing floors using chemical emulsion @ one litre per hole 300 mm apart along the junction of floor and wall, along joints in floors including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floor complete all as specified in IS code-6313 Part (3) : 2001 and directed.
Demolition of brickwork built in cement mortar including all quions, arches, pillars etc but excluding ashlar facings dressed stonework and pre cast concrete articles including rubbish off the premises complete all as specified & directed.
M&L for Brick work with fly ash bricks (Old Size bricks) straight or curved on plan exc 6 mtr mean radius built in CM (1:4) complete all as specified & directed.
S & F Curtain rails 20 mm, stainless steel including both sides bracket ,end bulbs, fancy type, fixed in postion as approved by Engr-in-Charge
M&L for 75 mm thk PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in subbase to flooring complete all as specified and as directed.
M&L for provide Sand cushion under floors or in foundation including watering and consolidation complete all as specified and as directed.
M&L for Precast interlocking paver blocks factory made confirming to IS-15658-2006 of 60 mm thick grade of concrete M-35 with cement and coloured pigment (topping thickness not less than 5 mm thick with white cement and colour pigment non fadable with epoxy coating) complete all as specified and as directed.
M&L for cement concrete type B-1 (1:2:4) (20 mm graded stone aggregate) as in kerb stones, coping, bed plates and the like including weathering, slightly roundered or chamfered angles and throating, as directed including necessary form work and finishing complete all as specified.
Excavation and trenches n. exc 1.5 m wide and n.exc 1.5m in depth for foundation of manhole, in any type of soil complete all as specified.
M&L for 150 mm thick concrete bed to drain pipes including benching under and haunching in cement concrete 1:3:6 type C2 for 150 mm bore pipe complete all as specified and directed.
M&L for 150 reinforced cement concrete pipes class NP2 with one collar per length of pipe complete all as specified and directed.
M&L for cutting into existing manholes (150mm dia pipe) for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch cahnnel(1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required, complete all as specified and directed.
S&F for 17-18 mm thick PVC prelaminated solid board with one side decorative choice laminate and other side balancing white and with weight of sheet not less than 9 kg per sqm as in kitchen cabinet, cupboard etc fixed with screws to steel/timber frame work etc complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and removing surplus soil to a distance n exc 50 mtr and making good surface complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, and removing surplus soil to a distance n exc 50 mtr and making good surface complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
Supply only 3.15mm dia galvanised steel wire chain link fencing mesh size 50x50mm including binding wire/line wire etc complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed.
Supply only Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips (Gd.I, IS 432 (Part I) complete all as specified and directed.
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, Diameter of shank 12mm, length of bolt exc 5cm but n exc 10cm long screwed end to be fitted with washers and one hexagonal or square nut, complete all as specified and directed.
S&F Mild steel ,Hand rails, half round or othercsteel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-410-0 or Fe-310-0 complete all as specified and directed.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-290 Gde E- 165 including dismantling existing structure etc complete all as specified and directed.
M&L preparation of new or previously un treated steel or iron surface, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in in foundations, filling and mass concrete including necessary form work complete all as specified and directed.
M&L PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in in foundations, filling and mass concrete including necessary form work complete all as specified and directed.
Taking down carefully unsv copper/aluminium point wiring (light/fan/Bell/socket or power) complete, including fixture and fittings such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sketch fitting etc removing materials to store for keeping in safe custody for taking credit and making good to disturb surface of wall/floor with cement mortar and finishes to match existing surface complete all as specified and directed.
M & L for point wiring using 3 x 1.5 Sqmm FRLS PVC insulated unsheathed /multi stranded copper conductor cable(Phase, neutral and earth wire) drawn through and incl concealed conduit medium grade of dia not less than 20mm and 1.8mm thick and connected to common earth dolly with 1.6 mm thick cadmium plated CI/GI pressed steel sunken boxes and 3 mm thick plastic laminated sheet cover fixed with brass screws including cutting grooves for concealed wiring for light/fan/bell point controlled by one 1way swtich complete all as specified and directed. Note: 1. Conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible. 2. Connections of cable with MCBs or switch/sockets shall be done through proper size copper/brass pin/U type thimbles.
All as per Ser item No134 above but for one light point controlled by two 2 way switch.
All as per Ser item No 134 above but for one 5 Amp socket outlet point on same board controlled by one switch 5 Amp one way.
All as per Ser item No134 above but for one 5 Amp socket outlet points controlled by one switch 5 Amps one way on independent board.
All as per Ser item No 134 above but for one bell/buzzer point controlled by one bell push 5 Amp 240V.
All as per item No. 134 here in before but for one above but one 15Amp socket point concealed with 3x2.5Sqmm FRLS PVC insulated multi-strand copper conductor.
S & F in replacement switch piano flush button single pole one way 5 Amp 240 volts, all as specified and as directed.
S & F in replacement socket outlet 2 in 1, 3 pin, 5 Amps, flush type with shutters, 240 volts all as specified and as directed.
S & F in replacement switch 15 Amps, flush type with shutters, 240 volts all as specified and as directed.
S & F in replacement socket outlet 2 in 1, 3 pin, 5 and 15 Amp flush type, 240 volts all as specified and as directed.
S & F in replacement switch bell push 5 amp 240 volts, all as specified and as directed.
S & F in replacement bell ding dong AC 230 volts, all as specified and as directed.
Supply and Fixing in replacement the switch flush button two way 10 Amp one module, front operated complete all as specified and directed.
S&F in replacement ceiling rose PVC/polycarbonate, insulated body surface Bakelite 65mm dia three terminals.
S&F in replacement fancy type Lamp holder jumbo, PVC/Polycarbonate type with back plate including 15Watt LED Lamp complete all as specified.
S&F in replacement 12Watt LED Lamp, 230 V retrofit suitable for any type lamp holder complete all as specified.
S & F in replacement stepped type electronic fan regulator flush type Socket type on the existing phenolic laminated sheet etc. not less than 100 W flush type.
Taking down carefully unsv copper/aluminium sub main wiring of any size including old broken steel/PVC conduit and removing materials to store for keeping in safe custody for taking credit complete all as specified.
S&F in replacement sub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x6 Sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 6 Sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in existing PVC concealed conduit complete all as specified and directed.
S&F in replacement 20W surface / wall mounted box type batten LED luminaire having PDC aluminium housing and PC diffuser and integrated electronic driver with high efficiency, CRI = 80 (Minimum), PF > 0.95, luminous efficacy ≥ 120 lumens/Watt operating voltage 140V-240V, CCT≥5700+/-300K, THD < 10% complete with all accessories internally prewired and including connecting up with 3 core flexible copper conductor cable of suitable size in flexible conduit pipe of suitable size from ceiling rose to connector of LED fitting complete all as specified and directed.
S&F in replacement surface mounted 10 Watt 2' box type LED batten as mirror light with wall mounting arrangment including connecting up with 3 core flexible copper conductor cable of suitable size in flexible conduit pipe of suitable size from ceiling rose to connector of LED fitting complete all as specified and directed.
S&F in replacement Energy saving, surface mounted, bulk head LED luminaire 10 W with PDC aluminium housing and polycarbonate diffuser complete including connecting up with three core twisted flexible copper conductor cable of suitable size.all as specified.
S & F in replacement SPN MCB DB 4 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 43 and IK 09 rating having fully insulated copper busbar of rating not less than 100Amps, insulated neautral bar, earth bar and cable ties for cable management including polyuthrene gasket complete all as specified and directed.
S & F in replacement SPN MCB DB 12 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 43 and IK 09 rating having fully insulated copper busbar of rating not less than 100Amps, insulated neautral bar, earth bar and cable ties for cable management including polyuthrene gasket complete all as specified and directed.
S&F in replacement MCB SP 240V, 50Hz of rating 6 to 32 Amp with breaking capacity of 10 kA having bi-connect terminals on the bottom terminals for looping and 35Sqmm termination capacity on both terminals with insulated sliding shutters and two position DIN rail clamp for easy mounting complete all as specified and directed.
All as per Ser item No 158 above but for size 32 Amps MCB SPN.
All as per Ser item No 158 here in before but for size 63 Amps MCB TPN.
S&F in replacement basic all purpose surface and wall mounted LED batten with polycarbonate housing & integral electronic driver 1x9 watt internally pre wired and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED Building light 1x20 watt with best in class design & Robust heat sink along with class leading IP, IK & surge including 32mm bore GI pipe bracted mounted using clamps, nuts bolts, washers, fastners etc complete all as specified and directed.
Taking down old exhaust fan, cleaning, greasing, servicing and carying out minor repairs such as replacemement fan blade screws, check nuts, lowers of suitable size including alteration of existing hole as per size, painting fan with synthetic enamel paint by spraying after filling cavities with filler one coat after cleaning all dust etc and refixing at same location, connecting up with 3core flexible copper flexible copper conductor of 0.5 sqmm complete all as specified and directed.
M&L for Earthing complete with Galvanised steel earth plate electrode of size 60 cm x 60 cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connecting to Galvanized earth lead wire 4.00mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel and earth lead protected by provision of GI medium grade pipe 15mm bore dia including 40mm thick cover of RCC (1:2:4) Type B-1 (using 20mm graded crushed stone Aggregate) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with 6mm dia MS bar handle made of shape, GI medium grade 20mm bore pipe for watering of suitable length placed on top edge of earth plate, common salt and charcoal filling, with fixing arrangements, funnel, wire mesh and earth work in any type of soil including returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I (specificetion) and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and as directed.
Deduct Total amount of SCHEDUL 'A' SECTION-II (SCH OF CREDIT) Rs 67,455.00 ( to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.
Abrol construction co
M/S CANTILEVER ENGINEERS
M/S DUGGAL CONSTRUCTION CO
M/S NARESH KUMAR SHARMA
RD Engineers
M/s Rajeev Vashist
Paramjit Singh and Co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .