Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹24.0 L+₹3.3 L (16.2%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 bidder | |
| 3 | L3₹24.6 L+₹3.9 L (19.1%)Rejected-Finance R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L3 | Rejected-Finance Being other than L1 bidder | |
| 4 | L4₹25.1 L+₹4.4 L (21.5%)Rejected-Finance 53 HOUSING BOARD COLONY PHASE II UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | J K | 182101 | L4 | Rejected-Finance Being other than L1 bidder | |
| 5 | L5₹26.8 L+₹6.2 L (29.9%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 bidder |
Tender Value
₹42.8 L
EMD Value
₹85,700
Closing Date
11 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN-913862 C/o 56 APO
SPECIAL REPAIR TO SECURITY LIGHT SYSTEM AND LT UG CABLES AT VARIOUS UNITS OF NAUSHERA UNDER AGE E/M OF GE 862 EWS
2023_MES_623224_1
GER-59/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
As per tender documents
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹85,700
Yes
22 Dec 2023
14 Oct 2023
13 Nov 2023
14 Oct 2023
11 Nov 2023
27 Oct 2023
Amount
Supply and erecting for steel tubular swaged poles errected to truly vertical position with 6mm thick mild steel base plate of size 300mm x300mm, welded to Pole, B-118 finial taper plug, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II, type 410 SP-22 (8.5m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint internally and portion embedded in concrete, making five black and white bands at lower portion of pole each 300mm wide at 300mm spacing alternately and marking pole number. with black paint at suitable height including taking down old unserviceable poles of any type complete all as specified and directed. (Note :- Necessary excavation of earth work, removing, returning filling in, PCC foundations of poles, coping etc shall be measured and paid separately)
S&F in repair for LED street light fitting 60 watts, made in pressure diecast housing with eppoxy power coated dark graphite grey colour finish, parismatic polycarbonate cover with individual LED lenses with IP 65, complete with all accessories and necessary fixing arrangement including three core 0.5 Sqmm copper cable from connector to fitting, complete all as specified and directed
Supply, laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 25 Sqmm 4 core laid in trenches, ducts, pipes, on poles and making connection with necessary cables lugs and glands including taking down old cable, complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling, sand cushoining, cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply, laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 16 Sqmm 4 core laid in trenches, ducts, pipes, on poles and making connection with necessary cables lugs and glands including taking down old cable complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling, sand cushoining, cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply, laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 Sqmm 4 core laid in trenches, ducts, pipes, on poles and making connection with necessary cables lugs and glands including taking down old cable complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling, sand cushoining, cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply, laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 35 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and making connection with necessary cables lugs and glands including taking down old cable complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling, sand cushoining, cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
Supply, laying, jointng and testing, XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 240 Sqmm 3.5 core laid in trenches, ducts, pipes, on poles and making connection with necessary cables lugs and glands including taking down old cable complete all as specified and directed. (Note :- Excavation of earth work, removing, returning filling, sand cushoining, cable cover and protection GI pipe shall be measured and paid separetly and length of cable shall be one length unless otherwise as directed by GE).
S&F for FRP looping / junction box of size 300x250x150mm with connector & four strip aluminium bus bar of capacity 63 amps mounted on epoxy insulator weather proof comprising of MCB SP 6 Amps-01 no, 240V complete with and including GI clamps-02 nos of 40x6mm flat with nuts, bolts etc suitable for fixing on wall / steel tubular pole and making connection with cable & thimbles of suitable size including taking down old U/S junction boxes complete all as specified and directed.
S&F for copper conductor cable, PVC insulated, sheathed, flexible, multistranded, ISI marked, 1100 Volts grade, 2 core 1.5 Sqmm and including connection and testing including taking down old unserviceable cable complete all as specified and directed
S&F for street light bracket made out of GI Pipe of size 32mm dia light grade of 1.2 m long bent to shape 120 degree duly fixed on wall/pole surface by providing suitable MS iron 32x3mm clamps 2 Nos of lenths as required at site to the bracket pipe and painting to MS clamps and fixing with necessary suitable nuts, bolts & washers including taking down old bracket complete all as specified and directed.
M&L for PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete of poles and stay/installation paths complete all as specified and directed.
M&L for PCC 1:3:6 (nominal mix) type C-1 (using 20mm graded crushed stone aggregates) as in all around the pole including necessary formwork complete all as specified and directed.
M&L for plain cement concrete type B-1 , 1:2:4 (using 20mm graded stone aggregate) as in coping of poles, benching, hold fasts, water troughs, bed block and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10sqm on plan for laying of cable and foundation of poles stays and getting out in soft / loose soil complete all as specified and directed.
All as per Srl item No 14.00 here-in-before but exceeding 1.5 m and not exceeding 3 m in depth and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm (soil) thickness all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed. (Note: Punned thickness of sand shall be measured and paid).
M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat, size 230mm x 115mm x 75mm, complete all as specified and as directed.
M&L in replacement for sheet metal enclosure MCB distribution board, double door, triple pole and neutral with IP-43, IK-09 protection 415 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete as all as specified and directed. (Note:- MCBs will be measured and paid separately.)
S&F for MCB single pole 415 volts, 40 amps conforming to IS 8828 to 1996, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F for MCB triple pole & neutral 415 volts, 63 amps conforming to IS 8828 to 1996, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
narayan construction
M/S Chib Engineers
vijay kumar gupta and co
CHOPRA CONSTRUCTIONS
M/S JIWAN SINGH
RAVI KUMAR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .