| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC | ₹34.6 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹36.0 L+₹1.4 L (4.13%)Rejected-Finance | ₹36.0 L+₹1.4 L (4.13%) | L2 | Rejected-Finance Being higher bid value |
| 3 | L3₹36.4 L+₹1.9 L (5.37%)Rejected-Finance NEAR CENTRAL SCHOOL BALASORE DIST BALASORE ORISSA 756 001 | BALASORE | BALASORE | ORISSA | 756001 | ₹36.4 L+₹1.9 L (5.37%) | L3 | Rejected-Finance Being higher bid value |
| 4 | L4₹37.0 L+₹2.4 L (7.03%)Rejected-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | ₹37.0 L+₹2.4 L (7.03%) | L4 | Rejected-Finance Being higher bid value |
| 5 | L5₹38.1 L+₹3.5 L (10.2%)Rejected-Finance AT PO CHANDIPUR BALASORE 756025 | BALASORE | BALASORE | ODISHA | 756025 | ₹38.1 L+₹3.5 L (10.2%) | L5 | Rejected-Finance Being higher bid value |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
4 Apr 2025, 6:00 pmClosed
GARRISON ENGINEER
GE I R and D Chandipur Post Chandipur PIN 756025
REPAIR REPALCEMENT OF CERTAIN FLAME PROOF SUB MAIN AND POINT WIRING DBs AND MCCBs MCBs FLAME PROOF FITTINGS LIGHTNING PROTECTION SYSTEM EARTHING AND ALLIED WORKS AT ITR AND LC AREA UNDER AGE E AND M CHANDIPUR AND REPAIRS TO DBs MCBs SUB MAIN
2024_MES_683214_2
8963/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE I R AND D CHANDIPUR
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE I R AND D Chandipur
₹70,000
Yes
29 May 2025
14 Mar 2025
5 Apr 2025
14 Mar 2025
4 Apr 2025
21 Mar 2025
Amount
NOTE (Applicable for all items) :- (i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates. (ii) The bidders / contractors are advised to quote same rate for same items as mentioned in Part-I & Part-II, if quored rates are different for same items, lower quoted rate shall be considered for same items as mentioned in Part-I & Part-II. For this account nothing extra shall be admissible by this Deptt. SCHEDULE 'A' PART-I (Chandipur Area)
Taking down flameproof aluminium point wiring of light, FLP power itch/socket etc. complete, including connected fitting and fixtures such as junction box,terminal box by unscrewing from board,metalic hose conduit (excluding flameproof luminaires,FLP rotary switches, FLP power switch/socket & plug to be measured seperately) from hangers and removing materials to store and keeping in safe custody for disposal as per credit schedule and making good dusturbed surfaces of walls, floors, etc. to match with existing and complete all as specified and directed.
M & L for flame proof point wiring with PVC insulated unsheathed heat resistance, FRLSH, single core copper cable Conforming to IS-694 of size 1.5 Sqmm with stranded copper conductor drawing through flame proof ERW steel surface conduit with all fittings and accessories for connecting FLP rotary switches, light fittings & fixtures etc including 1.5 Sqmm heat resistant and fire retardant copper conductor cable as in continuous earthing for One light / fan points controlled by one FLP rotary switch.
M & L for flame proof point wiring with PVC insulated unsheathed heat resistance, FRLSH, single core copper cable Conforming to IS-694 of size 1.5 Sqmm with stranded copper conductor drawing through flame proof ERW steel surface conduit with all fittings and accessories for connecting FLP rotary switches, light fittings & fixtures etc including 1.5 Sqmm heat resistant and fire retardant copper conductor cable as in continuous earthing for two light / fan points controlled by one FLP rotary switch.
M & L for flame proof point wiring with PVC insulated unsheathed heat resistance, FRLSH, single core copper cable Conforming to IS-694 of size 2.5 Sqmm with stranded copper conductor drawing through flame proof ERW steel surface conduit with all fittings and accessories for connecting FLP rotary switches, light fittings & fixtures etc including 2.5 Sqmm heat resistant and fire retardant copper conductor cable as in continuous earthing for two light / fan points controlled by one FLP rotary switch.
M & L for flame proof point wiring with PVC insulated unsheathed heat resistance, FRLSH, single core copper cable Conforming to IS-694 of size 4 Sqmm with stranded copper conductor drawing through flame proof ERW steel surface conduit with all fittings and accessories for connecting FLP rotary switches, light fittings & fixtures etc including 4 Sqmm heat resistant and fire retardant copper conductor cable as in continuous earthing for . 15 amps, independent, with cables One 3 pin socket outlet complete all as specified and directed.
S & F flame proof rotary switches with cable in LM6 single pole ON/OFF 10/16 Amps
S & F flame proof rotary switch including socket and plug combined in LM6 cable termination box of capacity 16 A, 250 V, 2 P+earth complete all as specified and directed.
S & F flame proof rotary switch including socket and plug combined in LM6 cable termination box of capacity 16 A, 250 V,4P+earth complete all as specified and directed.
Supply and fixing Flameproof/Weatherproof Flood light fitting wall mounted, aluminium alloy LM6 with IP66 degree of protection, of capacity 70 watt LED light with lamp, driver etc, light gray epoxy powder coated 1 no internal and 2 nos external earthing with SS hardware along with 2 nos 3/4" ET cable entries with suitable double compression brass nickel plated cable gland,type A toughened glass certified by CIMFR,Dhanbad for Gas Group IIC complete all as specified and directed
All as per item No.1.09 above but of capacity 120 W
All as per item No.1.09 above but of capacity 150W
Supply and fixing LED light fitting 1x30 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 66 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable complete all as specified and directed.
All as per item No. 1.12 above but of capacity 40W
M&L for submain wiring with two runs of PVC insulated, unsheathed FRLSH cable with multistranded copper conductor,1100 volt grade of size 2.5 sqmm, including one run of FRLSH grade 2.5 sqmm PVC insulated, stranded, copper conductor cable as earth wire drawn in and including flameproof ERW stove enamelled steel rigid of suitable dia with bend, elbow, couplings, GI saddle clips etc and connecting up complete including taking down old unserviceable submain wiring complete all as specified and directed by Engr-In-Charge (Note: Two runs of 2.5 sqmm wire and one run 2.5 sqmm FRLSH PVC cable and one run of suitable size ERW steel conduit shall be measured as one length)
All as per item No.1.14 above but of size 4.0sqmm
Taking down / dismantling old unserviceable Distribution Boards/Main Switch of any type / size and capacity.
Supply and fixing flame proof/weatherproof distribution board TPN 4 way size 420 x 420 x 250 mm with provision of incoming MCB TPN 63 Amps- 01 No and out going SP MCB 6 to 32 Amps -12 Nos including taking out old unserviceable DB complete all as specified and directed complete all as specified and directed.
Supply and fixing flame proof/weatherproof distribution board TPN 8 way size 480 x 480 x 250 mm with provision of incoming MCB TPN 63 Amps- 01 No and out going SP MCB 6 to 32 Amps -12 Nos including taking out old unserviceable DB complete all as specified and directed complete all as specified and directed.
M&L Earthing with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm buried directly in ground connected to galvanized earth lead strip of size 25 mm x 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron including 40mm dia light grade GI tubing for protection of earth lead, MS sheet metal funnel with wire mesh, watering pipe light grade 20mm dia, charcoal or coke and common salt in alternative layers of 15 cm compacted thickness all around the electrode with concrete earth pit with PCC type C1 , 1:3:6 (using 20 mm graded stone aggregate), 50mm thick precast RCC type B1, (1:2:4)(using 20 mm graded stone aggregate) pit cover reinforced with 8mm dia deformed bar and suitable handle made of 10mm dia round bar including galvanised strip of size 25mm x 4mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exc 50 mtr and necessary connection and testing complete all as shown in electrical plate No.3 of SSR Part-I, 2009 and all as directed including taking down old unserviceable one. (Note : GI strip upto 7.5 m length shall be deemed to include in the cost of above item.
All as per item No 1.19 above but using galvanised earthing lead strip of size 32mm x 6mm complete including taking out old unserviceable earthing matrials all as specified and directed.
All as per item No 1.19 above but using copper plate 60cm x 60cm x 3,15mm thick electrode and 20 x 3mm copper strip as earthing lead complete including taking out old unserviceable earthing matrials all as specified and directed.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required of galvanised iron strip of 25 x 4mm complete including taking down old unserviceable strip all as specified and directed.
All as per item No .22 above but GI strip 32 x 6mm all complete including taking down old unserviceable strip as specified and directed
All as per item No 1.22 above but copper strip 20 x 3mm complete including taking down old unserviceable strip all as specified and directed
Supply and fixing of single pointed air terminal Aluminum rod of 12mm dia and 300mm long.
S & F aluminium strip 25x3.15mm with saddle and fixing screws for roof conductors and down conductors above ground.
S & F Double action spring hinges, brass, of size 100 mm with phosphor bronze wire spring, bright polished complete all as specified and directed.
M&L for chemical Earthing with copper bonded MS Rod of dia 17.2mm, length 3 mtr buried directly in ground by drilling the hole of dia 100mm -125 mm augured to a depth not less than 3 mtr including filling of earth enhancement material consist of marconite conductive aggregate and portland cement completely filled inside the hole and connecting of copper earthing lead strip of size 20X3 mm welded/ nuts and washers with main electrode protected with 40mm dia light grade GI tubing for protection of earth lead complete with PCC type C1 , 1:3:6 (using 20 mm graded stone aggregate), 50mm thick precast PCC type B1, (1:2:4)(using 20 mm graded stone aggregate) and pit cover reinforced with 8mm dia deformed bar and suitable handle made of 10mm dia round bar including copper strip of size 20mm x 3 mm for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spoils to a distance not exc 50 mtr and necessary connection and testing complete all as directed by Engr-In-Charge (Note : Copper strip upto 7.5 m length shall be deemed to include in the cost of above item.
SCHEDULE 'A' PART-II (Balasore & Nilgiri Area)
S&F MCB DB made of sheet steel phosphatised, powder painted double door with bus bar, neutral link, earth bar and din rail of SPN 4 way, 240 Volts fixed in wall,making good disturbed surfaces, including taking out old DB with fittings & fixtures complete all as specified.
S&F MCB DB made of sheet steel phosphatised, powder painted double door with bus bar, neutral link, earth bar and din rail of SPN 8 way, 240 Volts fixed in wall,making good disturbed surfaces, including taking out old DB with fittings & fixtures complete all as specified.
S&F MCB DB made of sheet steel phosphatised, powder painted double door with bus bar, neutral link, earth bar and din rail of SPN 12 way, 240 Volts fixed in wall,making good disturbed surfaces, including taking out old DB with fittings & fixtures complete all as specified.
S&F MCB DB TPN 4 way having degree of protection as per IP 42 or above with metal door (double door) 415 Volts complete copper bus bar with neutral link with provision for MCB TPN as incomer and MCB SPN MCBs as outgoing with blanking plates, required size cable lugs etc fixed in wall,making good disturbed surfaces, including taking out old DB with fittings & fixtures complete all as specified.all as directed.
Taking down Sub main /Sub circuit wiring of any type and size including conduit / casing capping / batten wiring complete all as directed.
M&L for Circuit/Submain wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 6 Sqmm to be drawn in and including PVC concealed conduit 25 mm dia (medium grade). Note: Three runs of 6 Sqmm copper wire and one run of conduit pipe shall be measured as one unit.
All as per Sl Item No 2.06 above but in PVC casing caping (medium duty) of size not less than 20 mm width
M&L for Submain/Sub circuit wiring using three runs of FRLSH grade PVC insulated unsheathed, multistranded, copper conductor cable of size 4 Sqmm to be drawn in and including PVC concealed conduit 25 mm dia (medium grade). Note: Three runs of 4 Sqmm copper wire and one run of conduit pipe shall be measured as one unit.
All as per Sl Item No 2.08 above but in PVC casing caping (medium duty) of size not less than 20 mm width
Taking down carefully copper /aluminium point wiring (light, fan ,socket or power) complete, including fixture and fittings such as switches, ceiling rose, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC rigid conduit (medium grade) of size not less than 20 mm dia concealed in wall/ceiling, etc. and conduit accessories with concealed wiring, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan point controlled by one 5/6 amps, one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
All as per Sl Item No. 2.11 here in above but for one light point controlled by two two way switches.ditto complete all as specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (medium duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one light / fan point controlled by one 5/6 amps, one way switch including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (medium duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 5/6 amps socket outlet on independent board including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (medium duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for for one 5/6 amps socket outlet on same board complete all as directed and specified.
M&L Point wiring with two runs of FRLSH grade PVC insulated unsheathed mulri-stranded copper conductor of size 4 Sqmm (phase & neutral) and one run of 4 Sqmm FRLSH grade PVC insulated unsheathed multi-stranded copper conductor for earth continuity wire to be drawn in and including PVC casing caping (medium duty) of size not less than 20 mm width and accessories, sunk MS sheet metal switch/Terminal box 1.2 mm thick and hylum switch board cover 3.0 mm thick fixed with brass screws with cap washers for one 6/16 amps socket outlet on independent board including all necessary wall cutting and making good disturbed surface with cement mortar 1:6 or PCC 1:3:6, type C-0 and matching with existing surfaces complete all as directed and specified.
S&F Switch piano, flush type, single pole, one way 5 Amps, 240V complete all as directed.
S&F Switch piano, flush type, single pole, one way 15 Amps, 240V complete all as directed.
M&L Socket outlet 2 in 1, 3 pin, 5 amp flush type controlled by one switch.
M&L Socket outlet 2 in 1, 3 pin, 5 and 15 amp flush type controlled by one switch.
M&L switch piano, flush type single pole, two way 5 Amps including connection.
S&F in repairs including connection of modular switch one way 6 Amps 1 Module complete all as specified and directed.
S&F in repairs including connection of modular switch one way 16 Amps 1 Module complete all as specified and directed.
S&F in repairs including connection modular socket outlet 2 /3 pin 6 Amps 2 modules complete all as specified and directed.
S&F in repairs including connection modular socket outlet 2 /3 pin 6/16 Amps 2 modules complete all as specified and directed.
S&F in repairs including connection modular Fan step regulator, 120W - 2 module complete all as specified and directed.
S&F in repairs white modular cover plate with frame 6 Module complete all as specified and directed.
S&F in repairs white modular cover plate with frame 8 Module complete all as specified and directed.
S&F call bell Dingdong, 230 V AC, single pole
S&F Bell push, flush type , 5 Amp
M & L ceiling rose PVC poly carbonate, isolated body with three terminals including connection.
M & L stepped type electronic fan requlator flush type 230/240 volts complete all as specified
M&L lamp holder angular type PVC / Polycarbonate type insulated body with back plate suitable.
S&F in replacement MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 16 kA, 415 Volts, 63 Amps including necessary lugs,wiring etc.
S&F in replacement MCCB 4 pole, with fixed thermal & magnetic release of breaking capacity 16 kA, 415 Volts, 100 Amps including necessary lugs,wiring etc.
S&F in replacement RCCB 4 pole, of breaking capacity 10 kA, 415 Volts, 63 Amps including necessary lugs,wiring etc.
S&F in replacement Supply and fixing 415V 10KA,four pole MCB 'C' series 80 to 100 AMP current carrying capacity in the DB complete with connection testing and commissioning.
S&F in replacement MCB, SPN. 40-63 Amps rating 240, volt, 'C' series, 10 kA
S&F in replacement MCB, SP, 6-32 Amps, 240 volt, 'C' Series, 10 kA
S&F in replacement Highly robust batten suitable to use with T8 LED Tube light fitting 20 Watt, indoor decorative type luminaire complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed.
S&F in replacement LED T8 Tube rod with in built driver in pc housing double sided connection of capacity 20 watts all as specified and directed.
S&F in replacement High-quality design LED batten light in extruded aluminium housing with high quality PC diffuser 20 watt with enhances safety and relible ,robust housing structure with decorative end caps complete with all accessories including LED tubelight internally pre-wired with capacity of 100 lumen/watt complete all as specified and directed.
S&F in repair LED Bldg security light fitting 45 Watt with all accessories, LED street light with pressure die-cast housing, high performance polycarbonate optics and IP66 ingress protection. Top opening driver cover for easy maintenance. Efficiency 120 lm/W.,for mounting bracket of 40mm bore GI pipe light grade complete with all accessories including taking down old fitting as directed.
Supply & Fixing of GI pipe bracket of 40 mm dia grade pipe bend to shape of approx length 1.5 mtr including 2 no MS clamp of flat iron size 40×6 mm complete with nut bolt washer all as specified and directed.
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25 x 4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed.
Material and labour in replacement for Galvanised iron strip 25 x 4 mm burried in ground complete all as specified and directed.
Supply and laying as in replacement 40mm bore GI pipe "light grade" with all fittings and fixed to walls, floor etc complete all as specified and as directed.
Cleaning, servicing including carrying out preventive maintenance of summer appliances viz. indoor and out door unit of Split Air conditioners of capacities 1.5 TR using suitable cleaning solution, chemicals, tools and minor spares viz. screws, washers, insulation tapes, thimbles, PVC fasteners etc. as per site requirement and as directed. Cleaning of the condensor, evaporator, fins and cooling coils shall be done using Blower / Vacuum cleaner, cleaning clothes, nylon brushes etc till scales and dirts are removed including cleaning of drain pipe line and replacement of unserviceable spares if any and ensuring its serviceability by keeping the AC in good working condition all as specified and directed by Engineer-in-Charge. Note :- 1. During servicing work, if any major fault is observed, the machine will be repaired under respective item of the schedule under Supply and fix in repair work, and thereafter servicing will be undertaken and completed. 2. Spares required for repair of unserviceable machines if any will be measured and paid under respective item of this schedule as "Supplied only" items. However, for servicing work, cost of minor spares to be replaced if any and not specified in this schedule viz. screws, washers, teflon seal, rubber bush, insulation tape, copper thimble, copper connecting jack, short length connecting wire, markers etc upto Rs 100 is deem to be included in the rate of the item. 3. Cost of taking down, reinstallation and transportation if required for the servicing / repair work is deem to be included in the price. 4. Servicing and repair work will be carried out within the contract period as and when required as per the site requirement and as directed by Engg-in-Charge.
Cleaning, servicing including carrying out preventive maintenance of summer appliances viz. indoor and out door unit of Window type AC 1.5/2 TR Capacity using suitable cleaning solution, chemicals, tools and minor spares viz. screws, washers, insulation tapes, thimbles, PVC fasteners etc. as per site requirement and as directed. Cleaning of the condensor, evaporator, fins and cooling coils shall be done using Blower / Vacuum cleaner, cleaning clothes, nylon brushes etc till scales and dirts are removed including cleaning of drain pipe line and replacement of unserviceable spares if any and ensuring its serviceability by keeping the AC in good working condition all as specified and directed by Engineer-in-Charge. Note :- 1. During servicing work, if any major fault is observed, the machine will be repaired under respective item of the schedule under Supply and fix in repair work, and thereafter servicing will be undertaken and completed. 2. Spares required for repair of unserviceable machines if any will be measured and paid under respective item of this schedule as "Supplied only" items. However, for servicing work, cost of minor spares to be replaced if any and not specified in this schedule viz. screws, washers, teflon seal, rubber bush, insulation tape, copper thimble, copper connecting jack, short length connecting wire, markers etc upto Rs 100 is deem to be included in the rate of the item. 3. Cost of taking down, reinstallation and transportation if required for the servicing / repair work is deem to be included in the price. 4. Servicing and repair work will be carried out within the contract period as and when required as per the site requirement and as directed by Engg-in-Charge.
All as per Sl Item No. 2.49 above but for water cooler of capacity 60 Liters . The inner water tank of water cooler should be cleaned using bleaching powder and keeping the inner tank clean from bacteria and formation of scales and ensuring its serviceability all as specified and as directed.
Supply only thermostat for water cooler of any capacity and make.
Supply only relay for any type of water cooler of any capacity & make.
Supply only PCB suitable for split type A/C 1.5 TR capacity of any make/ model
Repair of old PCB fitted in existing split type A/C 1.5 TR capacity of any make/ model, opening up for inspection/checking and make sure the serviceability of incoming/outgoing connections etc and reassembling the same with dismantled component after replacement of burnt spare parts and internal wiring complete all as directed and specified.
Supply only Digital Display Unit suitable for split / window type A/C 1.5/ 2 TR of any make and model.
Supply only Air sensor suitable for split / window type A/C 1.5/2.0 TR of any make/ model
Supply only Coil sensor suitable for window / split type A/C1.5/ 2 TR of any make/ model
Supply only Running capacitor 45/45+6 mfd for Window / Split type Air conditioner of of any capacity.
Supply only Running Capacitor capacitor 50/50+5 mfd for Air conditioner 2 Ton Capacity
Supply only capacitor of 6 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model .
Supply only capacitor of 8 mfd capacity suitable for all split / wiondow type AC Blower Fan of any make and model.
Supply only auto swing motor for indoor unit of split A/C of capacity 2/1.5 TR of any make and model to match with existing design conditions.
Supply only Thermostat for Window AC of capacity 1.5 TR/2.0 TR to match with existing design conditions.
Supply only blower drum suitable for Split/Window type AC of any capacity and to match with existing design conditions..
Supply only PVC Drain pipe of size 1/2" size suitable for Split type AC of any capacity.
Supply only , main Drain pipe of indoor unit of size 3/4 ", PVC Flexible type suitable for Split type AC of any capacity.
Supply only Rubber Bush for Fan Motor of out door unit of split type AC and Window type AC of any capacity and any make and model .
M/L for Gas charging with R-22 refrigerant gas for Split / Windows ACs of any make, model and capacity, Refrigerator and Water coolers of any make, Model of any capacity in position or by taking down including leak testing to achieve desired suction pressure and temperature and all as directed by Engg-in-Charge. Note: Leakage or loss of gas due to imperfect workmanship will not be measured. Only the qty of gas utilised as per design of machine will be measured after successful gas charging.
M/L for Gas charging with R-407/R-410/R-410A/R32 refrigerant gas for Split / Windows ACs of any make, model and capacity, Refrigerator and Water coolers of any make, Model of any capacity in position or by taking down including leak testing to achieve desired suction pressure and temperature and all as directed by Engg-in-Charge. Note: Leakage or loss of gas due to imperfect workmanship will not be measured. Only the qty of gas utilised as per design of machine will be measured after successful gas charging.
Supply and fixing in repair, Out door Bracket ISI marked suitable for fixing out door unit of Split type ACs of any make and capacity along with MS clamps, bracings, supports, bolts, nuts & washers, PVC rawl plug etc and making good disturbed surface of wall in CM 1:3 including painting to match with existing surface and all as directed.
M/L for carrying out spray painting complete unit of window type AC of any make, model and capacity after dismantling, and painting on sheet metal enclosers interanally and externally with two coats of synthetic enamel paint of approved make and shade after preparation of surface and writing the MES/SM Nos, re-assembling and reconnecting the AC unit at its installed location complete all as directed.
All as per item No. 2.72 above but for outdoor unit of split AC of any capacity make and model.
Repair of voltage stabilizer of any capacity ( 1 to 5 KVA) and make, opening up for inspection/checking serviceability of voltage regulating transformer relays, circuit board, voltmeters, incoming/outgoing connections etc and reassembling the same with dismantled component after replacement of burnt spare parts and internal wiring complete all as directed and specified by Engineer-in-Charge. Note. Replacement of spare parts shall be measured and paid separately under items below :-
Supply only transformer of any capacity between 4 to 5 KVA including taking down.
Supply only square/ round type voltmeter of size 2" x 2" for various voltage stabilizers including taking down.
Supply only transformer relay for various capacity of stabilizers including taking down.
Supply only circuit board for various capacity of stabilizer including taking down.
Supply only 3 way connector for voltage stabilizer including taking down
Supply & Fix in replacement polythylene soft thermocol of size 180x90x4 cm for window type AC side packing during AC installation
Taking down of RO water purifier (Kent/aquaguard/usha) for repairing, servicing, cleaning etc, replacement of unserviceable parts such as PCB, all filters, membrane, solenoid valve, uv lamp and other minor parts completete all as directed and specified
Taking down geysers carrying for repairing, servicing, cleaning etc, replacement of thermostat, heating element, indicator lamp and thermal cut out incl fixing of PVC cable, sheathed, three core with stranded copper conductor of size 2.5 sqmm and refixing the geysers at location for 25 litres Capacity :- (Note:- Heating element, thermostat etc shall be measured and paid separately as supply only)
Taking down geysers carrying for repairing, servicing, cleaning etc, replacement of thermostat, heating element, indicator lamp and thermal cut out incl fixing of PVC cable, sheathed, three core with stranded copper conductor of size 2.5 sqmm and refixing the geysers at location for 50 litres Capacity :- (Note:- Heating element, thermostat etc shall be measured and paid separately as supply only)
Supply only heating element 1.5 KW, 230 volt round/ triangular in shape ISI marked complete
Supply only heating element 2 KW, 230 volt round/ triangular in shape ISI marked complete
Supply only thermostat ISI marked complete suitable for 25liters capacity geyser
Supply only thermostat ISI marked complete suitable for 50 liters capacity geyser
Supply and replace front PVC grill suitable for window type AC cap 1.5 ton as per existing sample.
Supply and fixing as in replacement for upvc inlet/outlet connector pipe 450mm long for geyser,with brass coupling both ends sutiable to fix inlet/outlet of geyser complete all as specified and as directed.
Supply and fixing as in replacement for apparatus plate , including anchor bolt suitable for water storage heater of 25/50 ltrs capacity complete all as specified and as directed.
Rekha Enterprises (BID ID -3271905)
M/S T.N.CONSTRUCTION (BID ID -3272345)
KRISHNA ENTERPRISES (BID ID -3272572)
DS ENTERPRISES (BID ID -3272185)
Rounaq Enterprise (BID ID -3270945)
M/SNeelachal Enterprises (BID ID -3272761)
Bidder Name
DS ENTERPRISES
ALLIANCE
Rounaq Enterprise
KRISHNA ENTERPRISES
Rekha Enterprises
M/S T.N.CONSTRUCTION
M/SNeelachal Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .