Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹2.4 L
EMD Value
₹4,860
Closing Date
6 Nov 2024, 4:00 pmClosed
Estates Officer
Estates Division, SKUAST-J, Chatha
Construction of one room in the Beekeeping Unit under HADP Project Promotion of Beekeeping at Main Campus, Chatha
2024_SKUST_261049_5
AU/Estates/2024-25/06 dated 14-10-2024
Open Tender
Civil Works
Item Rate
120 days
Main Campus Chatha
Please refer tender documents
4 documents required · 4 mandatory
₹500
Assistant Comptroller Estates SKUAST Jammu
₹4,860
19 Nov 2024
18 Oct 2024
7 Nov 2024
18 Oct 2024
6 Nov 2024
18 Oct 2024
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth: consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering. All work upto plinth level.
1:3:6 (1 Cement : 3 coarse sand(zone-III) : 6 graded stone aggregate 20 mm nominal size).
1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- All work upto plinth level.
1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness). Including attached pillasters, buttresses, plinth and string courses fillets columns, pillers, piers, abutments, posts and struts etc. upto floor 5 level exclusing cost of centring shuttering, finishing and reinforcement.
1:1.5:3 (I cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size)
Centring and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns etc. for mass concrete.
Suspended floors, roofs, landings, balconies and access platform.
Lintels, beams, plinth beams, girders, bresumers and cantilevers.
Edges of slabs and breaks in floors and walls.
Under 20 cm wide
Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete
Cold twisted bars/ mild steel and MT steel
Brick work with FPS bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1: 6 (1 cement: 6 coarse sand)
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer
Using M.S. angles 40x40x6mm for diagonal braces
12 mm cement plaster of mix : Inside plaster
1:6 (1 cement: 6 fine sand)
Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work, over and including water thinnable priming coat to give an even shade
Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
Wiring for Circuit/sub main wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2x2.5 sq mm + 1x0.75 sqmm
Wiring for light / fan / exhaust fan / call bell point with 1.5 Sq mm FRLS PVC insulated copper conductor cable in surface / recessed medium class PVC conduit with Piano type switch, phenolic laminated sheet suitable size, M.S. box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required.
Supply and fixing of the following way, single pole and neutral / three pole and neutral, sheet steel, double door, phase segregation type, MCB distribution board, 230V / 415V on surface/recess, complete with tinned copper bus bar, neutral bus bar and link, earth bar, din bar, detachable gland plate, interconnections, including painting, earthing, etc., as required.
8 way SPN DB
Wiring for power plug with 2 x 4 sq.mm. ISI marked PVC insulated copper conductor single core cable in surface / recessed ISI marked PVC conduit along with 1x4.0 Sq mm copper wire for loop earthing as required
Supplying & laying of 2x16 sqmm aluminium cable complete connection testing etc as reqd.
ARJIT KUMAR (BID ID -2217316)
Nittan kumar (BID ID -2217829)
DEEPAK INDUSTRIES (BID ID -2217515)
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .