Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.3 LAccepted-AOC 53 VAISHAILI ENCLAVE SECTOR 9 INDIRA NAGAR LUCKNOW | LUCKNOW | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹47.2 L+₹4.9 L (11.6%)Rejected-Finance | L2 | Rejected-Finance Being L2 |
Tender Value
₹42.4 L
EMD Value
₹84,718
Closing Date
16 Jan 2024, 2:30 pmClosed
Superintending Engineer
University Work Department,BHU
Special Repair of HVAC System installed for Trauma Centre, IMS, Banaras Hindu University,Varanasi
2024_BHU_789159_1
UWD/2024/06012024-1
Open Tender
Electrical Works
Works
30 days
UWD BHU VARANASI
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Superintending Engineer UWD BHU
₹84,718
9 Feb 2024
6 Jan 2024
16 Jan 2024
6 Jan 2024
16 Jan 2024
6 Jan 2024
6 Jan 2024 - 9 Jan 2024
Amount
Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required
Providing & fixing in position the mercury in glass industrial type thermometers.
Supplying, fixing, testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified. 80 mm dia.
SITC Of Lube oil
SITC Of Oil Filter
SITC Of Shut off Valve
SITC Of Drier Core
Supply and fixing of Canvas connection of OT - 2 AHU of 3000 CFM (400x400MM) Fire proof material
Overhauling of Secondary Chilled Water Pump (25HP) including dismantling, replacement of defective bearings, remetaling of shaft, polishing, reassembling and commissioning of the same.
Overhauling of Hot Water Pump (7.5HP) including dismantling, replacement of defective bearings, Mechanical seal remetaling of shaft, polishing, reassembling and commissioning of the same.
Repairing of the Basin of Cooling tower including supply of resin and other chemical and parts complete as Per below. FRP SEALING Compound
Repairing of the Basin of Cooling tower including supply of resin and other chemical and parts complete as Per below. Splash Cap with steel screw
Repairing of the Basin of Cooling tower including supply of resin and other chemical and parts complete as Per below. PVD END CAP 63 mm dia.
Repairing of the Basin of Cooling tower including supply of resin and other chemical and parts complete as Per below. PVC pipe 63MM X10 feet long
Repairing of roof and base of air washer with Aluminum frame work 25 mm thick insulated panel. Density of insulation 38 ± 2kg\m3, Replacement Evaporative Cooling pad, Drift eliminator,. Evaporative cooling Pad
Repairing of roof and base of air washer with Aluminum frame work 25 mm thick insulated panel. Density of insulation 38 ± 2kg\m3, Replacement Evaporative Cooling pad, Drift eliminator,. Roof and base 35 MM thick insulated with supporting frame
Repairing of roof and base of air washer with Aluminum frame work 25 mm thick insulated panel. Density of insulation 38 ± 2kg\m3, Replacement Evaporative Cooling pad, Drift eliminator,. One mono block pump (0.5HP ) make ;Crompton
Repairing of roof and base of air washer with Aluminum frame work 25 mm thick insulated panel. Density of insulation 38 ± 2kg\m3, Replacement Evaporative Cooling pad, Drift eliminator,. Pre Filter of size( 675X665X50)MM
Supply and fixing of Canvas connection of Air Washer(1200X1200 MM) Wire proof.
Descaling and cleaning of cooling coil/Heating Coil of AHUs/CSUs with the help of descaling compound, soft cleaning agent, pressure pump etc. as required.
Descaling and cleaning of cooling coil/Heating Coil of FCUs with the help of descaling compound, soft cleaning agent ,pressure pump etc. as required.
Dismantling, repairing and fixing of Heating Coil of AHU installed in OT - 7 including lifting shifting of the same to the storage.
Dismantling, repairing and fixing of Cooling Coil of CSU installed in Blood Bank including lifting shifting of the same to the storage.
SITC of Thermostat of FCU Unit (Make: Honeywell/ Siemens/ Equivalent)
SITC of( 300mmx575mm) With circular frame Stainless Steel Pot Strainer Jali
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 50 MM
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 65 MM
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 80 MM
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 100 MM
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 125 MM
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 150 MM
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 200 MM
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 250 MM
SITC of Insulation on chilled water piping with Closed Cell Elastomeric Nitrile Rubber of density 50+/-10 Kg/CMT of specified thickness 32 mm suitable and thermal conductivity 0.037 W/MK for indoor application and mechanically protected with two layers (07 mil thick each layer) of adhesive and Glass Cloth / CSM of Following Pipe Size. 300 MM
Humidity and temperature device with display make -Siemens ,Honeywell
Amit Electricals
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .