Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAccepted-AOC B 303 TORAN CHSL RAJENDRA NAGAR DATTA PADA ROAD BORIVALI E MUMBAI 400066 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400066 | ₹39.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹41.2 LRejected-Finance H 4 SURYA VIHAR CO OP HO SO LTD BEHIND MUNICIPAL OFFICE ADARSH ROAD KULGAON BADLAPUR E DIST THANE 421 503 | BADLAPUR | THANE | MAHARASHTRA | 421503 | ₹41.2 L | L2 | Rejected-Finance L2 |
| 3 | L3₹41.5 LRejected-AOC | ₹41.5 L | L3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | Shree Sai Enterprises L1 | Amit Engineers L3 | Shree Siddhivinayak Industries L2 |
|---|---|---|---|---|---|---|
| 1.00M&R to Sinner WSS.... Comprehensive annual maintenance contract for HT Panel Board & other misc works @ Raw water work Palse Jackwell. ( Est. Cost Rs. 39,95,040.00) | ||||||
| 1.01 | Comprehensive Annual Maintenance (AMC) of 11 KV panel & 3.3 KV panel at RWW including checking of contacts of Load Break switch, contactor, VCB etc., checking operations of 11 KV/3.3KV breaker & allied accessories in panel, cleaning of panels by blower & tightening of all connections, checking of relays & its settings, functional checking of all power & control circuit, checking insulation resistance, replacement of spares if necessary etc. complete including Comprehensive Annual Maintenance (AMC) of 3.3 KV capacitor panel & APFC panel with checking all circuits, tightening of all connections, cleaning of panels by blower, fault finding to maintain the power factor, replacement of spares such as indicating lamps, tripping coil, closing coil, breaker motor, control fuses, P.T fuses, HRC fuses, protection relay, Master trip relay, annunciation (Window), 10A MCB, HT Capacitor, HT APFC relay, 110 V DC auxiliary contactor if necessary etc. complete. | 12 | JOB PER MONTH | 1,58,150 ₹19.0 L | 1,64,481.2 ₹19.7 L | 1,63,000 ₹19.6 L |
| 1.02 | Comprehensive Annual Maintenance (AMC) of 3.3 KV soft starter panel at RWW including cleaning of panel, tightening of all connections, checking of setting of relays, timer, protection system, space heater etc. checking functioning of all components, replacement of spares such as relay ,timer, 16 A MCB, 110 V DC auxiliary contactor, 110 V DC vaccum contactor, 250w/ohm resistance, wires, lugs etc. complete.(excluding replacement of Breaker, FCMA Unit) | 12 | JOB PER MONTH | 52,900 ₹6.3 L | 55,016 ₹6.6 L | 54,500 ₹6.5 L |
| 1.03 | Comprehensive Annual Maintenance (AMC) of battery backup and charger in the pump house at RWW consisting of 110 Volts DC batteries battery charger panel including checking battery terminal connections, checking electrolyte in battery, checking control circuits of battery charger, fault finding & its rectification etc. including replacement of spares complete.(excluding replacement of battery) | 12 | JOB PER MONTH | 14,100 ₹1.7 L | 14,716 ₹1.8 L | 14,600 ₹1.8 L |
| 1.04 | Comprehensive maintenance of 11/3.3 KV Outdoor type switchyard at RWW including all accessories excluding oil filtration & rewinding of Transformer. | 12 | JOB PER MONTH | 42,500 ₹5.1 L | 44,174 ₹5.3 L | 43,750 ₹5.3 L |
| 1.05 | Comprehensive Annual Maintenance (AMC) of LT Switchgear/Starter panel at & RWW & including checking healthiness of D.C. trip system, checking contacts of contactor, VCB, checking relay setting, functional check of all switchgear, tightening of all power & control cable connections, checking insulation resistance, cleaning of panel etc. including replacement of spares such as relay, timer, control contactor, metering equipment‘s, indicating lamps, push buttons etc complete.(excluding replacement of Breaker, FCMA Unit) | 12 | JOB PER MONTH | 65,200 ₹7.8 L | 67,849.6 ₹8.1 L | 67,250 ₹8.1 L |
Tender Value
₹40.0 L
EMD Value
₹40,000
Closing Date
6 Feb 2026, 11:00 amClosed
EE Nashik
Satpur, Nashik
M and R to Sinner WSS.. Annual Comprehensive maintenance for 11 and 3.3 KV HT Panel Board and other misc works at Raw water work Palse Jackwell. Rs. 3995040.00
2026_MIDC_1271585_1
M and R to Sinner WSS..Annual Comprehensive maintenance for 11 and 3.3 KV HT Panel Rs. 3995040.00
Open Tender
Electrical Works
Sinnar nashik
Please refer Tender Document
2 documents required · 2 mandatory
₹10,030
₹40,000
7 Apr 2026
23 Jan 2026
9 Feb 2026
23 Jan 2026
6 Feb 2026
28 Jan 2026
23 Jan 2026 - 25 Jan 2026
M&R to Sinner WSS.... Comprehensive annual maintenance contract for HT Panel Board & other misc works @ Raw water work Palse Jackwell. ( Est. Cost Rs. 39,95,040.00)
Comprehensive Annual Maintenance (AMC) of 11 KV panel & 3.3 KV panel at RWW including checking of contacts of Load Break switch, contactor, VCB etc., checking operations of 11 KV/3.3KV breaker & allied accessories in panel, cleaning of panels by blower & tightening of all connections, checking of relays & its settings, functional checking of all power & control circuit, checking insulation resistance, replacement of spares if necessary etc. complete including Comprehensive Annual Maintenance (AMC) of 3.3 KV capacitor panel & APFC panel with checking all circuits, tightening of all connections, cleaning of panels by blower, fault finding to maintain the power factor, replacement of spares such as indicating lamps, tripping coil, closing coil, breaker motor, control fuses, P.T fuses, HRC fuses, protection relay, Master trip relay, annunciation (Window), 10A MCB, HT Capacitor, HT APFC relay, 110 V DC auxiliary contactor if necessary etc. complete.
Comprehensive Annual Maintenance (AMC) of 3.3 KV soft starter panel at RWW including cleaning of panel, tightening of all connections, checking of setting of relays, timer, protection system, space heater etc. checking functioning of all components, replacement of spares such as relay ,timer, 16 A MCB, 110 V DC auxiliary contactor, 110 V DC vaccum contactor, 250w/ohm resistance, wires, lugs etc. complete.(excluding replacement of Breaker, FCMA Unit)
Comprehensive Annual Maintenance (AMC) of battery backup and charger in the pump house at RWW consisting of 110 Volts DC batteries battery charger panel including checking battery terminal connections, checking electrolyte in battery, checking control circuits of battery charger, fault finding & its rectification etc. including replacement of spares complete.(excluding replacement of battery)
Comprehensive maintenance of 11/3.3 KV Outdoor type switchyard at RWW including all accessories excluding oil filtration & rewinding of Transformer.
Comprehensive Annual Maintenance (AMC) of LT Switchgear/Starter panel at & RWW & including checking healthiness of D.C. trip system, checking contacts of contactor, VCB, checking relay setting, functional check of all switchgear, tightening of all power & control cable connections, checking insulation resistance, cleaning of panel etc. including replacement of spares such as relay, timer, control contactor, metering equipment‘s, indicating lamps, push buttons etc complete.(excluding replacement of Breaker, FCMA Unit)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_2189341.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
TenderDocument.pdf
Tender Documents • 0.31 MB
ItemSpecification.pdf
Other Document • 0.01 MB
BOQ_2189341.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid