| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | L2₹22.7 L+₹1.9 L (9.31%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹25.8 L+₹5.0 L (24.0%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹27.2 L
EMD Value
₹54,360
Closing Date
13 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF SRINGAR
CWE AF SRINGAR
PROVN OF COMMERCIAL POWER SUPPLY TO MGES AT AF SATION SRINAGAR
2022_MES_572391_1
CWE(AF)SGR/SGR-31/2022-23
Open Tender
Civil Works
Item Rate
180 days
AF SRINAGAR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF SRINAGAR
₹54,360
Yes
30 Mar 2023
31 Dec 2022
15 Feb 2023
31 Dec 2022
13 Feb 2023
30 Jan 2023
Amount
Excavating in trenches in any type of soil ( soft & loose not exc. 1.5 mtr wide and not exc. 1.5 mtr in depth for foundation poles, stays, laying of cables etc for shaft, wells, cesspits, manholes, peir holes, etc not exc. 10 Sqm on plan and getting out, complete all as specified and directed.
Returning, filling in (soil), including spreading, levelling, watering and well ramming in layers not exc. 25cm thick, complete all as specified and directed.
Removal of excavated soils to a distance not exc. 50 metre and depositing where directed at a level notexc 1.5m above the starting point complete all as specified and directed.
Material & Labour for Sand cushioning for underground cable 8cm before laying the cable and 15cm after laying and stretching the cable, complete all as specified and directed.
Material & Labour for Supplying and laying un-reinforced precast concrete cable cover class HV, type - I, flat, size 300 x 180 x 40 mm complete all as specified and directed.
Supply and laying of bricks well burnt sub class B old size) laid flat for cable protection width equal to the length of bricks complete all as specified and directed.
Material & Labour for Steel water tubing light grade of dia 100mm galvanized with all fittings and fixed complete to walls and ceiling or laid in floors/ fixed to poles/ or passing under road crossing, complete all as specified and directed.
Material & Labour for Steel water tubing light grade of dia 80mm galvanized with all fittings and fixed complete to walls and ceiling or laid in floors/ fixed to poles/ or passing under road crossing, complete all as specified and directed.
Material & Labour for Steel water tubing light grade of dia 50mm galvanized with all fittings and fixed complete to walls and ceiling or laid in floors/ fixed to poles/ or passing under road crossing, complete all as specified and directed.
Material & Labour for Steel water tubing light grade of dia 40mm galvanized with all fittings and fixed complete to walls and ceiling or laid in floors/ fixed to poles/ or passing under road crossing, complete all as specified and directed.
Material & Labour for Supply, laying, jointing and testing, HT cable 11000 volts earth grade of cross sectional area 95 Sqmm 3 Core as per IS-7098 (Part-I) 2011, XLPE insulated aluminium conductor heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armoured with an overall PVC sheathing laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required laid under floors, road etc fixed encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles (for junction boxes,etc) for incoming and outgoing cables complete all as specified and as directed. Note : MS clamps with nuts, bolts washer etc shall be measured and paid separately under relevant items.
Material & Labour for Supply, laying, jointing and testing, LT cable 1100 volts grade of cross sectional area 95 Sqmm 3.5 Core as per IS-7098 (Part-I) 2011, XLPE insulated aluminium conductor heavy duty served with an inner sheathing PVC tape, galvanized steel strip or wire armoured with an overall PVC sheathing laid in trenches, fixed along the poles or passed through GI pipe using clamps wherever required laid under floors, road etc fixed concealed in walls encased in GI pipe connecting with suitable size of lugs and cable glands etc, each cable termination is to be made with suitable size of cable glands and aluminium thimbles (for junction boxes, security lights, LT panels etc) for incoming and outgoing cables complete all as specified and directed. Note : MS clamps with nuts, bolts washer etc shall be measured and paid separately under relevant items.
All as per item No 12 but size of 3.5 core 70 sqmm.
All as per item No 12 but size of 3.5 core 50 sqmm.
All as per item No 12 but size of 3.5 core 35 sqmm.
Material & Labour for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed.
Material & Labour for Steel tubular swaged poles type 410 SP-55 (11.0 mtrs long) with 300mmx300mmx6mm mild steel base plate continuously welded to Pole, finial tapper plug, bolts, nuts and screws and making holes as per requirement all as specified including factory painted with two coats black bituminous paint internally throughout and externally for embedded portion and applying one coat of red oxide primer, making 05 Nos strips each 30cm high with super enamel paint with alternate (Black and Yellow/white) colour scheme from ground level/coping upto 1.5M painting with two coats of aluminium paint for the remaining height complete all as specified and directed. Note:- Excavation, earth work and PCC in coping/foundation shall be measured and paid for separately.
Material & Labour for Air break gang operated switch with 12 Nos insulators outdoor type, triple pole, mechanically operated, suitable for vertical installation, single break, provided with locking arrangement, consisting of MS Channel, HT post type insulator copper alloy, high pressure, assembly drop out fuses, operating rod 25mm dia GI pipe, medium grade for operating from 1.2 m above GL complete including drop out fuses conforming to IS rated voltage 11 KV and for current rating 200 Amp all as specified and directed.
Material & Labour for Lightening arrestor (set of three) HT metal oxide surge arrester polymeric type complete with all fittings ,rated voltage 12 KV continuous operating voltage 11 KV, normal discharge current 10 KA, 65 KV dischatge capacity etc complete all specified confirming to IEC-600994-2001 complete all as specified and directed.
Supply,installtion and testing and commissionig step down 11/0.433 KV at (no Load) transformer 3 phase AC, 50 HZ 100 KVA, copper wound, outdoor type with off load manual tap changing arrangement on HT to vary secondary voltage up to + -7.5 % with steps of +- 2.5 % including suitable cable entry box on LT and bushings on HT side to receive 3 core 95 Sqmm XLPE cable on HT side complete in all respects with standard asccessories and fitment confirming to IS 1180 Part-II (latest amendment) dyn-11 connection complete all as specified and directed.sailent features of transformer are as under, (a) Transformer shall be oil immersed, natural self cooled double wound copper winding, corec type, MS radiator cooled tank complete with first fill of transformer as per IS-335 with test certificate on cooling system, temp of oil shall not raised to 55 degree C to ambient and 65 degree c o winding transformer shall be painted with two coat of smoke grey epoxy paint confirming to ISW-632 (b) Rating and diagram plates (c )Earthing terminal 02 Nos (d) Lifting lugs (e) Thermometer pocket (f) Air release bent with plug (g) Winding/oil temp indicator housed in seprate box for control wiring (h) Conservator with oil indicator (j) castors with locking provisions (k) Silica gel breather complete (l) PCC platform as per TD drawings
Material & Labour for Anti climbing devices spikes type fabricated out of MS bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
Material & Labour for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
Material & Labour for Plain cement concrete 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
Material & Labour for PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate as in coping benching and the like including weathering, slightly rounded or chamfered angles as directed including necessary form work and finishing all exposed surfaces complete all as specified and directed.
Material and labour for earthing complete with galavanised steel earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below gound level with top edge of the earth plate not less than 1.5 m below normal gound level connected to galvanised steel earth wire of size 4.0 mm by means of bolts, nuts, check nuts and washers of galavanised iron/steel and conneted to main control board as directed and including proivison of concrete pit in PCC (1:2:4) type B1 pre cost RCC earth pit cover reinforced with 8 mm dia TMT bars @ 150mmc/c of size 54cmx54cmx8cm with two handle for lifting made out of 8mm dia MS bar, provision of funnel, wire mesh, 20mm bore galavanised steel tubing (med grade) for watering. Charcoal 250 Kg and salt 200 Kg in alternate layers, 40mm bore galavanised steel tubing light grade for protection of earth lead connection including necessary excavation and earth work and testing complete all as shown on electrical plate No 3 of SSR Part-I. Note : Earth strip and protection pipe upto 7.5m is included in the unit rate of this item. Contractor shall quote his rate accordingly.
Material and labour for earthing complete with galavanised steel earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below gound level with top edge of the earth plate not less than 1.5 m below normal gound level connected to galvanised steel earth strip of size 32x6 mm by means of bolts, nuts, check nuts and washers of galavanised iron/steel and conneted to main control board as directed and including proivison of concrete pit in PCC (1:2:4) type B1 pre cost RCC earth pit cover reinforced with 8 mm dia TMT bars @ 150mmc/c of size 54cmx54cmx8cm with two handle for lifting made out of 8mm dia MS bar, provision of funnel, wire mesh, 20mm bore galavanised steel tubing (med grade) for watering. Charcoal 250 Kg and salt 200 Kg in alternate layers, 40mm bore galavanised steel tubing light grade for protection of earth lead connection including necessary excavation and earth work and testing complete all as shown on electrical plate No 3 of SSR Part-I. Note : Earth strip and protection pipe upto 7.5m is included in the unit rate of this item. Contractor shall quote his rate accordingly.
Supply and fixing of GI Earthing strip of size 32X 6 mm complete all as specified and directed.
Material & Labour for Plain mild steel wire, galvanised class 3, in chain link fencing including straining and fixing to steel posts and/or to straining bolts, including securing with and provision of galvanised iron tying wire, galvanised iron staples or steel pins, detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes. omplete all as specified and directed.
Material and labour for platform in brick masonry with surface finishing using extra cement for the installation of transformer of size 3000x2500x1200 mm complete with chain link fencing and gate all as shown in Drg No. CEPZ/TD/350/08 sheet 1/2 and as specified and directed by Engr-in-Charge.
Material and labour for cutting of existing road surfaces up 100 mm deep & 300 mm wide and making good disturbed portion with 100mm thick plain cement concrete 1:2:4 type B-1 (using 40mm graded crushed stone aggregate) complete all as specified and directed by Engineer-in-Charge.
Material and labour for HT cable path indicator made with 3 mm thick MS sheet 300mmx300mm welded with 1.5 mtr height angle iron of size 45mm x 45mm x 5mm with PCC work provided at a distance minimum 100 mtrs and every joint and turning of cable. The cable path indicator should be painted in brown colour and marked 11000 Volts in white paint fixed on MS angle iron all as specified and directed.
(vi) Digital power factor meter 440 volts 5 amps with built in transducer flush Mfd 96 sqmm size conf to cat part No AE-66303 of make AE or equivalent of make legrand/Rishap. (vii) Indicator lamp LED type 230 volts for Gen/Mian supply On/Off indication and diffrent relay position etc all as required and recommended by manufacture. (viii) bakelite fuse base carrier with HRC fuses 63 amps 415 volts suitable for and including knife type HBC fuse link of make standard /L&T Havells 12 Nos. (ix) DC operated relay as required for remote operation fault indicators and auto switching OFF in case of fault in DG Sets. (x) on Load chanage over switch 4 pole 415 volts 50 HZ 40 A in open execution for manual over of supply in case of AMF panel failure. All accessories prewired with suitable size PVC insulated copper conductor cable of appropriate size including connections from DG set all as required at site. Note : The AMF Panel shall be integrated with respective LT distribution panal and all electrical connections done using copper bus bars PVC sleeved of appropriate rating but not lessthan as of LT panel.
(vi) Digital power factor meter 440 volts 5 amps with built in transducer flush Mfd 96 sqmm size conf to cat part No AE-66303 of make AE or equivalent of make legrand/Rishap. (vii) indicator lamp LED type 230 volts for Gen/Mian supply On/Off indication and diffrent relay position etc all as required and recommended by manufacture. (viii) bakelite fuse base carrier with HRC fuses 25 amps 415 volts suitable for and including knife type HBC fuse link of make standard /L&T Havells 12 Nos. (ix) DC operated relay as required for remote operation fault indicators and auto switching OFF in case of fault in DG Sets. (x) on Load chanage over switch 4 pole 415 volts 50 HZ 25 A in open execution for manual over of supply in case of AMF panel failure. All accessories prewired with suitable size PVC insulated copper conductor cable of appropriate size including connections from DG set all as required at site. Note : The AMF Panel shall be integrated with respective LT distribution panal and all electrical connections done using copper bus bars PVC sleeved of appropriate rating but not lessthan as of LT panel.
M/S NEW FAROOQ TRADERS
M/S M.A. Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .