Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | ₹1.3 Cr | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹1.3 Cr+₹1.3 L (0.96%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹1.3 Cr+₹1.3 L (0.96%) | L2 | Rejected-Finance BEING NOT LOWEST TENDER |
| 3 | L3₹1.5 Cr+₹14.6 L (11.0%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | ₹1.5 Cr+₹14.6 L (11.0%) | L3 | Rejected-Finance BEING NOT LOWEST TENDER |
| 4 | L4₹1.5 Cr+₹16.2 L (12.2%)Rejected-Finance | ₹1.5 Cr+₹16.2 L (12.2%) | L4 | Rejected-Finance BEING NOT LOWEST TENDER |
| 5 | Rejected-Technical | - | - | Rejected-Technical NOT ENLISTED IN PARTICULAR CAT C (I) |
Tender Value
₹1.5 Cr
EMD Value
₹2.3 L
Closing Date
10 Sept 2021, 6:00 pmClosed
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR/ MAINT OF ACs GEYSERS, SOLAR WATER HEATERS, INTERNAL ELECTRIFICATION, FITTING, FIXTURES, MAIN DBs, BLDG EARTHING AND OTHER MISC E/M WORKS AT AF STN SULUR
2021_MES_468224_1
8438/E8
Open Tender
Miscellaneous Works
Item Rate
334 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Yes
GE AF SULUR
₹2.3 L
Yes
11 Oct 2021
14 Aug 2021
11 Sept 2021
14 Aug 2021
10 Sept 2021
4 Sept 2021
14 Aug 2021 - 3 Sept 2021
Amount
SCHEDULE A BOQ
Dismantling existing damaged ducts and Supply, assembly and erection of 24 gauge GI sheet with C & SS rectangular/square duct made out of 'L' shaped hollow profile, duly factory boxed, incl all accessories such as Corner, Cleat, Carriage bolt, hanging rod, Gasket and appropriate sealant on longitudinal joints etc complete all as specified and as directed.
M&L in repairs duct insulation with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation suitable for 40 mm as specified and including the following:- (a)Cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b)Applying rubber based adhesive CPRX compound. (c) Sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) Securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.
S&F in replacement of grills/diffusers of size 630X630 mm for supply air duct made out of CRCA sheet 1.2mm thick, with perforation duly powder coated etc adjustable type(with flow regulating arrangement) all as directed.Make : Microflow ,3C Air Equipments, Deepak cooling control.
Supply and fix in replacement of Galvanised steel, volume control damper/parallel Blade Dampers for rough air system balance with closer control at the individual grills or diffusers for supply air complete all as specified and as directed. Make : Microflow, 3C Air Equipments, Deepak cooling control.
M&L Providing insulation on and around suction and discharge copper tube of size 3/8"/ 5/8" with 6mm thick flexible thermocol heat resistance duly wrapped with sticking tape and finally covered with flexible PVC conduit of 50mm bore complete including taking down existing damaged one all as specified and as directed.
Supply and fix in repair Blower fan motor 3 phase 750 W suitable for AC plant 1 x 12 TR capacity at OTF of existing make/ brand of defective components or any reputed suitable make as approved by the Engineer-in-Charge.
Supply and fix in repair AHU Blower motor with blower set of existing make suitable for the 3X16.5 TR precision type AC plant at Transmitter/ Opera-I complete all as specified and as directed.
Taking down old unserviceable scroll type compressor of capacity 5 TR including supply and replacement of same capacity of compressor of Make Emerson Climate Technologies or equivalent make for AC plant at location : T-51 (Avonics Lab)/ Opera - I Note:- (a) Compressor shall be purchased from manufacturer/ authorised dealer of the manufacturer. Compressor shall be in sealed condition and shall bear warranty for 12 months from the date of purchase.
Servicing of chiller pump 5HP 3 phase 415 Volt of Make:M/s Kirloskar including replacement of unserviceable bearing bush with testing and commissioning complete all as specified and as directed.
Supply and replacement of unserviceable PVC compressed air pipe of 15mm dia suitable for 150 PSI complete all as specified and as directed. Make : Presto Plast/ Modi/ Avon Plast
Supply and fix in repair microprocessor Controller suitable for 15TR AC plant at TRCL complete all as specified and as directed.
Supply and fix in replacement of unserviceable CTV Coil incoming 230Volt outgoing 12V/24V of existing make/ brand of defective components or any reputed suitable make as approved by the Engineer-in-Charge.
Supply and fix in replacement of contactor 3 Phase, 32 A, 415 Volt suitable for AC plant of capacity 1 x 15 TR at CRRW complete all as specified and as directed. Make : Siemens, Schneider, L&T
Taking down old unserviceable outdoor condenser from existing unit and Supply and fix new outdoor condenser of same Model suitable for the AC plant 1 x 8.75 TR at T-51 (Avonics Lab)complete all as specified and as directed.
Supply and fix in repair condenser fan motor of outdoor unit of AC plant 1 x 12 TR capacity at Opera-II complete all as specified and as directed.
M&L for complete overhauling of air compressor 20 HP of Make: M/s Ingersoll including replacement of valve assembly LP-2 Nos, valve assembly HP - 1 No, Piston rings LP-2 sets, Piston Rings HP - 1 set, Air filter element - 2 No, Gasket set - 1 set and compressor oil - 5 ltr etc including testing complete all as specified and as directed by Engineer in Charge. Note :- Repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer.
Supply only Refrigerant gas R – 22 as and when required for AC plants of following capacity complete all as specified and as directed:-
(a) 3 × 30 TR Rubber store of Voltas make
(b) 2 x 7.5 TR for TRCL of Voltas make
Supply and fix in replacement of contactor 3 Phase 415 Volt suitable for AC plant of capacity 3 x 16.5 TR at Opera-I complete all as specified and as directed.
S&F water pressure cut out 230 volt including taking down existing one complete all as specified and as directed. Make Indfoss or equivalent.
Supply and fix in repair Blower fan motor suitable for AC plant 1 x 8.75 TR at T-51 of existing make/ brand of defective components or any reputed suitable make as approved by the Engineer-in-Charge.
S&F in repair strainer of package type ac plant of capacity 1 x 12TR with ISI mark complete all as specified and as directed.
M&L taking down AHU Motor of capacity 10HP from location for servicing including replacement of bearing,bush and rewinding and refixing the same complete all as specified and as directed.
Supply and fix in replacement of contactor 3 Phase, 32 A, 415 Volt suitable for AC plant of capacity 1 x 12 TR at AVRO complete all as specified and as directed. Make : Siemens, Schneider, L&T
S&F in repairs Oil pressure cut out of existing make/ brand of defective components or any reputed suitable make as approved by the Engineer-in-Charge.
M&L for Compressor Oil freeze -90LTR complete all as specified and as directed. Make:Castrol, Shell , Servo
Supply and fix in repair condenser fan motor of outdoor unit of AC plant 1 x 15 TR capacity at CRRW/ SEW of existing make/ brand of defective components or any reputed suitable make as approved by the Engineer-in-Charge.
Comprehensive maintenance of Air compressor 20 HP of Make : M/s Ingersoll, 3 phase including attending day to day complaints, checking of airflow line, oil change, pressure switch setting, setting of air filters, checking functioning of valves, checking of guage by the original manufacturer complete all as specified and directed. Location- LCA Hanger No. I, II & III -03 Nos. Note :- (a) The contractor shall make AMC contract for 11 months with the authorised service agency of any make /manufacturer of equipments installed in above said three plants and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The authorised service agency must be attended as and when called for urgent nature of repair of the equipments. (c) Any minor items to be replaced is included in the item quoted rate. (d) Payment shall be made thrice for the period of 11 months proportionately for comprehensive maintenance.Please note that no payment will be enhanced if the contract period has extended and payment is not applicable for extended period.
Supply and fix in replacement of contactor 3 Phase 415 Volt suitable for AC plant of capacity 3X45TR at Rotable Div and 2 x 7.5 TR at TRCL complete all as specified and as directed. Make-Siemens, ABB, Schneider, L&T.
Supply and fix in replacement of Big end Bearing of compressor of Model : 5H - 40 Voltas make for 3 × 30 TR plant complete all as specified and as directed.
Supply and fix in replacement of Small end Bearing of compressor of Model : 5H - 40 Voltas make for 3 × 30 TR plant complete all as specified and as directed.
Supply and fix in replacement of unserviceable outdoor condensor fan motor of capacity single phase 0.5HP, 900 Rpm,suitable for AC plant at TRCL complete all as specified and as directed.
Supply and fix in replacement of Oil pump assembly with gear of compressor of Voltas make for capacity 3 × 30 TR Rubber store complete all as specified and as directed.
Supply and fix in replacement of Piston with rings (Oil ring / pressure ring) of compressor of Model : 5H - 40 voltas make for 3 × 30 TR plant complete all as specified and as directed.
Supply and fix in repair condenser fan motor of outdoor unit of AC plant 3 x 16.5 TR capacity at transmitter complete all as specified and as directed.
Supply and fix in repair condenser fan motor of outdoor unit of AC plant 2 x 7.5 TR capacity at TRCL complete all as specified and as directed.
Supply only Refrigerant gas R – 407 C as and when required for AC plants of following capacity complete all as specified and as directed:-
(a) 1 x 8.75 TR for T/51 Plant
(b) 3 x 16.50 TR for Transmitter plant
(c) 1 x 12 TR for Avro plant
(d) 1 x 12 TR for signal section and OTF
(e) 1 x 15 TR for CRRW,SEW
(f) 3 x 45 TR for Rotable Division (P-26)
(g) 1 x 16 TR for Clean Room (P-15)
S&F in repair AHU fan motor including blower 230 volt,complete all as specified and as directed. Make : GEA or equivalent.
Supply and fix in replacement of condensor contactor 3 Phase 415 Volt suitable for AC plant of capacity 3 x 30 TR complete all as specified and as directed. Make : Siemens, L&T, Schneider
Comprehensive maintenance of 25 KVA static frequency converter with input supply of 3 phase 415 V, 50 Hz with output of 3 ph 4 wire 115 AC /200 V AC 400 HZ Make- Power one Micro systems including attending day to day complaints, Isolating converter from system, opening up, examining the accessories parts, cleaning , soldering as required and testing and connecting back with the systems as directed by the Engineer-in-charge. Location - LCA Hanger No-I,II & III-09 Nos. Note :- (a) The contractor shall make AMC contract for 11 months with the original manufacturer of the equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The authorised service agency must be attended as and when called for urgent nature of repair of the equipments. (c) Any minor items to be replaced is included in the item quoted rate. (d) Payment shall be made thrice for the period of 11 months proportionately for comprehensive maintenance.Please note that no payment will be enhanced if the contract period has extended and payment is not applicable for extended period.
Comprehensive maintenance of Air compressor 10 HP of Make : Ingersoll 3 phase including attending day to day complaints, checking of airflow line, oil change, pressure switch setting, setting of air filters, checking functioning of valves, checking of guage by the original manufacturer complete all as specified and directed. Location- LCA Hanger No.I,II& III -06 Nos. Note :- (a) The contractor shall make AMC contract with the authorised service agency of any make /manufacture of equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The authorised service agency must be attended as and when called for urgent nature of repair of the equipments. (c) Any minor items to be replaced is included in the item quoted rate. (d) Payment shall be made thrice for the period of 11 months proportionately for comprehensive maintenance.Please note that no payment will be enhanced if the contract period has extended and payment is not applicable for extended period.
Checking & rectification of defective control panel wiring of any capacity AC plant including replacement of all required minor spare parts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in repair AHU Blower motor with blower set of MAKE suitable for the 1 x 12 TR precision type AC plant at AVRO/ Opera-II complete all as specified and as directed.
Supply and fix in replacement of compressor contactor 3 Phase 415 Volt suitable for AC plant of capacity 3 x 30 TR,complete all as specified and as directed.Make : Siemens, L&T, Schneider
Taking down unserviceable MCCB, supply and fixing MCCB 125 amps 25 KA 4 pole 415Volts including connection using suitable size of aluminium lugs complete all as specified and as directed. Make : L&T, ABB, Schneider
Comprehensive maintenance of Air compressor 10 HP of Make : ELGI 3 phase including attending day to day complaints, checking of airflow line, oil change, pressure switch setting, setting of air filters, checking functioning of valves, checking of guage by the original manufacturer complete all as specified and directed. Location- SES Bldg. Note :- (a) The contractor shall make AMC contract with the authorised service agency of any make /manufacture of equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The authorised service agency must be attended as and when called for urgent nature of repair of the equipments. (c) Any minor items to be replaced is included in the item quoted rate. (d) Payment shall be made thrice for the period of 11 months proportionately for comprehensive maintenance.Please note that no payment will be enhanced if the contract period has extended and payment is not applicable for extended period.
M&L for Servicing of Air curtains unit, of any type capacity and length, single phase AC, 230 Volts as in preventive maintenance alongwith blower assembly filter and other components including checking electrical connections all as specified and as directed.
M&L in repairs blower motor assembly of Air curtain unit of any type capacity and length, single phase AC, 230 Volts as including electrical connections all as specified and as directed.
Supply and fix in repair AHU Blower motor with blower set of as per existing/ suitable make for the 1 x 15 TR precision type AC plant all as specified and as directed.
M & L in repairs contactor 4 pole 63 Amps all as specified and as directed.Make: L&T, ABB, Schneider
Comprehensive maintenance of DC power supply (rectifier) 28 Volts DC out put 12 KW with input supply of 3 phase 415 V, 50 Hz Make- Power one Micro systems including attending day to day complaints, Isolating converter from system, opening up, examining the accessories parts, cleaning , soldering as required and testing and connecting back with the systems as directed by the Engineer-in-charge. Location - LCA Hanger No-I, II & III - 09 Nos. Note :- (a) The contractor shall make AMC contract for 11 months with the original manufacturer of the equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The authorised service agency must be attended as and when called for urgent nature of repair of the equipments. (c) Any minor items to be replaced is included in the item quoted rate. (d) Payment shall be made thrice for the period of 11 months proportionately for comprehensive maintenance.Please note that no payment will be enhanced if the contract period has extended and payment is not applicable for extended period.
Comprehensive maintenance of Air compressor 3 HP of Make : ELGI 3 phase including attending day to day complaints, checking of airflow line, oil change, pressure switch setting, setting of air filters, checking functioning of valves, checking of guage by the original manufacturer complete all as specified and directed. Location- T-68 Hanger Note :- (a) The contractor shall make AMC contract with the authorised service agency of any make /manufacture of equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The authorised service agency must be attended as and when called for urgent nature of repair of the equipments. (c) Any minor items to be replaced is included in the item quoted rate. d) Payment shall be made thrice for the period of 11 months proportionately for comprehensive maintenance.Please note that no payment will be enhanced if the contract period has extended and payment is not applicable for extended period.
Comprehensive maintenance of 50KVA through online UPS system with SMF batteries, with input supply of 3 phase 415V, 50HZ of Make Aplab including attending day to day complaints, isolating UPS from system, Opening up, examining the accessories parts, cleaning, soldering as required and testing and connecting back with the system as directed by the Engineer -in-charge. Location - IT section.
Note For item No 62 :- (a) The contractor shall make AMC contract for 11 months with the original manufacturer of the equipment and the repairs/maintenance shall be carriedout through the original manufacturers only. (b) Cost of any minor items to be replaced is included in the item quoted rate. (c) Payment shall be made thrice for the period of 11 months proportionately, for comprehensive maintenance.Please note that no payment will be enhanced if the contract period has extended and payment is not applicable for extended period. (d) Any other spare parts which have not covered in the relevant items but are required to make in functional condition are deemed to be included in the quoted unit rate. (e) Cost of labour element towards removing of unserviceable spare parts and re-fixing of serviceable spare parts shall be deemed to be included in quoted rate. Supply only spare parts shall be measured and paid separately.
Supply only Cooling fan suitable for 25KVA to 50KVA through online UPS of Make - Aplab all as specified and directed.
Supply only DC Capacitor suitable for 25KVA to 50KVA through online UPS of Make - Aplab all as specified and directed.
Supply and Fix Sealed Maintenance Free (SMF) battery of capacity 12 V, 26 AH, suitable for existing 3 phase online UPS as required at location including initial charging complete with inbuilt charger including electrolyte/ distilled water etc including taking down of old battery and shifting to MES store yard for deposit all as directed by engineer in charge complete all as specified. Make of battery : Exide of model No. EP 65 or equivalent in Amar raja (Power Zone)/ Amaron Note :- The contractor shall submit full replacement warranty certificate for minimum 02 years from the date of installation.
Comprehensive maintenance of Air compressor 2 HP of Make : ESKAY 3 phase including attending day to day complaints, checking of airflow line, oil change, pressure switch setting, setting of air filters, checking functioning of valves, checking of guage by the original manufacturer complete all as specified and directed. Location- FOL Lab, 5 BRD Note :- (a) The contractor shall make AMC contract for 11 months with the authorised service agency of any make /manufacture of equipments and the repairs/ maintenance shall be carried out through the Authorised service agency only as per instructions recommended by the original manufacturer. (b) The authorised service agency must be attended as and when called for urgent nature of repair of the equipments. (c) Any minor items to be replaced is included in the item quoted rate. (d) Payment shall be made thrice for the period of 11 months proportionately for comprehensive maintenance.Please note that no payment will be enhanced if the contract period has extended and payment is not applicable for extended period.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5m deep in hard/dense soil and getting out for taking down/laying of pipes complete all as specified and directed.
Returning, refilling including spreading levelling watering and well ramming in layers not exceeding 25cms thick in hard/dense soil complete all as specified and directed.
Removing excavated materials not exceeding 50m distance and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified and directed.
Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and directed. Note :- In case sufficient sand not obtained from excavation, the required additional qty obtain from out side MD land as directed by the Engineer-in-Charge. The rate is deemed to be included the above provision.
M&L Fly ash bricks using modular bricks as in cable protection cover including taking down existing bricks of any size complete all as specified and directed.
S&F XLPE insulated,screened, PVC Bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 70 Sqmm 3.5 core, laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets, including taking down existing cable complete all as specified and directed. Make : KEI/ Polycab/ Havells
Cutting existing road/PCC/Drain for laying of DI/GI or any type of pipe including necessary earth work, excavation exc 600mm depth but not exc 1mtr depth, wide 800mm including making existing surface with PCC 1:2:4 type B1 using 20mm graded stone aggregate with a thickness of concrete is 150mm complete all as specified and directed.
Note for item No 74 :- The tenderer shall take into consideration for following points while quoting his rate for this item and the unit rate is deemed be included for :-
(i) Earth work excavation in any type of soil
(ii) Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed.
(iii) Removing excavated material to out side MD land
(iv) Laying of any type/any bore of pipe in trenches including taking down any description. Supply of pipe will be measured and paid separately
(v) 150 mm thick PCC 1:2:4 type B1 as in any type of road
Supply only 50 mm bore of pipe high density polyethylene pipes (HDPE) of pressure rating 6 kgf/ sqcm laid in trenches for cable protection passing under road/ floor or for fixing to poles complete all as specified and directed. Note : The unit rate is included for supply only and cutting existing road, excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately.
M&L XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium conductor 1100Volts grade cross sectional area 50 sq mm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed. Make : Havells/ KEI/ Polycab
Supply only GI pipe 50 mm bore medium grade for cable protection complete all as specified and as dierced by Engr-in-Charge. Make : Tata, Jindal, Surya Prakash Note : The unit rate is included for supply only and cutting existing road, excavation, Laying of any type/any bore of pipe in trenches including taking down any description and 150 mm thick PCC 1:2:4 type B1 as in road will be measured and paid separately.
M&L in repairs Cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 50 sqmm to 70 sqmm. Make : Reychems, Densons, M-Seal
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms either from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with 01 No polycarbonate IP 65, 9W LED translucent bulk head luminaire, 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with 01 No of 16A 3P IP 65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 phase and neutral 400 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
Inspection,checking adjustments and minor repairs of storage water heater 25/35/50 ltr capacity of any type any make vertical/ horizontal type which includes the following complete all as specified and directed:- (a) Inspection, taking out of drain plug & dewatering and refix the same complete all as directed . (b) Checking water tightness of storage tank . (c) Checking stop cocks with outlet/inlet pipe of geysers, pressure reducing valves etc to ensure free movement of water and easy functioning of parts. (d) Inspecting over flow vent pipe connections to ensure water-tightness and proper flow. (e) Checking and correct earth continuity of electrical items. (f) Checking functioning of heating element and correct setting adjustment of thermostat upto 55º C. (g) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (h) Replacement of defective spares shall be measured and paid under relevant items mentioned below separately as supply and fix.
Note for item No 87 :-
The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced, before commencement of work.
The entire job will be carried out in entire area of Air Force stn Sulur and necessary documents showing qtr No, bldg No supported with user signature shall be prepared as per format given by Engr-in-charge and will be deposited to concerned JE (E/M) within 24 hrs.
All types of T&P, PVC insulation tape, minor nuts, bolts, washers etc required for maintaining the services shall be provided by contractor without any cost to the department.
S&F Heating element, thread type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including taking down old one including washer/packing suitably complete all as specified and as directed. Make:- Theeta/Swarna/ ISI Mark
S&F in replacement pressure relieving valve CP brass confirming to relevant IS with washer suitable for 15mm bore GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed. Make : Leader / Theta / ISI Mark
S&F in replacement thermostat switch range of 30-80 degree suitable for geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed. Make : Theeta/Swarna/ Elcon.
S&F Glass wool for insulator of Geysers any capacity and any make taking down existing one complete all as directed by the Engr-in-Charge.
S&F Heating element, tikona type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including taking down old one including washer/packing suitably after taking down existing one complete all as specified and as directed. Make :Theeta/Swarna/ ISI Mark
S&F PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 450 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe taking down existing one complete all as specified and as directed.
S&F in repairs Indicator lamp for geyser 25/50 ltr capacity of colour green & red complete all as specified and as directed. Make : Usha / Bajaj/ Crompton
S&F Copper inner tank of minimum 20 gauge sheet rated pressure not less than 7kg/sqcm suitable for 25 ltrs capacity geysers (wt not less than 3.75 kg) as per sample including taking down existing one complete all as specified and as directed.
S&F in replacement brass non return valves, screwed down, high pressure, screwed both ends for 15mm bore iron pipe or for union, ISI marked, complete all as specified and as directed. Make : Seiko, Leader, Zoloto
Cutting and screwing existing steel water tubing 15/20/25 mm bore for addition /alteration required for connections to geysers etc taking down existing one complete all as specified and directed.
S&F in replacement bottom cover of MS sheet 20 gauge suitable for 25 ltrs capacity geysers and providing a coat of red oxide primer to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
S&F in repairs provision brazing of inner copper tank Geysers using quality of copper electrode blow lamp welding process brazing length n.exc 10 cm all as specified and directed at site the Engr-in-Charge.
S&F in replacement heating element, cup (square) type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including taking down old one including washer/packing suitable complete all as specified and as directed. Make : Theeta/Swarna/ ISI Mark
M&L in replacement PVC connection for hot/ cold water made of double layer nylon braided and fabric at a pressure of 6kg/sq cm at both ends, 600 mm long, heavy duty with CP brass adopters, washers, suitable for 15 mm bore pipe complete all as specified and as directed.
Taking down carefully storage water heater (geyser) 25 ltr capacity of any type, any make from the location by removing the electric & water supply connection and shifted to work shop/MES store yard for repair and re-installation at any location including S&F in repair of heavy duty pin type fastener 4" long and making necessary inlet/outlet electric & water supply connection from existing source to geyser complete all as specified and as directed. Note :- The quoted rate is deemed to include for adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness also.
Description all as per Sl item No. 106 here-in-above but 35/50 Ltr capacity.
S&F Heating element, tikona type, 2.00 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including taking down old one including provision of suitable washer/packing complete all as specified and as directed. Make : Theeta/Swarna/ ISI Mark
M&L for painting of outer surface of 25 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed.
S&F in replacement 25 Ltr capacity in any make, indoor assembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed.
S&F Copper inner tank of minimum 20 gauge sheet rated pressure not less than 7 Kg/sqcm suitable for 35/50 ltrs capacity geysers (wt not less than 5.25 kg) as per sample including taking down existing one complete all as specified and as directed.
S&F in replacement bottom cover of MS sheet 20 gauge suitable for 35/50 ltrs capacity geysers and providing a coat of red oxide primer to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
M&L in repairs Bottom cover in two pieces for covering the base plate, heating element, thermostat made out of MS sheet 22 gauge as per existing size and shape duly painted with two coat of white synthetic enamel paint over one coat of red oxide primer including preparation of surfaces complete all as specified and as directed.
S&F Heating element, thread type, 2.00 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any capacity and any make including taking down old one inlcuding washer/packing suitable taking down existing one complete all as specified and as directed. Make : Theeta/Swarna/ ISI Mark
S&F in replacement 35/50 Ltr capacity in any make indoor assembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed.
Dismantling carefully solar storage water heating system of any capacity, any type for following works with testing and refixing the same in original position including all water/ electric connection to entire satisfaction of Engineer-in-charge after carry out servicing as under :- (a) Inspection, opening, of all parts, descaling, washing of inner tank with chemical solution and cleaning of outer cover storage tank. (b) Checking water tightness of storage tank after cleaning. (c) Checking and correcting earth continuity of electrical items. (d) Adjustment of reducing valves, checking of dead weight type high pressure release valve and visual check of fusible plug for its intactness. (e) Replacement of damaged solar cells (solar cell shall be measured and paid separately under relevant item) (f) Necessary T&P such as ladder,helper shall be contractor responsibiliy.
M&L for painting of outer surface of 50 ltrs storage type water geysers after cleaning of dust & other organic/inorganic materials if any and applying one coat of synthetic enamel white paint by spray painting and writing MES No on the geyser complete all as specified and as directed.
S&F in replacement thermostat switch suitable for solar water heater of any make and size complete all as specified and as directed. Make : USHA / Bajaj / Recold / Theta
S&F in replacement heating element 3 KW, 230 volt ISI marked suitable for solar geyser tank of any make, any size complete all as specified and as directed. Make : Theta / Daspas / Recold / Bajaj.
S&F Gasket set for solar water heater panel suitable for 100Ltr capacity complete all as specified and as directed.
Supply and fix in replacement rotational moulded 300 litres capacity double layered HDPE water storage tanks cylindtrical vertical with closed top as per IS 12701-1996 hoisted and fixed in position, including provn of inlet pipe, over flow pipe, washout pipe etc complete all as specified in SSR Part I and as directed.
S&F in replacement bib taps, cast copper alloy, with crutch or butterfly handle, chromium plated, fancy type, screwed down, screwed for 15mm bore iron pipe, ISI marked, complete all as specified and as directed. Make: Seiko, Leader, Jaguar
Supply only solar cells to replace the damaged cells in the solar panel for solar water heater 100 Ltr capacity complete all as specified and as directed.
Supply and fix in replacement of solar tube as per exisiting type complete all as specified and as directed.
S & F in replacement industrial type metal clad plug top & socket single pole and a natural link earth enclosure with MCB SP 20 Amp complete all as specified and as directed.
S&F in repairs Stop valves, 15 mm Bore of pipe in mm fancy type, chromium plated , high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F ball brass valve high pressure with polythene float and fly nut complete screwed for iron pipe 25mm bore in repairs complete all as specified and as directed.
S&F PVC water storage tank cover suitable for 250/ 300 ltrs capacity tank with locking arrangement complete including taking down of existing one all as specified and directed
Supply and fix in repairs solar panel glass suitable for 100 ltrs capacity solar water heater with gasket complete all as specified and as directed.
Supply and Fix in replacement of solar water heater tank 100 ltr capacity tank having 1.60 mm thickness low carbon steel with porcelain coating, outer tank should be 0.4 mm thickness stainless steel 202 grade Non Magenetic grade, insulation is PUF 50mm including provn for suitable solar tubes complete all as specified and directed.
Supply and fixing in repairs MCB SPN 32/40 amps 240 V complete all as specified and as directed.
S&F in repairs 3 layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16) UV stablized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to walls/ceilings or floors of 32 mm (outer dia of pipe) complete all as specified and as directed. Make : Supreme, KPT, Prince
S&F in repairs 3 layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16) UV stablized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to walls/ceilings or floors of 25 mm (outer dia of pipe) complete all as specified and as directed. Make : Supreme, KPT, Prince
S&F ball brass valve high pressure with polythene float and fly nut complete screwed for iron pipe 20mm bore in repairs complete all as specified and as directed.
Cleaning of service tanks of 250/ 300 ltrs capacity on roof top of bldgs upto five storrey after disconnection from inlet and outlet pipe, removing of float valve of service tank and keep aside safely for reuse drain out water through drain plug, cleaning thoroughly to remove all scales and dirt by brushing internal surface, cleaning properly inside with soda wash, flushing out with fresh water, re-positioning of tank at same place, re-connecting inlet and outlet pipes, closing of drain plug, re-installation of float valve duly cleaned, writing/ labelling the record of cleaning carried out with white bold letter such as "TANK CLEANED ON"--------- (month and year), including removing creepers, vegitation and roots of plants, trees branches on or surrounding of service tank complete all as directed. Note:-(i) Unit rate quoted is deemed to be included for testing of water supply in tank both inlet and outlet flow during next supply hours early in the morning or late in evening. (ii) Contractor shall maintain a pucca bound register for cleaning carried out with date and obtain users signature and remarks if any and this register to be submitted alongwith RAR. (iii) Contractor is liable to rectify any damages to the external finishes of the bldg occured during the cleaning process, i.e. scrubbing and touch up with external paints as existing specifications. Unit rate quoted is deemed too be included the cost of the same. (iv) All sort of petty T&P items such as ladder, safety equipment, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept.
M&L for Staging / frame work for Solar water tanks using standard mild steel sections like angle iron / MS pipe / flat iron / sheets etc using steel of Fe 410-W (Gde E-250) quality - A including necessary welding suitable to keep 300 ltrs PVC water tank in repairs complete all as specified and directed by Engr in charge.
Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide zinc chrome primer complete all as specified and directed.
Repair, maintenance and making the continuity of supply after rectifying the defects of the electrical items such as light point, fan point, call bell point, socket point 5A/15A, switches, sockets, regulator, lamp holder, brackets, bell, buzzer, push button, batten, ceiling rose, pendent, any type of MCB's, DB's any type of light fixtures, any type of lamp, ceiling fan, exhuast fan, geyser, capacitor, replacement of fuse wires and all elcectrical accessories in day to day/door to door maintenance including reconnection with S&F small pieces of elctrical cable of size upto 10 sqmm single core and length not exceeding 0.50m complete all as specified and as directed. Note : Any major items required to be repaired/replaced will be measured and paid under relevant items as supply only.Cost of labour for replacement will be deemed to include in the unit quoted rate.
Note for item No 138 :- (a) The above job shall be carried out by a trained electrician having ITI in electrical, documentary proof of the education of tradesman shall be produced before commencement of work.
(b) All bldg light complaints including service connection, submain & internal electric supply for entire domestic and Tech area of AF Stn sulur shall be attended.
(c) Record of complaints/complaint slip showing qtr No, bldgs No, nature of job supported with users signature shall be prepared as per format directed by Engr-in-charge & will be deposited to concerned JE E/M within 24 hrs.
(d) All sort of petty T&P items such as PVC insulation table, ladder, galvanised screws, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept.
Supply only switch piano flush type 5 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
Supply only switch piano flush type 5 Amps 240 volts single pole two way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
All as per item No 143 here-in-before but 15 Amp Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
Supply only shuttered socket outlet 3 pin 5 amps, flush type
Supply only shuttered socket outlet 2 in 1, 5 pin, 5 and15 amps
Supply only switch socket combination out let 3 pin 5 amps, flush type.
Supply only switch socket combination out let 5 in 1, 5 pin 5 and 15 amps, flush type.
Supply only for Ceiling rose 3 plates flush type 6 Amps,250 volts AC ISI marked,
Supply only lamp holder, insulated body, cord grip pattern SP 230 volt, complete all as specified and as directed.
Supply only electronic fan regulator 230 volts, step type socket type, hum free 100/240 watt. Make : Havells / Schnieder/ crabtree
Supply only PVC gang box 1 way 05 amp . Make. Cona/SSK/Anchor
Supply only Electronic ballast for 36/40 W flourecent tube light fittngs, 230V, Make : Sumo Slim EBE(Slim) 136 TLD 240 of Philips or equivalent of Bajaj/Crompton Greaves (CG)
Supply only starter for 40W flourecent tube light fittngs 1x40 /2x40 watts 230V. Make : Philips/ Bajaj/ CG
Supply only single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity conforming to IS 8828 of 1996 all as specified (Make/Model : Lexic MCB of MDS Legrand Cat No :408587 to 408595 / Siemens/ Schnieder.
Supply only metal clad switch socket single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A concealed in walls. Make : Cat Pt No 607841 of Legrand or equivalent of Schnieder (Multi -9) or Siemens/L&T (Hegar).
Supply only electric bell, AC 230 volt, single pole Ding Dong type complete all as specified and directed. Make : Anchor/ cona/ Plaza
Supply only 7 watt LED lamp complete all as specified and directed. Make : Philips/ Bajaj/ Crompton Greaves
Supply only 2.5 mfd condensor for ceiling fan complete all as specified and directed. Make : Epcos/ Asian/ Tyton
Supply only PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 4 sqmm of 3 core complete all as spcified and directed. Make : Havells/ Polycab/ Plaza.
Supply only PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 6 sqmm 3 core complete all as spcified and directed. Make : Havells/ Polycab/ Plaza.
Supply only plug top 3 pin 15 amps AC 230 volts complete all as specified and directed. Make : Havells/ Cona/ Plaza
Supply only plug top 3 pin 5 amps AC 230 volts complete all as specified and directed. Make : Havells/ Cona/ Plaza
Supply only bakelite sheet not less than 3 mm thick of size 100 x 100 mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards
Supply only TPN, MCB 20 to 32 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Siemens/ Schneider/ L&T.
Supply only electronic fan regulator modular typre 230 volts, step type socket type, hum free 100/240 watt Make : Havells / Schnieder/ Crabtree.
Supply only insulation tape 25 mm width 10m long
Supply only electronic LED driver 36W suitable for 2' x 2' ceiling light indoor fitting of make Philips/ Luker/ Wipro/ Bajaj as directed by Engineer-in-Charge.
Supply only PVC rectangular/square block 75mmx75mmx35mm
Supply only Electronic ballast for 2 x 36/40 W flourecent tube light fittngs, 230V, Make : Sumo Slim EBE 236 TLD 240 of Philips or equivalent of Bajaj/CG
Supply only 4' 20W/ 18W LED tube rod suitable for existing fitting. Make : Philips, Bajaj, Havells
Supply only bell push Make : Anchor/ Cona/ Havells
Supply only bell push, modular 1 way
Supply only Electronic ballast for 28W TL5 lamp flourecent tube light fittngs, 240V, Make : Sumo Slim EBE 128 TL5 240 of Philips or equivalent of Bajaj/CG
Supply only Electronic ballast for 1x18 W flourecent tube light fittngs, 230V, Make : Philips or equivalent of Bajaj/CG
Supply only PVC gang box 2 way 15 amp . Make. Cona/SSK/Anchor
Supply only bakelite sheet not less than 3 mm thick of size 200 x 250mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards
Supply only bakelite sheet not less than 3 mm thick of size 250 x 300mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards
Supply only PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 2.5 sqmm 3 core complete all as spcified and directed. Make : Havells/ Polycab/ Plaza
Supply only 4 mfd condensor for ceiling fan complete all as specified and directed. Make : Epcos/ Asian/ Tyton
Supply only electric buzzer, AC 230 volt, single pole complete all as specified and directed. Make : Anchor/ cona/ Plaza
Supply only modular switch 1 way 6 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular Socket, 6A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular switch 1 way 16 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular Socket, 16A - 3/5 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular white cover plate with frame,3 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular white cover plate with frame,4 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular white cover plate with frame,6 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only modular switch 1 way 32 amp.2 module Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply only rigid, non-matalic, PVC conduit pipe, ISI marked, 32 mm bore, including bends, saddles, accessories complete all as specified and as directed. Make : Siemens/ ABB/ Legrand.
Supply only rigid, non-matalic, PVC conduit pipe, ISI marked, 25 mm bore, including bends, saddles, accessories complete all as specified and as directed. Make : Prince/ Supreme/ Diplast
Supply only switch socket combination outlet 3 in 1/ 3 pin 3 and 5 amps flush type with box
Supply only switch socket combination outlet 5 in 1/ 5 pin 5 and 15 amps flush type with box
Supply only electronic fan regulator 230 volts, step type, switch type, hum free 100/ 240 watt Make : Anchor/ Cona/ Havells
Supply only Double pole MCB 40 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Siemens/ ABB/ Legrand.
Supply only PVC batten of 15 mm (width) complete all as specified and directed. Make : Avon Plast/ Supreme/ Presto Plast
Supply only PVC batten of 20 mm (width) complete all as specified and directed. Make : Avon Plast/ Supreme/ Presto Plast
Supply only PVC batten of 25 mm (width) complete all as specified and directed. Make : Avon Plast/ Supreme/ Presto Plast.
Supply only TPN, MCB 40 to 63 amp, 240 v, 50 Hz AC suitable for ‘C’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 all as specified (Make/Model : Siemens/ ABB/ Legrand.
Supply only cordless bell musical type, AC 230 volt single pole, complete all as scpecifed and directed. Make : Anchor/ cona/ Plaza
Supply only PVC insulated and FRLS PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, 1.5 sqmm of 3 core complete all as spcified and directed. Make : Havells/ Polycab/ Plaza.
Supply only LED bulb (Green colour) 15Watt B22 holder based Make : Philips, Bajaj, CG
Supply only 10 watt LED lamp complete all as specified and directed. Make : Philips/ Bajaj/ CG
Supply only of 4 pin 18 watt CFL. Make: Crompton Greaves/ Havells/ Osram
Supply only of 4 pin 36 watt CFL. Make: Crompton Greaves/ Havells/ Osram
Outer body of MS sheet not less than 20 gauge suitable for 25 ltr geyser with white synthetic enameled paints taking down existing one complete all as specified and as directed.
Supply only of energy saving lamps 2W/3W/5W SUODI LIGHTING day light spiral type. Make : Philips/ Crompton Greaves/ Bajaj
Supply only small thread LED candle bulb 05 watt, warm white E-14, 2700K as per sample complete all as specified and directed. Make : Philips/ Wipro/ Bajaj.
Supply only Electronic ballast for 2 x 18 W flourecent tube light fittngs, 230V, Make : Philips or equivalent of Bajaj/CG
Supply only big thread LED candle bulb 05 watt, warm white E-27, 2700K as per sample complete all as specified and directed. Make : Philips/ Wipro/ Bajaj.
Supply only PVC gang box 2 way 05 amp . Make. Cona/SSK/Anchor
Supply only bakelite sheet not less than 3 mm thick of size 175 x 100mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards
Supply only bakelite sheet not less than 3 mm thick of size 200 x 200mm complete all as specified and as directed. Make : Hylam/ Formica/ Green laminated boards
Taking down carefully hanger lights for repair/ replacement of defective spare parts such as ballast, lamp holders, lamp, capacitor, ignitor etc of capacity 150/250/400 watts HPSV/HPMV/MH including cleaning internally and externally fixing back the fitting in same position after repair and test complete all as specified and as directed. (Note :- New spare parts shall be measured and paid separately as supply only and cost of labour for replacement is deemed to include in the unit rate quoted)
Supply only ignitor suitable for HPSV/ HPMV/ MH fitting of wattage 150/ 250/ 400 watts. Make : Bajaj/ CG/ Philips.
Supply only high wattage metal halide lamp in elliptical / tubular shape of 400 watts. Make : Philips / Bajaj/ Wipro
Supply only 33 mfd capacitor suitable for HPMV/ HPSV/ MH light fitting.
Supply only Mercury / Metal Halide lamp ballast with copper winding polyster filling and voltage taping at 220/240V for 400 W HPMV fittings Cat Part No BHL 400 X 261 of Philips or Bajaj/ Crompton Greaves
Supply only 20 mfd capacitor suitable for HPMV/ HPSV/ MH light fitting.
Supply only Mercury / Metal Halide lamp ballast with copper winding polyster filling and voltage taping at 220/240V for 250 W HPMV fittings Cat Part No BHL 250 X 261 of Philips or equivalent in Bajaj/ Crompton Greaves
Supply only high wattage metal halide lamp in elliptical / tubular shape of 250 watts. Make : Philips /Bajaj/ Wipro
Supply only electronic LED driver 70/75W suitable for hangar down light/ flood light fitting of make philips/ Wipro/ Bajaj/ CG/ Havells as directed by Engineer-in-Charge. indoor fitting of make Philips/ Luker/ Wipro/ Bajaj as directed by Engineer-in-Charge.
S&F in repairs 30 watt LED inverter street light with inbuilt IR (Infra Red) sensor for auto ON/OFF near to ASTRO sunrise and sunset timing alongwith additional provisioning of independently ON at dark/ cloudy weather and switch off in normal weather based on lux level of natural light for energy efficient lighting with attention free operation. Housing made of pressure diecast aluminium, top maintainable and front cover clear toughened glass with highly efficient secondary lens for better optics, with IP66 and IK05 protection, reverse polarity protection, high voltage cut off at 300 V + 10 V and 5 KV internal surge protection. Street light shall have inbuilt 3.7 V Li-ion battery pack of 5.2 Ah capacity for emergency light backup for 1.5 - 2 hours max at inverter load in case of power failure, efficiency > 100 lm/w, PF >, 0.95, THD < 10%, CRI >, 70, Driver efficiency >, 85% and is suitable for 50mm OD mounting pipe complete all as per specified and as directed. Make :- Halonix model No LED SL HLSLD - ML04 - 30 - CWL - INV - IRSEN - R or equivalent in Philips/ Bajaj
S&F in repairs 45 watt LED inverter street light with inbuilt IR (Infra Red) sensor for auto ON/OFF near to ASTRO sunrise and sunset timing alongwith additional provisioning of independently ON at dark/ cloudy weather and switch off in normal weather based on lux level of natural light for energy efficient lighting with attention free operation. Housing made of pressure diecast aluminium, top maintainable and front cover clear toughened glass with highly efficient secondary lens for better optics, with IP66 and IK05 protection, reverse polarity protection, high voltage cut off at 300 V + 10 V and 5 KV internal surge protection. Street light shall have inbuilt 3.7 V Li-ion battery pack of 5.2 Ah capacity for emergency light backup for 1.5 - 2 hours max at inverter load in case of power failure, efficiency > 100 lm/w, PF >, 0.95, THD < 10%, CRI >, 70, Driver efficiency >, 85% and is suitable for 50mm OD mounting pipe complete all as per specified and as directed. Make :- Halonix model No LED SL HLSLD - ML04 - 45 - CWL - INV - IRSEN - R or equivalent in Philips/ Bajaj
Note for item No 224 & 225 :- (a) The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. (b) The contractor shall submit warranty certificate from manufacturer for minimum 2 years. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor shall be measured as one length (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
S&F in replacement factory made powder coated distribution board VTPN, 4 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ Legrand
S&F in replacement factory made powder coated distribution board TPN, 4 way double door including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ Legrand
S&F in replacement on distribution board MCCB four pole, 125 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified. Make : Siemens/ L&T/ ABB
S&F metal clad switch socket triple pole and earth enclosure with three pin and earth plug with socket complete with on triple pole 32 Amps, 415 Volts MCB complete all as specified.Make :- Legrand /Siemens/ Schnieder.
Supply and Fixing in repairs of 4 feet surface mounted battern type luminaire with a power consumption not more than 16 W, luminaire lumen output of 2000 lumens, luminaire efficacy > 120 lm/W with an operanting voltage range from 140V-270V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and sleek design with width not more than. The luminaire shall have a CCT of 6500 K, CRI>80, power factor>0.95, SDCM<5, THD<10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content<5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/ EMC complaint and shall have a internal surge protection of 4 KV. The luminaire shall have Class-1 Electrical insulation, Class-B serviceability (The driver can be replaced at site level). The luminaire shall not weight more than 7 Kg and the luminaire and driver shall be BIS approved with "R" number mentioned. Make philips Cat No BN308 LED20S 6500 L120 PSU WH or equivalent in Bajaj or Wipro.
Note for item No 233 :- (a) LED Chip make shall be Nichia, Osram, Cree, Lumilid. (b) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED Chip used and luminaise respectively while getting sample and material approved. (c) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (d) The contractor shall submit warranty certificate from manufacturer for minimum 02 years.
Supply and fixing power contactor 63 amp for lighting control including taking down old u/s contactor swiches complete all as directed.make:- legrand cat part No. 412556 or equivalent in Schnieder/ L&T
S&F in repairs Electronic energy meter single Phase 5 to 30Amps range capacity complete all as specified. Make : BENTEC / L&T/ABB Note :- Old unserviceable meter shall be deposited to E/M store yard.
S& F replacement of convetional type post top fitting with LED Post tops lamp fitting 1x45 W LED made die cast aluminium with innovative glare free indirect lighting ditribution & IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed. Make : CG Cat No. LPTO-40-CDL/Bajaj Cat Part No. BRIL 45 W LED NW or equivalent in philips.
M&L for wiring for circuit complete submain wiring with 2 X1.5 sqmm single core PVC insulated, unsheathed FRLS 100 Volt grade multi stranded copper conductor cable drawn through and incl suitable dia rigid PVC conduit and accessories complete fixed surface to wall/roof/ceiling etc and incl 1.5 sqmm single core wire PVC insulated, unsheathed FRLS 1100v grade multi stranded copper conductor cable as earth continuity conductor etc including taking down existing sub main wiring of any size and all as specified. Note :- Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC Conduit and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC conduit and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor shall be measured as one length (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
S&F in replacement factory made powder coated distribution board SP & N 8 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ ABB
S&F in replacement factory made powder coated distribution board TPN, 4 way single door including bus bar, Neutral bar, standard DIN rail, earth bar complete all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ ABB
S&F in replacement on distribution board MCCB four pole, 100 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified. Make : Siemens/ L&T/ ABB
S&F in replacement integrated LED bulk head luminarie fittings in engineering plastic housing with clear prismatic /opal diffuser /pressure aluminium die cast housing in white powder coating minimum IP-65 protection, system wattage not more than 10 watt (lumen output not less than 800 lumen) power factor more than 0.9, with surge protection device minimum 2KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm. Make : Philips Cat part NO.WT202WLED6S NW PSU S2 PC or equivalent in Wipro/ Bajaj. Notes:- 1. The Contractor shall submit test report from manufacturer of LED fittings giving detail of each parameter /specifications of led luminaire mentioned in the BOQ item. 2. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 3. The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
S&F in repairs LED retrofit lamp 20W, warm white, (lumen output not less than 1350 lumens) with B-22 holder base with thermal conductive engineering plastic white colour housing and aluminium heat sink with specially designed fins clear /cool white, power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, CRI more than 80, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation all as specefied and directed. Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2. The contractor shall submit warranty certificate from manufacturer for minimum 2 years Make : Wipro cat part No. LL20-111-XXX-65NE3 or equivalent of Philips/ Bajaj
S & F in replacement 18 watt recess mounted sleek square down lighter enviornment friendly, new generation, energy saving with high power LED as light sources & clear glass inlcuding accessories all as specified and directed by Engr-in-Charge. Make /Model : Philips cat part No.DN 295B LED16S-6500 PSU WH/Wipro/ Bajaj. Note : 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2 The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
S&F in repairs Electronic energy meter 3 Phase 30 to 60Amps range capacity. Make : BENTEC / L&T/ABB. Note :- Old unserviceable meter shall be deposited to E/M store yard.
M&L Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 4 runs of 10 sqmm drawn through in and incl suitable size non metalic PVC conduit and all accessories fixed to wall/floors along with 10 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring all as directed. Make of conduit : Avon Plast/ Supreme/ Diplast Make of Cable : Plaza/Polycab/Havells Note: 4 runs of 10 sqmm cable along with one run of 10 sqmm cable for earth conductor alongwith suitable size PVC conduit shall be measured as one length
S&F XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 35 sq mm 3.5 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
S&F XLPE insulated,screened ,PVC Bedded,galvanised steel strip of wire armoured, electric power cable heavy duty with aluminium condutor 1100Volts grade cross sectional area 25 sq mm 4 core laid in trenches /ducts/fixed to wall/pole/ inside panel/ drawn through pipe including cable glands and terminal sockets etc including taking down existing cable all as specified and directed. Note : Excavation and earth work shall be measured and paid seperately. Make : Havells/ KEI/ Polycab
M&L in repairs Cable jointing kit for 1.1 KV grade cable for outdoor stright through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armored aluminium conductor cable of size 25 sqmm to 35 sqmm. Make : Reychems, Densons, M-Seal
Material and labour in repairs earthing complete with copper earth plate electrode of size 600mm x 600x 3.15 mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level),with top edge of earth plate not less than 1.5m below normal ground level, eart plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, magnesium sulphate (1 : 1 : 0.5), electrode connections using copper strip of size 20 x 3 mm thick (upto body of equipment) (max 7.5m) length by means of brazing / welding connected to main switch board or main control board or test point, protected by galvanised iron pipe light grade 40mm dia bore and watering pipe 20mm dia bore GI medium grade with funnel and wire mesh including all necessary(excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in elctrical plate No 3 of MES schedule Part-I (2009), testing on completion, complete all as specified and directed.
Note for item No 252 :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80 mm thick reinforced with XPM not less than 4Kg/ Sqm. PCC pit cover shall be constructed 500mm away from the edge of eath pit.
(ii) Rate shall include copper strip and protection pipe of length 7.5m, excess beyond 7.5m lenth required at site shall be measured and paid separately.
(iii) Earthing shall be tested after completion of work by the contractor in presence of Engr-in-charge, user and proper record shall be maintained duly signed by all concerned. Earth resistance tester will be provided by the contractor. Tester should be calibrated from authorised company/ lab.
(iv) Earth resistance should be less than 3 Ohm, In case the test results are not found below 3 Ohm, complete earthing will redone without any extra cost to Govt.
Supply and fixing in repairs copper strip 20 x 3mm thick as earthing lead fixed to wall/roofs etc all as directed. Note : All Joints should be joined by Exothermic Welding or Brazing.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 6 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 4 runs of 6 sqmm cable along with two run of 6 sqmm cable for earth conductor shall be measured as one length including taking down UNSV old wiring. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
S&F in replacement factory made powder coated distribution board SP & N 4 way double door, including bus bar, Neutral bar, standard DIN rail, earth bar complete including taking down UNSV DB all as specified and conforming to IS: 8623 all as specified. Make/Model : Siemens/ Schnieder/ Legrand
S&F in replacement on distribution board MCCB four pole, 63 Amp ultimate breaking capacity 16 KA complete conforming to IEC -61439-1 complete all as specified. Make : Siemens/ L&T/ ABB
S&F in replacement of convetional type boolard fitting with LED bollard light fittings suitable for 1x9 watt LED bollard in rectangular shaped vicotria design with opal acrylic diffuser and IP 65 protection inlcuding fixing arrangement with suitable flanged GI pipe base and PCC fixed on floor/ground all as specified and directed. Make /cat part No. CG cat no.LBLSN-10-CDL /Bajaj Cat Part No. BGBOS 600 9W LED /philips.
S&F in repairs LED retrofit lamp 15W, warm white, (lumen output not less than 1350 lumens) with B-22 holder base with thermal conductive engineering plastic white colour housing and aluminium heat sink with specially designed fins clear /cool white, power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, CRI more than 80, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation all as specefied and directed. Make : Wipro cat part No. LL20-111-XXX-65NE3 or equivalent of Philips/ Bajaj Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2. The contractor shall submit warranty certificate from manufacturer for minimum 2 years
S&F in repairs LED retrofit lamp 5W, warm white, (lumen output not less than 1350 lumens) with B-22 holder base with thermal conductive engineering plastic white colour housing and aluminium heat sink with specially designed fins clear /cool white, power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, CRI more than 80, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation all as specefied and directed. Make : Wipro cat part No. LL20-111-XXX-65NE3 or equivalent of Philips/ Bajaj Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2. The contractor shall submit warranty certificate from manufacturer for minimum 2 years
Supply and Fixing in replacement indoor decorative extruded aluminium anodised housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED T8 batten type luminaire (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation; 2 feet (appx) size, high efficiency electronic driver, system wattage 10 watt (lumen output not less than 1000 lumen), power factor more than 0.9, with surge protection device minimum 3KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, no UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified and directed. Make : Philips/ Wipro/ Bajaj
Taking down aluminum/copper point wiring on & including hard wood battens, surface conduit and board/ blocks etc or through conduits for light, socket or power point, fan point complete (Taking down of fittings such as switches, sockets, bells, ceiling rose, holders , regulators, light fittings, MCB, lamps etc shall be measured and paid seperately) and making good the disturbed plaster surfaces of wall, floor, ceiling and painting 2 coat of white wash/distamber to meet the existing surface and removing materials and debris to reinstate the premise neat and clean complete all as specified and directed.
M&L in repairs for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade ISI 694 marked cable for phase & neutral drawn through concealed PVC Conduit, ISI marked with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Conduit : Avon Plast/ Supreme/ Diplast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No. 266 here in before but for one 3 pin socket out 5 amp on the same board
All as per item No. 266 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 266 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L in repairs for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC casing Caping with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely. (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No. 271 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 271 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 271 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L in repairs for point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through Steel conduit with and including new MS/ cast iron sunken boxes duly painted with two coats of anticorrosive paint over a coat of red oxide primer on surface in touch with wall and synthetic enamel paint over a coat of red oxide on other side, covered with 3mm thick plastic laminated sheet for mounting switches, regulators, sockets etc including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed. Note: (Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
One switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No-276 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L for Sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and incl suitable size PVC existing steel conduit and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 4 sqmm cable along with one run of 4 sqmm cable for earth conductor shall be measured as one length. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
M&L for sub main wiring with PVC insulated unsheathed FRLS cable 1100 volts grade multi stranded copper conductor cable 2 runs of 6 sqmm drawn through in and incl suitable size PVC existing steel conduit and all accessories fixed to wall/floors along with 6 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 2 runs of 6 sqmm cable along with one run of 6 sqmm cable for earth conductor shall be measured as one length (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
S&F MCCB, 4 Pole, 200 Amps, thermal magnetic release adjustable type, 415 Volt, 36 KA including connecting using suitable size of aluminium lugs including taking down existing one complete all as specified and as directed. Make : L&T, ABB, Schneider
Supply and Fixing in replacement indoor decorative extruded aluminium anodised housing /CRCA sheet steel coated housing (suitably coated to improve resistance against corrosion) LED T8 batten type luminaire (LED batten shall be prewired box type) retrofit solution with and including replaceable retrofit cool day white LED tube rod with well designed aluminium heat sink /aluminium housing for excellent heat dissipation; 4 feet (appx) size, high efficiency electronic driver, system wattage 20 watt (lumen output not less than 2000 lumen), power factor more than 0.9, with surge protection device minimum 3KV, colour temperature not less than 5700K, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, CRI more than 80, glarefree, no UV radiation light fitting with wall mounting arrangement and making connections with PVC insulated copper conductor 3 core cable of 0.5 sqmm complete all as specified and directed. Make : Philips CAt part NO. 85395000 /Wipro cat part No. LL13-181-650 for rod and WIO921208 or equivalent in Bajaj
Note for item No 283 :- (a) The contractor shall submit to Engineer-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively while getting sample and material approved. (b) The contractor shall also submit test report from the manufacture to comply with all requirements and specifications given in the contract. (c) The contractor shall submit warranty certificate from manufacturer for minimum 02 year.
Supply and fixing in repairs pathway light decorative retrofit LED fitting with 9 W LED bulb including necessary excavation, PCC foundation, 1.5 mtr long GI pipe light grade 50 mm bore with base plate, cable junction box with 2 pole connector 32 A capacity including cable entry and exist knockouts, 1.5 mtr length 3 core 1.5 sqmm PVC insulated copper round cable from connector to light fitting, disposal of soil to outside MD land including taking down existing one all as specified and directed by Engineer-in-Charge. Make / Model of Light fitting : Athena 2 Prismatic of Havells Cat Part No : LHDC12115099 or equivalent in Wipro or CG.
M&L for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC casing caping with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Casing Capping : Polycab/ Modi/ Presto Plast Make of Wire : Plaza/ Polycab/ Havells Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No. 286 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 286 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 286 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
M&L in repairs for point wiring complete with 1.5 sqmm single core PVC insulated, unsheathed fire retacable 1100 volts grade, multi stranded with copper conductor drawn through and incl PVC Conduit with accessories in wall/roof/ceiling etc incl MS modular terminal boxes, concealed surface to walls covered with modular plates with cover etc and 1.5 sqmm PVC insulated, unsheathed copper conductor multistranded cable 1100V grade as earth continuity conductor & connecting to common earth dolly all as specified for Make of Cable : Plaza/ Polycab/ Havells Make of Conduit : Supreme/ Diplast/ Avon Plast Note: (a) Switches, sockets outlets, blanking plate, Light fittngs, fans, bells & regulators will be measured and paid for separetely). (b) Connection of wire with switch, socket shall be through copper thumble (lugs) only.
One light point/fan/bell point controlled by one switch
All as per item No. 291 here in before but for One 3 pin socket out 5 amp on the same board
All as per item No. 291 here in before but for one switch socket outlet 3 pin 5 Amps on independent board
All as per Sl No 291 above but Wiring with 4 Sqmm copper multistranded unsheathed cable and 4 Sqmm copper cable for earth continuity conductor controlled by one 15A switch socket independently
Supply and Fix switch piano flush type 5 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
Supply and Fix switch piano flush type 15 Amps 240 volts single pole one way. Make : Anchor (Model Penta PC), Havells (Reo), SSK (Topline)
Supply and Fix shuttered socket outlet 3 pin 5 amps, flush type
Supply and Fix shuttered socket outlet 2 in 1, 3 pin, 5 and15 amps
Supply and Fix modular switch 1 way 6 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix modular Socket, 6A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix modular switch 1 way 16 amp.1 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
Supply and Fix modular Socket, 16A - 2/3 pin combined 2 module. Make : Legrand (Model- Arteor), ABB (Cheiron), Schneider (Ulti)
S&F Surface & wall mounted LED fitting including 5 watt LED tube rod complete with all accessories internally, pre-wired, connecting up with twin core twisted flexiable copper conductor cable of suitable size including taking down old light fitting. Make : Bajaj Cat No 112405BCLSB 05 WH or equivalent of Philips /Havells.
S&F in repairs LED retrofit lamp 9W, warm white, (lumen output not less than 1350 lumens) with B-22 holder base with thermal conductive engineering plastic white colour housing and aluminium heat sink with specially designed fins clear /cool white, power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, CRI more than 80, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation all as specefied and directed. Make : Wipro cat part No. LL20-111-XXX-65NE3 or equivalent of Philips/ Bajaj Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2. The contractor shall submit warranty certificate from manufacturer for minimum 2 years
S&F in repairs 36 W LED recessed 2x2 luminaire with classic design & glare free soft illumination. Housing with white high reflection powder coated (RAL9016) CRCA sheet. Glare free, Opal diffuser for symmetrical light distribution fixed in separate CRCA sheet frame held in with housing by screws for easy maintenance. High efficiency long life LED package in integral module with lumen efficacy of >100 lm/w, viewing angle of 100° to ensure better uniformity. Powered by an independent Isolated, SELF Output electronic LED driver (SMPS based constant current supply) efficiency of 85% with built-in Surge protection 3Kv. System Lumen Output of 3000 lumens. CRI >80, Color temperature5700±300K, THD <10% and PF >0.95, IP20, IK02.Life class of 50,000 hrs @ L70, Operating Temperature: -10 TO +45 DEG.C; Input Supply Voltage Range:150-277 V, Frequency :50-60 HZ. Driver Safety requirement stds: IS 15885-2-13, Test Report to be submitted. Make : Bajaj Cat Part No Skylux - BZRSQL 30W GZi WH / Philips cat No RC 355 BLED 33-6500 PSU OD WH or equivalent in Wipro.
M&L for sub main wiring with PVC insulated unsheathed FRLS 1100 volts grade multi stranded copper conductor cable 4 runs of 4 sqmm drawn through in and incl suitable size PVC casing capping and all accessories fixed to wall/floors along with 4 sqmm PVC insulated unsheathed copper conductor multi stranded cable 1100V grade as earth continuity conductor and connected to common earth dolly including taking down existing sub main wiring of any size. Note: (a) 4 runs of 4 sqmm cable along with two run of 4 sqmm cable for earth conductor shall be measured as one length including taking down UNSV old wiring. (b) Connections of cables with MCBs or bus bars shall be done through appropriate size brass/copper thimbles. Make:- Havells/ Polycab/ Plaza.
Supply and fixing building security luminaire of watt 10 watt LED 1000 lumens light High power LED, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system with excellent thermal management including prewired and taking down UNSV street light fittings all as specified and directed, Make : Philips/ Wipro/ Bajaj. Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2. The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
Supply and fixing road lighting/ building security luminaire of watt 20 watt LED 2000 lumens street light High power LED, with unique peanut lens to ensure uniform distribution, higher spacing between poles and maintenance free system with excellent thermal management including prewired and taking down UNSV street light fittings all as specified and directed, Make : Philips Cat No BRP022 LED 20 CW MR S1 PSU GR or equivalent in Wipro/Bajaj. Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2 The contractor shall submit warranty certificate from manufacturer for minimum 2 years.
Supply and fixing in repairs electronic driver 10W suitable for bldg security light of make : Bajaj/ Philips all as directed by Engineer-in-Charge.
Supply and fixing in repairs electronic driver 20W suitable for bldg security light of make : Bajaj/ Philips all as directed by Engineer-in-Charge.
S&F in replacement 9 watt surface mounted sleek square down lighter enviornment friendly, new generation, energy saving with high power LED as light sources & clear glass including accessories complete all as specified and as directed. Make : Philips/ Wipro/ Bajaj
S&F in repairs LED retrofit lamp 12W, warm white, (lumen output not less than 1350 lumens) with B-22 holder base with thermal conductive engineering plastic white colour housing and aluminium heat sink with specially designed fins clear /cool white, power factor more than 0.9, with surge protection device minimum 2KV, color temperature not less than 6000K, CRI more than 80, LED driver with constant output voltage and current at input voltage of 140 Volt to 285 Volt AC at 50 Hz, glarefree, 0 UV radiation all as specefied and directed. Make : Wipro cat part No. LL20-111-XXX-65NE3 or equivalent of Philips/ Bajaj Notes:- 1. The contractor shall submit to Engr-in-Charge LM-80 and LM-79 report from the NABL approved lab of LED chip used and luminaire respectively. 2. The contractor shall submit warranty certificate from manufacturer for minimum 2 years
Supply, installation, commissioning and testing of Factory assembled, Floor mounted, free standing, type tested LT Feeder Pillar Panels, with canopy, as per electrical specifications for outdoor installation, to be made of IP65 Polycarbonate modular enclosures. The Enclosures made of Polycarbonate, should be weather/ vermin proof, anti-acid, anti-corrosive, UV resistance in accordance with IEC 61439-1, Fire retardant and Self-extinguishing in accordance with IEC 60695-2-11, UL subject 94 for flammability V-0, should pass glow wire test for 960° in accordance with 60695-2-11. Degree of protection against mechanical load should be IK 08 (5 Joule) in accordance with IEC 62262, IP 65 in accordance with IEC 60529 & IEC60439-1, should have Dielectric Properties, RoHS compliant & Halogen free. The manufacturer of boards/panel shall submit a copy of type test reports as per above-mentioned norms either from UL/ERDA/CPRI/NABL labs in India. The panels should be modular and compartmentalized in construction with opaque and transparent doors, properly tightened to base with thermoplastic screws having sealing gaskets of extruded silicon rubber to withstand adverse weather effects. The depth of modular enclosures should be above 200mm for air circulation & to minimize temp rise. Panel should be fitted with 01 No polycarbonate IP 65, 9W LED translucent bulk head luminaire, 6500K, PF > 0.95 under canopy for easy maintenance. Panel should be fitted outside with 01 No of 16A 3P IP 65 industrial socket and 01 No of 32A 5P IP 65 industrial socket. 3 phase and neutral 400 amps current carrying capacity copper bus bar insulated with colour coded heat shinkable sleeves with SMC/DMC insulators, complete with the following switch gears and mounting the panel board on ground with PCC (1:3:6) bedding upto a height of 45 cm above ground level, including dismantling and taking out old u/s LT Panel Board and remove from site reconnecting existing LT Cables with new panel board complete all as directed :-
M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 25x6mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
(a) All Joints should be joined by Exothermic Welding or Brazing. (b) After completion of work earthing shall be tested by the contractor in presence of Engineer-in-Charge, User and proper record shall be maintained duly signed by all concerned. (c) Earth resistance tester shall be provided by the contractor. It should be caliberated from authorised company/ lab. (d) After testing if desired earth resistance of less than 5 Ohm is not obtained, the earthing will be redone at no extra cost to Govt till desired result is obtained.
M&L in repairs Galvanised Earth strip of size 25 x 6 mm fixed on proper post insulator at the instrument end complete all as per specified and as directed.
devan enterprises
M/S SRI BALAJI ENTERPRISES
M/S J J ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .