Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LAccepted-AOC WARD NO 4 HARI NAGAR BALUDA ROAD SOHNA GURUGRAM HARYANA 122103 | SOHNA | GURUGRAM | HARYANA | 122103 | L1 | Accepted-AOC L1 |
Tender Value
₹1.1 L
EMD Value
₹2,300
Closing Date
12 Oct 2020, 5:00 pmClosed
RAJA NAGENDER SINGH
NIRMAN SADAN , 4TH FLOOR, CIVIL LINES , PWD B and R (Elect.)GURUGRAM
Special repair/renovation of Labour Room in existing B.K. Hospital at Faridabad (Pdg. E.I. Only).
2020_HRY_141180_2
PWD (Elect.) 2020
Open Tender
Electrical Works
Works
60 days
PWD (Elect.) 2020
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer, Electrical Division
₹2,300
10 Mar 2021
1 Oct 2020
13 Oct 2020
1 Oct 2020
12 Oct 2020
1 Oct 2020
Amount
Moulded case Circuit breakers. Supply and erection of moulded case circuit breakers on wall or on existing pedestal including bonding to earth and necessary connections. 100 amp.to 220 amp.415 V,10 KA 3-phase.
Supply and erection of M.S. angle iron frame duly welded for housing M.S. sheet & main switches etc. on it, fixed on wall by means of suiteble size of rag bolts with cement concrete ,duly painted with three coats of approved paint including one coat of red oxide. Size 40 mm x 40 mm x 6 mm.
M.S.Sheet . Supply and erection of 3 mm thick mild steel sheet duly welded on existing M.S. angle iron frame for fixing the main switches etc. as required, duly painted with three coats of approved paint including one coat of red oxide.
Miniature Circuit Breaker and Isolator. Supply and erection of miniature circuit breaker/ isolator 240/415 V in the existing distribution board including making necessary connection. Miniature circuit breakers of 9 KA breaking capacity. SP MCB of 9 KA breaking capacity 6 amp. to 32 amp.
TPN MCB of 9 KA breaking capacity 40 amp. to 63 amp.
Supply and erection of Fittings and Accessories. Erection only of 1x40 watts or 2x40 watts 1220 mm long /1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point.
Erection and carriage of fans. Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work.
Pipe Laying. Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. Heavy gauge welded conduit pipe 20 mm dia 1.60 mm thickness on surface.
Heavy gauge welded conduit pipe 25 mm dia 1.60 mm thickness on surface.
Supply and erection of under ground cable, loose in existing pipe or trenches complete with necessary connections . 50 Sq. mm 3.5 Core Ard. Cable .
Supply and erection of suitable compression type brass cable glands for underground Cable. 25 Sqmm to 50 Sqmm Cable 2 to 4 Core.
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Cable size 1.5 sq.mm(3/ 0.81 mm)
Cable size 2.5 sq.mm(3/ 1.05 mm)
Cable size 4.0 sq.mm(7/ 0.85 mm)
Cable size 6.0 sq.mm(7/ 1.05 mm)
Supply & erection of PVC conduit pipe ISI marked(Medium) recessed in wall/ ceiling etc. including cost of PVC bends, inspection boxe and all other material required to complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work. 25 mm dia
PVC Insulated copper wiring in recessed MS conduit . Wiring for light point/ fan point/ exhaust fan point/ call bell point and 5 amp. plug point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed MS conduit with modular switch and socket, modular inner and outer plate, suitable GI box etc. with all labour, material, chasing, refelling of walls complete in all respect upto entire satisfaction of Engineer in Charge . Light Point/Exhaust fan Point Short Point
Medium Point .
Long Point .
Fan Point Medium Point .
Long Point .
3 pin 5 amp. plug point including earthing the 3rd. pin etc. Short point.
3 pin 15 amp. plug point with 4 sq mm PVC insulated copper conductor cable including earthing the 3rd. pin etc. Long point
Supply and erection of load line i.e. double door TPN vertical distribution board suitable for MCCB as incommer on existing angle iron board / on wall / pedestal including making necessary connection with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-charge of work 12 way Double door TPN distribution board suitable for 100 amp. 4 pole MCCB but without cost of MCCB. (Make : Havell's / Standard)
Supply and erection of 1 no. 16 way moduler box made of G.I. sheet with inner & outer plate including cost and fixing of 3 nos. sockets and 3 nos. switches of 10 amp and 1 no. multi socket and switch of 16/20 amp, M.S. box duly recessed in wall, cost of necessary cement and sand mixture making necessary connection complete in all respect upto the entire satisfaction of Engineer-in-charge of work. (for computer point )
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .