AGE I POKARAN
MILITARY ENGINEER SERVICES AGE I POKARAN MIL STATION POKARAN 345021
REPAIR AND MAINT OF STREET LIGHTS,DG SETS ETC IN AREA UNDER AGE(I) POKARAN
2022_MES_508752_1
8150/E8
Open Tender
Civil Works
Item Rate
180 days
AGE I POKARAN
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE I POKARAN
₹14,000
Yes
27 Jun 2022
17 Feb 2022
21 Mar 2022
17 Feb 2022
18 Mar 2022
4 Mar 2022
18 Feb 2022 - 25 Feb 2022
Amount
M&L for cleaning down complete body including fitting and fixture of desert cooler of air flowing capacity 4000/5000 Cum/per hour of any make with wire including removal of all sludges, loose paints, dust, dirt etc and prepared the surface clean for painting and applying two coats of rubber based paint inside the water tank complete, including rewriting of MES No. complete all as specified & directed by Engr-in -charge.
S&F fan motor of single phase 230 Volt, 1400 RPM 3 speed 1/8 HP for desert cooler incl cast iron rings for motor with clamps nuts & bolts complete all as specified & directed by Engr-in -charge. MAKE : COOL HOME/ KHAITAN/ POLAR/CG
-Ditto- all as item No 2 above but fan motor 24" sweep 900RPM complete all as specified & directed by Engr-in -charge.
S&F PVC flexible pipe of 16 mm outer dia complete with PVC elbow, tee as required complete all as specified & directed by Engr-in -charge.
S&F repair,wood wool pad (set of three) minimum weight 0.8 Kg, proper fixed in 3 side of panels of desert cooler complete all as specified & directed by Engr-in -charge.
S&F in repair,plug top 3 pin 5 Amp with cable upto 2mtr, 230 Volt (ISI marked) complete all as specified & directed by Engr-in -charge.
S&F in repair,PVC insulated and PVC sheathed round flexible three core copper conductor cable of size 40/0.0076 Sqmm including making necessary connections for desert coolers complete all as specified & directed by Engr-in -charge.
S&F capacitor 4 Mfd for fan motor of desert cooler complete all as specified & directed by Engr-in -charge.
Supply and replace water spray pump 1/30 HP for desert cooler . MAKE : COOL HOME/ KHAITAN/ POLAR/CGcomplete all as specified & directed by Engr-in -charge.
S&F iron fan blade aluminium coated for fan motor of desert cooler of 20 inch sweep complete all as specified & directed by Engr-in -charge.
S&F PVC 3 way distributor suitable for 15 mm flexible pipe with nuts & screws for desert cooler complete all as specified & directed by Engr-in -charge.
S&F PCB kit control card suitable for 50/75 KVA voltage stabilizer incl removing old unsv PCB kit complete all as specified & directed by Engr-in -charge.
Repair to single phase voltage stabilizer of following capacity rewinding of transformer , replacement of new wiring with relays, switches & suitable voltmeter including testing and commissioning complete all as specified & directed by Engr-in -charge. a) 5.0 KVA capacity
b) -Ditto- as per item No.14 above but, 3.0/2.0 KVA capacity complete all as specified & directed by Engr-in -charge.
Supply and fix 4 mm 2 core, 240volts Al. conductor cable heavy duty PVC insulated ISI marked complete all as specified & directed by Engr-in -charge.
S & F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified & directed by Engr-in -charge.
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified & directed by Engr-in -charge.
S&F of GI tubing light grade of size 40/50mm for protection of cable in trenches/on pole complete all as specified & directed by Engr-in -charge.
S&F MCB 63 Amps 415 volts triple pole 16 KA repturing capacity complete all as specified & directed by Engr-in -charge.
S & F MCB100 Amps 415 volts triple pole 10 KA repturing capacity complete all as specified & directed by Engr-in -charge.
Taking down old unserviceable LT cable, supply and Laying in trenches/through pipes/ducts or on poles/walls jointing to O/H conductor, LT panels, main switch with cable size aluminum lugs and testing. XLPE insulated, armoured heavy duty electric cables with aluminum conductor, 1100 volt grade, complete all as specified directed by Engineer In charge of cross sectional area and core of following sizes:- Note : Excavation and earth work, sand, pipe and stone patti will be measured and paid separately. (a) Size of cable 16 Sq.mm 4 Core
(b) -Ditto- as per item No.22 above but, Size of cable 10 Sq.mm 2 Core complete all as specified & directed by Engr-in -charge.
Excavation in trenches not exc 1.5m wide and n. exc 1.5M deep for fdn / trenches and getting out for soft / loose soil complete all as specified & directed by Engr-in -charge.
Removing excavated material any type n exc 50m and depositing at a level n.exc 1.5M above ground complete all as specified & directed by Engr-in -charge.
Returning/filling in layers, spreading leveling, watering and well ramming in layers n.exc 25m in sof/loose soil complete all as specified & directed by Engr-in -charge.
M&L for sand cushioning to PVC cable with tibba sand and punning to provide required cover complete all as specified & directed by Engr-in -charge.
M & L minor overhauling of DG set of following capacity including cleaning of rediator, replacing the coolant, replacement of filter elements complete sets, cleaning of air filters, replacing of engine oil, replacement of rubber hose pipes, replacement of oil seals all as per annul maintenance chart as recommended by the manufacturing and testing up to satisfaction complete all as specified and directed by Engineer in charge. Note : Spare part / materials other than coolants and engine oil are deemed to be included in the above quoted rate. (a) 43/45KVA
(b) -Ditto- as per item No.28 above but, 63/100 KVA complete all as specified & directed by Engr-in -charge.
(c) -Ditto- as per item No.28 above but, 20/30 KVA complete all as specified & directed by Engr-in -charge.
(d) -Ditto- as per item No.28 above but, 160 KVA complete all as specified & directed by Engr-in -charge.
S&F controller relay system of 160 KVA DG set as per exisiting system recommended by the manufacturing and testing up to satisfaction complete all as specified & directed by Engr-in -charge.
S&F controller relay system of 63/100 KVA DG set as per exisiting system recommended by the manufacturing and testing up to satisfaction complete all as specified & directed by Engr-in -charge.
OLIVE EXPORTS PVT LTD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .