| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.5 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹44.0 L+₹53,529 (1.23%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹45.1 L+₹1.6 L (3.74%)Rejected-Finance NAU PUKHRI ROAD MILLAN PALLY BYE LANE 2 NEAR GOYAL PALACE PO DISTT TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹46.0 L+₹2.5 L (5.69%)Rejected-Finance 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹49.5 L+₹6.0 L (13.9%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
23 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Chabua
GE (AF) CHABUA, POST-CHABUA AIR FIELD, DIST-DIBRUGARH, ASSAM-786102
REPAIR/MAINTENANCE OF AC PLANTS, 3 PHASE SPLIT ACs AND ALLIED WORKS AT STNS UNDER GE (AF) CHABUA
2022_MES_560139_1
407/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) Chabua
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE(AF) CHABUA
₹88,000
Yes
15 Dec 2022
28 Oct 2022
25 Nov 2022
28 Oct 2022
23 Nov 2022
16 Nov 2022
28 Oct 2022 - 4 Nov 2022
Amount
Descaling the condenser and circulating the descaling solution (hydrochloric acid) with pump, brushing the tubes and wherever required stubborn sealing without damaging the tubes replacement of gasket and drilling the unserviceable nuts & bolts assembling back for the following capacity:-
Stripping out the dirty pre filter/re-filter from AHU and complete cleaning of filter, using by air blower /fresh water system and drying in sun after refixing as same as per the standard practice for 3X24 TR & 2 X12 TR in various AC Plant all as specified and directed.
Supply and fixing in repair Thermometer for measuring the water temperature having range (0 to 50) °C complete all as specified and as directed.
Stripping out for servicing/overhauling and rewinding of 3 phase 415 volt 50HZ, CT fan motor as following capacity motor including renewal of the wear out spare parts like 02 bearing, Greasing, varnish heating /drying and painting of the motor, all as specified and as directed.
Upto 01 HP
Disconnecting and removing the electric mono block type pump motor of cap 7.5 HP 415V from the installed position and loading, unloading and transporting to authorized nearest work shop for rewinding, servicing/overhauling with super enameled copper winding wire of existing gauge incl all insulating materials such as insulation paper, sleeves, tape varnish heating/drying and replacement of 02 Nos ball bearing, new bronze impellor, greasing and gland packing complete all as specified and as directed.
Supply and charging in topup of refrigerant gas R-22 complete all as specified and as directed.
Supply and charging in topup refrigerant gas R-407 complete all as specified and as directed.
Supply and pouring in topup compressor oil complete all as specified and as directed.
Supply & Fixing in repair V belt (V Belt no. B-69) for compressor unit complete all as specified and as directed.
Supply & Fixing in repair V belt driving V Belt no. A-21 for AHU chamber complete all as specified and as directed.
Supply & Fixing in repair 3 Pole aux power contactor-Type MNX 32, 55-63Amps complete all as specified and as directed.
Supply & Fixing in repair contactors AC type operated 03 Pole 30 Amps complete all as specified and as directed.
Supply & Fixing in repair on Auxillary contactors block, first left /first right Each 01NO+01NC complete all as specified and as directed.
Supply & Fixing in repair thermal over load relay range 3.5-5 amps complete all as specified and directed.
Supply & Fixing in repair thermal over load relay range 1-1.4 amps complete all as specified and directed.
Supply and fixing in repair compound pressure gauge for gas 0 to 150 PSI, complete all as specified and directed.
S&F in repair Low pressure switch complete all as specified and directed.
S&F in repair High pressure switch complete all as specified and directed.
Supply & Fix in repair of thermostat switch complete all as specified and directed.
Supply & Fix in repair of dryer 5/8 all as specified and directed.
Supply & Fix in repair of dryer 1/2 all as specified and directed.
Supply & Fix in repair expensation valve all as specified and directed.
Supply and fixing in repair 0-150 water line pressure gauge 100 mm dia complete all as specified and directed.
Supply and fixing in repair sensors suitable for 12 TR AC Plant complete all as specified and directed.
Supply & Fix in repair shell and tube type condenser suitable for 5.5 TR compressor including cutting, brazing, welding, Nitrogen testing complete all as specified and directed. Note:- Nitrogen testing and refrigerant charging is included in quoted rate.
Supply and fixing in repair sensors suitable for 24 TR AC Plant complete all as specified and directed.
Supply and fixing in repair contactor type ML -2 04 Pole 32 A complete all as specified and directed.
Supply and fixing in repair power circuit board (Mother Board) for 5.5TR 3-phase complete all as specified and as directed.
Supply and fixing in repair power circuit board (Mother Board) for 24 TR 3-phase complete all as specified and as directed.
Shifting/Transporting repairable out door 03 phase 50 HZ split /ductile AC 3TR from various location (Chabua) to contractor’s workshop for repair & replacement of compressor unit, jointing by brazing leakage checking vacuum, servicing, overhauling including cleaning of air filter checking of wiring and rectification of any nature of defects, replacing only of spares as condenser PCB repair, contactor repair, complete refrigerant charge required and refixing at the site of removal complete machine and testing complete all as specified and directed. Note:- (i) Repair work whould be carried out, respective items of this schedule accordingly measured and paid separately. (ii) Spare parts shall be of OEM/existing make.
Supply, commissioning & testing scaled type Reciprocating compressor unit of capacity 03 TR complete all as specified and directed. Note:- R-22 gas shall be measured and paid separately.
Supply and fixing in repair Indoor door pvc fan blower 03 TR unit complete all as specified and directed.
Dismantling and taking down carefully u/s indoor electronic type power circuit board at existing location repair by artisan & refixing testing of split type AC of capacity 03 TR complete unit all as specified and directed by Engineer-in-Charge.
Dismantling and taking down carefully u/s outdoor electronic type power circuit board at existing location repair by artisan & refixing testing of split type AC of capacity 03 TR complete unit all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair power circuit board (Mother Board) indoor/outdoor type for 3 TR split AC, 3-phase complete all as specified and as directed.
Supply and fixing in repair single phase preventor complete all as specified and directed.
Supply & fixing in repair digital panel meter VAF+PF (square type 96X96mm) input voltage measurement range 17-20 VAC (P-P) complete all as specified and directed.
Supply & fixing in repair thermal overload relay range 20-33 Amps complete all as specified and directed.
Supply & Fix in repair indoor fan motor suitable for 3 TR split AC all as specified and directed.
Supply & Fix in repair outdoor fan motor suitable for 3 TR split AC all as specified and directed.
Supply & Fix in repair fan blade (indoor door) 24" suitable for 3 TR split AC all as specified and directed.
Supply & Fix in repair, commissioning & testing sealed type scroll compressor unit of capacity 5.5 TR for 2x12 TR central AC Plant, R-407, 03 phase 50HZ of OEM or equivalent in approved make, complete all as specified and as directed. Note:- R-407 gas, shall be measured and paid separately.
S & F in repairs, Keniform 2m length of best quality for split type AC to insulation copper pipe complete all as specified and as directed.
Supply & Fix in repair copper pipe 5"/8" suitable for 3 TR split AC all as specified and directed.
Supply & Fix in repair copper pipe 3"/8" suitable for 3 TR split AC all as specified and directed.
S&F in repair of Condensor Safety valve Size 3/8” complete all as specified and as directed.
S&F in repair contactor 9-30 Amp complete all as specified and as directed.
S&F in repair contactor MNX-18 complete all as specified and as directed.
S&F in repair fan assembly of cooling tower capacity 50TR size 1200 mm complete all as specified and as directed.
S&F in repair water distribution system for cooling tower capacity 50TR complete all as specified and as directed.
S&F in repair FRP Compound for repair of FRP cooling tower complete all as specified and as directed.
S&F in repair PVC Eliminator 24 TR capacity of cooling tower complete all as specified and as directed.
S & F in repair expensation valve for 5.5 TR, 3 Phase AC Plant complete all as specified and as directed.
Supply & Fix in repair MCB TPN of 10-32 Amps complete all as specified and as directed.
Supply & Fix in repair MCB TPN of 63 Amps complete all as specified and as directed.
Supply, installation, testing and commissioning of shell and tube type evaporator chiller unit of 2x12 TR AC plant including cutting, brazing, welding, Nitrogen testing and complete insulation og evaporator by EPDM nitrile rubber insulation including taking down old unsv evaporator complete all as specified and directed. Note:- Nitrogen testing and refrigerant charging is included in quoted rate.
Supply & Fix in repair commissioning & testing sealed type scroll compressor unit of capacity 5.5 TR. R-407, 03 phase 50HZ for 11 TR package type AC plant of OEM or equivalent in approved make, complete all as specified and as directed. Note:- R407 gas, shall be measured and paid separately.
Supply & Fix in repair drain pipe of length 3m suitable for 3TR split AC all as specified and directed
Supply, commissioning & testing in repair scaled type Reciprocating compressor unit of capacity 12 TR, R-407 all as specified and directed. Note:- R-407 gas shall be measured and paid complete all as separately.
Disconnection, taking down and dismantling including necessary servicing & testing of Dehumidifier of 3 KVA capacity all as specified and directed. Note:- Necessary parts required for repair shall be measured and paid separately.
Supply only heating element suitable for 3 KVA capacity Dehumidifier complete all as specified and as directed.
Supply only thermostat suitable for 3 KVA capacity Dehumidifier complete all as specified and as directed.
Supply & Fix in repair Switch fuse unit TP 415V AC, 50 Hz with neutral link complete all as specified and as directed.
Descaling the condenser and circulating the descaling solution (hydrochloric acid) with pump brushing the tubes and wherever required stubborn sealing without damaging the tubes replacement of gasket and drilling the unserviceable nuts & bolts assembling back for 3 x 80TR AC plant capacity complete all as specified and as directed.
Stripping out the dirty pre filter/re-filter from AHU and complete cleaning of filter, using by air blower /fresh water system and drying in sun after refixing as same as per the standard practice for 3X80 TR AC Plant all as specified and directed.
Servicing and maintenance of 170 KW Hot water generator complete by opening the existing assembly and draining out complete water, cleaning the container, checking of serviceability of heating element, pressure gauge etc. and reassembling the same and testing complete all as specified and as directed.
Supply and fixing in repair Digital step controller display complete set for hot water generator 170 KW (Model: VW170, Make: KECL) complete all as specified and directed.
Supply & Fix in repair commissioning & testing sealed type scroll compressor unit of capacity 20TR. R-407, 03 phase 50HZ of OEM or equivalent in approved make for 3x80 TR AC Plant complete all as specified and as directed. Note:- R-407 gas shall be measured and paid separately.
Supply and fixing in repair power circuit board (Mother Board) for 80 TR 3-phase complete all as specified and as directed.
Supply and fixing in repair sensors suitable for 3 x 80 TR AC Plant complete all as specified and as directed.
Taking out the defective dehumidification pump set along with motor of capacity 3.5 HP, 230 volts, SP from the AHU by disconnecting electrically and mechanically, shifting to civil workshop, dismantling the same to remove burnt out windings and defective parts, rewinding the motor with super enemelled copper winding wire incl all insulating materials all as per existing, varnishing and drying etc complete and replacing the bearings/bushes as per existing size, replacing the pump impeller as per existing specification, reassembling the same, shifting to original site, reconnecting electrically and mechanically and testing for proper working complete all as specified and directed.
Disconnecting and removing the electric blower motor of cap 15 HP 415V from the installed position and loading, unloading and transporting to authorized nearest work shop for rewinding, servicing/overhauling with super enameled copper winding wire of existing gauge incl all insulating materials such as insulation paper, sleeves, tape varnish heating/drying and replacement of 02 Nos ball bearing, new bronze impellor, greasing and gland packing complete all as specified and as directed.
Schedule of Credit
M/s HALDER ENTERPRISE
MAA COMMUNICATION
M/S S. P. ENTERPRISE
M/S K S Enterprise
J D construction
NChetia and Sons Trading
FREEZCON
STANDARD ELECTRIC WINDERS
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .