Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAccepted-AOC H NO 496 SECTOR 10 GURGAON 122001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹22.6 L+₹1.0 L (4.81%)Rejected-Finance NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹23.5 L+₹2.0 L (9.42%)Rejected-Finance 29 108 A STREET NO 10 VISHWAS NAGAR DELHI 110032 | DELHI | SHAHDARA | DELHI | 110032 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹26.1 L+₹4.5 L (21.1%)Rejected-Finance RAMA PARK A 121 BLOCK A UTTAM NAGAR WEST DELHI DELHI 110059 | DELHI | WEST DELHI | DELHI | 110059 | L4 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹49.0 L
EMD Value
₹97,900
Closing Date
26 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Delhi Cantt 110010
Garrison Engineer South Delhi Cantt 110010
WELCOME MAINT AND ALLIED SERVICES IN H TYPE OFFICERS MD ACCN AT SHANKAR VIHAR UNDER AGE B/R-II AND AGE E/M OF GE (SOUTH) DELHI CANTT-10
2022_MES_554949_1
GE/DS-74/2022-23
Open Tender
Civil Works
Item Rate
270 days
GE South Delhi Cantt
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE South Delhi Cantt
₹97,900
Yes
28 Nov 2022
28 Sept 2022
28 Oct 2022
28 Sept 2022
26 Oct 2022
12 Oct 2022
Amount
M&L for prepartion of old distemperd/painted wall surface by washing down, rubbing and stopping including brooming down or steel wire brushing scrapping down smoke soot, moulds moss and efforescent salts and trading oil and greasy spots thereafter filling of holes and cracks with wall care putty to obtain an even and smooth wall surface and applying one coat of oil bound distemper on wall surface including scaffolding arrangement, trestles, ladders complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 1 above but two coats of oil bound distemper complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 1 above but one coat of white wash on ceiling, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old plastered surfaces of wall thereafter filling of holes and cracks with wall care putty to obtain an even and smooth wall surface and applying one coat of white wash including scaffolding arrangement, trestles, ladders complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 4 above but two coat of white wash on wall surface, complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of Existing Treatment and applying two coats of oil bound distemper over one coat wall care putty complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old decorated wall surfaces and applying one coat of exterior grade emulsion paint as per manufacturer instruciton complete all as specified and directed by Engineer-in-Charge.
M&L for Preparation of old wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted surfaces of steel of any description over 10cm width or grith and applying one coat of synthetic enamel paint, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted surfaces of steel of any description over 10cm width or grith and applying one coat of aluminum paint, complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment from internal surfaces of walls or a part thereof (In Patches ), area exe 1.00 Sqm but not exceeding 3.00 Sqm, which is damage due to seepage or any other reason & preparing and levelling the disturbed surfaces by using wall care putty to obtain even and smooth wall surfaces of that portion and using sand paper and than applying two coats of oil bound distemper over a coat of primer, including scaffolding arrangement, trestles, ladders complete all as specified and directed by Engineer-in-Charge.
M&L for complete removal of existing treatment from internal surfaces of walls or a part thereof (In Patches ), area exceeding 3.00 Sqm but not exceeding 5.00 Sqm , which is damage due to seepage or any other reason & preparing and levelling the disturbed surfaces by using wall care putty to obtain even and smooth wall surfaces of that portion and using sand paper and than applying two coats of oil bound distemper over a coat of primer,including scaffolding arrangement, trestles, ladders complete all as specified and directed by Engineer-in-Charge.
Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engineer-in-Charge.
M&L for 15 mm thick cement plaster in cement mortar 1:6 on brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for 5mm thick rendering in CM 1:3 on ceiling and finished fair even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for preperation of old decorated surfaces of wall and applying one coat of cement base paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparing of new plastered or unplastered surfaces of ceiling and applying three coats of White wash, complete all as specified and directed by Engineer-in-Charge.
Preparation of newly plastered surface of walls and apply three coats of white wash complete all as specified and directed by Engineer-in-Charge.
M&L for Preparing new plastered or unplastered surfaces of wall and applying two coats of oil bound distemper over including one coat of birla white putty on whole surface complete all as specified and directed by Engineer-in-Charge.
Hacking out old broken glass any thicknesssize and quality from wooden/steel frames etc complete all as specified and directed by Engineer-in-Charge.
S&F sheet glass ordinary quality, 3 mm thick and glazing with oil putty in square n. exc. 0.50 Sqm in each pane complete all as specified and directed by Engineer-in-Charge.
S&F 3 mm figured glass, pin head type and glazed with oil putty in sqm n exc 0.50 Sqm in each pane complete all as specified and directed by Engineer-in-Charge.
S&F in repair SS curtain rod of 25 mm dia , with fixing brackets, side knobs etc (S S / any pattern) complete all as specified and directed by Engineer-in-Charge.
S&F as in repair corner sheet glass shelf assemble consisting of 5.5mm thick sheet glass shelf with chromium plated bracket guard and railing complete all as specified and directed by Engineer-in-Charge.
S&F in repair ss toilet paper holder complete all as specified and directed by Engineer-in-Charge.
S&F in repairs plastic WC seat cover white/ off white closed pattern with flat bottom end cover and mild steel CP hinging device complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, CP health faucet alongwith 1.00 to 1.50 meter good quality SS flexible connection pipe suitable for 15mm bore pipe, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets of 10 litre capacity, complete all as specified and directed by Engineer-in-Charge.
S&F in repair Vitreous china wash down water closet pan (pedestal pattern) ,including connecting to drain (or outgoing pipe), fix with white cement, white/ off white complete all as specified and directed by Engineer-in-Charge.
S&F in repair, vitreous china wash hand basin of size 550x400mm , white flat back , including waste coupling of PTMT 32 mm and waste pipe, 02 no of bracket and bolt complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, sink mixing valve 15mm dia, Hot and Cold CP brass fancy including joints to steel pipe or unions , including fittings, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, mixing valve 15mm dia, Hot and Cold CP brass fancy including joints to steel pipe or unions for centre hole wash hand basin , including fittings, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, wall mixing valve Hot and Cold water Screwed Down for iron pipe 15mm dia CP brass fancy including joints to steel pipe or unions , including fittings for, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, Brass chromium plated shower rose 125mm size with arm, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs, CP waste coupling 32/40 mm dia suitable for wash hand basin or kitchen sink complete all as specified and directed by Engineer-in-Charge.
S&F in repair staianless plate rack made of 0.8 mm thick stainless steel sheet of size 750 mm x 900 mm x 210mm consisting of 3 shelf for bowls and one shelf for keeping six nos of big utensil and seven nos of small utensils divided by 10 mm dia stainless steel hollow pipe @ 60 mm centre to centre complete all as specified and directed by Engineer-in-Charge.
S&F in repair cabinate mirror size 400x500 mm complete all as specified and directed by Engineer-in-Charge.
S&F In repair 40/50 mm dia cup board knobs fixed with nut, screw and washer of aluminum complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premices complete all as specified and directed by Engineer-in-Charge.
M&L for coloured glazed ceramic tiles in vertical surfaces 300x200x7mm/450x300x7mm thick set and jointed in cement slurry and pointed in white or coloured cement to match laid over & including 15mm thick cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for Vitrified Ceramic tiles, light shade, 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. laid over 15mm thick screed bed of CM (1:6) , set and jointed in neat cement slurry @ 3.00 kg per Sqm and pointed in white or coloured cement to match the shade of tile, complete all as specified and directed by Engineer-in-Charge.
M&L for Vitrified Ceramic tiles, light shade, 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting etc. over 10 mm thick CM (1:4) , set and jointed in neat cement slurry @ 3.00 kg per Sqm and pointed in white or coloured cement to match the shade of tile complete all as specified and directed by Engineer-in-Charge.
M&L for Non skid ceramic tiles, light shade, 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.11 sqm not exceeding 0.18, in floors etc. laid over 15mm thick screed bed of CM (1:6), set and jointed in neat cement slurry @ 3.00 kg per Sqm and pointed in white or coloured cement to match the shade of tile, complete all as specified and directed by Engineer-in-Charge.
M&L for Non skid ceramic tiles, light shade, 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.11 sqm not exceeding 0.18, in skirting etc. over 10 mm thick CM (1:4) , set and jointed in neat cement slurry @ 3.00 kg per Sqm and pointed in white or coloured cement to match the shade of tile, complete all as specified and directed by Engineer-in-Charge.
Disconnectiong existing tanks of capacity exc 500 & not exc 1000 Ltrs, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and re-fixing in position including cleaning and removing all the scale and dirt, etc from tank and from months of circulating pipes etc complete all as specified and directed by Engineer-in-Charge.
S&F in repairs for stainless steel door stopper 150mm long with double legged rubber bushes at the end complete all as specified and directed by Engineer-in-Charge.
S&F in repair 4.8 mm thick sheet glass ordinary quality and glazing with aluminium glazing clips & EPDM beading in square exc 0.5 sqm in each pane complete all as specified and directed by Engineer-in-Charge.
M&L for running welding in repairs including cleaning and preparing surfaces for welding thickness of metal to be welded not exc 6mm such as MS butt hinges to MS frame, broken steel windows or ventilators, iron doors and similar work complete all as specified and directed by Engineer-in-Charge.
Dismantling of stone slab and tiles laid bedded and pointed in any mortar of any discription or thickness in floors complete all as specified and directed by Engineer-in-Charge.
S&F of granite (of any type) tiles 12 mm thick machine cut ,bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete as in cooking plateform complete all as specified and directed by Engineer-in-Charge.
Rounding to edges of stone slabs one edge such as in steps cooking platform and other similar situations complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of switch piano flush type 5/6 Amps SP one way complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of switch piano type 15/16 Amps SP one way complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of universal socket outlet 2-in-1 (multipurpose) 5pin 6/16 Amps flush mounted type complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of switch socket combination 5-in-1, 6/16 Amps flush type complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of switch socket combination 2-in-1, 6 Amps flush type including PVC gang box complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of switch socket combination 5-in-1, 6/16 Amps flush type, including PVC gang box complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of lamp holder Angle/Batten type bakelite insulated body with back plate suitable for batten fitting complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Electric Bell (Buzzer) AC, 230 volts single phase complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Bell Electric Ding Dong type 230 volts single phase complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of old unserviceable plug top 15/16 Amps for Geyser complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of electronic fan regulator minimum 4 stepped Switch type suitable for ceiling fan of 1200/ 1400mm sweep as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for white cover plate with frame, 1 module complete all as specified and directed by Engineer in Charge.
S&F in replacement for white cover plate with frame, 2 module complete all as specified and directed by Engineer in Charge.
S&F in replacement for white cover plate with frame, 3 module complete all as specified and directed by Engineer in Charge.
S&F in replacement for white cover plate with frame, 4 module complete all as specified and directed by Engineer in Charge.
S&F in replacement for white cover plate with frame, 6 module complete all as specified and directed by Engineer in Charge.
S&F in replacement for white cover plate with frame, 8 module (vertical) complete all as specified and directed by Engineer in Charge.
S&F in replacement for white cover plate with frame, 12 module complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Switch modular type, 1Module, 6 Amps one way complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Switch modular type 1M 6 Amp 2-waycomplete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Bell push modular type 1M 5/6 Amp complete all as specified and directed by Engineer in Charge.
S&F in replacement of Socket outlet modular type 2M, 5 pin, 6 Amp complete all as specified and directed by Engineer in Charge.
S&F in replacement of Switch modular type, 16 Amp complete all as specified and directed by Engineer in Charge.
S&F in replacement of Socket Outlet modular type 2M combined shuttered, 5 pin 6/16 Amp complete all as specified and directed by Engineer in Charge.
S&F in replacement of Electronic fan regulator, modular type 2M, 4 steps, complete all as specified and directed by Engineer in Charge.
S&F in replacement of Blank plate modular type 1M, complete all as specified and directed by Engineer in Charge.
S&F PVC casing and capping 20mm in size suitable for wiring complete all as specified and directed by Engineer-in-Charge.
S&F wall mounted LED Integrated batten T5 20Watt -4ft white , 6500K, indoor decorative PVC extruded T5 LED batten- Integrated type in replacement of old unsv existing 36/40Watt FTL fitting any type, complete all as specified and directed by Engr-in-Charge.
S&F wall mounted LED Integrated batten T5 10Watt -2ft white , 6500K, indoor decorative PVC extruded T5 LED batten- Integrated type in replacement of old unsv existing 18/14 watt FTL fitting any type, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of old unserviceable wall light fixture any type with Wall mounting fitting City-4,Decorative wall light fixture made up of Polycarbonate, of B-22 base suitable for lamps upto 15 Watt complete all as specified and directed by Engineer in Charge.
S&F in replacement LED 10 watt white Bulk head in engineering plastic housing with clear prismatic including required LED bulb and all accessories connecting up twisted flexible copper conductor cable of suitable size of 230 V, 50 Hz complete all as specified and directed by Engr-in-Charge.
S&F surface mounting Round/ Square shaped LED downlighter 6 Watt any type complete with including new fliexble wire as required on site and including taking down of old unsv existing ceiling light fitting complete all as specified and directed by Engineer-in-Charge.
S&F surface mounting Round/ Square shaped LED downlighter 12 Watt any type complete with including new fliexble wire as required on site and including taking down of old unsv existing ceiling light fitting complete all as specified and directed by Engineer-in-Charge.
S&F in replacement top cover 3 mm thick plastic/laminated sheet of various sizes with screw and cup washer including connection of switch, socket, regulators including connection through required size copper conductor PVC unsheathed complete all as specified and making good to disturbed surface as existing finishes complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB TP, 415V, any type, 200 Amps with breaking capacity 36 kA of any description including providing new lugs & thimbles of required size complete all as specified and directed by Engineer in Charge.
S&F in replacement MCB TP 63 Amps 415 volts, 'C' Series 10 KA complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCB SPN 63 Amps C curve complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCB SPN 40 Amps C curve complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCB SP 6 to 32 Amps C curve complete all as specified and directed by Engineer-in-Charge.
Taking down old Submain wiring any type , keeping away from site and M&L for submain wiring PVC insulated FRLS single core with stranded copper cable of size 4 Sqmm in 2 runs and 4 Sqmm one run for earth drawing through capping and casing 20 mm dia complete all as specified and directed by Engineer-in-Charge.
Taking down old Submain wiring any type , keeping away from site and M&L for submain wiring PVC insulated FRLS single core with stranded copper cable of size 6 Sqmm in 2 runs and 6 Sqmm one run for earth drawing through existing PVC concealed conduit 25 mm dia conduit complete all as specified and directed by Engineer-in-Charge.
Taking down old Submain wiring any type , keeping away from site and M&L for submain wiring PVC insulated FRLS single core with stranded copper cable of size 10 Sqmm in 2 runs and 6Sqmm one run for earth drawing through existing PVC concealed conduit 25 mm dia conduit complete all as specified and directed by Engineer-in-Charge. Notes for Srl item No.92 to 94:- (a) Two runs of main cable and one run of earth cable all together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
Notes for BoQ :- The rate quoted by the tenderer shall inclusive of the provision as mentioned under Note Ser No. (i) to (v) here-in-after the tenderer are advice to keep in mind these provisions while quoting his rates. 1. The tenderer has to bring the consumable material which loose their identity like synthetic enamel paint, OBD, cement base paint, plastic emulsion paint, Lime, exterior emulsion paint, etc well in advance along with original purchase voucher as per sample approval by as under. These material when brought by the tenderer shall be checked by BOO as detailed by GE and shall be kept in custody of concerned JE and rep of contractor with double look arrangement in store room. The material shall be issued on daily basis as per site requirement. A Pucca bond register shall be maintained by the contractor showing total quantity in hand, quantity issued and quantity incorporated in the particular quarter which shall be initiated by both the party i.e JE and rep of contractor:- (i) 25% of total reqd material as per CA provision within 10 days from the date of commencement of work. (ii) 25% of the total reqd material as per CA provision within 03 month from date of commencement of the work or earlier as per site requirement. (iii) 25% of the total reqd material as per CA provision within 06 months from the date of commencement of the work or earlier as per site requirement. (iv) Balance 25% of the reqd material as per CA provision within 02 month before the date of completion or earlier as per site requirement. (v) Engineer-in-charge/ JE shall ensure the above provision is followed before commencement of the work at site.
2. The Qtr for welcome maintenance shall be handed over to contractor as per vacation/ allotment of Qtr and users requirement. After handing over the Qtr, the tenderer has to complete the work within 07 days for normal repair and 15 days for major repair as decided by Engineer-in-Charge which includes Sunday/ holiday. Necessary panel recovery shall be made Rs. 1000 per day if the qtr not handed over within the above stipulated time after handing over of Qtr. A Pucca bond register shall be maintained at site showing Qtr No, date of vacation, date of handing over the Qtr, proposed date of completion and actual date of completion which shall be got signed by the Engr-in-Charge. 3. Every stage like preparation of surfaces, first coat, second coat/ final coat of finishes shall be got passed by Engineer-in-Charge. 4. The replaced fitting of fixture which have been replaced under this contract shall be intimated to BSO for incorporating in inventory before handing over the Qtr. 5. The contractor shall cover all the furniture item while doing painting and other repair work, clean the entire house including paint marks on joinery items, glass panes, cupboard etc with entire satisfaction of Engineer-in-Charge before handing over the key back after welcome maintenance. 6. All the above documents shall be produced for verification at the time of payment of each RAR/Bill.
Notes for BoQ:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
Chaudhary Constructions
A N BUILDERS
HANUMAN BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .