Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.1 LQualified Make: Zktechno
Model: ZKTECNO & ZK-D1065S 25A TILAK NAGAR 2ND BHADWASIYA JODHPUR JODHPUR CITY RAJASTHAN 342006 | JODHPUR | RAJASTHAN | 342006 | Make: Zktechno
Model: ZKTECNO & ZK-D1065S | L1 | Qualified | |
| 2 | L2₹2.1 L+₹4,204 (2.02%)Qualified Make: NA
Model: FUTURE , FUTURE 9Z 2 RANA SAMAY SINGH DURG MAHARANA PRATAPGARH KAKROLA VILLAGE SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | Make: NA
Model: FUTURE , FUTURE 9Z | L2 | Qualified | |
| 3 | Disqualified Make: Octopus
Model: L12-3012/300T 502 FIFTH FLOOR RISHABH CORPORATE TOWER 16 COMMUNITY CENTRE OPP KARKARDOOMA METRO STATION KARKARDOOM EAST DELHI INDIA | Make: Octopus
Model: L12-3012/300T | - | Disqualified | |
| 4 | Disqualified Make: RELIANCE
Model: RELIANCE ELECTRONICS, RE-MP-VIII+ D 1 2 MIDC AMBAD NASHIK MAHARASHTRA 422010 | NASHIK | MAHARASHTRA | 422010 | Make: RELIANCE
Model: RELIANCE ELECTRONICS, RE-MP-VIII+ | - | Disqualified | |
| 5 | Disqualified Make: Security Defence Systems
Model: Security Defence Systems Model SK-CHECK-888 BADDI SOLAN HIMACHAL PRADESH 173205 INDIA | SOLAN | HIMACHAL PRADESH | 173205 | Make: Security Defence Systems
Model: Security Defence Systems Model SK-CHECK-888 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
13 Jul 2018, 10:00 amClosed
door frame metal detector dfmd security metal detector Experience with Gov. Required 3 Year (s) Door Frame Metal Detector Dfmd Security Metal Detector ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values TYPE/CAPACITY Type of usage Outdoor Indoor
Outdoor Detection Zones Multiple Zone Single Zone
Multiple Zone Function Detects Ferrous
Non- Ferrous and alloy metals concealed in the body of a person when passsed through the arch way - Number of Horizontal Detection Zones covering full Height 8 - Capacity/throughput rate (person/min) 20 or more - False Alarm rate (%) 2 - DIMENSIONS/WEIGHT Passage Height 2100 - Passage Breadth 760 - Passage Width 600 - Weight of the equipment Not more than 80 Kg - DOOR FRAME Construction of Door Light weight
rigid
1/6 CONSTRUCTION Frame (Walk-through Arch) laminated side panels and cross piece with ABS plastic boots for panel protection Material of Walk- through Arch POLYCARBONATE - Provided with base wheels for easy mobility false - Provided with a floor panel to attach both side panels to give stability & rigidity to the structure true - Ramp over the floor panel - Covered with synthetic carpet for long life false - Water proof true - Weather proof true - DETECTION Metals detectable Ferrous
Non-Ferrous
Ferrite & Alloys - Uniform Detection from top to bottom Yes - Capable of Metal Detection in all orientations Yes - Detect multiple objects of various size
weight and shape in all the zones simultaneously from head to toe Yes - Capable of Metal Detection in walking speed of interception Yes - Performance independent of the speed of person passing through Yes - ALARM/INDICATION DISPLAY Audio-Visual indication on detection at side panels and control panel Yes - Audible Alarm on detection with adjustable volume Yes - Bar Display to indicate Metal location w.r.t. Height on person Yes - 2/6 Audio-Visual Low Battery indication Yes - Back-lit Display LED - SENSITIVITY Operational Frequencies User selectable - Number of User Selectable frequencies 8 - Adjustable Sensitivity Yes - Number of Sensitivity Levels/Steps 4 - Uniform Sensitivity in all zones Yes - Calibration Both manual and Auto Calibration - SECURITY Provision to secure access to the control unit by a pass word protected alpha numeric keypad Yes - Re-setting after alarm condition Re-set itself (auto) within 3 Seconds - Walk/Stop indicator for traffic control Yes - Control Panel Easy accessible control panel
with modular design and standard plugs and connectors. Adjustable controls should only be activated on insertion of a removable key and or by password. - User friendly self- testing diagnostics to identify faulty condition Yes - INTERFERENCE SUPPRESSION REJECTION Automatic synchronization for DFMDs: Do not interfere with adjacent installed DFMDs located close to each other upto a distance of: 1 - Static Metal Compensation: Not affected by heavily reinforced floors/roof tops/walls Yes - High discrimination Yes - 3/6 between small masses and personal metallic objects Not affected by external RF transmission and EMI (Electro Magnetic Interference) Yes - Not affected by by interference
which is mains-borne or radiated by external source Yes - Not affected by the operation of equipment such as radio
Mobile phones
walkie-talkie sets
X-ray monitors etc within a distance of one meter from the archway. Yes - Not affected by moving metallic items such as trolleys
opening closing of metallic gate etc
one meter away from the archway Yes - HEALTH & SAFETY Harmless to wearers of pacemakers
defibrillators or other vital support systems
pregnant women and magnetic storage media (floppy disks
audio cassettes
video cassettes and similar) Yes - Not affected by infrared
ultraviolet
electromagnetic or RF radiation Yes - Conform to international security standards of Safety Radiation Yes - Harmless to magnetic media
electronic devices
Film safe and Data safe Yes - ENVIRONMENTAL Operating Temperature Range (Degree C) Minus 20 to Plus 55 Degree C - Operating Humidity - Non condensing (RH) 90 - 4/6 (%) POWER SUPPLY BATTERY Source of Power Operated by AC mains supply and alternatively by rechargeable battery - Power Supply 100 to 260 VAC - Battery Standard UPS - Battery Back-up in full function (hours) 6 - ACCESSORIES One Standard Test Piecec for each machine for testing during commissioning maintenance Inclusive in the scope of supply - Training tools- Charts
slides
training brochure
training work model
blowup diagram
video films on demonstration and use etc. Inclusive in the scope of supply - Technical manual giving full description of the item
user's handbook and literature on preservation maintenance
procedure for packing
handling
transportation
storage and battery replacement Yes - Practical training At least one day in each quarter of the year continuing during warranty period - Availability of Spares for a period of 7 years after the warranty period true - Ruggedized polypropylene shock proof container compliant to IP 65 or better for safe transportation of the equipment true - WARRANTY Warranty (Years) 3 - CERTIFICATION Availability of Test Report from NABL/ILAC true - 5/6 accredited or Central Government Lab to prove conformity of products to the specification Test Report Number & Date 222 - Name & address of the Lab BOMBAY - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Nupur Jain 721145
AIR FORCE STATION SALUA 2 15 Required No ePBG Required No
298050
GEM/2018/B/42295
door frame metal detector dfmd security metal detector
15 days
West Bengal; Medinipur West
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| door frame metal detector dfmd security metal detector Experience with Gov. Required 3 Year (s) Door Frame Metal Detector Dfmd Security Metal Detector ( 2 ) Technical Specifications Specification Specification Name Values Allowed Values TYPE/CAPACITY Type of usage Outdoor Indoor | - | - | - |
| Outdoor Detection Zones Multiple Zone Single Zone | - | - | - |
| Multiple Zone Function Detects Ferrous | - | - | - |
| Non- Ferrous and alloy metals concealed in the body of a person when passsed through the arch way - Number of Horizontal Detection Zones covering full Height 8 - Capacity/throughput rate (person/min) 20 or more - False Alarm rate (%) 2 - DIMENSIONS/WEIGHT Passage Height 2100 - Passage Breadth 760 - Passage Width 600 - Weight of the equipment Not more than 80 Kg - DOOR FRAME Construction of Door Light weight | - | - | - |
| rigid | - | - | - |
| 1/6 CONSTRUCTION Frame (Walk-through Arch) laminated side panels and cross piece with ABS plastic boots for panel protection Material of Walk- through Arch POLYCARBONATE - Provided with base wheels for easy mobility false - Provided with a floor panel to attach both side panels to give stability & rigidity to the structure true - Ramp over the floor panel - Covered with synthetic carpet for long life false - Water proof true - Weather proof true - DETECTION Metals detectable Ferrous | - | - | - |
| Non-Ferrous | - | - | - |
| Ferrite & Alloys - Uniform Detection from top to bottom Yes - Capable of Metal Detection in all orientations Yes - Detect multiple objects of various size | - | - | - |
| weight and shape in all the zones simultaneously from head to toe Yes - Capable of Metal Detection in walking speed of interception Yes - Performance independent of the speed of person passing through Yes - ALARM/INDICATION DISPLAY Audio-Visual indication on detection at side panels and control panel Yes - Audible Alarm on detection with adjustable volume Yes - Bar Display to indicate Metal location w.r.t. Height on person Yes - 2/6 Audio-Visual Low Battery indication Yes - Back-lit Display LED - SENSITIVITY Operational Frequencies User selectable - Number of User Selectable frequencies 8 - Adjustable Sensitivity Yes - Number of Sensitivity Levels/Steps 4 - Uniform Sensitivity in all zones Yes - Calibration Both manual and Auto Calibration - SECURITY Provision to secure access to the control unit by a pass word protected alpha numeric keypad Yes - Re-setting after alarm condition Re-set itself (auto) within 3 Seconds - Walk/Stop indicator for traffic control Yes - Control Panel Easy accessible control panel | - | - | - |
| with modular design and standard plugs and connectors. Adjustable controls should only be activated on insertion of a removable key and or by password. - User friendly self- testing diagnostics to identify faulty condition Yes - INTERFERENCE SUPPRESSION REJECTION Automatic synchronization for DFMDs: Do not interfere with adjacent installed DFMDs located close to each other upto a distance of: 1 - Static Metal Compensation: Not affected by heavily reinforced floors/roof tops/walls Yes - High discrimination Yes - 3/6 between small masses and personal metallic objects Not affected by external RF transmission and EMI (Electro Magnetic Interference) Yes - Not affected by by interference | - | - | - |
| which is mains-borne or radiated by external source Yes - Not affected by the operation of equipment such as radio | - | - | - |
| Mobile phones | - | - | - |
| walkie-talkie sets | - | - | - |
| X-ray monitors etc within a distance of one meter from the archway. Yes - Not affected by moving metallic items such as trolleys | - | - | - |
| opening closing of metallic gate etc | - | - | - |
| one meter away from the archway Yes - HEALTH & SAFETY Harmless to wearers of pacemakers | - | - | - |
| defibrillators or other vital support systems | - | - | - |
| pregnant women and magnetic storage media (floppy disks | - | - | - |
| audio cassettes | - | - | - |
| video cassettes and similar) Yes - Not affected by infrared | - | - | - |
| ultraviolet | - | - | - |
| electromagnetic or RF radiation Yes - Conform to international security standards of Safety Radiation Yes - Harmless to magnetic media | - | - | - |
| electronic devices | - | - | - |
| Film safe and Data safe Yes - ENVIRONMENTAL Operating Temperature Range (Degree C) Minus 20 to Plus 55 Degree C - Operating Humidity - Non condensing (RH) 90 - 4/6 (%) POWER SUPPLY BATTERY Source of Power Operated by AC mains supply and alternatively by rechargeable battery - Power Supply 100 to 260 VAC - Battery Standard UPS - Battery Back-up in full function (hours) 6 - ACCESSORIES One Standard Test Piecec for each machine for testing during commissioning maintenance Inclusive in the scope of supply - Training tools- Charts | - | - | - |
| slides | - | - | - |
| training brochure | - | - | - |
| training work model | - | - | - |
| blowup diagram | - | - | - |
| video films on demonstration and use etc. Inclusive in the scope of supply - Technical manual giving full description of the item | - | - | - |
| user's handbook and literature on preservation maintenance | - | - | - |
| procedure for packing | - | - | - |
| handling | - | - | - |
| transportation | - | - | - |
| storage and battery replacement Yes - Practical training At least one day in each quarter of the year continuing during warranty period - Availability of Spares for a period of 7 years after the warranty period true - Ruggedized polypropylene shock proof container compliant to IP 65 or better for safe transportation of the equipment true - WARRANTY Warranty (Years) 3 - CERTIFICATION Availability of Test Report from NABL/ILAC true - 5/6 accredited or Central Government Lab to prove conformity of products to the specification Test Report Number & Date 222 - Name & address of the Lab BOMBAY - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Nupur Jain 721145 | - | - | - |
| AIR FORCE STATION SALUA 2 15 Required No ePBG Required No | - | - | - |
Exempted
13 Jul 2018
6 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_298050.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .