Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC NO 1A 1 SHALOM VALLUVAR STREET SIVANANDHA COLONY COIMBATORE TAMIL NADU 641 012 | COIMBATORE | TAMIL NADU | 641012 | ₹29.0 L Quoted ₹30.0 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹37.5 L+₹7.5 L (24.9%)Rejected-AOC | ₹37.5 L+₹7.5 L (24.9%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹42.9 L+₹12.9 L (43.0%)Rejected-AOC | ₹42.9 L+₹12.9 L (43.0%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹43.6 L+₹13.6 L (45.5%)Rejected-AOC KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | ₹43.6 L+₹13.6 L (45.5%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹44.0 L+₹14.0 L (46.6%)Rejected-AOC | ₹44.0 L+₹14.0 L (46.6%) | L5 | Rejected-AOC Rejected |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
4 Sept 2024, 6:00 pmClosed
GE Tirunelveli
Garrison Engineer Naval Post Base Vijayanarayanam Tirunelveli -627119
SPECIAL REPAIRS TO REPLACEMENT OF CONVENTIONAL EARTHING WITH CHEMICAL EARTHING AND OLD FEEDER PILLARS AT RAMNAD UNDER GE TIRUNELVELI
2024_MES_663173_1
GE/TVL/8384/E8 of 2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Ramnad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹78,000
Yes
21 Nov 2024
1 Jul 2024
6 Sept 2024
1 Jul 2024
4 Sept 2024
15 Jul 2024
2 Jul 2024 - 11 Jul 2024
Amount
Supply , erection and testing of maintenance free chemical earthing by auguring & installation of copper bonded rod of dia 20 mm , length 3m , made of low carbon high tensile steel with copper plating (250+ microns) for preventing external corrosion, top end connected with copper plated welded bus bar terminal of dimension 150mm x 50mm x 6 mm complete conforming to IS : 3043 - 1987 and filling with back fill compound, carbon based, high conductive 'Conductolite' with resistivity < 0.5 ohm-metre (In dry conditions) & resistivity non-moisture dependant,pH Value : 8.0 - 9.0, electronic & ionic conduction, less susceptible to shrinkage,with hygroscopic & corrosion resistive properties and covering with heavy duty polyplastic earth pit chamber cover complete all as specified and directed Make : M/s Ashlok Safe Earthing Electrode Limited or any make as approved by GE.
Labour Charges for removal of old earthing complete including GI Strip , GI Earth Plate including demolition and removal of chambers complete all as specified and directed by Engr-in-charge. Note : Excavation shall be measured and paid separately under respective item
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for laying pipes and getting out in any type of soil, complete all as specified and directed by Engr-in-charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified and directed by Engr-in-charge.
Supply , installation, testing and commissioning of outdoor LT feeder pillar box in replacement , CPRI Approved , factory fabricated, powder coat painted having thickness not less than 100 microns . The doors shall be provided with suitable gasket and latch, including necessary PCC foundation for erecting the panel board. Feeder pillar shall be suitable to accommodate the following as specified and as directed.:- OUTER SHELL : The outer shall be made out of 3.15 mm thick CRCA sheet &MS angle section 50x50x6 mm frame, factory fabricated with front & back open able, double door system lockable/open able by keys from both sides having chromium plated locks. ‘U’ type gasket shall be used to make the outer shell completely vermin proof. The bottom of the outer shell contains a detachable plate of thickness 3.15 mm powder coated having provision for entry of armoured cable of adequate size with glands. The outer shell shall be powder coated Siemens grey structural RAL 7032 shade. INNER SHELL : inner shell shall be made out of 2.0 mm thick CRCA sheet duly compartmentalized for each control gear, front & back open able single door system lockable / open able by keys from both sides having chromium plated locks (2 Nos in each compartment),having louvers & air vent gasket for natural flow of air. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size ‘F’ class insulator made on non hygroscopic, non combustible , track resistant, high strength FRP/SMC/DMC material at an interval not more than 500mm throughout the length of the TPN bus bar for the following panels:-
The bus bar chamber comprising of high conductivity aluminium bus bar of capacity 500 Amps three phase and half the capacity for neutral. INCOMING (a) MCCB 415 V,250 A, 4 pole breaking capacity 25 KA- 01 Nos. (b) Manual Change over switch 250 A - 01 Nos. (c) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard practice ---1 Job OUT GOING (a) MCCB 160 A, 415V , 4 pole , breaking capacity 16 KA - 01 Nos (b) MCCB 125 A, 415V ,4 pole , breaking capacity 16 KA - 02 Nos (c) MCCB 63 A, 415V ,4 pole , 10kA C Curve - 02 Nos (d) MCB 25A, 415V , TPN , 10kA C Curve - 03 Nos (e) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard practice ---5 Job
All as per Item No.5 above and the following: The bus bar chamber comprising of high conductivity aluminium bus bar of capacity 300 Amps three phase and half the capacity for neutral. INCOMING (a) MCCB 415 V,160 A, 4 pole breaking capacity 16 KA- 01 Nos. (b) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard practice ---1 Job OUT GOING (a) MCCB 63 A, 415V , 4 pole , breaking capacity 16 KA - 02 Nos (b) MPCB,Rating -13 A suitable for 7.5 HP motor, 415V -4 Nos (c) DOL Starter suitable for motor 7.5 HP with Control MCB ,main contactor, auxiliary Contactor, Push Button (stop & start Functioning), over load relay, single phase preventer- 4 nos (d) MCB 25A, 415V , TPN , 10kA C Curve - 03 Nos (e) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard practice ---6 Job
All as per Item No.5 above and the following: The bus bar chamber comprising of high conductivity aluminium bus bar of capacity 200 Amps three phase and half the capacity for neutral. INCOMING (a) MCCB 415 V,63 A, 4 pole breaking capacity 16 KA- 01 Nos. (b) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard practice ---1 Job OUT GOING (a) MCCB 40 A, 415V ,4 pole , breaking capacity 16 KA - 01 Nos (b) MPCB,Rating -10 A suitable for 7.5 HP motor, 415V -4 Nos (c) DOL Starter suitable for motor 7.5 HP with Control MCB ,main contactor, auxiliary Contactor, Push Button (stop & start Functioning), over load relay, single phase preventer- 4 nos. (d) MCB 25 A, 415V , TPN , 10kA C Curve - 03 Nos (e) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard practice ---5 Job
All as per Item No.5 above and the following: The bus bar chamber comprising of high conductivity aluminium bus bar of capacity 200 Amps three phase and half the capacity for neutral. INCOMING (a) MCCB 415 V,63 A, 4 pole breaking capacity 16 KA- 01 Nos. (b) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard practice ---1 Job OUT GOING (a) MCCB 40 A, 415V ,4 pole , breaking capacity 16 KA - 01 Nos (b) MPCB,Rating -10 A suitable for 3 HP motor, 415V -2 Nos (c) DOL Starter suitable for motor 3 HP with Control MCB ,main contactor, auxiliary Contactor, Push Button (stop & start Functioning), over load relay, single phase preventer- 2 nos. (d) MCB 25 A, 415V , TPN , 10kA C Curve - 02 Nos (e) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard practice ---3 Job
All as per Item No.5 above and the following: The bus bar chamber comprising of high conductivity aluminium bus bar of capacity 200 Amps three phase and half the capacity for neutral. INCOMING (a) MCCB 415 V,63 A, 4 pole breaking capacity 16 KA- 01 Nos. (b) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard practice ---1 Job OUT GOING (a) MCCB 40 A, 415V ,4 pole , breaking capacity 16 KA - 01 Nos (b) MPCB,Rating -10 A suitable for 3 HP motor, 415V - 02 Nos (c) DOL Starter suitable for motor 3 HP with Control MCB ,main contactor, auxiliary Contactor, Push Button (stop & start Functioning), over load relay, single phase preventer- 2 nos. (d) MPCB,Rating -10 A suitable for 1 HP motor, 415V - 02 Nos (e) DOL Starter suitable for motor 1 HP with Control MCB ,main contactor, auxiliary Contactor, Push Button (stop & start Functioning), over load relay, single phase preventer- 2 nos. (f) MCB 25 A, 415V , TPN , 10kA C Curve - 02 Nos (g) Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard practice ---3 Job
PHEJAYS AGENCIES (BID ID -3069043)
M/S Mist Hills Enterprices (BID ID -3074987)
SUPER COOL (BID ID -3066307)
THIRUMURUGAN ENTERPRISES (BID ID -3080707)
sri manikandan enterprises (BID ID -3080799)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .