Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹76.2 L+₹4.9 L (6.92%)Rejected-AOC FLAT NO 203 GH 5 SECTOR 27 PANCHKULA 134116 HRY | PANCHKULA | HARYANA | 134116 | L2 | Rejected-AOC Other than lowest bdder |
Tender Value
Refer Docs
EMD Value
₹1.8 L
Closing Date
30 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Chandigarh
HQ CWE (AF) Chandigarh PIN-160003
IMPROVEMENT TO CERTAIN SMQs AT AF STN HIGHGROUNDS (PHASE-I)
2024_MES_636398_2
CWE/AF CHD/CHD/T-28/2023-24
Open Tender
Civil Works
Item Rate
270 days
Chandigarh
As per NIT
8 documents required · 8 mandatory
₹1,000
AGE(I)(AF) Highgrounds
₹1.8 L
24 Jul 2024
21 Feb 2024
6 Apr 2024
21 Feb 2024
30 Mar 2024
16 Mar 2024
Amount
Taking down chowkats or frames with shutters (without taking off shutters from the frame) area not exc. 1.5sqm each complete all as specified and as directed.
All as per item No 1 here-in-before but area exc.1.50sqm & not exc 4.00 sqm each
Taking down shutters of any description having area not exc. 1sqm each d complete all as specified and as directed.
Taking down shutters of any description having area exc. 1sqm but not exc. 2sqm each complete all as specified and as directed.
Taking down shutters of any description having area exc. 1sqm but not exc. 2sqm each & refixing in the same opening after easing & adjusting complete all as specified and as directed.
S&F 125 x 60mm pressed steel frames 1.25mm thick for doors, windows with one or more rebates incl necessary fixing lugs, hinges, lock strike plate etc.complete all as specified and as directed.
S&F 105x60mm pressed steel frames 1.25mm thick for doors,windows with one or more rebates incl necessary fixing lugs, hinges, lock strike plate etc.complete all as specified and as directed.
S&F factory made solid PVC single door frames of size 50 x 47mm made out of 5mm plain colour PVC Sheets reinforeced with MS Square tubbing in opening as per specification complete all as specified and as directed.
S&F rolled mild steel work as in door chowkats including hold fasts and tie rod etc confirming to Fe 410-W (Gde-E-250) quality-A complete all as specified & as directed.
S&F Mild steel plain black sheet 1.00m thick as in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnelsetc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. complete all as specified and as directed.
S&F 35mm thick 2nd class hard wood plane framed panelled shutter (two panel) with lock rail and panel of 9mm BWP/12mm veneered particle board with commercial veneered on both faces as specified & directed.. The size of rail and style as per IS 1003 (Part-1) Kiln seasoned and chemically pressure treated complete all as specified and as directed.
S&F 35mm thick glazed and Skelton shutter of 2nd class hardwood (Hollock) open rebated and prepared to receive glass, gauge etc.divided into squares with plain chamfered or rounded mitred and rebated sash bars any number, edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc. Size of members of shutters as specified in SSR Part-1 clause 8.20(a) complete all as specified and as directed.
S&F in repair Gun metal gate valve with iron wheel head screwed both ends for 15 mm dia bore of iron pipes complete all as specified and as directed.
S&F in repair Gun metal gate valve with iron wheel head screwed both ends for 20mm dia bore of iron pipes complete all as specified and as directed.
S&F Plain, solid, straight chowkats and frames of 2nd class hardwood, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
S&F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2 panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and as directed.
S&F flush shutters 25 mm thick solid core construction with block board core and plywood face panels commercial on both side duly provided with 6mm thick teakwood leaping on edge, complete all as specified and as directed.
S&F in repair Prelaminated particle board 18-19mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work as in selves complete all as specified and as directed.
S&F steel window or ventilator, fixed type, with glazing bars complete all as specified and as directed.
S&F Factory made box type steel windows with pintle hinges & 1 No 150mm long mild steel tower bolt, steel handle to each shutter, with glazing bars, dovetailed or welded etc with and including one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEAF/STD-185-2012 Sheets 1/2 & 2/2.
S&F Factory made box type steel window with pintle hinges & 2 Nos 150mm long mild steel tower bolts to each shutter and steel handle, without glazing bars, including Mild steel flat iron 12 x 3 mm for securing wire mesh, dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified and shown on Drawing No CEAF/STD-185-2012 Sheets 1/2 & 2/2.
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
S&F 300 mm size ordinay rat tail rod pattern MS door spring including roller and roller plate by means of welding complete all as specified and as directed.
S&F Stainless steel wire cloth. 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staple complete all as specified and as directed.
All as per item No 24 here-in-before but fixed in repairs complete all as specified and as directed.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty or fixed with wooden beads having area not exc 0.50sqm in each pane complete all as specified and as directed.
Hacking out old broken glass from metal frame or wooden frames incl punching or drilling out old glazing pins/spring clips of any area complete all as specified and as directed.
S&F mild steel butt hinges cold rolled medium weight of 100mm size complete all as specified and as directed.
M&L for providing cement concrete 1:2:4 type B1 as in roof kerbs or mud stops, slightly rounded or chamferred complete all as specified and as directed.
S&F double leged floor door stopper of over all length of cover plate 140 mm of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor complete all as specified and as directed.
M&L for providing cement concrete 1:2:4 type B1 as in seismic bands and other similar bands, plinth courses, string courses, bed plates and the like including weathering , slightly rounded or chamferred angles and throatimg complete all as specified and as directed.
S&F Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws (Size of hasp and staple in 100mm) complete all as specified and as directed.
S&F aluminium handles, cast type anodised, 150mm size complete all as specified and as directed.
S&F aluminium handles, cast type anodised, 100mm size complete all as specified and as directed.
S&F aluminium anodised barrel tower bolts of extruded section, 150mm long complete all as specified and as directed.
S&F 250 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of with bright bolt of extruded sections or cast aluminium alloy complete all as specified and as directed.
S&F contineous (piano hinges, mild steel, with width of flaps 30 mm when open, bright finish or electrogalvanised complete all as specified and as directed.
M&L for Preparation of new wooden surfaces of any description, not otherwise described, over 10 cm with or girth & applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparing of new steel surfaces of any description, not otherwise described, over 10 cm with or girth & applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F in repair curtain rod, mild steel chromium plated with fixing brackets (end/wall brackets and end caps etc), stops, roller etc complete all as specified and as directed.
M&L for running Welding in repairs, thickness of metal to be welded exc 6 mm but n.exc 9 mm with and including bevelling of edges as required complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins arches pillars etc complete all as specified and as directed.
M&L for brick work sub class “B” bricks straight or curveted in plan exc. 6mtr mean radius with old size bricks built in CM 1:6 complete all as specified and as directed.
All as per item No 43 here-in-before but except bricks complete all as specified and as directed.
Taking down cement plaster including racking out joints hacking for key scrubbing down with water complete all as specified and as directed.
M&L for rendering 10mm thick in cement mortar 1:3 as in ceiling finished the surface even & smooth without using extra cement complete all as specified and as directed.
M&L for Preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:6 as on brick walls finished the surface even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 as on brick walls finished the surface even & fair without using extra cement complete all as specified and as directed.
M&L for Preparation of new plastered/unplastered surfaces of wall and applying two coats of Acrylic distemper water based over a coat of primer complete all as specified and as directed.
M&L for Preparation of new plastered/unplastered wall surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed.
Demolition of cement concrete as in ground floors and in paving not exc 15cm thick below or above ground level complete all as specified and as directed.
Demolition of cement concrete of any description in any postion not otherwised specificaly provided as in first floor flooring, roof pading etc. complete all as specified and as directed.
M&L for cement concrete type C-2 1:3:6 (using 40mm graded stone aggregate) 75mm thick as in plinth protection finished even and smooth without using extra cement with and including filling the joints with mastic filling complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors aprons etc, laid beded and pointed in any mortar complete all as specified and as directed.
Dismantling floor, hearth or wall tiling, terrazzo toping/dado, including cement mortar bedding/backing and removing rubbish off the premises outside the MoD land, with and including preparation of disturbed surface area to receive backing coat/bedding layer for laying tiles etc complete all as specified and as directed.
M&L for coloured glazed ceramic tiles of size 300x450 x 7mm thick as in vertical surface and joint s grouted & pointed flush in white cement with pigment over and including 10 mm thick rendering in CM 1:3 complete all as specified and as directed.
M&L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement and admixture of pigment to match the shade of granite stone including grinding and polishing over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L for non skid coloured ceramic jointless tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick srceed bed in CM 1:6 complete all as specified and as directed.
M&L for machine cut Kota stone slab flooring 20-23 mm thick over and including 15mm thick screed in cm (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for Kota Stone Slab 20-23 mm thick as in riser of steps, skirting, dado and pillar etc laid over and including 10mm thick screed in cm (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for Providing precast cement concrete 1:2:4: type B-1(using 20mm graded stone aggregate) as in landings, cover slabs (for manholes), chullah hoods, chajja, water troughs, shelves and similar articles etc. with plain faces, setting in cement mortar 1:4 complete all as specified and as directed.
Demolition of reinforced cement Concrete of any description and in any position not otherwise specifically provided for (as in shelves of kitchen, parapets of roof), reinforcement cut as required to facilitate demolition with and including separating, scrapping and cleaning of reinforcement etc complete all as specified and as directed.
S&F TMT Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Dismantaling brick tiles or terracing tiles single layer in roofs complete all as specified and as directed.
Taking down existing bitumen felt, roof treatment etc including cement mortar bedding layer and removing rubbish off the premises outside the MoD land complete all as specified and as directed.
Roughning the surfaces of old concrete by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed.
M&L for plain cement concrete (1:2:4) type B-1, using 20 mm graded mechanically crushed stone aggregates as in padding to roof to maintain the required slope and finished the surface even and smooth, without using extra cement complete all as specified and as directed.
Supply only Integral waterproofing compound ISI marked complete all as specified and directed.
M&L for APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced with polyster non wove fabric( weight not less than 150 gms/sqm) laid on primed surface by forced application with and including approved bitumen primer as per manufacturer's instructuctions including cleaning the surfaces complete all as specified and as directed. Note: Sheet shall be five layered prefabricated Atactic Polypropyleen Polymer (APP) modified 3 mm thick membrane (weighing not less than 3 kg/sqm) reinforced with 150 gsm polyester non- woven fabric. Concrete of roof surface shall be scratched with scratched tool before finishing roof surface when the concrete surface is still green,10mm thick 1:4 cement plaster shall be laid .The roof surfaces shall be throughly wire brushed, washed, dried up and cleaned to all foreign matter and dust prior to the appliction of primer. On the dried surface one coat of approved bituminous primer, having density in the range of 0.87 to 0.89 kg/litre at 25 degree centigrade and viscosity of 40 to 160 CPS, manufactured by same manufacturer @ 0.4 litre / sqm shall be applied. APP membrane shall be laid on primed surface by torch application method after allowing 24 hours for primer to dry . Laying off APP membrane will normally be laid in length at right angle to the direction of slope. The overlaps shall be of minimum 100mm on longitudinal direction and 150 mm on the transverse direction. All overlaps shall be bonded with bitumen primer and levelled by heating the overlaps with butane torch. the treatment shall be done by the approved authorised applicatiors.
M&L for cement concrete tiles 20cm x 20cm x 20mm thick, machine pressed, set jointed and pointed in neat cement slurry laid on roof with and including 15 mm thick screed bed in CM (1:6) complete all as specified and as directed.
All as per item No 71 here-in-before but except tiles. Note:- Old serviceable tiles retriened against item No 66 here-in-before shall be reused after cleaning the cement mortar properly.
S&F PVC (SWR) pipes of pressure rating 6 Kgf/cm2, 110mm bore double socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc (measured overall as fixed along the centre line over fittings and accessories complete all as specified and as directed.
Taking up or down steel water tubing and connection of 15mm bore complete all as specified and as directed.
Taking up or down steel water tubing and connection of 20mm bore complete all as specified and as directed.
M&L for GI tubing 15mm bore medium grade fixed to walls, ceilings or laid in floors complete all as specified and as directed.
M&L for GI tubing 20mm bore medium grade fixed to walls, ceilings or laid in floors complete all as specified and as directed.
S&F in repair cast iron 100mm bore sand cast soil waste or vent pipe as in any length with or without ears with cement joints fixed to wall complete all as specified and as directed.
S&F in repair cast iron 100mm bore sand cast soil waste or vent pipe as in any length with or without ears with cement joints laid in floors/ trenches complete all as specified and as directed.
S&F in repair cast iron 75mm bore sand cast soil waste or vent pipe as in any length with or without ears with cement joints fixed to wall complete all as specified and as directed.
S&F in repair cast iron 75mm bore sand cast soil waste or vent pipe as in any length with or without ears with cement joints laid in floors/ trenches complete all as specified and as directed.
S&F cast iron Bends 100mm bore of pipe (any radius), diminishing pieces or tapers (larger bore measured) with oval access doors complete all as specified and as directed.
S&F cast iron Bends 75mm bore bore of pipe (any radius), diminishing pieces or tapers (larger bore measured) with oval access doors complete all as specified and as directed.
S&F cast iron100mm bore of pipe Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and as directed.
S&F cast iron75mm Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and as directed.
S&F in repair cast iron floor trap 75mm dia of outlet with grating including jointing to waste pipe, fixed in cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate complete all as specified and as directed.
S&F in repair PVC connections 600mm long including back nuts and washers fixed to 15 mm bore of pipe complete all as specified and as directed.
S&F in repair vitreous china ware WHB (white) of size 450x400mm with and including chromium plated waste coupling of 32mm bore and 60cm long PVC waste pipe complete all as specified and as directed.
S&F in repair vitreous china ware wash down water closet (Pedestal pattern) coloured including connection to drain (out going pipe) and to flushing pipe, anti syphonage pipe etc with and including plastic seat cover coloured, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device and making good to the floor complete all as specified and as directed.
S&F in repair PVC valveless, syphonic action type, low level flushing cistern,10 ltr capacity white with inlet ball valve, float handle and connection complete all as specified and as directed.
S&F in repairs bib taps brass cast copper alloy (CP) with crutch or butterfly handles, screwed down, screwed for 15mm bore iron pipes or for brass ferrules and fixed complete all as specified and as directed.
S&F in repair Stop valves, cast copper alloy, screwed down, high pressure,with crutch or butterfly handle,screwed both ends for 15 mm bore iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repair stainless steel sink, 1.00mm thick for kitchen, with CP brass waste coupling, PVC waste pipe, washers, including connecting union etc, overall size 495mm x 420mm with bowl size 410mm x330mm x 160mm complete all as specified and as directed.
Dismantling PVC water storage tank of capacity exceeding 250 litre but not exceeding 500 litre complete all as specified and as directed.
S&F Rotational moulded PVC, double layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. complete all as specified and as directed.
Fixing only Rotational moulded PVC, double layered, water storage tanks of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including new fittings such as GI tank nipple etc. complete all as specified and as directed.
Rounding to Edges of stone slabs one edge, such as in steps, cooking plateform and other similar situations complete all as specified and as directed.
M&L for preparation of old decorated plastered surfaces of walls by rubbing down and applying one coat of Acrylic distemper water based (Ist quality) complete all as specified and as directed.
M&L for preparation of plastered or un-plastered old decorated surfaces of ceiling, and applying one coat of white wash on ceiling complete all as specified and as directed.
M&L for Preparation of old wooden surfaces of any description not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for complete removal of existing treatment and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed.
M&L for Prepration of old painted steel surfaces of any description not otherwise described over10cm in width or girth and applying two coats of synthic enamel paint complete all as specified and as directed..
M&L for Preparation of old plastered or unplastered surfaces of walls and applying two coats of white wash complete all as specified and as directed.
S&F in repair chromium plated shower roses with or without swivel joints, 125mm size, including fixing to steel pipe or union complete all as specified and as directed.
S&F in repair Brass CP mixer for mixing hot & cold water screwed down for 15mm dia bore of iron pipe and fixed complete all as specified and as directed.
S&F in repair Ball valves, high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for 20mm bore (minimum weight 210 gms) GI pipe and fixed complete all as specified and as directed.
M&L for providing cement concrete 1:2:4 type B0 as in backs of pressed steel chowkats complete all as specified and as directed.
S&F health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia bore of pipe with 1.25 meter long flexible tube and ABS wall hook including, making connections and fixed in position complete all as specified and as directed.
S&F in repair stainless steel Kitchen plate rack of size 900mm x 900mm and 250 mm in depth (weight not less than 6.5 kg) with all internal fitting and fixed to wall by means of plug and steel screws including washers etc complete all as specified and as directed.
S&F in repair PVC (SWR) Gully trap 125/110mm setting and jointing with solvent cement complete all as specified and as directed.
S&F in repair Towel rail 600 mm long PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats( min weight weight 190 gms) complete all as specified and as directed.
INTERNAL ELECRIFICATION WORKS
Taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling rosees, pendants, regulators , sockets, light fittings, bell, security lights etc. and making good the disturbed surfaces of walls,ceilings etc. complete all as specified and as directed.
M&L for Point wiring with 1.5 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked PVC conduit not less than 20 mm dia with accessories concealed in wall/ceiling incuding provision of 1.5 Sqmm single core PVC insulated, unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including MS sunken box or pressed steel terminal boxes made out of 1.6 mm thick MS sheet with provision of new 3 mm thick plastic laminated sheet top cover over sunken box for housing the switches, socket outlets, fan regulators etc. with brass screws and brass washers with and incluing making good the disturbed surfaces as per existing for one light/fan point controlled by one switch complete all as per specified and as directed.
All as per item No 118 here-in-before but for one light point controlled by 2 way switches
All as per item No 118 here-in-before but for one socket outlet point 5 Amps on same board.
All as per item No 118 here-in-before but for one socket outlet point 5 Amps on independent board.
All as per item No 118 here-in-before but with 2.5 sqmm cable for 3 pin 15 amps switch socket outlet (Power point).
All as per item No 118 here-in-before but for one bell point controlled by one bell push.
S&F switch piano 6 Amps flush type single pole one way 230 volt , AC supply complete all as specified and as directed.
S&F switch piano 16 Amps flush type single pole one way 230 volt , AC supply complete all as specified and as directed.
All as per item No 125 here-in-before but for two way 230 volt complete all as specified and as directed.
S&F socket outlet 3 pin 6 amps 230 volt AC flush type specified, complete all as specified and as directed.
S&F socket outlet 2 in 1, 3 pin 6/16 amps 230 volt. flush type, complete all as specified and as directed.
S&F bell push 5 Amps flush type single pole one way 230 volt , AC supply complete all as specified and as directed.
S&F in repair door bell electric, ding dong type, single phase 230 volts, complete all as specified and as directed.
S&F ceiling rose 3 phase/PVC/polycarbonate, isolated body complete all as specified and as directed.
S&F LED lights fitting 1x 20W, 220 V, AC with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core fleexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F fan regulator electronic step type , 250 volts, AC supply suitable for ceilling fan of any type/make/sweep complete all as specified and as directed.
S&F lamp holder PVC /polycarbonate type with back plate, complete all as specified and as directed.
S&F exhaust fan of sweep 300mm, metallic body complete with louvers shutter, voltage 230V, 50 Hz, single phase, Min. 1200 RPM, Copper winding, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F RCBOs for earth leakage, overload and short circuit protection double pole 30 mA current rating 25/32 Amps 230 volts, 50Hz , breaking capacity all as specified and and as directed.
S&F MCB single pole 240 volts, 50Hz , breaking capacity 10KA, B curve 6A to 32A, ISI marked all as specified and as directed.
S&F MCB SPN 240 volts, 50Hz , breaking capacity 10KA, B curve 40 A, ISI marked all as specified and as directed.
S&F MCB SPN 415 volts, 50Hz , breaking capacity 10KA, B curve 63 A, ISI marked all as specified and as directed.
S& F vertical Loadline TPN DB, 4 ways, double door, with provision for MCCB 100A having IP-43 protection with and including dismantling and taking down old unsv and making connections with suitable size of lugs and making good the disturbed surface to match with existing surface complete all as specified and as directed.
S&F sheet metal enclosures distribution board SPN 8 ways double door , IP 43 protection, 240 volts, with shrouded neutral bar & insulated bus bar and earth link, suitable for MCBs/RCBOs as incomer and out going complete dully grouted on the wall (flush) with and including dismantling and taking down old unsv and making connections with suitable size of lugs and making good the disturbed surface to match existing surface all as specified and as directed.
M&L for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5 m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized lead wire 4mm dia (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 15mm dia bore, and watering pipe 20 mm bore GI light grade pipe with funnel & wire mesh, including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, including taking out old earthing materials and removal complete all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include GI lead wire and protection pipe of length 7.5m, GI pipe beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to Govt.
M& L for Sub main wiring with two single core 4 sqmm (nominal area) stranded copper conductor FRLSH PVC insulated and unsheathed cable drawn in and including non metalic PVC regid conduit medium grade of suitable size with all standard fittings, concealed, including one run of continuous PVC insulated stranded copper conductor FRLSH cable 4 sqmm (nominal area) for earth continuty, including taking out and removal of old sub main wiring complete all as specified and as directed. (Note :- 2 runs of 4sqmm copper conductor phase and neutral and one run of same size earth wire including one run of PVC conduct with cutting, chasing & making good shall be measured as one unit length)
M& L for Sub main wiring with two single core 6 sqmm (nominal area) stranded copper conductor FRLSH PVC insulated and unsheathed cable drawn in and including non metalic PVC regid conduit medium grade of suitable size with all standard fittings, concealed, including one run of continuous PVC insulated stranded copper conductor FRLSH cable 6 sqmm (nominal area) for earth continuty, including taking out and removal of old sub main wiring complete all as specified and as directed. (Note :- 2 runs of 6sqmm copper conductor phase and neutral and one run of same size earth wire including one run of PVC conduct with cutting, chasing & making good shall be measured as one unit length)
S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW of capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece Plastic 16 Amps 30mA PRCD shock proof plug top etc. complete all as specified and as directed.
Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor and wall etc complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated and armoured, heavy duty, electric power cable, cross sectional area 25 Sqmm 4 core aluminum conductor 1100volts grade under ground cable including both side connection with cable lugs etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete all as specified and as directed. Note: Returning filling & removal of earth, sand cushioning and bricks for protection of cable shall be measured and paid separately.
M&L for sand cushioning with a layer of dry river sand and punning to provide required cover as per SSR part -I complete all as specified and as directed. Note : Punned down thickness (overall 18cm) shall be considered for measurement and payment.
Supply & laying un-reinforced cement concrete cable cover class LV Type 2 of size 300mmx180mmx40mm laid flat and dry perpendicular to the direction of cable adjacent to each other over the cable for protection complete all as specified and as directed.
M&L for cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in coping of pole and strut, stay around the pole, road cutting etc complete all as specified and as directed.
M&L for laying in replacement HDPE (DWC) pipe of outer dia not less 50 mm fixing on poles, walls, under floors, road, drain crossing, laying on surface etc as reqd at site complete all as specified and as directed.
S&F LED street light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
S&F MCCB 4 pole 415 volts, 50Hz , 100 Amps adjustable 16 KA, complete all as specified and as directed.
S&F 16Amps 30mA PRCD plug top, shock proof, with auto trip feature in case of any current leakage alongwith connection in existing geysers incl dismantling and taking down old unsv normal plug top complete all as specified and as directed.
Note: The Total amount shall subject to adjustment of credit of Rs. 127434.00 for old Materials as per Schedule of Credit.
B N FRIENDS AND CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .