Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC 9 NAROTTAM KUNJ MADHU NAGAR AGRA CANTT 282001 | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹25.2 L+₹3.1 L (13.8%)Rejected-Finance 38 49 D OLD IDGAH COLONY AGRA U P 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Being higher bidder | |
| 3 | L3₹34.7 L+₹12.5 L (56.6%)Rejected-Finance | L3 | Rejected-Finance Being higher bidder |
Tender Value
Refer Docs
EMD Value
₹70,700
Closing Date
7 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF Agra
HQ CWE AF Agra
Repair and Maint of HT Distribution System O/H and U/G and Allied works in domestic Area under GE (AF) Adm Area, Kheria Agra
2020_MES_401278_1
80020-19/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF Adm Area Agra
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AF Adm Area Agra
₹70,700
Yes
11 Feb 2021
7 Dec 2020
12 Jan 2021
7 Dec 2020
7 Jan 2021
25 Dec 2020
9 Dec 2020 - 11 Dec 2020
60 days
Amount
Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in soft/loose soil and n.exc 10 Sqm on plan and leveling of bottam Complete all as specified and directed.
All as per item No 1here in before but exc 1.5 mtr and n.exc 3m deep deepth all as specified and directed.
Returning and filling in of excavated soil including spreading,levelling,watering and well ramming in layers not exceeding 25 cm each all as specified and directed.
Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed..
M & L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid all as specified and directed..
Supplying and laying un-reinforced precast concrete cable cover factory made as per IS 5820-1970, class HV, type 1 , size 300mm x 180mm x 40mm all as specified and directed.
Re-laying only old reterieved unreinforced precast concrete cable cover for protection of cable complete all as specified and directed
Excavation in post holes for similar holes (or similar holes) each n.exc 0.5 cum and getting out removing returing filling in and rammining surface returing leveling complete all as specifie and directed
Supply ,laying , testing & commissioning of HT UG cable, XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable(heavy duty) with stranded aluminium conductor 11 KV grade (Earthed system cable) as per IS 7098 Part-II, of following sizes all as directed including dismantling and taking out from trenches old one. Note:- (a) Earth work ( Excavation, Returning & refilling and removal), sand cushioning, concrete cable covers,GI pipe protection for road crossings, HT termination joints will be measured and paid separately all as specified and directed. Make:- Havells/ ICL/CCI/Universal
a) 3 core 240 Sqmm
b) 3 core 185 Sqmm
c) 3 Core 120 Sqmm
d) 3 Core 95 Sqmm
Relaying of old existing serviceable cables of any size and description obtained from item No:-1 here in before complete all as spd and directed.
Supply and fixing in replacement of GI tubing light grade galvanised with all fittings laid in trenches/ on pole/ wall/ floor etc for protection of cable complete all as spd and directed of following sizes:- Make:- Jindal/ Tata/ Zenith
a) 100 mm bore
b) 80 mm bore
Dismantling damaged /unserviceable concrete poles/ steel tubler poles/ struts, any size complete all as specified and directed.
Supply and erection in vertical position Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws, type 410 SP-55 (11.0 metres long) all as specified duly factory painted with two coats of black bituminous paint internally through out and externaly for embeded portion and painting with one coat of red oxide primer, applying two coats of synthetic enamel aluminium paint on remaining exposed surfaces after errection complete, painting with synthetic enamel paint of colours black and yellow alternate strips of 30cm width upto 1.5 mtr from the top of coping complete including making suitable holes where required all as specified and directed .Note : PCC in foundation, coping, Earth work ( Excavation, Returning & refilling and removal) will be measured and paid separately under relative items of Sch 'A'. all as specified and directed. Make:- Nataional Tubing Co Kanpur Bharat Conduit Kanpur, BCW Kanpur.
M & L for Plain cement concrete (1:4:8) type D-2 (Using 40 mm graded crushed stone aggregate) as in foundation for poles mass concretes or in any indicated positions etc complete all as specified
M & L for Plain cement concrete (1:2:4) type B-1 (Using 20 mm graded stone aggregate) for coping of pole including necessary form work complete all as specified
Material & labour for fixing in repairs Stay assembly complete with accessories such as MS stay plate of size 300mmx300mmx6mm thick, stay rod 20mm dia, stay bow, nuts, bolts and check nuts of GI including GI stay strand of size 7/4 mm all as shown in electrical plate No. 1 of SSR Part-I of 2009 or directed by Engr-in-charge. Note: Earth work ( Excavation, Returning & refilling and removal), PCC, stay clamp and loop type insulators will be measured and paid separately under relevant schedule items).
M & L for Loop type insulator large size with overall dimensions 90x140mm with clearance of hole 25.5 mm vitreous white brown or green complete all as specified including dismantling old defective. Make:- JB/ BHEL/ Pactil/ Reychem.
M & L for Plain cement concrete (1:3:6) type C-2 (Using 40 mm graded stone aggregate) as in foundation filling and mass concrete for stay complete all as specified and directed.
M & L cable jointing kit for 11 KV (Earthed) grade XLPE cable for straight through cold shrinkable type joint complete with jointing material and accessories suitable for following sizes including testing after jointing complete all as directed . Make:- Denson/ Birla 3 M/ Cab Seal all as specified and directed.
a) 3 core 240 sqmm to 400 sqmm.
b) 3 Core 120 sqmm to 185 sqmm
M & L cable jointing kit for 11 KV (Earthed) grade XLPE cable for outdoor end termination cold shrinkable type joint complete with jointing material and accessories suitable for following sizes including testing after jointing complete all as directed . Make:- Denson/ Birla 3 M/ Cab Seal all as specified and directed.
a) 3 core 50 sqmm to 95 sqmm
b) 3 core 120 sqmm to 185 sqmm
c) 3 Core 240 sqmm to 300 sqmm
M & L cable jointing kit for 11 KV (Earthed) grade XLPE cable for indoor end termination cold shrinkable type joint complete with jointing material and accessories suitable for following sizes including testing after jointing complete all as directed . Make:- Denson/ Birla 3 M/ Cab Seal all as specified and directed.
a) 3 core 50 sqmm to 95 sqmm
b) 3 core 120 sqmm to 185 sqmm
c) 3 Core 240 sqmm to 300 sqmm
Supply, fabricate and fix cross arms any size along with, brackets, clamps, bolts, nuts, washers, bracers etc including drilling holes, cold/hot complete and fixed to pole including one primer coat and one under and finishing coat of paint all as specified and directed.
M & L replacement of ACSR conductor of any size as ordered by Engr-in-charge including tightening and bindingh with new binding wires to insulators all as directed all as specified and directed. Make: Indian Aluminium Co /Bhart Conductor /Jaipuriya Brothers
M & L pin type insulator vitreous, white, brown, or green insulator includig one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150 mm height, 150 mm dia for 11000 volts grade. Make:- JB/ BHEL/ Pactil/ Reychem
S & F disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 Volts all as specified and directed. Make:- JB/ BHEL/ Pactil /Reychem
M & L anti climbing device, spikes type fabricated out of MS bars (round/square/flat) including nuts,bolts, washers and welding in two halves made to shape to suit the cross section of the pole including dismantling old one complete all as spd and directed.
S & F in replacement of danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts, nuts of approved size for HT 25x20 cm size including dismantling old one.
Dismantling air break gang operated switches triple pole vertical/ horizontal mounted including isulators and opretaing mechanism for replacment all as directed.
Supply , install, testing and commissioning of HT 11 KV Switch air break, with DO fuse gang operated, triple pole , mechanically operated, mounted on insulators and MS channel frame, with operating mechanism made out of 25 mm dia GI medium grade pipe suitable for operation from ground level with locking arrangement complete for current rating 200 Amps complete all as specified and directed. Make:- JB/ BHEL/ Pactil.
S & F HT lightening arrestor metal oxide type (gap less) heavy duty single pole for 11 KV overhead line , suitable for 12 KV rated highest system voltage, long duration distribution discharge class type, IP 55 Degree of protection, 100(kVp) at 65 kA High current impulse withstand voltage and 9 KV Arrestor rating with normal discharge current of 10 KA complete with all fittings conforming to IS: 3070 part-3 effectively connected with earthing system complete all as specified and directed. Make:- JB/ BHEL/ Pactil / GE power /oblum
All as per item No 30 here in above but suitable for 33 KV complete all as spd and directed. Make:- JB/ BHEL/ Pactil/GE power /oblum
M & L for fixing in repairs Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with galvanised iron strip 32x6 mm including dismantling old one. .
Material and labour earthing with steel earth plate galvanized electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in soft / loose soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in soft / loose soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing) and dismantling old defective earthpit.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4Kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in soft / loose soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion.NOTE :-Rates inclusive of necessary excavation in soft / loose soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing) and dismantling old defective earthpit. .
S & F Plates (plain or chequered), channels, angle irons, square cut or notched (ordinary and counter sunk) forming holes, without any attachment all as directed conforming to Fe 410-O 0r Fe 310-O including applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer including dismantling old rusted cable/duct covers Complete all specified and directed.
Cutting bushes, levelling the area around E/M installation, sub stations, pole structure etc including surface excavation not exceeding 30 cm deep and avearaging 15 cm deep and getting out roots etc and throw away not less than 50 mtr from the site and making good all as specified and directed.
M & L for MS work with hand rails ,half round or other stock section ,drilled and countersunk for balusters running bars,including embeding in concrete and screwing etc , struts in fencing including cutting tops to shape as directed ,drilling holes ,notching for wire etc,flat iron fillets (for securing wire mesh/XPM net etc) including all necessary drilling ,bolting or riveting and similar work conforming ton Fe--290 Gde E-165 complete all as spd.
Supply only GI 4 mm dia wire chain link fencing n.exc 4.0 kg /Sqm of approved mesh size including line wire etc including taking out old fencing etc. Complete all as specified and directed.
Suply only 12 mm dia mild steel round bars confirming to fe-290 (Grade E-165) in required length for chain link fencing complete all as specified amd directed.
Fixing only chain link fencing including line wires any dia any mesh size and type of strendeds., rail , stranding bolts e.t.c including provisioning of binding wire complete all as specified and directed.
M&L Preparation of steel and iron surface on any description over 10 cm in width or grith not otherwise description over 10 cm in width or grith not otherwise described and painting with two coas of synthetic enamal paint over a coat of red oxide primer.
M&L for hard core using broken stone or bolders of gauge exc 63 mm but not exc 100 mm, diposited, spred and levelled in layers n.exc. 15 mm thick, watered and rolled / rammed to true surface complete all as specified and directed.
M&L 75 mm thick PCC 1:3:6 type C2 (Using 40 mm Graded stone aggregate) as in sub base in floors etc complete including necessary form work all as specified and directed.
Supply and lay Graded coarse aggregate of size 20 mm dia in outdoor sub-station yards completed all as specified and directed.
M & L for painting of steel tubular pole 11 mtr height including cross arms/ bracket with two coats of aluminium paint after prepration of surface of pole incl. painting white and blue alternate strips upto height 1.5 m (each strip 0.30 cm) from bottom on HT pole and writing the pole numbers as per MES pattern including cleaning/ removing shrubs/ grass 1.5 mtr around the pole complete all as spd and directed. Note : (i) Necessary permission will be obtained from department by contractor one day prior for painting to poles in particuar area and shut down of that area shall be arranged by department.
Supply , install, testing and commissioning in replacement of existing unsv outdoor type, 33 KV gang operated switch, rotary type, double break of current rating upto 400 Amps, triple pole each pole consisting of galvanised steel base, HT insulators as per IS, non ferrous knife and spray, loaded contacts, arching horns of adequate section to break magnetizing current of the transformers, horizontal pipe of adequate length for phase seperation adequate length of GI pipe for operation from ground level and operating handle with locking arrangement complete in both ON and OFF position. All ferrous parts hot dipped galvanised and non ferrous heavily tinned to with stand weather suitable for vertical mounting complete all as specified and directed. Make:- JB/ BHEL/ Pactil/ ECE
S & F in replacement of cable route indicators made out of MS sheet of size 45 cm x 30 cm of 2 mm thick with writing HT cable with MS angle frame and two nos legs of 1.2 mtr long of size 25 x 25 x 5 mm fixed on ground in PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) platefrom of size 15 x 15 x 15 cm complete all as spd and directed.
Supplying, fixing, testing and commissioning new battery 2 volts, 250 AH incl. connecting leads of copper strip in existing battery bank complete all as spd and directed. Make:- Amron/ Exide/ Amco
M & L for painting and servicing of HT 11 KV Steel tubular two pole structure with one coat of aluminium paint after preperation of surface by replacing galvanized PG clamps, GI bolts and nuts, pieces of ACSR conductor with insulation of any size as jumpers including lubricating the moving parts of AB switch and cleaning of all disc /pin insulators and applying silicon compound for prevention of arcing due to dust/ salt deposits over the surfaces including applying one coat of zinc oxide primer on rusted portions after preparation of surfaces & a coat of aluminum paint to the entire steel structure complete all as directed. Note:-Rate quoted shall be inclusive of painting of steel structure, ACSR conductor for jumpering, GI hard ware like nuts, bolts etc complete all as spd.
M & L for drilling suitbale dia horizontal bore holes for insertion/ laying of 80 / 100 mm bore GI tubing of any description below/ under road surface/ floors etc with using mechanical or manual devices as required at site complete all as spd and directed.
M & L for checking and finding out pin point location of fault in HT 11 KV undergroung cable with the help of fault locating machine complete all as spd and directed. Note:- (i) Rate for the rent of fault locating mobile machine, charges for operator, engineer, electrician etc are deemed to be included in the quoted rate. (ii) Checking and finding fault upto 03 places of same route of the cable will be considered as one job.
Dismantling old defective/peeled of Insulating Mat and M/L for Elastomer Insulating Mats for Electrical Purposes Class A/voltage grade upto 33 KV (AC) as per IS : 15652:2006 with ISI mark of thickness 2.5 mm+ 10% of approx width 1 mtr along with suitable adhesive /chemibound resin waterproofing compound and sealing material all as per SSR Part -I clause 19.23 A1 to 19.23 A-7 including dismatling of old difective / peepled of insulating material complete all as specified and directed. Make: Electromat or equivalent approved by GE
S & F in replacement of existing unsv relay with MC 61 A feeder protection relay suitable for 33 / 11 KV grade complete all as spd and directed. Make:- L & T/ Schenieder/ CG.
M & L for disconnecting and opening of SF6 unit from 11 KV, 400/ 630 Amps, VCB/ ring main unit after taking shut down from main, opening the SF-6 gas chamber carefully, filling SF-6 gas of required quantity and checking/ inspection the complete chamber and replace if found any worn out parts and re-fitting the same including commissioning, testing the same to entire satisfaction complete all as spd and directed.
S & F in replacement installation, testing and commissioning Cast Resin Three phase Potentail Transformer of ratio 11KV/√3/110V/√3/110 V/√3 , 50VA , Class 0.5- 3, Burden with desired capacity PT Fuses complete all as spd and directed.
Dismantling old defective auxiliary power supply panel and Supply, install test and commissioning of auxiliary power supply panel indoor floor mounted factory made out of 2mm thick MS sheet front operating cubical type providing bus bar chamber with aluminium bus bar of suitable size, 30V DC output in float mode,including supply & interconnection with solid copper conductor cable, painting with one coat of red oxide primer and two coats of synthetic enamel paint complete comprising the following all as specified.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .