Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.0 LAccepted-AOC | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹40.3 L+₹90,376.83 (2.30%)Rejected-Finance SANTIPUR HILL SIDE PS BHARALUMUKH GUWAHATI 781 009 | KAMRUP METRO | ASSAM | 781009 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹40.6 L+₹1.3 L (3.20%)Rejected-Finance VILL KAHIKUCHI PS PO AZARA DIST KAMRUP GUWAHATI ASSAM 781 017 | KAMRUP METRO | ASSAM | 781017 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹40.8 L+₹1.4 L (3.55%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹41.3 L+₹1.9 L (4.87%)Rejected-Finance AZARA GOSALPARA DIST KAMRUP M GUWAHATI 781 017 ASSAM | KAMRUP METRO | ASSAM | 781017 | L5 | Rejected-Finance Other than L1 |
Tender Value
₹36.5 L
EMD Value
₹72,920
Closing Date
20 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati, Assam, Pin- 781015 Tele 0361 - 2840127
ADDN ALTN TO MEDICAL STORE ROOM AND PROVN OF WATER FILLING POINT AT FIRE SECTION DAIRY FARM AND MSB SITE AT 19 WING UNDER GE AF BORJHAR.
2023_MES_624348_1
8371/BOR/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) Borjhar
Class D Cat a(i) and b(i)
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Borjhar
₹72,920
Yes
28 Feb 2024
20 Oct 2023
22 Nov 2023
20 Oct 2023
20 Nov 2023
11 Nov 2023
Amount
Surface dressing not exc. 30cm deep and averaging 15cm deep and getting out in soft/ disintegrated rocks, complete all as specified and as directed.
Excavating over areas, n.exc 1.5m deep and getting out in soft/loose soil, complete all as as directed.
Excavating over areas, exc 1.5m deep but n.exc 3.00 metre and getting out in soft/loose soil, complete all as as directed.
M & L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete etc., complete all as specified and as directed. (1.5+1.08+0.50)
M & L for RCC M-25 Design Mix concrete as in column footing, column upto bottom of plinth beam and in plinth beam, complete all as specified and as directed.
M & L for RCC M-25 Design Mix concrete as in column above plinth beam upto bottom of roof beam, complete all as specified and as directed.
M & L for RCC M-25 Design Mix concrete as in roof slab supported on beam/wall etc, complete all as specified and as directed.
M & L for RCC M-25 Design Mix concrete as in roof beam etc, complete all as specified and as directed.
M & L for RCC M-25 Design Mix concrete as in lintel beam etc, complete all as specified and as directed.
M & L for RCC M-25 Design Mix concrete as in chajja, complete all as specified and as directed.
M & L for formwork to sides of concrete foundations, footings, bases of columns, columns up to plinth beam and plinth beams; and similar work; vertical of batter, fair finished surfaces, complete all as specified and as directed.
M & L for formwork to sides of pillar, posts, piers, column etc., fair finished surfaces, complete all as specified and as directed.
M & L for formwork to sides and soffits of lintel beams etc., fair finished surfaces, complete all as specified and as directed.
M & L for formwork to sides and soffits of chajja etc., fair finished surfaces, complete all as specified and as directed.
M & L for formwork to sides and soffits of roof/floor beam etc., fair finished surfaces, complete all as specified and as directed.
M & L for formwork to sides and soffits of roof/floor slab etc., fair finished surfaces, complete all as specified and as directed.
S & F mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia or securing with clips, complete all as specified and directed.
S & F mild steel TMT bars 8 mm to 10 mm dia and over cut to length, bent to shape required including cranking bending spirally for hooping, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia or securing with clips , complete all as specified.
S & F mild steel TMT bars 8 mm to 10 mm dia cut to length, bent to shape required including cranking bending with MS wire (annealed) not less than 0.90mm dia or securing with clips as in stirrups, complete all as specified.
Returning and filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm, complete all as directed. (29.63+2+49)
Removing excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as directed. (9.67+3+16)
M & L for brick work with sub class 'B' bricks straight or curved on plan exc. 6 metre mean radius, built in cement mortar CM (1:6), complete all as specified and as directed.
M & L for damp proof course 25 mm thick to horizontal or vertical surfaces including necessary formwork including applying evenly a coat of blown type bitumen at the rate of 1.5 Kg per sqare metre and binding with clean dry sand @ 0.50 Cum per Square metre, complete all as specified and as directed
Earth filling in plinth layer including watering and well consolidation, complete all as directed.
Sand filling in plinth layer including watering and well consolidation, complete all as directed. (6.07+2)
M & L for PCC (1:5:10) type E-2 using 40mm graded stone aggregate as in sub base of floor, complete all as specified and as directed.
M & L for polythene film, 150 micron thick, laid on floor, complete all as specified and as directed.
M & L for rendering 15mm thick in cement mortar (1:6) on other than fair faces of brickwork or concrete surfaces internal plastering, finished even and smooth (without using extra or cement), complete all as specified and directed.
M & L for rendering 15mm thick on fair faces of bricks/concrete surface work in cement mortar (1:4) as in external plastering in two layers (10+5)mm, top coat of 5mm to be mixed using Water Proofing Compound (WPC) as per manufacturer's instructions on walls finished even and fair, complete all as specified and as directed. (Note: WPC shall be measured and paid separately).
M & L 5 mm thick rendering on or concrete surfaces as in ceiling and chajja, with cement mortar 1:3 finished even and smooth without using extra cement complete all as specified and directed.
M & L preparation of newly plastered surface of ceiling and applying three coats of white wash on the surface, complete all as specified and directed.
Supply only integral water proofing compound, ISI marked.
M & L for preparation of new plastered surfaces of extenal walls and applying two coats of exterior emulsion paint over a coat of wall primer (camouflage pattern), complete all as specified and directed.
M & L for preparation of new plastered surfaces of internal walls and applying two coats of oil bound distemper, over a coat of primer, complete all as specified and directed.
M & L for 40 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in sub base flooring to receive tiling etc., complete all as specified and as directed.
M & L for 15mm thick screed bed in cement mortar (1:6), for laying floor finishes complete all as specified and as directed.
M & L for rendering 10mm thick in cement mortar (1:4) fixing tiling work in vertical surfaces of skirting, complete all as specified and as directed.
M & L for 10 mm thick light colored vitrified ceramic tiles of size as in floor, n.exc 0.36 Sqm set and jointed in neat cement slurry and pointed in white or coloured cement to match over, complete all as specified and as directed.
All as per item No. 38 here-in-before but in skirting.
M & L for Water Proofing treatment on "non approachable/non accessible roof" surface (Horizontal and vertical surfaces) in following sequence through manufacturer/authorised applicator of the manufacturer all as specified and directed complete. (i) Applying approved bituminous based primer conforming to IS: 3384-1955 @ 0.3 Kg/Sqm to be applied on top surface of prepared surface till the surface is properly impregnated. (ii) Laying APP (Atactic polypropylene Polymer modified prefabricated membrane) water proofing membrane of weight not less than 3 Kg/Sqm with minimum 100 mm side overlap along the length from downward to upward completely sealed with Torch apllication /hot blown lamps. (iii) Applying two coats of bituminous based aluminium paint @ 0.3 Kg/Sqm, complete all as specified and as directed.
S & F anodised aluminium frame powder coated (minimum thickness of powder coating 50 micron) aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing, clips, rubber neoprene packing handles 2 nos in each door aluminium snap beading, screws etc, complete all as specified by Engr-in-Charge.
S & F anodised aluminium door shutter powder coated (minimum thickness of powder coating 50 micron) aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing, clips, rubber neoprene packing handles 2 nos in each door, hinges, aluminium snap beading, screws etc, complete all as specified by Engr-in-Charge.
S & F anodised aluminium window, ventilator shutters, side hunged type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing, clips, rubber packing, anodised aluminium snap beading, aluminium fittings such as pegs stays 150mm long (1 No), hinges type B-21, 100 mm long (2 Nos) suitable handle (1 No), screws etc, complete all as specified by Engr-in-Charge.
M & L for 4 mm thick plain glass, area exc 0.50 Sqm in each pane fixed in aluminium frame as in door/window/partition/ventilator, complete all as specified and as directed by Engr-In-Charge .
S & F 4 lever mortice lock vertical type size 65 mm long, aluminium body for aluminium door, complete all as specified and as directed.
S & F Aluminium anodised door stopper with rubber shoes of size minimum 150mm long, complete all as specified and directed.
S & F hydraulic regulated door closer, aluminium (die cast ) body, designation No.1, universal type, suitable for door shutters upto 700 mm in width and of weight not more than 35 Kg and fixed, complete all as specified and directed by Engineer -In-Charge.
S & F for anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15), of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and directed by Engineer -In-Charge.
S & F framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., n.exc 10 Kg each brackets, conforming to Fe-290, Gde-E-165 (Brackets over 10 Kg each to be measured under 'Structural steel' complete all as specified and directed by Engineer -In-Charge.
M & L for preparation surfaces of steel of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and directed.
Hardcore of broken stone aggregate of gauge n exc 63mm but n.exc 100mm, deposited, spread and levelled in layers not exc, 15cm thick, watered and rolled/rammed to a true surface as in plinth protection, complete all as specified and as directed. (2+15+0.40)
M & L for 75 mm thick plain cement concrete (1:3:6) mix, type C-2 using 40mm graded stone aggregate as in plinth protection, finished the surface even and smooth without using extra cement, complete all as specified and directed.
Demolition of brick work build in cement mortar including all quoins, arches, pillars, etc. but exceeding ashlar facing and pre-cast concrete articles, complete all as specified and directed.
Demolition of cement concrete un-reinforced in ground floors & paving n.exc 15cm thickness (below or above ground level) complete all as directed by Engr-in-Charge. (2+0.50)
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforced cut as required to facilitate demolition), complete all as directed by Engr-in-Charge
Demolition and breaking up drain pipes (slat glazed ware, AC or reinforced concrete) set in cement mortar, in 150 mm internal dia, complete all as directed by Engr-inCharge.
Demolition and breaking up drain pipes (slat glazed ware, AC or reinforced concrete) set in cement mortar, in 100 mm internal dia, complete all as directed by Engr-inCharge.
Taking down cement plaster of any description and in any position including raking out joints, hacking for key scrubbing down with water etc and removing of debris from site, complete all as directed.
Excavation in trenches, n.exc 1.5m wide and n.exc 1.5 m in depth, for foundation, etc., or for shafts, wells, cesspits, manholes, pier holes, etc., n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil, complete all as as directed. (2+4.5+65)
S & F, Reinforced concrete drain pipes of 100mm dia class NP3 laid and jointed in (CM 1:1) complete with collars in trenches and jointed, complete all as specified and as directed by Engr-in-Charge
S & F precast reinforced cement concrete cover slab for manhole cover and drain cover in RCC(1:2:4) type B1 using 20mm graded stone aggregate set in cement mortar(1:4), complete all as specified.
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for, complete all as directed by Engr-in-Charge
M & L for plain cement concrete type B0, 1:2:4 (using 12.5 mm graded aggregate) in levelling courses, laid to be minimum consolidated thickness of 25 mm, laid and complete in slope over roof, finished fair and even, complete all as specified and directed.
M & L for cleaning all loose dirt and rust from roof surfaces and applying roof treatment as under:- (a) 10 mm thick plastering in CM (1:4) using 100% coarse sand on roof/parapet walls with WPC @ 3% by weight of cement. (b) Applying a coat of bituminous primer @ 0.40 lit /Sqm on prepared surfaces and allow to dry. (c) Applying a coat of hot blown bitumen85/25 grade @ 1.20 Kg/Sqm over primer (d) Supply and laying of 3mm thick (Minimum) polymeric water proofing membrane weighing not less than 3 Kgs/Sqm, black finish reinforced with non woven polyster matt with help of torching with propane or butane gas using Torch with minimum 75 mm side overlap and 100 mm end overlap as per manufacturer's instructions (e) Applying a tack coat of hot blown bitumen grade 85/25 @ 10.20 Kgs/Sqm (f) Blinding with dry coarse sand @ 0.50 to 1.0 Kg/Sqm dusted over bitumen. Note: The net area of water proofing treatment shall be measured without any extra allowance for laps and portion inserted in groove which shall be deemed included in the quoted rates. Complete all as specified and as directed.
M & L for 20mm granite (of any type) work (tabled rubbed and polished) of any shade as in steps, jambs, pillars, window cills, cooking platform, cooking platforms and like in cement mortar CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match the shade of the granite slab including over 15 mm thick screed bed layer of cement mortar (1:6), complete all as specified and as directed.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/disintegrated rock, complete all as specified and as directed.
Removing excavated soil exc 250 m and n.exc 500m and depositing where directed at a level n.exc 1.5m above the starting point, complete all as directed.
M & L for cement concrete type B1, 1:2:4 (using 20 mm graded aggregate) as in kerb, complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Excavation in post holes (or similar holes each n.exc 0.50 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth in layers n.exc 25 cm thick watering and removing surplus soil to a distance n.exc 50m and making good disturb ground, as in soft/disintegrated soil, complete all as as directed.
M & L for PCC (1:3:6) type C2 using 40mm graded stone aggregate as in, foundation, filling and mass concrete, complete all as specified and as directed.
S & F mild steel work in roof trusses (framed), trusses purlins, crane gantries, rails and framing and heavy bracket framing beam, tee, angle, channel or flat sections, conforming to Fe-410W, including cleats, distance pieces etc., complete all as specified and directed. (700+192)
M & L for 50 mm thick plain cement concrete (1:2:4) mix, type B-1 using 20mm graded stone aggregate as in sub base, plinth protection, etc., complete all as specified and directed.
M & L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of epoxy anti corrosive paint over one coat of zinc primer, complete all as specified and directed by Engr-in-Charge.
M & L for 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base, surface finished fair and even,complete all as specified and as directed.
M & L for pre-polished chequered cement concrete tiles with grey cement and pigment of size 30 cmx30cmx22 to 25mm thick set and jointed with cement slurry over and including 15 mm thick bedding layer of cement sand mortar (1:6) and pointed with grey cement, complete all as specified and directed.
S & F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
M & L in repairs 100 mm thick, M-50 grade machine pressed pre-cast concrete interlocking paver block confirming to IS 15658-2006 with grey cement and pigment in any shape and size, complete all as specified and directed.
M & L for RCC (1:2:4) type B-1 using 20mm graded stone aggregate as in foundations, including rafts, footings, plinth beam etc., basement slabs, under-reamed piles and mass concrete, complete all as specified and as directed.
M & L for RCC (1:2:4) type B-1 using 20mm graded stone aggregate as in columns, pillars, post etc, complete all as specified and as directed.
M & L for formwork to sides of rough finished surfaces of concrete foundations, footings, bases of columns, sides and soffits (if any) of foundations and plinth beams and similar works etc., vertical or to batter, complete all as specified and as directed.
M & L for formwork to sides of pillars, posts, struts, piers, columns of shape square, rectangular or polygonal, complete all as specified and as directed.
S & F mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia or securing with clips, complete all as specified and directed.
S & F mild steel TMT bars 6mm to 8mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia or securing with clips, complete all as specified and directed.
S & F mild steel TMT bars 5 mm dia and over cut to length, bent to shape required including cranking bending with MS wire (annealed) not less than 0.90mm dia or securing with clips as in stirrups, complete all as specified.
M & L for 100 mm thick PCC 1:3:6 type D2 (using 40 mm graded stone aggregate) finishing surfaces of concrete in sub-floors, floors, etc., even and smooth,complete all as specified and as directed.
M & L for rendering 15mm thick in cement mortar (1:4) fair faces of brickwork or concrete surfaces internal plastering, finished even and smooth (without using extra or cement), complete all as specified and directed.
M & L for preparation of new plastered surfaces and finishing walls with acrylic smooth exterior paint in cmouflage pattern of required shade: New work (two or more coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) including preparation of new undecorated plastered/concrete of wall/roof, complete all as specified and directed.
Excavation in post holes (or similar holes each n.exc 0.50 Cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth in layers n.exc 25 cm thick watering and removing surplus soil to a distance n.exc 50m and making good disturb ground, as in hard/dense soil, complete all as as directed.
S & F steel work in tubular trusses including special shaped washer etc., complete using ERW or induction butt welded tubes conforming to IS: 1161-1979 grade St. 240 including distance pieces cleats etc., complete all as specified and as directed.
M & L for preparation of new or previously untreated surfaces of steel of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and directed.
M & L for point wiring for light point controlled by one way switch 5 Amp, 1.5 Sq mm PVC FRLS insulated unsheathed, copper conductor stranded 1100 volts grade cable including PVC casing and capping of size not less than 25x12 mm/32x12 mm suitable and conduit pipe medium grade as per site requirement, ISI marked with accessories such as tee, bend joint cover etc., round/square blocks at junctions etc., screws, gutti/rawl plug PVC, all as per site requirements including plastic terminal boxed for mounting of switches/sockets/regulator etc., and PVC FRLS insulated and unsheathed 1100 volt grade copper conductor, stranded 1.5 Sqmm, cable a continuous earth lead connected to common earth dolly, etc., complete all as specified and directed. Note: Proper colour coding to be adopted.
All as per item No. 92.00 here-in-before but with socket outlet 5 Amps, controlled by one way switch on the same board.
All as per item No. 92.00 here-in-before but with socket outlet 5 Amps, controlled by one way switch on independent board.
All as per item No. 92.00 here-in-before but with 4 Sqmm for one 3 pins,15 Amps socket outlet on independent board and 2.5 Sqmm PVC insulated multi stranded copper conductor cable as continuous earth wire.
S & F switch piano flush button single pole one way 5 Amp, 230 volts, complete all as specified and as directed.
S & F Switch socket combination, 5 pin 5 Amps flush type, universal, 230 volts, complete all as specified and directed.
S & F Switch socket combination 5 in 1, 3 pin, 6 Amps and 16 Amps flush type, universal, 230 volts, complete all as specified and directed.
Supply and fix ceiling rose three terminals PVC/ Polycarbonate, isolated body complete all as specified.
S & F surface mounted batten type LED luminaires 20W, 220 V AC, 50 Hz IP 20 with aluminium extruded housing polycarbonate diffuser and end caps, minimum efficacy 100 lumens/watts with 120 degress andle, CCT 6500, CRI> 80 power factor > 0.9, IP 20 surge protection 4.0 KV, THD < 20 % integral electronic driver with short circuit protection and open circuit protection, surge voltage protection , complete all as specified and as directed. Make: as per approved list.
S & F LED light fitting 1 x 9W/1x10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and as directed. Make: Havell/Bajaj/Phillips/Crompton Greaves.
S & F lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings (ISI marked), complete all as specified.
S & F LED NU Bulb of capacity 9 Watts 865 B22 3 Star, Havells Cat Part no. LHLDEUECNL8R009 945 6500 K 206 30 90 0.050 A B22 8539, complete all as specified and as directed.
M & L Sub main wiring two single core 6 Sqmm PVC insulated PVC multistanderd copper conductor cable heavy duty and one run of 6 Sqmm PVC insulated unsheathed multi stranded copper conductor cable for earth wire drawn in PVC casing capping of size not less than 25x12mm/32x12 mm , with all fitting and making and making good disturbed surface wall complete all as specified and as directed. Note : - Not : 2 runs of 6 Sqmm cable and 1 run of earth wire 6 sqmm shall be measured as one unit length.
S & F single pole and neutral enclosure with a two pin and earth plug and socket 240 V, 20 A, complete with one single pole MCB, specified and as directed. Make: As specified in List of Makes.
S & F sheet metal enclosures MCB SPN distribution board 8 way double door with IP-43 IK-09 protection single phase 240 volts, including 200 Amp rated copper bus bar and neutral link (ISI marked), fixed flush in wall/surfaces, including taking out old DBs and chases wall for fixing DB and makin good distributed wall/surfaces to match existing specification, complete all as specified and as directed.
S & F 240V, 10 kA 'C' Curve miniature circuit breaker (MCB) of single pole and neutral (SPN) and current carrying capacity 32 Amp in the MCB DB complete with connection testing and commissioning all as specified and as directed. Make: As specified in List of Makes.
S & F 240V, 10 kA 'C' Curve miniature circuit breaker (MCB) of single pole (SP) and current carrying capacity 6 to 32 Amp in the MCB DB complete with connection testing and commissioning all as specified and as directed. Make: As per approved list of makes.
M & L, for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanised earth lead wire 4.00 mm dia by means of bolts, nuts check nuts & washers of galvanised iron or steel, as shown in electrical plate No.3 of SSR Part-I, connected to earthing testing point all as specified and directed including excavation and connected work in hard/dense soil, PCC 1:3:6 ty C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15mm dia bore GI light grade as earth lead protection pipe, 50mm thick RCC 1:2:4 type B-1 cover slab of size 300x300x50 mm as earth lead protection pipe, 50 mm thick RCC (1:2:4) type B-1 cover slab of size 300x300x50 mm as earth pit cover reinforced with 8mm dia TMT bars @ 10cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer, charcoal and testing complete all as specified and directed. Note : (a) Rate quoted deemed to be included of excavation and earthwork in any type of soil with PCC type C-1 in pit PCC cover (b) Earth test result should not less than one ohm.
Supply, install, testing and commissioning of open well type submersible monoblock pump set electric driven three phase 415 volt, AC motor of capacity 10.0 HP with foundation complete with base plate fixing arrangement as per manufacturer's instructions, including civil work complete all as specified and as directed.
Supply and fixing submersible cable suitable for pump motor of size 4 Sqmm, complete all as specified and as directed.
Supply and laying GI tubing medium grade with all fittings and fixed to walls and ceilings or laid in floors of size 50mm, complete all as specified and as directed.
S & F gun metal, globe or gate valve for 50mm with iron wheel head, scewed both ends for iron pipe and fixed existing GI/CI pipe line through leather gasket of suitable thickness including taking down one one, complete all as specified and as directed.
Supply and laying and testing XLPE cable insulated, screened, PVC bedded, wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm, 4 core, complete all as specified and as directed by Engr-in-Charge. Make: As per list of approved make
Supply and laying dry sand of approved quality for cushioning of underground cable laid in trenches 8 cm deep before laying the cable and 15 cm thick after laying and stretching the cable, complete all as specifed and directed. (Note: Punned thickness of sand cushioning only shall be measured and paid for)
M & L for brick protection with old size sub class 'B' brick for PVC underground cable protection in trench with width equal to length of brick laid dry and flat joining each other with gap between adjacent brick not exceeding 10mm over LT underground cable, complete all as specified and as directed.
Supply and fixing GI pipe light grade 50mm bore with all fittings laid in trenches/wall/pole through MS flat (25x3mm) nut bolts and washers (where ever required) of proper sizes for protection of cable, complete all as specified and as directed.
M & L for boring under roads without disturbing the top surfaces of the road for passing through the cable, complete all as specified and as directed.
M & L for Earthing complete with galvanised steel earth plate electrode 600x600x3.15mm thick buried directly in ground (earth pit not less than 2.25m depth below ground level) with top edge of the earth plate not less than 1.5metre deep below normal ground level, connected galvanised strip 32x6 mm thick by means of brass nut, bolt, washer ad protection pipe for earth strip from the earthing plate to the equipments/Panel, (40 mm dia (light grade), GI tubing, funnel, wire mesh, 20mm bore GI tubing (light grade) watering pipe, including concrete pit in PCC(1:3:6) type C-1, precast RCC(1:2:4) type B-1 cover slab of size 54x54x4 cm reinforced with 8mm dia TMT bars @ 15cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size for lifting of cover slab, charcoal and salt in alternate layers including necessary excavation and earth work in soft/loose soil all as shown in Electric plate No. 3 of SSR including disposal of surplus soil to a distance n.exc 50m, complete testing on completion, complete all as specified and as directed.
Supply, install, testing and commissioning LT cubicle type distribution panel, IP-54 (manufactured from CPRI type tested manufacturer) outdoor, type made out of 3.15 mm thick CRCA sheet supported on structural frame, angle or channel, fixed on the ground by galvanised nut and bolts, PCC work (1:2:4) type B-1. The LT cubicle type distribution panel should have enamelled danger notice plate of 1.6mm thick, duly painted with powder coated paint of shade RAL 7032 (internally & externally) complete all as specified and directed by Engr-in-Charge. The LT distribution panel must have stainless steel hinges, with special type of heavy duty stainless steel front and back opening, locking arrangements. The panel should have provision/accomodation of the following electrical items:-
BUS BAR (a) Aluminium bus bar 4 strips (covered with PVC insulated sleeves as per colour code) 400 amps capacity, including connection.
INCOMING (a) Moulded case circuit breaker 4 pole 125 Amps 415 Volts (Vertically placed), 25 kA breaking capacity, Ics=100%, Icu, adjustable overload settings 0.8 -1.0 x In, adjustable short circuit settings 6-10 x in Make- Siemens/ABB/Legrand = 01 No.
OUTGOING (i) Miniature circuit breaker. TPN, 63 Amps, 415 Volts (Vertically placed), Make- Siemens/ABB/Legrand = 02 Nos. (ii) Fully automatic star delta starter of capacity 12.5 Hp with single phase preventor contactor, overload relay, timer etc= 02 Nos. Note:- The connection between MCCB and busbar should be done by Aluminium, bar of suitable ratings all as specified and as directed.
Supply and installing 1.5 ton Hi wall split units indoor/outdoor complete with cordless remote control unit and with in-built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity as shown all as specified and directed by Engr-in-Charge.
Supply and fix voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA.
Swastika Engineers and Agencies
R. D. ENTERPRISE
S.P. TRADERS
M/s Priyanka Construction
KUNDAN ENGINEERS AND BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .