Loading…
Loading…
Tender Value
₹69.1 L
EMD Value
₹1.4 L
Closing Date
26 Jun 2026, 3:00 pm
S&T works in c/w (i) construction of two no. RCC box bridges of size 3.00mX2.50m each at Km 505/4-6 on JUC-ASR section and OHE 6/9-11 on ASR-PTK section by municipal corporation, Amritsar (pushing method for crossing of water pipe) in the jurisdiction of ADEN-II/ASR. (2) RCC boundary wall (as per NR type F-71) and other misc. works in c/w construction of ROB at KM 43/8-9 between RCF halt & sultanpur Lodhi Railway station on JUC-FZR section of project the Railway boundaries.
433-Sig-T-19-26-27
433-Sig-T-19-26-27
Open
6 Months
Sultanpur, Uttar Pradesh
₹0
₹1.4 L
4 Jun 2026
4 Jun 2026
12 Jun 2026
per RDSO Drg. no. RDSO/S-11500 or latest. (Inspection: Consignee)
RDSO drg. no. SA-23741A(Alt 4) & spec. no. IRS-S-75/2006 or latest as applicable. (Inspection: RDSO)
requirement at site and RDSO/SPN/208/2012 version 2.0 Amdt. 1 or latest. (Inspection: RITES)
requirement at site and RDSO/SPN/208/2012 version 2.0 Amdt. 1 or latest. (Inspection: RITES)
Global/Heidz/Pragati make ELB as per requirement at site and RDSO/SPN/208/2012 version 2.0 Amdt. 1 or latest. (Inspected by Consignee)
ELB as per requirement at site and RDSO/SPN/208/2012 version 2.0 Amdt. 1 or latest. (Inspected by Consignee)
per requirement at site and RDSO/SPN/208/2012 version 2.0 Amdt. 1 or latest. (Inspected by Consignee)
FEROZPUR DIVISION-S AND T/NORTHERN RLY
Global/Heidz/Pragati make ELB without hand generator as per requirement at site and RDSO/SPN/208/2012 version 2.0 Amdt. 1 or latest. (Inspected by Consignee)
Global/Heidz/Pragati make ELB without hand generator as per requirement at site and RDSO/SPN/208/2012 version 2.0 Amdt. 1 or latest. (Inspection: RITES)
Siemens (Inspection: RDSO)
LED signal or equivalent without base plate along with guide rail conforming to specification no. IRS: 23-88, S: 34- 68, S: 46 or latest as applicable. (Inspection: RDSO)
LED signal or equivalent without base plate along with guide rail conforming to specification no. IRS: 23-88, S: 34- 68, S: 46 or latest as applicable. (Inspection: RDSO)
signal type or equivalent without base plate along with guide rail conforming to specification no. IRS: 23-88, S: 34- 68, S: 46 or latest as applicable. (Inspection: RDSO)
Siemens (Inspection: RDSO) S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Schedule () C-Supply & Execution items 510067.24
Description:- Supply and installation of earth electrodes pipe of 3 mtrs length and 50 mm dia. pointed on lower end by tapering for a length of 150 mm and connecting with lightening arrester or signaling gears as per std. Practice. The item includes digging of pit in earth, 3 Mtrs. Deep and fixing earth electrode pipe in it. Earth pipe shall be buried in the ground to the length of 2.7 mtrs. after welding 6 SWG wire at lower end and fixing through nut and bolt at top. Casting of cement of Cement concrete enclosures as per drg. No. NR/S&T/CON/6.4/97 or latest if any. The soil treatment
soldering of lead wires. The other end of the earth wire/mild steel flat to be connected to block instrument mild steel flat, cable sheath of power equipment , apparatus case, relay racks, other equipments as per the instruction of Engineer at site & IRSEM. Complete materials such as earth electrodes as per drg. No. NR/S&T/CON/6.3/97, cement, wiring material, soldering material, mild steel flat, soldering of lead wires etc. to be supplied by the contractor. The earthing lead shall be mild steel flat of size 35mmX6mm. In case conductor is buried underground, it shall be protected from corrosion by application of suitable anti-corrosive paint.(Material inspection: Consignee)
Description:- Boring & trenchless cabling along with supply and insertion of Double walled corrugated HDPE pipe as per RDSO spec. no. RDSO/SPN/SPN/204/2011 ver. 1.1 and amendment 1 or
signaling/telecom/power cables under the track/road. The following required coupling arrangement such as- 1. Suitable snap fit couplers with rubber O ring 2. Spacers 3. Tees 4. Bend 5. End cap etc. to be supplied along with the pipe. Work at site shall be inspected by Site engineer & DWC HDPE pipe and associated material to be inspected by Consignee.
NR/S&T/CON/1.1/97-A or latest and as per instructions of the site Engineer. (Bricks to be inspected by consignee) S.No. Item Item Qty Qty Unit Unit Rate Basic Value Escl.(%) Amount Bidding Code Unit Schedule () D-Execution items 202074.38
1 FEROZPUR DIVISION-S AND T/NORTHERN RLY
drg. No. NR/S&T/CON/2.7/97 or latest. All materials such as cement, sand, aggregate and anchor bolts shall be supplied by the contractor. Contractor is required to execute all type of repair works of foundations if required during inserting the cable for termination. (All concrete work must be ratio of cement, coarse sand and aggregate 1:3:6 and outer surface should be plastered with 1:4 cement and sand).(Inspection: Site Engineer)
Description:- Preparation of App. Case Large involving wiring of relays. Work involves following: Preparation & fixing of Bakelite hylum sheet 910x800x6mm and teak wooden shelf 900x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mmx25mmx3mm. Angle iron frame will be fixed in location boxes secured by nuts & bolts. Fixing of fuses, ARA terminal, shelf type Q series relays and other type relays on square bars, fixing and jamming of cables with 2 inch thick salwood plank provided at the
separately for each cable through the salwood plank & all cable entry points on location boxes, location huts, JB's relay room/battery room to be closed with suitable masonry works covered with sand and plastering. Description for terminal drawing of circuits, inside app. Case. Painting from outside as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including hard wood shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specification, non-deteriorating type HRC fuses, bases, nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals only shall be supplied by the railways. (Inspection: Site Engineer)
Description:- Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per drg. No. NR/S&T/CON/1.1/97-A or latest so as not to form a drain 0.3 Mtrs. Wide & 1 Mtr.
signalling and cable plan. It also includes clearance of routes of trees & bushes. Lesser depth due to site conditions shall be paid proportionately after obtaining prior approval from not below than JAG officer.(Inspection: Site Engineer)
Description:- Earth work for excavation & refilling around location boxes and signals etc. where
location to the center of filling & lift from main ground level. The earth work should be well rammed including breaking of clods, levelling and dressing etc as per instructions of the site engineer.
Description:- Concreting unscheduled items in concrete of 1:3:6 ratio in cement, coarse sand and aggregate 25mm at different places in the yard and plastering top in fine plaster of 1:4 cement,
engineer. The volume in cubic meters shall include the volume occupied by any CI foundation, trestle, MS angle or flat or GI pipe required to be embedded in the casting. cement, coarse sand and aggregate 25mm are to be supplied by the contractor. (Inspection: Site Engineer)
(ordinary) mixture of 1:4 ratio. All material is to be supplied by the contractor. (Inspection: Site engineer)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
JPOforProtectionofcablesduringexecuitionofvariousworks_1.pdf JPO for protection of ST cables
ATTACHMENT
IRGCC2022ACS11.pdf
ATTACHMENT
StandardTenderDocument2022.pdf
ATTACHMENT
correctionslip1toSTD2022.pdf
ATTACHMENT
FinalGCC-2022-uptoACS6.pdf
ATTACHMENT
IRGCC2022ACS7.pdf
ATTACHMENT
IRGCC2022ACS8.pdf
ATTACHMENT
IRGCC2022ACS9.pdf
ATTACHMENT
IRGCC2022ACS10.pdf
ATTACHMENT
specialconditionsofwork.pdf
ATTACHMENT
JPOforProtectionofcablesduringexecuitionofvariousworks_1.pdf
ATTACHMENT
Download all tender documents and submit your bid