Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical non responsive |
Tender Value
₹12.3 L
Closing Date
11 Aug 2021, 2:00 pmClosed
Seceratary
UIT ALWAR
Reparing and Maintance Work of Air Cooling and Central A.C. in Rajiv Gandhi, Zanana and Children Hospital
2021_UITAL_235518_6
NIT 08/2021-22
Open Tender
Electrical Works
120 days
UIT ALWAR
Please Refer Tender Document
2 documents required · 2 mandatory
₹500
Seceratary Uit alwar and MD RISL Jaipur
Exempted
27 Aug 2021
2 Aug 2021
11 Aug 2021
2 Aug 2021
11 Aug 2021
2 Aug 2021
Amount
Provide & Replacement of imported cellulose paper pad for existing air- cooling plant Humidification section comprising of Wet pads 200 mm thick impregnaed cellulose paper media ( Celdec pads) of imported origin with 2 bend PVC eliminator, internal casing with blank off's of wet section in SS-304 construction any direction by Engineer Incharge if any required
P&F of Pedestal Braring with dismantling & refitting charge (Micro A&S Classical)
P&F of V- belt with fitting charge Fan Section comprising of belt driven, DIDW backward curved fan with outlet velocity less than or equual to 10 m/s and minium efficiency of 70% AMCA certified centrifugal fan suitable for required cfm at 50 mm static pressure Defect Item
P&F Supply of canvass cloth connection
P&F and Complete servicing and Repairing of air cooling plant with replacement of damage base of Blower, Rubber coating in water tank, overhauling of motor etc. Defect Iteam replace by contractor as per direction of Engineer Incharge
P&F Ball cock PVC Float Valve set with ball solid fitter set ( brass)
P&F Replacement of Submersible pump of existing Air- cooling Plant Damor ECO 40 , 0.5 HP Defect Iteamreplace by contrator as per direction of Engineer Incharge
P&C Complete Servicing of Ductable Air- conditioning plant including washing of Condenser Coil, Cooling Coil, Cleaning of Filters, Top- up of Refrigerant, require complete in all respect direction by Incharge replace of Defected Item
P&F Complete Servicing of VRV Air- conditioning plant including washing of Condenser Coil, Servicing of AHU, Cleaning of Filters, servicing of LAMMINAR FLOW SYSTEM, Top-up of Refrigerant, Complete repect of defect item if any direotion of Engineer Incharge .
16.0 HP ODU-3000 CFM AHU
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid