Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.6 LAccepted-AOC 00 JAI BHAWANI COMPLEX MAIN ROAD SADAR WARD JAGDALPUR BASTAR CHHATTISGARH 494001 UDYAM CG 01 0003803 | BASTAR | CHHATTISGARH | 494001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹7.1 L+₹43,205.23 (6.49%)Rejected-Finance | L2 | Rejected-Finance Other than L1, hence rejected |
Tender Value
Refer Docs
EMD Value
₹12,600
Closing Date
16 Oct 2020, 6:00 pmClosed
AGE (I) Naya Raipur
Military Engineer Services Assistant Garrison Engineer(Independent) Naya Raipur C/O HQ COSA, Near International Cricket Stadium, Atal Nagar, Naya Raipur Raipur(CG)-492101
PROVN OF AIR RELEASE VALVES AND ALLIED SERVICES WORKS OF WATER SUPPLY AT HQ COSA, PROVN OF COVERED SHED BETWEEN STORAGE ACCN BLDG NO T-14 AND T-09 OF 155 INF BN(TA) JAK RIF AND SPL REP TO OLD PUMP HOUSE AT NAYA RAIPUR MIL STN UNDER AGE(I) NAYA RAIPUR
2020_MES_379029_1
8400/271/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) Naya Raipur
Please refer tender documents
7 documents required · 7 mandatory
₹500
AGE (I) Naya Raipur
₹12,600
29 Oct 2020
19 Sept 2020
19 Oct 2020
19 Sept 2020
16 Oct 2020
3 Oct 2020
Amount
Sch 'A' Part-I
Excavation in trenches in any type of soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out for laying of pipe cables etc,. and getting out complete all as specified and directed
Material and labour for DI tubing 150 mm dia K9 type with suitable pressure bearing capacity , with all fittings, connecting with joints ,providing leak proof joints with jointing materials , laid in trenches complete all as specified and directed by engr in charge. Make- JINDAL/SWASTIK/Surya prakash Note- Contractor to check site conditions before executing the works in advance.
Returing filling in, including spreading levelling, watering and well ramming in layers not exceeding 25cm thick with earth obtained from excavation complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Material and labour for construction of valve pit chambers of size 900 X 900 X 900 mm (external dimensions) as under provided with 10 cm thick PCC 1:4:8 type D-2 as in foundation over 15 cm thick hard core, 23 cm thick brick walls built in cement mortar 1:4, 15 mm thick internal plaster including top of floor, externally upto 150 mm below GL in CM 1:3 finished even and smooth without using extra cement, 3.00 mm thick MS sheet cover with 40 X 40 X 6 mm MS angle frame fixed in PCC 1:2:4 type B1, 50 mm thick coping with 25 X 6 mm flat iron hold fasts, hinges, handles, locking arrangements and applying 2 coats of syntheric enamel paint over acoat of red oxide primer to all steel surfaces and 3 coats of white wash to internal surfaces of chamber including excavation and earth work in any type of soil and removing of surplus soil to a distance not exceeding 50 m complete all as specified and directed.
Material and labour for PCC 1:2:4, type B1 using 20 mm graded stone aggregate as in coping, including necessary form work complete as all specified and as directed.
Supply and fix ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed or iron pipes of size 25 mm -455 grms all as per directed and specified by engr in charge
Supply and fix CI air release valves H-7 double orifice flanged ,epoxy coated tamper proof design ,double ends with PN class 1.0 for pipe of dia 150 mm with all fixing arrangements and accesseries ,all as per dircted and specified by Engr in charge .Make Zoloto / Kartar Valves/ Pride
Sch 'A' Part-II
Excavating in post holes in soft/loose soil (or similar holes) each n exc 0.5 cu.m. getting out, returing, filling in and ramming earth or broken ruble mixed with earth around, in layers not exceeding 25 cm , watering, and removing surplus soil to a distance n exc 50 M and making good surface.
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate in foundation, filling & mass concrete all as specified.
S&F steel work in tabular truss and tubelar post including special shaped washer etc .complete using ERW or induction butt welded tubes conforming IS:1161-1979 grade St-240
S&F MS Plates (plaines or chequered) square cut or notched (forming holes with riveted,bolted or welded attechment) Fe 410 -W (Gde -E -250) qyality -B
S & F MS screw bolts (machine made) with hexagonal or square heads at one end and screwed the other,or screwed bothends,each screwed end to be fitted with washers and one hexagonal or square nut,but lenth of bolt exc 5cm but n exc 10 cm
S&F Pre-painted galvalume aluminum zinc coating GI Based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in foof covering/cladding to wall,fixed with self tapping screws as specified
M&L for preparation of new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide primer over 10cm width or girth etc all as specified.
S & F wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 - S & F
Sch 'A' Part-III
Demolition of cement concrete (unreinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) complete.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressedstonework and precast concrete articles - Demolition
M&L for 100 mm thick PCC (1:4:8)type D-2 using 40 mm graded aggregate as in sub base, complete all as per specified and directed by Engr-in-charge
Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) - 75mm thick
Cement concrete 1:2:4 type B0 using 12.50mm graded stone aggregate in floors, 25mm thick, for base of tiles cement complete.
Taking down cement plaster on brick wall or concrete surface etc including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M&L brick work with fly ash brick modular size in cement mortar 1:6 straight or curved on plan exc. 6m mean radius complete and all as specified and directed
M & L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:6) on wall finishing the surfaces even and smooth without using extra cement.
M & L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:4) with using WPC (WPC shall be measured seperetly)on wall finishing the surfaces even and smooth without using extra cement.
M&L for 5 mm thick cement plaster in cement mortar 1:3 for ceiling, finished even & smooth without using extra cement complete all as specified and directed.
M & L Preparing new plastered surfaces and applying two coats of cement base paint over a coat of alkali resistant primer on wall surfaces.
M&L two coat oil distempering on newly plaster surface
M&L three coat of white wash on newly plaster surface on ceiling wall.
M&L two coat of synthetic enamel paint on steel surfaces of any description not otherwise described over 10cm width or girth including preparation of old surfacesand apply a coat of red oxide primer complete and all as specified and directed
Supply only integral waterproofing compound
Repairs and servicing to rolling shutters including removal of worn out components such as hood covers, laths, ball bearing, helical wire spring , lock plate, shafts rods and straightening / replacing of existing guide channels as required incliding greasing and servicing for smooth functioning and refixing in the same opening of any size of rolling shutters complete of any size, all as directed and specified. Note :- Replacement parts shall be measured and paid separately as supply only
Supply only 450 mm long helical wire spring 6 mm
Supply only ball bearing of size 50mm (inner dia).
Supply only mild steel pipe 50mm dia bore medium grade with necessary holes for shaft.
M & L for taking down old cement plaster and cleaning the surface for laying 3 mm thick thick APP based poly meric membrane weighting not less than 3.50 Kgs/Sqm reinforced with polyester non woven fabric (weighing not less than 160gms/sqm) with minium 100mm transverse laps and 75mm longitudinal lap over RCC slab finished wilth 15 mm thick cement plaster (1:3) with WPC all as dpecified and directed. All material shall be of same make and application shall be according to manufactudrer's instrusctions. over cold solvent Bituminous primer @ 0.25 ltrs/Sqm incluading a coat of aluminium paint @ 0.110 Kgs/Sqm over felt. Application of polymeric membarane shall be by LPG gas torching ETC as per manufacturing instruction and complete all as specified as directed. Note : Supply only WPC shall be measured and paid separately under relevant item.
Taking down carefully copper/Aluminum point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, pendants, regulators sockets etc. and making good the disturbed surfaces of walls, floors etc and match with the existing colour of wall complete all as specified and as directed.
Taking down carefully by unscrewing from board/out-let boxes, light fitting, fixture and fittings such as MCB DB with MCB, wooden board, sheet metal enclosure with plug top and MCB etc. complete all as specified and as directed.
Taking down starter any type and depositing it in Mes store after dismantling all accesseries all as per required and directed by Engr In chrge.
M&L Point wiring complete with 1.5 sqmm PVC insulated stranded copper conductor single core cable drawn through and including rigid non metalic PVC conduit 20 mm dia ( meadium grade ) , ISI marked with concealed conduit wiring including cutting chases and making good in CM 1:3 & white/colour wash to match existing surface, pressed steel terminal boxes not less than 1.6 mm thick concealed in wall duly painted with two coat of black bituminous paint over a coat of red oxide primer, plastic laminated top sheet cover 2.8 mm thick of required size and colour for housing switches and sockets, 1.5 sqmm PVC insulated (green insulation) copper conductor as earth continuity cable drawn with wiring and connected to common earth dolly all as specified for -
(a) One light point controlled by one switch
(b) One Fan point controlled by one switch
(c) One socket out let 5 pin 5 Amp on same board
(d) s/scocket combination 5 pin on independent board
All as per item No 03 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed cable for 3/6 pin 5 & 15 Amp socket outlet controlled by one switch on independent board with and including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed.
S&F Switch piano flush type polycarbonate , Single pole, one way, 6 amps, 230 Volts, specified make
S&F socketoutlet 2in 1-5 pin , Single pole,polycarbonate one way, 6 amps, 230 Volts, specified make
S&F socket outlet 2 in 1 5 pin combination polycarbonet, Single pole, one way, 16 amps, 230 Volts, specified make
S and fix independent board 5 pin S/Socket combination all as per required.
S/F Ceiling rose surface type bakelite, two or three terminal
S & F MCB DB epoxy powder coated distribution box SPN, 4 ways, 240 volts, for MCB double door , grouted flush to walls with IP 43 and metal door complete all as specified and directed.
S & F SP, 6 to 32 Amps, 240 Volts , 10 KA , 'c' curve MCBs complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S & F SPN, 32 Amps, 240 Volts , 10 KA , 'c' curve MCBs complete all as specified and directed :- (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixing Wall mounting indoor decorativeLED T-8 batten with opel diffuser 1x 18 W LED tub light mounting over two nos of round wooden blocks complete with , tube and all accessories making electrical connections with twin core PVC flexible copper wire of size 0.50 sqmm upto 1.5 mtr length complete. Make - Philips/Wipro / Oshram
Supply & Fixing exhaust fan 300mm sweep PVC type 240 volts complete all as specified and directed. Make Orient/USHA/CG
Supply and fix building security light of 18watt IP 65 watt,LED die casting aluminium with LED street optic lenses ,efficacy of skyline plus is upto 120lm/w, with pea nut lenses LED type with bracket arrangement all as per required and directed by Engg in Chrge MAke - Wipro Cat No LR13-241-XXX-57-XX or equivalent in Philips/Oshram
Supply/Laying or fixing or passing through pipe, jointing and testing 1100 volt grade XLPE insulated armoured heavy duty PVC insulated, PVC sheathed armoured electric cables with aluminum stranded conductor, 35 sqmm 3.5 core complete all as specified and as directed .
Excavation in trenches in any type of soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out for laying of pipe cables etc,. and getting out complete all as specified and directed
Returing filling in, including spreading levelling, watering and well ramming in layers not exceeding 25cm thick with earth obtained from excavation complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Material and labour for dry river washed and screened dry sand for filling in trenches below and around the cable for cushioning including punning down as specified in relevant clause of SSR Part I. Note:- Punned thickness shall only be measured and paid.
Supply and lay bricks sub class 'B' laid dry abutting each other with gap between adjacent slab not exceeding 10mm over UG cable as in cable protection all as directed.
Material and labour for PCC 1:2:4, type B1 using 20 mm graded stone aggregate as in coping, mud stops, benching, etc. on around poles, chajjas and weathering, slightly rounded or chamfered angles, throating etc. including necessary form work complete as all specified and as directed.
S and Fix Star Delta starter for 17.5 HP/20 HP submersible pumpIP65 AC combiner Feeder Pillar, the high flexibility of the modular enclosure system allows an easy upgrading of the assembly including bus bar system at any Fme even aHer many years , made of high quality Polycarbonate PC - GFS (shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, self-exFnguishing, having high impact against mechanical load, made of halogen and silicon free recyclable material conform to RoHS direc/ve 2002/95/EC, UV resistant according to IEC 61439-1, having high grade internally embedded gasket made of Polyurethane ( PUR ). All leH or right side enclosures should have pre-moulded knockouts for side cable entry or for future extension. Each enclosure should have mulF no of self-threaded holes to mount mounFng plate or Din channel or any equipment. The feeder pillars should have following in built safety features:In this type of feeder pillars electrical funcFons are to be monitored must be visible. The enFre system should have de-touchable lid with pad locking arrangement and incomer should have hinged type lid and it can be combinaFon of transparent or opaque lid. All lids should have triangular type locking arrangement or should have Mi pad locking arrangement for posi/ve isola/on. The bus bar system should have EMC compliant. To provide grounding / earthing in connecFon metal plate should be provided inside polycarbonate flange for armoured cable ( SWA – steel wired armoured cable) via glands in accordance with BriFsh Standard ( IS: 5039 ).The feeder pillar should have following test cer/ficate 1. In accordance with IEC 60 439-1 (IS8623) at ASTA ( CPRI Bhopal Laboratory ) and IEC 60 439-2 for power switchgear and control gear assembly. The party must be submi`ed rouFne test cerFficate from manufacturer/principal company in accordance with IEC 60 439-1. The type test report as per CPRI ( in accordance with IEC 60 439-1 ) should consist with following: i) Degree of protecFon of system (ii) Temperature Rise Limi tiii) Dielectric ProperFes (iii) Short Circuit Withstand Strength (iv) EffecFveness of protecFve circuit (v) Clearance and creep-age distance (vi) Mechanical OperaFon 2. Should withstand glow wire test at 9600C in accordance with IEC 60 695-2-11 UL subject 94, should be flame retardant and self-exFnguishing in nature. 3. Degree of protecFon against mechanical load IK 08 (5 Joule) ) in accordance with accordance with EN IEC 62262 4. Rated insulaFon voltage should be 690V AC as per IEC 60664.
S and Fix changeover of capacity 100 Amps with enclosure confirming to IS 13947 IES 60947-3 on load changeover four pole all as required and directed by engg in chrge Make HPL Code IHCNFO0100 or equivaelnt in L&T / Havells
S and fix VTPN DB 4 way with following : IP66 ( in accordance with IEC 60 529) AC combiner Feeder Pillar, the high flexibility of the modular enclosure system allows an easy upgrading of the assembly including bus bar system at any Fme even aHer many years , made of high quality Polycarbonate (shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, self-exFnguishing, having high impact, made of halogen and silicon free recyclable material conform to RoHS direc/ve 2002/95/EC ). The DB shall have high grade gasket made of Polyurethane ( PUR ) Dependent on the System: Environmental condiFons for distribuFon boards according to IEC 61439-3: -5 °C up to 35 °C, max. + 40 °C; humidity: 50% at 40 °C, 100% at 25 °C for empty enclosures: - 25°C up to + 70 °C. Enclosure should be totally insulated, protecFon class II. And rated insulaFon voltage should be 690V AC as per IEC 60664.The LDB shall have following cer/ficates and safety features: Weather proof: UV resistant according to IEC 61439-1 IEC 60 695-2-11: should withstand glow wire test at 9600C UL subject 94, should be flame retardant and self-exFnguishing in nature. IEC 61 439-3: Intended to be operated by ordinary person. The party must be submi`ed rouFne test cerFficate from manufacturer/principal company in accordance with IEC 61 439-1. To provide grounding in connecFon metal plate should be provided inside polycarbonate flange for armored cable ( SWA – steel wired armoured cable) via glands in accordance with BriFsh Standard ( IS: 5039 ). The enFre system should have hinged door and it can be combinaFon of transparent or opaque lid. All the doors should be lockable type / door fasteners for tool and hand operated.I/C 100 Amps MCCB, O/G 63 Amps MCB TPN -02 Nos , 20 Amps SPN 02 Nos bus bar of suitable capacity and fixing in wall in conceled position all as required and directed by engg in chrge
M and L for repair to submersible supply assembly , dismantling the flange/joint and repairing leakeges any type and assembling it after rectifying all defects/leakages,making it functional for water discharge ,all as per required and directed by engg in charge
Material and labour for earthing complete with galvanised steel plate earth electrode 600 X 600 X 6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected with 25x4 mm galvanised steel strip at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/ dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6, type C-I, using 20mm grade stone aggregate and MS angle iron frame 40 x 40 x 6mm, RCC 1:2:4, type B-1, using 20mm grade stone aggregate, 50mm thick pit cover, reinforced with 8mm dia TMT bars, 75mm centre to centre both ways, MS handle 12mm dia, PGI funnel, wire mesh and GI pipe of 20mm bore (light grade) and earth lead protection pipe 15mm bore (light grade) and all as shown in electrical plate No. 3 of SSR Part-I including testing complete all as specified and directed. Note:- GI wire and protection pipe up to 7.5 metre beyond the earth plate electrode is included in unit rate quoted.
Total contract sum shall be calculated after deduction of schedule of credit amount of Rs. 1756.00
M/S INDIA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .