Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC NO 9 LAKSHMI NIVAS SOMASHETTAHALLI CHIKKABANAVARA POST BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹31.0 L+₹48,066.02 (1.57%)Rejected-Finance NO 26 SRI GANESH 7TH CROSS BDS NAGAR DIBBUR RAMAIAH LAYOUT K NARAYANPURA MAIN ROAD BANGALORE 560 077 | BENGALURU URBAN | KARNATAKA | 560077 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 3 | L3₹31.4 L+₹87,764.24 (2.87%)Rejected-Finance NO 92 KUVEMPUNAGAR 2ND STAGE JALAHALLI EAST BANGALORE 560 014 | 560014 | L3 | Rejected-Finance Rejected. Quoted rates are higher than L1 | |
| 4 | L4₹33.2 L+₹2.7 L (8.75%)Rejected-Finance H NO 243 VARADARAJ NAGAR VIDYARANYAPURA POST BANGALORE 560 097 | BANGALORE | BANGALORE | KARNATAKA | 560097 | L4 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹66,000
Closing Date
2 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli Bangalore 560013
8718PROVN OF CERTAIN B R AND E M MINOR REVENUE WORKS IN EAST AREA UNDER GE M AF JALAHALLI BANGALORE
2022_MES_566036_1
8718/E8
Open Tender
Civil Works
Item Rate
152 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT PUBLIC FUND ACCOUNT
₹66,000
25 Feb 2023
29 Nov 2022
4 Jan 2023
29 Nov 2022
2 Jan 2023
14 Dec 2022
29 Nov 2022 - 6 Dec 2022
Amount
Excavation in trenches n exc 1.5 m wide and n exc 1.5 m depth in hard/dense soil. for foundation etc or for shaft, wells, manholes, pier holes etc n exc 10 Sqm on plan and not exc 1.5 m in depth and getting out complete all as specified and directed
Excavation in trenches n exc 1.5 m wide and n exc 1.5 m depth in soft and loose soil for foundation etc or for shaft, wells, manholes, pier holes etc n exc 10 Sqm on plan and not exc 1.5 m in depth and getting out complete all as specified and directed
Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate for foundations / filling around the post all as specified and as directed.
Material and labour pre-cast PCC 1:3:6 type C1 (20 mm graded agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:4 .
Material and labour rendering 10 mm thick cm 1:6 on brick /concrete surfaces finsihed even and smooth without using extra cement
Material and labour rendering 15 mm thick cm 1:4 on brick /concrete surfaces finsihed even and smooth without using extra cement
Material and labour for preparation of new plastered wall surfaces of any description and applying three coats of white wash as specified and directed
Material and labour for preparation of new plastered wall surfaces of any description and applying two coats of cement base paint and all as specified and directed
Removal of surplus material to a distance not exc 50 m and deposited where directred at a level not exc 1.50 m above starting point
Returning fillin in, including spreading, leveling,watering and well ramming in layers n exc 25cm all as spd and directed.
Material and labour Hard core of gauge n.exe.63mm with broken stone boulders, deposited spread and levelled in layers not exe 15 cm thick watered and rolled rammed to a true surfaces
Material and labour for 75mm thick cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) as in sub base/ plinth protection all as specified and directed.
Material and labour for 15 mm thick screed bed in cement mortar 1:4 for laying floor finishes under floor.
Material and labour for non skid coloured joint free tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and all as specified and directed.
Material and labour for rendering 10mm thick in CM 1:3 on brick work or concrete surfaces as in backing coat to receive wall tiles etc.
Material and labour for ceramic coloured tiles of size 300x200mmx7 to 8 mm thick, on verticals surfaces, set and jointed inneat cement slurry and pointed in coloured / white cement to match the tiles and all as specified and directed.
Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting in soft /loose soil
Material and labour for 100 mm thick PCC 1:4:8 type D2 as in sub base, pavings, mass concrete all as specified and directed .
Supply and fixing steel ventilators with top hung shutter including hinges, steel pegs, stay etc complete all as specified and directed.
Supply and fixing 4mm thick frosted glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane and all as specified and directed.
Material and labour for Framed Mild steel work as in angle Iron, Channel section,flat Iron for fixed indepently connecting purlin, rafters, MS plate as reqd forming holes bolted and welded attchment and curved shaped by welding (thickness of metal n.exc.6mm) making jointless by filling including cutting etc complete all as specified.
Supply and fixing for galvalume sheets AZ-150 having pitch 190mm, depth 29mm and thickness not less than 0.50mm (Galvalume base- trapezoidal profile sheets) fixed with aluminium self staging screws of size 50/75mm and aluminium washer of suitable size in roof covering, gutters and cladding all as specified. (Over lap shall be as specified by manufacturer)
Material and labour for preparing of new steel surface of any description not otherwise described over 10cms width or girth and applying 2 coats of synthetic enamel paint over one coat ofred oxide primer complete all as Spd and as directed.
Material and labour for 20 mm bore steel tubes “medium grade” galvanised with all fitting and fixed complete in walls ceiling or laid in floors.
Material and labour for 15mm bore steel tubes “medium grade” galvanised with all fitting and fixed complete in walls ceiling or laid in floors.
Material and labour for Bib taps cast copper alloy fancy type chromium plated 15mm bore fixed complete
Supply and fixing PVC High or low level flushing cistern 10 liters capacity (exclusive of brackets), and connections to pipes and fixing of chain and pull, or lever,Joint between flushing pipe and socket of W.C. pan pre-made, if any complete all as specified and as directed.
Supply and fixing vitreous china wash down water closet (pedestal pattern) white with "S" or "P" trap (excluding flushing cistern and flush pipe) including new PVC seat cover and all as specified and directed.
Supply and fix wash basins, vitreous China (flat back or angle back type) size 550x400 mm, including cutting for and pinning in ends of brackets or erecting stand including waste pipe complete all as specified and as directed
Supply and fix vitreous China urinals, Half stall type white (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed.
Supply and fixing Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (minimum wt 60 gms)
Supply and fix 15 mm bore fancy type pillars taps chromium plated cast copper alloy with capstan head, long screwed shanks complete all as specified and as directed.
Supply and fix waste coupling of PTMT (half or full threaded) Minimum weight 32mm- 45gms complete all as specified and as directed.
Supply and fixing in tubular towel rail alumunium annidised 20mm dia 'D' type 60cm long between flanges and all as specified and directed.
Supply and fixing in Grating doom 150 mm dia with waste hole of PTMT. (Minimum weight 100gms) complete all as specified.
Supply and fixing stop/angle valves cast copper screwed down high pressure fancy type screwed both ends for pipe or union fixed for 15mm bore complete
Supply and fixing PVC connection 15 mm bore, 450 mm long complete with both ends unions.
Supply and fixing in 75 mm bore PVC (SWR) floor trap with grating incl jointing with solvent cement
Supply and fixing Rotational moulded Polyethylene water storage tank - 500 liters capacity (cylidrical vertical with double layered, threaded top cover) hoisted and fixed in position all as specified in SSR part I.
Supply and fixing 20 mm dia gun metal gate valve with Iron wheel screwed both ends for Iron pipe .
Supply and fix 110mm dia PVC (SWR) pipe single socket in any length with rubber ring joint fixed to wall or laid in trenches complete all as specified and as directed.
Supply and fix 75mm dia PVC (SWR) pipe single socket in any length with rubber ring joint fixed to wall or laid in trenches complete all as specified and as directed.
Supply and fix PVC cowl 110 mm dia complete all as specified and as directed.
Supply and fix 110mm dia PVC bend any radius complete all as specified and as directed.
All as per item No 46 above but 75mm dia
Supply and fixing PVC (SWR) bends of any radius with access door bore of pipe 75 mm
All as per item No.48 above but bore of pipe 110 mm with access door
Supply and fixing PVC (SWR) junction single(single T) equal or unequal with access door bore of pipe 110 mm
Supply and fixing PVC (SWR) reducers 110 mm
Plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in bed to drain pipes of bore 110 mm bore including packing under and haunching against the sides of pipes after they are laid and tested.
Taking down Chowkhat or frames exceeding 1.5 Sqm and n.exc 4.00 sqm each with shutters(Without taking off shutters from the frames).
Supply and fixing Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube supplying & fixing in opening all as specified and directed
Supply and fixing Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with wood free EPS with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site all as specified and directed
Supply and fixing 150 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed
Supply & Fixing 125 mm Aluminium handles, cast type, anodised
Supply and fixing Butt hinges, medium weight coldrolled mild steel and fixed 100mm size.
Supply and fixing 250 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed
Supply and fixing for CP brass health faucet alongwith flexible pipe and stay complete all as specified and directed.
Supply and fixing in Brass chromium plated 2-in-1 tap 15mm bore for fixing of health faucet.
Supply and fixing in PVC waste pipe 32mm bore for WHB
Supply and fixing roller blinds of 100% polyster blackout fabrics of weight of 310 g/m^2 (+-5%) having a fabric thickness of 0.45mm(+- 0.05) and very high tearing strength with roller mechanism and aluminium channel. Color and pattern to be decided as per direction of Enginneer in Charge , and making good the disturbed surfaces complete all as spfd and dirctd.
Supply and fixing powder coated any colour (minimum thickness of powder coating 50 micron) annodised aluminium frame of doors, windows and partitions with one or more rebates including joining cleat for fixing etc and all as specified and directed.
Supply and fixing 5mm thick prelam PVC sheet in stirrups and channels feathered at the edges inclusive of all arrangements for fixing to aluminium frame work partition complete all as specified and directed.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed
Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete rail ings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizon tal or sloping and similar work exc 5cm but n exc 10cm wide complete all as specified and directed
Material and labour for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
Material and labour for reinforced cement concrete 1:2:4 (using 20mm stone aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed
Material and labour for 10mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete sur faces finished even and smooth using water proofing compond. Note: Water proofing compound shall be paid seperately
Supply only integral water proofing compound
Supply and fixing of three layer 2000 litres rotational moulded polye?thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed
Supply and fixing of ball brass valves, high pressure, with polythene float and flynut complete, screwed for 25mm bore of iron pipe or brass ferrule and fixed
Supply and fixing of stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for 20mm dia bore of iron pipe or for unions and fixed
Excavating in post holes (or similar holes) each n exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm in soft / loose soil complete all as specified and direceted.
Material and labour cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone agg as in foundation filling or for mass concrete for posts and complete all as specified and directed.
Supply and fixing MS work as in gates and fencing post and struts including cutting tops to shape as directed ,including imbeding in concrete and all necessary drilling holes,bolting or riveting,welding,notching for wire etc and similar work conforming to grade Fe-410 or Fe-310 complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, any size and type to any type of standards, rails, straining bolts etc and all as specified and directed.
Supply only in chain link MS galvanised fencing any size and all as specified and directed
Supply and fixing in galvanised two strand steel barbed wire 2.24 mm dia barbed wire with 2 mm barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossing with and provision of galvanised MS wire staples or steel pins etc as directed (each line wire to be measured)
Supply and fixing MS round bars/strengthening bar 10mm dia & over cut to length bent to shape required incl cranking bending spirally for hoping for colm & backing ends and binding with & include MS wire (aheaded ) not less than 0.90 mm dia or securing with clips quality confirming to Fe-410W(grade E-250)Quality A or Fe 290 (gde-E-165).
Surface excavation n.exc 30cm deep and averaging 45cm deep and getting out soft/loose soil complete all as specified and directed
Material and labour for broken stone or boulders hardcore of gauge n. exc. 63 mm , deposited, spread and levelled in layers n. exc. 100cm thick, watered and rammed to a true surface complete all as directed.
Material and labour for 100mm thick cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) as in sub base all as specified and directed.
Material and labour for machine pressed precast concrete interlocking paver blocks of 80mm thick (M-40 grade) as in flooring of any shape and size(laid in pattern as decided by GE) and filling the joints with fine sand and all as specified and directed.
Material and labour for 50mm thick sand filling under precast interlocking paver blocks and all other similar works complete all as specified and directed.
Material and labour for providing, cement concrete type B-0, 1:2:4 (using 12.5mm graded stone aggregate) as in kerbs stone, rounded or chamfered on edges
Material and labour providing cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in bands, copings, bed plates, kerbs, water froughs and the like including weathering slightly rounded or charmfered angles and throating complete all as specified and directed by EIC.
Material and labour for point wiring for one exhaust fan using approved wire colour code as per IS (Red, Black and Green for single phase circuits) with multistrand copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked including with valid CM/L No. drawn in PVC conduit/casing-caping rigid, 20 mm non metalic conduit including mild steel/PVC modular sunken box including inner/outer sheet and fixed concealed covered etc including PVC insulated multi-stranded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continiuty conductor to common earth and connecting to earth dolly complete for one light/Fan point controlled by one 5/6 amps one way switch complete all as specified and as directed by Engr-in-charge.
All as per item No 88 here -in- before but for one exhaust fan point with cabel 1.5 sqmm size . complete all as specified and directed.
All as per item No 88 here -in- before one 3/5 pin socket outlet 5/6 Amps 2-in-1, on independent board. complete all as specified and directed.
All as per item No 88 here -in- before one point 3 pin/ 5/6 pin socket outlet point 15/16 Amps 2-in-1, independent board with copper wire 4 sq mm size complete all as specified and directed.
Material and labour for point wiring with two runs of FRLS PVC insulated sheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20mm on surface including provn of pressed steel terminal box of suitable size with 3mm thick plastic laminated sheet cover for mounting switch, socket and regulator along with earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm all as specified and directed one light point controlled by one switch one way 5 Amps .
All as per item no. 92 but here-in-before One exhaust fan point controlled by one 5 Amp switch complete all as specified and directed.
All as per item No 92 herein before but one wall fan point control by one switch 5Amps and regulator complete all as specified and directed.
All as per item No 92 herein before but for using four sqmm for one 3/5 pin 15 Amps socket outlet on indipended board and multistranded insulated with one copper earth continuty conductor of size 4 sqmm all as specified and as directed
M&L for point wiring with two runs of FRLS cable PVC insulated unsheathed 1100 volt copper pvc single core multistranded copper cable 1.5 sqmm grade in and including in stove enamelled steel conduit 20 mm with all accessoried along with fixing arrangements on surface/ in wall/ on ceilling/ including suitable rectengular metal sunken box with top cover/ cover plate thick, hard type fixing on wall surface for fix switches/ sockets/ regualtors etc all as per site require with 1.5 sqmm PVC insulated single core multistranded copper cable earth continuity conductor connecting to common eatrh dolly complete for one flame proof light point all as sprcified and directed.
All as per item no 96 but herein before one flame proof exhaust fan point controlled by one 5 amp switch
Supply and fixing Modular Socket, 6A - 2/3 pin combined 2 module, multi purpose universal pattern 230 volts all as specified..
Supply and fixing Modular switch 1 way 16A, 1 module complete all as specified and directed.
Supply and fixing Modular socket 6/16 A, - 2 / 3 pin comb 2 module all as specified and directed.
Supply and fixing Switch Socket 6A/16A - 2/3 pin combined 2 module multi purpose universal pattern 230 volts all as specified.
Supply and fixing switch piano flush type single pole one way 5 Amps 230 volts complete all as specified and directed.
Supply and fixing Modular switch 1 way 6A, 1 module complete all as specified and directed.
Supply and fixing ceiling rose surface bakelite 3 terminals 65x50mm complete all as specified and directed.
Supply and fix PVC ceilling rose 2 to 3 plate surface and jumbo type complete all as specified
Supply and fixing testing and commissioning Exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep, Heavy duty, copper winding including with blades, frame, louvers, wire mesh, clamps nut-bolts, washer etc for suitable fixing complete all as specified and directed by Engr-in-Charge.
Material and labour for making of hole in stone masonary wall of appropriate size to fix the exhaust fan 450 mm and grouting of bolts, giving suitable shape and making good the disturbed surface with cement mortar plastering, of hole and matching with existing surface color etc complete all as specified and directed by Engr-in-Charge.
Material and labour for sub main wiring 6 sq mm with two single core stranded copper conductor unsheathed PVC insulated multistranded cable 1100V grade drawn through PVC pipe and including 20mm size of PVC rigid conduit with 6 sqmm copper conductor multistranded cable as earth conductor and run on wall with conduit accessories fixed up on surface/ recessed as required, including connecting up complete all as specified and directed. Note:-Two run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
Supply and fixing MCB DB(distibution board) 4 Way 200 Amp double door SPN(single pole and neutral) single phase made sheet steel cement spill protector , isolated neutral bar, IP:54 protection door earthing Mechanical impect strength IK 09, 240 volts and connection complete all as specified.
Supply and fixing MCB distribution board single pole and neutral 4 way factory single phase Double Door made sheet steel, phosphates, powder painted with 200 Amps rated bas bar, 240 volts, neutral link, earth bar and Din rail double door complete all as specified.
Supply and fixing 32 Amp SPN( single pole & neutral) rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and as directed.
Supply and fixing 5 to 32 Amp SP(single pole) rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and as directed.
Material and labour for Tubes, 'light grade' galvanised, size 50mm bore with all fitting and fixed red beacon light top on pole with brazing or fix with clamp, nut-bolts etc accessories, as per site require complete all as specified and directed.
Supply and Fixing in top mounted Red Beacon LED Light fitting Round shape, Water Resistance, maintainance free 6465 series LED beacon pulse 8 flash pattern (8 flashes per cycle , 85 FPM)producing warning signal , the long life LED technology complete with fixing accessories top on on pole/pipe and electric connection complete all as specified and directed. Make :CE Model: Ecco 6465R Beacon or Equivalent.
Material and labour for sub main wiring with two single core stranded copper conductor unsheathed PVC insulated multistranded cable 1100V grade, 1.5sq mm drawn through and including 20mm size of PVC rigid conduit with 1.5 sqmm copper conductor multistranded cable as earth conductor and run on wall with conduit accessories fixed up on surface/ recessed as required, including connecting up complete all as specified and directed. Note:-Two run of cable and one run of earth continuity copper conductor and non metalic PVC conduit shall be measured as one unit length.
Supply and fixing MCB DB(distibution board) 2 Way SPN(single pole and neutral) single phase, single door 240 Volt made sheet steel cement spill protector , without bus bar, IP:54 protection door earthing Mechanical impect strength IK 09, 240 volts and connection complete all as specified.
Supply and fixing LED lights fitting 1x20W, 4 feet 220V AC decorative box Square Profile type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 4 feet, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. complete all as specified and directed .
Supply and fixing LED light fitting 1x30 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat rsistant toughened glass, with LED tube light fixtures driver,holders, connector etc.Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size and fixing accessories with electric connection complete all as specified and directed
Supply and fixing LED light fitting 2 feet, 1x10 watt mirror type with high out put diffuser 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as per site required and as directed by Engr-in-Charge.
Supply and fixing flame proof Exhaust fan of size 300mm , single phase,230 volt, 50 Hz Heavy duty aluminium with net/louver outer all accessories pre wired including make necessary suitable hole by stone/bricks cutting machine, fixed with clamp, nut-bolt and make good disturbed surface area and electric connection complete all as specified and as directed.
Supply and fixing MCB SP 6 to 32 Amps SP 10 KA,50HZ, 240V, 'C' Series complete all as specified and as directed.
Supply and fixing MCB SP 6 to 32 Amps SP 10 KA,50HZ, 240V, 'B' Series complete all as specified and as directed.
Supply and fixing wall mounting fan of 400 mm, 5 star rated,single phase,230 V,50 Hz with all accessories pre wired including necessary electric connection all as specified and as directed.
Supply and fixing MCB DB(distibution board) 4 Way SPN(single pole and neutral) single phase made sheet steel cement spill protector , isolated neutral bar, IP:54 protection door earthing Mechanical impect strength IK 09, 240 volts and connection complete all as specified.
Supply and fixing MCB SPN 32 Amps, 10 KA,240V, 50Hz, 'C' Series single pole&Neutral complete all as specified and as directed.
Supply and fixing Industrial earth plug & socket Single pole and neutral enclosure with a two pin and earth plug & socket with one MCB 32 Amps, fixed for connection of power equipment/System on wall and making all connections all as specified and as directed.
Supply and fixing LED Building security light fitting 60 watts with cast aluminium housing, toughened glass diffuser, IP 65 and wired including suitable size GI bracket made light grade pipe & clamps-02 Nos with bolts & nuts with all accessories for fixed at site and eletric connection complete all specified and as directed.
Material and labour for New Earthing for DBs with Galvanised Iron earth plate electrode size 60cm×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, and connected with 4.0mm GI Wire as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No. 5 connected to earthing test point all as specified including necessary excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with GI protection pipe and indicated testing on completion all as specified and directed by Engineer-in-Charge.
Material and labour for New Earthing for Power Equipments with Copper earth plate electrode size 60cm×60cm× 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, and connected with 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No. 5 connected to earthing test point all as specified including necessary excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with GI protection pipe and indicated testing on completion all as specified and directed by Engineer-in-Charge.
Material and labour for Brazing of copper/Aluminium/GI strip each joints for continuity of earthing connect with equipment/ system complete all as specified and as directed.
Material and labour for Earth continuity conductor 4.00 mm dia GI wire as main earthing lead fixed to wall with clamps with nut-bolts and brazing at each joints or recess or chases or buried in ground or any other indicated situation for earthing etc. where required complete all as specified and as directed.
Material and labour for Earth continuity conductor copper strip size 20x3mm as main earthing strip fixed to wall with saddle/ insulator/ PCC block with nut-bolts and brazing at each joints or recess or chases or buried in ground or any other indicated situation for earthing etc. where required complete all as specified and as directed.
Material and labour for Earth continuity conductor Aluminium strip size 25x3mm as main earthing strip fixed to wall with saddle/ insulator/ PCC block with nut-bolts and brazing at each joints or recess or chases or buried in ground or any other indicated situation for earthing etc. where required complete all as specified and as directed.
Supply and fixing Air termination, single pointed aluminium rod 12mm dia and 300mm long fixed with accessories complete all as specified and directed
Material and labour for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw fixed complete all as specified and as directed.
SRI GANESH ENTERPRISES
BYRAVESHWARA CONSTUCTION
chowdeshwariconstructionco
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .