Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹35.1 LAccepted-AOC | L-1 | Accepted-AOC Accepted | |
| 2 | L-2₹35.7 L+₹61,505 (1.75%)Rejected-Finance | L-2 | Rejected-Finance High Rates | |
| 3 | L-3₹42.2 L+₹7.1 L (20.3%)Rejected-Finance | L-3 | Rejected-Finance High Rates | |
| 4 | L-4₹42.4 L+₹7.3 L (20.9%)Rejected-Finance | L-4 | Rejected-Finance High Rates | |
| 5 | L-5₹43.3 L+₹8.3 L (23.6%)Rejected-Finance | L-5 | Rejected-Finance High Rates |
| Sl No | Description | Qty | Unit | Ms Kailash Chandra Babulal L1 | Vinayak Trading House L4 | MODI CORPORATION L3 | SAHYOG ELECTRIC L2 | Swasti Electricals L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Comprehensive maintenance of ceiling fans/ exhaust fans/ wall fans and connected electric circuit, tightening of loose wiring/ conduits/ fan capacitors and connection carrying out minor repairs incl blade alignments, screwing/ tightening the nuts/ bolts/ washers, cleaning, greasing, fan cap, flexible conduit, incl taking down & refixing properly in the existing position after minor repairs complete all as specified and directed. | 1,000 | Each Job | 52 ₹52,000 | 45 ₹45,000 | 55 ₹55,000 | 28 ₹28,000 | 25 ₹25,000 Lowest |
| 2.00 | Comprehensive day to day maint of the defects pertaining to internal electrification of any type and nature such as taking down defective MCBs / MCB DBs/ TPN/ TPN DBs any type, switch/ socket/ ceiling rose/ holders/ fittings/ fixtures/ building security lights/ Gate light/ Garden light etc. rectification of faulty electric circuits, tightening of loose connections etc. complete all as specified and directed. | 2,000 | Each Job | 55 ₹1,10,000 | 50 ₹1,00,000 | 55 ₹1,10,000 | 32 ₹64,000 | 16 ₹32,000 Lowest |
| 3.00 | Comprehensive maintenance of Geyser of any type or any capacity and nature such as taking down defective geyser any type, removing from existing location, releasing air lock or checking & replacing heating element/ thermoastat/ indicator/ PVC connection/ geyser plug top/ 15 Amps switch & sockets, rectification of faulty electric circuits, tightening of loose connections etc. complete all as specified and directed. | 1,000 | Each Job | 79 ₹79,000 | 90 ₹90,000 | 55 ₹55,000 | 35 ₹35,000 | 25 ₹25,000 Lowest |
| 4.00Note for Ser. NO. 1, 2 & 3:- (a) All T&P and labour team required comprising the Nos of trained electricians & helpers will be provided by the contractor daily as directed. (b) Rep of the contractor will present in complaint cell & responsible for receiving & attending the complaints from 08.30 Hrs to 04.30 Hrs at daily the time of lodging the complaint. In absence of rep of Contractor penel recovery will be charged @ 100 Repees to be deducted per complaint not attended within 24 hrs from lodging by any method/ telephonically. (c) Cost of minor stores such as screws, clamps, insulation tapes, nuts/ bolts, nail etc. of required size shall be deemed included in the above quoted item. However, major items such as point wiring any type, switches, sockets, bell push, fan regulator, SPN/ SP/ DBs and geyser parts etc shall be measured and paid separately under appropriate items of Schedule 'A'. (d) Complaints where complete replacement of faulty circuit/ point wiring required, shall be measured under relevent item. | ||||||||
| 5.00 | Supply and fix in repair of PCB with sensor for BLDC fan suitable for exisiting BLDC fan PCB as per sample complete all as specified and directed. | 80 | Each | 280 ₹22,400 | 390 ₹31,200 | 300 ₹24,000 | 195 ₹15,600 Lowest | 250 ₹20,000 |
| 6.00 | M&L for single pole and earth encolsure with a two pin and earth plug with socket 240 Volts, 50 Hz complete with onesingle pole MCB SP 20 Amps including necessary provision for inserting the same in wall by cutting the brick/ stone masonry etc and making good of disturbed surface to match with existing colour of wall complete all as specified and directed. | 30 | Each | 750 ₹22,500 | 1,000 ₹30,000 | 850 ₹25,500 | 580 ₹17,400 Lowest | 850 ₹25,500 |
| 7.00 | S&F in repairs metal clad plug and socket (male and female) two pin and with earth, 240 volts, 50 Hz complete all as specified and directed. | 50 | Each | 80 ₹4,000 | 150 ₹7,500 | 80 ₹4,000 | 58.2 ₹2,910 Lowest | 160 ₹8,000 |
| 8.00 | Supply and fix LED inverter type bulb of 9 watt, of base B-22 CDL, suitable for fixing in lamp holder including taking down old unsv complete all as specified and directed. | 30 | Each | 280 ₹8,400 | 350 ₹10,500 | 290 ₹8,700 | 210 ₹6,300 Lowest | 280 ₹8,400 |
| 9.00 | S&F for energy efficient exhaust fan havey duty of 300mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12mm dia embedded in the wall including taking down old unsv fand and deposit the same in the MES store complete all as specified and directed. | 20 | Each | 1,750 ₹35,000 Lowest | 1,950 ₹39,000 | 3,000 ₹60,000 | 2,950 ₹59,000 | 1,960 ₹39,200 |
| 10.00 | S&F for energy efficient exhaust fan havey duty of 380/ 450mm sweep as per site requirement made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12mm dia embedded in the wall including taking down old unsv fand and deposit the same in the AGE E/M-III store complete all as specified and directed. | 2 | Each | 3,000 ₹6,000 | 3,200 ₹6,400 | 3,000 ₹6,000 | 2,950 ₹5,900 Lowest | 5,426 ₹10,852 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
30 Aug 2025, 6:00 pmClosed
Garrison Engineer (MCTE)
GE (MCTE) Mhow (MP) 453441
COMPREHENSIVE DAY TO DAY REPAIR AND MAINT TO INTERNAL ELECTRIC SUPPLY, GEYSERS, FAN REPAIR AND COMPLAINT FOR MAP KODARIYA, INTERNAL ELECTRIFICATION, FITTINGS AND FIXTURE IN CERTAIN OTM ACCN AT AIR FIELD AREA HQ MESS OF MCTE UNDER GE (MCTE) MHOW
2025_MES_723762_1
GE(MCTE)/MHOW/32(T) OF 2025-26
Open Tender
Electrical and Maintenance Works
Works
180 days
GE (MCTE) Mhow
As per Tender Document
10 documents required · 10 mandatory
₹500
Yes
GE (MCTE) Mhow
₹99,000
Yes
9 Oct 2025
31 Jul 2025
1 Sept 2025
31 Jul 2025
30 Aug 2025
16 Aug 2025
Amount
Comprehensive maintenance of ceiling fans/ exhaust fans/ wall fans and connected electric circuit, tightening of loose wiring/ conduits/ fan capacitors and connection carrying out minor repairs incl blade alignments, screwing/ tightening the nuts/ bolts/ washers, cleaning, greasing, fan cap, flexible conduit, incl taking down & refixing properly in the existing position after minor repairs complete all as specified and directed.
Comprehensive day to day maint of the defects pertaining to internal electrification of any type and nature such as taking down defective MCBs / MCB DBs/ TPN/ TPN DBs any type, switch/ socket/ ceiling rose/ holders/ fittings/ fixtures/ building security lights/ Gate light/ Garden light etc. rectification of faulty electric circuits, tightening of loose connections etc. complete all as specified and directed.
Comprehensive maintenance of Geyser of any type or any capacity and nature such as taking down defective geyser any type, removing from existing location, releasing air lock or checking & replacing heating element/ thermoastat/ indicator/ PVC connection/ geyser plug top/ 15 Amps switch & sockets, rectification of faulty electric circuits, tightening of loose connections etc. complete all as specified and directed.
Note for Ser. NO. 1, 2 & 3:- (a) All T&P and labour team required comprising the Nos of trained electricians & helpers will be provided by the contractor daily as directed. (b) Rep of the contractor will present in complaint cell & responsible for receiving & attending the complaints from 08.30 Hrs to 04.30 Hrs at daily the time of lodging the complaint. In absence of rep of Contractor penel recovery will be charged @ 100 Repees to be deducted per complaint not attended within 24 hrs from lodging by any method/ telephonically. (c) Cost of minor stores such as screws, clamps, insulation tapes, nuts/ bolts, nail etc. of required size shall be deemed included in the above quoted item. However, major items such as point wiring any type, switches, sockets, bell push, fan regulator, SPN/ SP/ DBs and geyser parts etc shall be measured and paid separately under appropriate items of Schedule 'A'. (d) Complaints where complete replacement of faulty circuit/ point wiring required, shall be measured under relevent item.
Supply and fix in repair of PCB with sensor for BLDC fan suitable for exisiting BLDC fan PCB as per sample complete all as specified and directed.
M&L for single pole and earth encolsure with a two pin and earth plug with socket 240 Volts, 50 Hz complete with onesingle pole MCB SP 20 Amps including necessary provision for inserting the same in wall by cutting the brick/ stone masonry etc and making good of disturbed surface to match with existing colour of wall complete all as specified and directed.
S&F in repairs metal clad plug and socket (male and female) two pin and with earth, 240 volts, 50 Hz complete all as specified and directed.
Supply and fix LED inverter type bulb of 9 watt, of base B-22 CDL, suitable for fixing in lamp holder including taking down old unsv complete all as specified and directed.
S&F for energy efficient exhaust fan havey duty of 300mm sweep made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12mm dia embedded in the wall including taking down old unsv fand and deposit the same in the MES store complete all as specified and directed.
S&F for energy efficient exhaust fan havey duty of 380/ 450mm sweep as per site requirement made of metal body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12mm dia embedded in the wall including taking down old unsv fand and deposit the same in the AGE E/M-III store complete all as specified and directed.
S&F of ceiling fans complete with blades, down rods 15mm/ 12mm upto two mtr, electronic regulator and remote with battery and complete accessories, 230 V, 50Hz, 1200mm sweep and rated power 26W (+ 10%) and rate speed 350 RPM (+ 10%) Min air delivery 210 CFM with service value shall not be less than 8.00 BEE as per BIS. Five star rated with brushless direct current motor (BLDC), painting to match with existing surfaces including taking down old unsv fand and deposit the same in the MES store complete all as specified and directed.
Supply & fix electric wall fan of 400mm sweep, 230 Volts single phase, white in colour, complete with all accessories like nuts, bolts, clamps etc and connection from ceiling rose including taking down old unsv fand and deposit the same in the MES store complete all as specified and directed.
S & F for Energy saving new generation environmental friendly long life versatile LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including necessary mounting arrangements and provision of 2.5 Sqmm three core copper conductor cable multi stranded from ceiling rose to light fitting and necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts including taking down old u/s street light any type complete all as specified and directed.
S & F in repair of LED PL 18 W Lamp 4 PIN type (LED pin type 18 w lamp) suitable for Existing 2' x 2' ceiling light fittings of 2 x 36/ 3 x 36 wattage type complete all as specified and directed.
Supply and fix in repairs LED tube rod 20 watts, complete with all accessories duly connection with three core flexible copper cable and duly fixed on two Nos PVC square boxes complete all as specified and directed.
Supply and fix in repairs LED tube light fittings 1 x 9/ 10 Watt, 6000K complete fitting with all accessories duly connection with three core flexible copper cable duly fixed on two nos of pvc square boxes complete all as specified and directed.
S&F for energy saving recess/ surface mounted luminaire 36/ 40/ 42W, high efficiency PMMA diffuser gives soft glare free light, suitable for 600 x 600 ceiling cut out, recess mounted 36W LED luminaire in MS housing (2' x 2') incl Provn of three core cable of copper conductor of size 1.5 Sqmm, making necessary electric connetion from ceiling rose to fitting terminal, fixing the fitting on ceiling including cutting, grooving with proper finish and making good, disturbed surface with all fixing arrangement including taking down old u/s light complete all as specified and directed.
Supply & fix LED Bulk Head luminaire 10W, 6000K pressure die cast housing with IP65 protection complete with electric connection & all necessary fixing arrangement including taking down old u/s complete all as specified and directed.
Supply & fix Recessed/ surface mounted LED panel slim, compact, aluminium die castedge lite panel of 15 W, round/ square as per site requirement with premium diffuser to ensure glare free & even distribution of light complete with electric connection including taking down old u/s light complete all as specified and directed.
S & F in repairs for wall mounted LED tube light fitting 20 watts batten for surface mounted, anodized extruded aluminium housing, high transmissitivity diffuser, high lumen ouput box type fitting, 230 volts and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including taking down old u/s tube light complete all as specified and directed.
Supply and fix in repair LED bulb of 12 watt of base B-22, suitable for fixing in lamp holder complete all as specified and directed.
Supply & fix surface mounted round/Square as per site requirement, LED panel of 12W to 16 W with premium diffuser to ensure glare free & even distribution of light complete with electric connection including taking down old u/s light complete all as specified and directed.
Supply and fix in repair of LED 9 watt, BGSBL 9W WW LED Bush light, spun aluminium graphite grey powder coated housing with PDC bottom and die cast aluminium alloy spigot Luminous flux 540 lm, Luminaire efficacy 60lm/W operation temperature range -10 degree C to + 50 degree C, Electrical class-I surge protection 4KV IP 66, IK06 including connection with all necessary fixing accessories complete all as specified and directed.
Supply and fix in repair of Wall light fittings suitable for LED bulb of 7 watt (B-22), polycarbonate/ opel glass as per site requirement including connection with all necessary fixing accessories complete all as specified and directed.
Dismantling of complete defective Ceiling fan of 1200mm sweep (i.e.,) down rod with its Canopies, Shackle, Blade,Condenser housing with its rubber bushes, split pins, unscrewing the body parts of Ceiling fan, taking out starter, rotor winding, ball bearing, gun metal bush etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and rewinding of starter winding with suitable size of Copper enamelled wire, (weight of copper coil shall be same as per dismantled Fan) varnishing heating and testing as per manufactures designed complete all as specified and directed. (b) Re-assembling complete Ceiling fan by fixing only serviceable of old/ new spare parts (i.e.) rubber bush of shackle and condenser housing, condenser, gun metal bushes, blades, ball bearing, twin twisted Copper cable, down rod assembly with its shackle condenser housing and Canopies & split pins complete all as specified and design to give designed air delivery including greasing, oiling, cleaning outer body & surfaces etc all as directed.
All as per Srl Item No.25 above but ceiling fan 1400mm sweep.
All as per Srl Item No.25 here-in-before but exhaust fan of size 230/ 300mm sweep.
All as per Srl Item No.25 here-in-before but exhaust fan of size 380/ 450mm sweep.
All as per Srl Item No.25 here-in-before but pedestal/Cabin fan/ wall fan of size 400 mm sweep.
All as per Srl Item No.25 here-in-before but only overhauling of celing fan 1200mm/ 1400mm by greasing and oiling, replacement of unserviceable/ defective components, except rewinding of starter winding complete all as specified and directed.
All as per Srl Item No.30 here-in-before but exhaust fan of 230 to 450mm sweep.
Note for Ser. No. 25 to 31:- (a) Spare parts found unserviceable/ defective will be measured and paid separately under relevant item as supply only. (b) The element for fixing of new spare parts are deemed to be included in quoted unit rate of above items.
Supply only the spare parts of Ceiling fan 1200mm/ 1400mm sweep of different make:-
(a) Condenser of capacity 2.5 to 3.15 Microfarad, 440 Volts, AC 50 Hz, plastic-casing, two terminal-copper wire, confirming to IS 1709 complete all as specified and directed.
(b) Rubber bush for shackle with bolt, nut and lock pin suitable for Ceiling fan 1200mm/ 1400mm sweep.
(c) Split Pin
(d) Ball bearing of size 6201/ 6202 or as per sample.
(e) Gun metal bush as per sample.
(f) Condenser 4 MFD, 440 Volts, AC 50 Hz as per IS 1709
(g) Condenser housing, suitable for placing condensor at ceiling fan/ Exaust fan as per sample
(h) Fan canopy pvc body, white in colour, suitable for existing fan, as per sample and directed.
M&L for preparation of old painted/ rusted surfaces of 1200/ 1400mm sweep ceiling fan and re-fixing the same after painting of the same with white colour synthetic enamel paint by spraying including filling cavities with filler & one coat after cleaning all dust etc. and writing MES Number in black paint with skilled painter, complete all as specified and directed by Engr-in-Charge. Note :- All T&P and labour team as required will be provided by the contractor and cost deemed to be included in the quoted rate.
Supply and Fixing flush mounting factory made Vertical FP DB, IP-43 Protection -IK 09 with metal double door with 200 Amps rated copper busbar with 2 neutral bar, earth bar and cables ties for cable management fully insulated bus bar with set of wires and door earthing with provision of space for 125 Amps MCCB as incomer and SP/ SPN/ TP MCBs as out going, 4 way (Optium 1+12 Module) including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of distrubed surface to match with existing colour of wall, including taking down old u/s DB complete all as specified and as directed. by Engr-in-Charge.
S & F of TPN DB with provision for MCB TPN as incomer and SP MCBs as outgoing made of steel sheet phosphatised powder coated with bus bar, neutral link earth bar and DIN Rail having IP 42-IK 09 with metal door capacity 4-ways 415 V, connection with aluminium/copper lugs including civil/ plastering work for make up good the disturbed surface matching with existing surface including taking down old u/s DB complete all as specified and directed.
S&F MCCB 4 pole, 415 volts, in the existing panel/ location and connection with using aluminum lugs complete all as specified and directed for 100 to125 Amps rating, 16 KA breaking capacity including taking down old u/s MCCB any type complete all as specified and directed.
Supply and Fix double door SPN DBs 8 ways of powder coated DB's suitable for MCB's fitted with bus bar, Neutral link, Earth bar and Din ral complete all as specified and directed.
Supply and Fix double door SPN DBs 4 ways of powder coated DB's suitable for MCB's fitted with bus bar, Neutral link, Earth bar and Din rail complete complete all as specified and directed.
Supply and Fix double door SPN DBs 12 ways of powder coated DB's suitable for MCB's fitted with bus bar, Neutral link, Earth bar and Din rail complete all as specified and directed.
S & F in repair MCB SPN 32 Amps 10 KA, 'C' series including connection with suitable size aluminium/ copper lugs complete all as specified and directed.
S&F in repair MCB SP 240 volts 5 to 32 Amps, 10 KA breaking capacity, 'B' series including connection with suitable size aluminium/ copper lugs complete all as specified and directed.
S&F in repair MCB triple pole & neutral 63 Amp, 415 volts, 'C' series' 10 KA breaking capacity & connection complete all as specified and directed.
S&F in repair PVC insulated flexible cable three core Copper conductor of size 1.50 Sqmm, ISI marked, covered with white colour round insulation complete all as specified and directed.
S&F in repair PVC insulated flexible cable three core Copper conductor of size 2.5 Sqmm, ISI marked, covered with white colour round insulation complete all as specified and directed.
S & F in repair PVC insulated flexible cable three core Copper conductor of size 4.00 Sqmm, ISI marked, covered with white colour round insulation complete all as specified and directed.
Supply & Fixing in repair PVC twin core cable of size 4 Sqmm complete all as specified and directed.
Supply & Fixing in repair PVC twin core cable of size 2.5 Sqmm complete all as specified and directed.
Supply and fix in repair MS down rod 'medium grade' 15mm dia, in appropriate length of segments of required size of each down rod as per site requirement, including all fixing arrangments like hooks, clamps, nuts, bolts etc for hanging the ceiling fan at site, complete with making split holes, cut or threads at both end of pipe as required for hanging of Ceiling fan incl. painting of down rod with two coats of synthetic enamel white colour paint over one coat of primer complete all as specified and directed.
S & F in repair 'U' shape shackle clamp assembly incl checknut, bolts, screws, washer, lock nut, rubber reel etc and connecting, complete all as specified and directed.
Taking down existing Gysers 25 ltr including Overhauling/ Servicing and replacing of defective/ rusted parts and taking out U/S parts by unscrewing bolts and nuts and change of u/s three pin top, heating element, thermostat, bottom plate and heavy duty PVC connection hot/ cold, etc. Checking defects and re-assembling the Geyser after refixing serviceable/ new parts & cleaning, descaling, complete painting of the geyser with synthetic enamel paint by spray painting machine including filling, insulating with filler, one coat after cleaning all dust, re-installed the geyser in suitable place/ position and connecting inlet-outlet connections & testing complete, refixing the geyser in existing position/ place and writing MES Number in black paint with skilled painter complete all as specified and directed.
All as per Srl item No.59 above, but capacity 50 litres geyser complete all as specified and directed.
Note for Ser No. 59 & 60:- (a) Items required for replacement of U/S parts will be measured and paid separately under relevant item of sch "A". (b) The elements for Labour of new spare parts are deemed to be included in quoted unit rate of above items.
Supply only spare parts of geyser storage type of different make for capacity 25/50 ltrs (Make of spare parts shall be of existing make or as per sample approved by GE)
(a) Apparatus assembly as per sample.
(b) Indication lamp (Green/ Red) as per sample.
(c) Thermostat as per sample.
(d) Heating element 1.5 KW, triangle base type, as per sample and site requirement.
(e) Heating element 1.5 KW, cup, base type as per sample and site requirement.
(f) Geyser inner tank as per sample complete all as specified and directed.
(g) Geyser outer tank as per sample complete all as specified and directed.
(h) Geyser top/ bottom plate as per sample complete all as specified and directed.
(j) Fusible plug suitable for 25/50 ltrs capacity geyser, as per sample complete all as specified and directed.
(k) Angle stop cock, 15mm, as per sample, complete all as specified and directed.
(l) NRV Valve suitable for storage type geyser, 25mm, as per sample, complete all as specified and directed.
(m) NRV Valve suitable for storage type geyser, 12.5mm (0.5"), as per sample, complete all as specified and directed.
S & F in repair PVC connection pipes double layer, heavy duty, ISI Marked, 15mm dia both end socketed, inner threaded 600mm long heavy duty of suitable thickness for hot/cold water as per sample approve by GE.
Supply and Fix Electronic fan regulator, five steps/ hume free, switch type, 230 V, AC, single phase connection complete all as specified and directed.
Supply & fix in repairs modular fan regulator step type, 2 module type complete all as specified and directed.
Taking down submain wiring any type and any size and making good disturbed surface and matching with existing colour complete all as specified and directed.
Taking down switch fuse/ DB'S any type and any capacity complete all as specified and directed.
M&L for concealed point wiring with PVC insulated and unsheathed, single core FRLSH cable of size 1.5 Sqmm stranded copper conductor, 1100 Volt grade, drawn into and including PVC rigid conduit not less than 20mm dia, medium grade, ISI marked with and including 1.5 Sqmm unsheathed green colour stranded copper conductor FRLSH cable for continuous earth wire and including sunken pressed steel concealed terminal boxes of suitable size made out of 1.2mm thick sheet covered with 2.6mm thick white hylum sheet cover of suitable size for mounting switches/ sockets/ fan regulators or Modular flush box for mounting modular switches/ sockets/ regulators etc including cutting chasing in wall and making good disturbed surface with existing colour including taking down old point wiring complete all as specified and directed for the following:-
(a) One light point controlled by two 2-way switches
(b) One light/ fan/ bell point controlled by one switch
(c) One 5 Amps socket out let point controlled by one switch on same board with other switches.
(d) One 5 Amps socket out let point on independent board controlled by one switch.
All as per Srl item No.80 here in before but using pvc insulated unsheathed 2.5 Sqmm cross sectional area cable for phase/ neutral & for earth 2.5 Sqmm green PVC insulated cable for 15 Amps socket point on independent board controlled by one switch.
M&L for Point wiring with PVC insulated FRLSH, PVC unsheathed cable, single core, stranded, copper conductor cable 1.5 Sqmm size, 1100V grade, drawn into with and including PVC casing-capping/ existing not less than 20mm wide, ISI marked, with 1.5 Sqmm unsheathed, stranded copper cable for continuous earth wire and including pressed steel concealed terminal boxes of reqd size made out of 1.2mm thick sheet and covered with 2.8mm thick plastic laminated bakalite (hylam) ISI marked sheet suitable for switches/ sockets/ regulators including taking down old point wiring complete all as specified and directed for the following:-
(a) One light/ fan/ bell point controlled by one switch
(b) One point for socket outlet 5 Amp on independent board
(c) One point for socket outlet 5 Amp SAME BOARD.
All as per Srl Item No.86 above, but with FRLSH cable 2.5 Sqmm stranded copper conductor FRLSH with 2.5 Sqmm copper conductor earth wire for switch/ socket outlet 5 pin, 15 Amps multipurpose on independend board complete all as specified and directed.
S&F modular switch 1 way 6 A, 1 module complete all as specified and directed.
S&F modular switch 2 way 6 A, 1 module complete all as specified and directed.
S&F modular socket 6 Amps 2/3 pin combined 2 module complete all as specified and directed.
S&F switch modular type 16 A, 1 module complete all as specified and directed.
S&F socket modular type multipurposes 6/16 A, 2 module complete all as specified and directed.
Supply & fixing ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body for surface type, 65 x 50mm three terminal complete all as specified and directed.
Supply & fix in repairs modular switch One-way 1-Module, 6 Amps, 230V AC complete all as specified and directed.
All as per Srl item No.97 but 16 Amps complete all as specified and directed.
Supply & fix in repair modular socket 2/3 pin combined 6 Amp, 2 Module, complete all as specified and directed.
Supply & fix in repair modular socket 2/3 pin combined 6/16 Amp, 2 Module, complete all as specified and directed.
Supply & fix in repair modular bell push, flush type 6 Amp,1-Module 220 V, complete all as specified and directed.
Supply and fix in repair switch piano flush type, 5 Amps, 230V AC, single pole, one way complete all as specified and directed.
Supply and fix in repair switch piano flush type 15 Amps, 230V AC single pole one way complete all as specified and directed.
Supply and fix in repair, switch piano flush type 05 Amps, 230V AC single pole Two-way complete all as specified and directed.
Supply and fix in repair socket out let multipurpose suitable for 2/3 pin 5 Amp flush type complete all as specified and directed.
Supply and fix in repair socket out let 2 IN 1, multipurpose suitable for 3 pin 5/15 amp flush type complete all as specified and directed.
Supply and fix in repair Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp, flush type universal as per site requirement complete all as specified and directed.
Supply and fix in repairs, angle type holder insulated body in white colour with back plate complete all as specified and directed.
Supply and fix in repairs ceiling rose, 240V polycorbonate isolated body for surface type, three terminals complete all as specified and directed.
Supply and fix in repairs bell push, flush type 5 Amp, 220 V, single pole complete all as specified and directed.
Supply and fix in repairs, electric bell, ding dong, AC, 220 V, single pole complete all as specified and directed.
Supply in replacement, electric buzzer, AC, 220 V, single pole, complete all as specified and directed.
Supply and fixing in repairs white finished single mounting modular plates suitable for modular accessories of following sizes complete all as specified and directed.
(a) Suitable for 1/2 modules.
(b) Suitable for 3 modules.
(c) Suitable for 4 modules.
(d) Suitable for 6 modules.
(e) Suitable for 8 horizontal modules.
(f) Sutable for 12 horizontal modules.
Supply and fix in repairs sheet metal boxes concealed in wall suitable for housing modular accessories of following sizes complete all as specified and directed.
(a) Suitable for 1 or 2 modules 50mm.
(b) Suitable for 3 modules 50mm.
(c) Suitable for 4 modules 50mm.
(d) Suitable for 6 modules 50mm.
(e) Suitable for 8 modules 50mm.
(f) Suitable for 12 horizontal modules 50mm.
Supply and fix in repair Motor starter switch with overload protection 240 Volts, incl plug, socket, MCB SP 20Amp single pole, suitable & safe for Air conditioners. Coolers, Waters pumps, refrigerators etc, Incl required size of suitable cover plate for fixing starter & sockets and making good of disturbed surfaces with existing colour complete all as specified and directed.
Supply & Fixing and testing of Energy efficient 5 Star BEE rating, electric geyser of 25 liters capacity with Fiber/ ceramic body with puff insulation inner tank ceramic with all in built safety accessories like thermo start/ automatic thermal cut out with ON/OFF/Cut out indications all pre wired and additional safety accessories like pressure release valve, non return valve in same or other position as ordered with the help of suitable suitable size of nuts & bolts making necessary electrical connection incl taking down and safe deposit of old unserviceable Geyser to E/M Store complete all as specified and directed.
S&F in repairs PVC rectangular blocks, for mounting, switch, sockets, fan regulator etc. with 3mm thick plastic laminated sheet cover with closed recessed, designed and cutting module for fixing switches/ sockets of any rating complete all as specified and directed for the following sizes:-
(a) 100mm x 100mm x 50mm deep.
(b) 175mm x 100mm x 50mm deep.
(c) 200mm x 150mm x 50mm deep.
S&F hylum sheet Incl cuttings module suitable for fixing 5/15 Amps switch/ socket/ fan regulator/ indicator etc. of following sizes:-
S&F in replacement 3 pin plug-top, 15A, 240, beckelite, heavy duty suitable for 16 Amp socket outlet complete all as specified and directed.
S&F in replacement 3 pin plug-top, 5A, 240, beckelite, heavy duty suitable for 5 Amp socket outlet complete all as specified and directed.
S&F in replacement LED- Driver suitable for LED ceiling light fittings 34/36 watt (2' x 2') recess mounting type complete with electric connection at both ends (Input (A.C.) and output (D.C.) side), complete all as specified and directed.
S&F in replacement LED- Driver suitable for LED ceiling light fittings 40/ 42 watt (1' x 4') recess mounting type complete with electric connection at both ends, (Input (A.C.) and output (D.C.) side), complete all as specified and directed.
Supply & Fix plastic body exhaust fan AC single phase 230/ 240 V of size 200/ 250mm sweep with louver, white in colour including duly connection with copper wire etc, including taking down and old unserviceable exaust fan deposit to E/M Store complete all as specified and directed.
Supply & Fix plastic body exhaust fan AC single phase 230/ 240 V of size 300mm sweep with louver, white in colour including duly connection with copper wire etc, including taking down and old unserviceable exaust fan deposit to E/M Store complete all as specified and directed.
Supply in repairs Flexible PVC Conduit pipe suitable for cover/ laying electrical wiring etc. complete all as specified and directed.
Supply & Fix in repair of battery for BLDC fan suitable for exsiting remote control as per sample and site requirement complete all as specified and directed.
Supply & Fix in repair, of remote for BLDC fan suitable for exsiting BLDC fan as per sample and site requirement complete all as specified and directed.
Supply and fixing in replacement of exhaust fan motor (PVC body) of any sweep/ make as per site requirement complete all as specified and directed.
Cleaning, dusting and servicing of electric kitchen chimney by authorised agency/ company i.e hindware including replacement of ionised wire connection, spray with CRC complete all as specified and directed. Note:- small damage part like ionised nuts bolts tapping of wire should be including in the quoted rate.
Supply and fixing in replacement of aluminium duct (size 4") for electric kitchen chimney complete all as specified and directed.
Supply and fixing in replacement of cowl cover for electric kitchen chimney complete all as specified and directed.
M&L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sqmm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and directed. Note:- Two runs of 6 Sqmm for P and N and one run of earth and one run of PVC conduit will be measured as one unit
All as per Srl item No.151 here in before but using 4.0 sqmm cable
All as per Srl item No.151 here in before but using 10.0 Sqmm cable
Supply and fix electronic single phase meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH incl taking down old unsv electric meter and deposit to MES store yard complete all as specified and directed.
Supply and fix electronic three phase meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH incl taking down old unsv electric meter and deposit to MES store yard complete all as specified and directed.
Supply and fixing GI pipe light grade 40mm dia in short lengths, to walls/ poles/ pillers including cutting, chasing and fixing one end on walls/ pillers/ in ground for garden light fittings/ gate light complete all as specified and directed.
Sppply & Laying XLPE insulated, armoured, electric cable with aluminium conductor, 1100 volts grade, laid in trenches, fixed on poles/ walls or passing through pipes including provision of necessary lugs and glands & making necessary connection including taking down old unservicable cable of any core complete all as specified and directed, for the following:-
(a) 35 Sqmm 3.5 core
(b) 16 Sqmm 4 core
(c) 10 Sqmm 4 core
(c) 6 Sqmm 2 core
Excavation in trenches not exc. 1.5m wide and not exc 1.5m deep in hard/ dense soil and getting out complete all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed.
Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.50m above the starting point complete all as specified and directed.
M&L for filling approved fine crusted sand in trenches as cable cushion to the full width of excavated trench, under and over cable complete all as specified and directed. (Note : Punned thickness of sand shall be measured)
M&L for bricks slightly over burnt (kiln burnt), modular bricks, best quality, locally available, laid flat, dry, laid in trenches along the length of cable transvarsally with width equal to length of brick for cable protection complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick, buried directly in ground vertically to a depth not less than 2.25 meters deep below ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level connect to galvanised earth lead wire of 4.0 Sqmm size by means of bolts, nuts, check nuts and washers of galvanized iron or steel up to 7.5 meter length including connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover 1:2:4 mix with 6mm dia nominal reinforcement @ 150 mm c/c both ways etc complete all as shown in electrical plate No 5, connected to earthing test point complete including testing incl taking down old unsv earthing complete all as specified and directed.
S&F in repair of Flat Plate collector with toughened glass, collector size not less than 1040 x 2040 x 95mm, section 1.2mm thick aluminium with PP powder coated, absorber plate 0.12mm copper sheet, back sheet 0.46mm thick aluminium, insulation Fibre glass wool with 50mm thick, foil 0.05mm thick aluminium, fins: copper tube 12.7mm ID, 0.56mm thick, Header:-copper 25.4mm ID, 0.7mm thick, flate plate collector with 9 fins for standard collector and 11 fins for 100 to 300LPD, No of riser 9 for better heat transfer performance, flanges : brass, glass beading : EPDM, ultrasonic welded with Nalsun coating, copper 24 SWG, Fasheners : Stainless steel, Reflection foil : 0.5 micron including necessary arrangement of screw, nut bolts and required accessories to fixing and connecting in existing frame of flate plate collector, complete all as specified and directed as per existing make
Taking up or down of old galvanised steel water tubing medium grade laid in walls, floors or ceilings etc including all fitting cleaning of serviceable pipe and segregating for re-use and removing unserviceable pipes from site of work complete all as specified and directed.
(a) 40mm bore GI pipe complete all as specified and directed.
(b) 25mm bore GI pipe complete all as specified and directed.
(c) 20mm bore GI pipe complete all as specified and directed.
(d) 15mm bore GI pipe complete all as specified and directed.
Relaying of serviceable GI pipe in walls. Floors, ceilings including old fitting as obtained from item No.169 here-in-before after thorough cleaning of pipe (both sides) complete all as specified and directed.
(a) 40mm bore GI pipe complete all as specified and directed.
(b) 25mm bore GI pipe complete all as specified and directed.
(c) 20mm bore GI pipe complete all as specified and directed.
(d) 15mm bore GI pipe complete all as specified and directed.
Supply and laying galvanised steel water tubing medium grade as per IS-1239 (Part-1) with all new fittings in walls, floors,ceilings in new or old alignment complete all as specified and as directed.
(a) 40mm bore GI pipe complete all as specified and directed.
(b) 25mm bore GI pipe complete all as specified and directed.
(c) 20mm bore GI pipe complete all as specified and directed.
(d) 15mm bore GI pipe complete all as specified and directed.
M&L for filling Distilled water in Solar water Heating systems complete all as specified and directed at site. Note:- Distilled water will be supplied in sealed containers.
Supply and fixing thermostat suitable for solar water heater heating element 3KW complete all as specified and directed.
Supply and fixing in repairs Gun-metal, globe or gate valves, 25mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fixing in repairs Gun-metal, globe or gate valves, 40mm dia with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair of 15mm Ball brass valves high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
M&L for replacing broken PCC pedestrials of Angle Iron frame of solar water heaters with necessary form work, finishing with cement concrete 1:2:4 type B1 as per standard use and making good and cleaning the surfaces including demolation of old PCC complete all as specified and directed.
M&L for in repair of Angle Iron support by removing the old/rusted Angle iron frame work by proper dismantlig of the entire system, removing all electrical connections, welding, grinding complete all as specified and directed.
M&L for painting of Angle Iron support of solar water heating system of 100 to 300 LPD capacity by removing old/ rusted painting with sand paper, providing two coat of red oxide primer after surface preparation, and painting with metallic paint of approved colour complete all as specified and directed.
M&L for nitrile rubber insulation of suitable size for 20 to 25mm G.I hot water pipe per meter as per sample & as directed. Note:- The Insulation thickness not less than 10mm complete all as specified and directed by Engr-in-Charge.
M&L for nitrile rubber insulation of suitable size for 40mm G.I hot water pipe per meter as per sample & as directed. Note:- The Insulation thickness not less than 10mm complete all as specified and directed by Engr-in-Charge.
SAHYOG ELECTRIC (BID ID -3403570)
MODI CORPORATION (BID ID -3403127)
Vinayak Trading House (BID ID -3410893)
Swasti Electricals (BID ID -3400852)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .