| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.3 LAccepted-AOC D 35 1ST FLOOR CLOCK TOWER HARI NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | 1 | Accepted-AOC LOWEST RATE | |
| 2 | 2₹23.3 L+₹1.9 L (9.07%)Rejected-Finance | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹24.7 L+₹3.4 L (15.9%)Rejected-Finance | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹25.2 L+₹3.8 L (17.9%)Rejected-Finance | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹26.0 L+₹4.6 L (21.8%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | 5 | Rejected-Finance NOT LOWEST |
Tender Value
₹32.5 L
EMD Value
₹64,900
Closing Date
13 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF PALAM DELHI CANTT
GE AF PALAM DELHI CANT110010
ADDITION / ALTERATION TO STN ARMOURY AND CERTAIN MINOR WORKS AT AF STN PALAM DELHI CANTT-10
2022_MES_563259_1
GENP-52/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE AF PALAM DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE AF PALAM
₹64,900
Yes
24 Apr 2023
15 Nov 2022
14 Dec 2022
15 Nov 2022
13 Dec 2022
30 Nov 2022
Amount
B/R PORTION Dismantling of brick tiles single layer on roof laid dry or with cement mortar including removing the debris from site to outside MoD land complete.
Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) including removing the debris from site to outside MoD land complete.
Taking down of existing tarfelt and cement plaster of any description and thickness on roof top including flashing and junction of parapet and cleaning existing roof top surface by brooming , wire brushing including removing the debris from site to outside MoD land complete.
M&L for 15 mm thick screed bedding layer on concrete surface on roof in cement plaster 1:4 including finishing even and smooth surface without using extra cement by using water proofing compound of weight of cement content as per manufacturer instruction. (Note: Water proofing compound shall be measured and paid seprately)
M&L for cement concrete type B-0, 1:2:4 ( using 12.5mm graded crushed stone aggregate ) as in roof padding complete all as specified.
Supply only water proofing compound as per manufacturer instruction. Make : Dr Fixit or its equivalent.
M&L for APP based modified pre fabricated five layer 3 mm thick and weighing not less than 3.6 Kg/Sqm water proofing membrane reinforced with polyester non woven fabric mat with 150 gm/Sqm black finished with compatible primer conforming to IS 3488 @ 0.30 Litre / Sqm before laying membrane laid by torch application method with side overlap of 75 mm and over lap of 100 mm longtitudinally. At the junction of roof and parapet wall a grove of 20mm x 20mm shall be made at the height of 100 mm and membrane shall be inserted and sealed with bituminious mastic joints/overlap duly sealed with hot bitumen 85/25 all as specified and directed by Engineer-in-charge
M&L for providing cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in coping to parapet wall,kerbs etc on roof with projection of 50mm from the outer surface with a groove of 12 mm x 12mm as drip course in bottom side including necessary form work complete all as specified and as directed by Engineeer-in- Charge.
Taking up or down 15mm bore steel tubing and connections fixed in walls, ceilins, floors etc all as specified and directed by Engineer-in-Charge.
M&L for 15mm bore GI tubing medium grade with all fittings and fixed to walls and ceilings or laid in floors and cutting holes n exc 100 Sqcm superficial area, chase,pinning in making good to facings where required in cement mortar 1:3 for concealed water tubing complete all as specified .
Taking down cement plaster on brick or concrete surface etc including raking out joints, hacking for key , scrubbing down with water etc complete.
M&L for 10 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces including finishing even and smooth surface without using extra cement.
M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces in cement mortar 1:4 including finishing even and fair surface without using extra cement with water proofing compound by weight as per manufacturer's instructions.
M&L for 5 mm thick cement plater in cement mortar 1:3 as in ceiling including finishing even and smooth surface without using extra cement
M& for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer using roller including necessary scaffolding complete all as specified and directed.
M&L for preparation of newly plastered surfaces in ceiling and applying two coats oil bound distemper over a coat of primer using roller including necessary scaffolding complete all as specified and directed.
M& for preparation of newly plastered surfaces of external walls and applying two coats of exterior emulsion paint (Make Apex of Asian or equivalent in Shalimar/Berger paints) over one coat of primer after applying 3mm thick wall care putty to obtain smooth finish surface etc complete all as specified and directed by Engineer - in- Charge.
Taking down rain water pipes (any size or pattern) including all fitting as heads, shoes, bends,swan -necks etc
S&F for PVC(SWR) bends any radius 110 mm bore.
S&F for 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including suitable clamps after every one meter of interval complete all as specified.
S&F in repair Gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe 20 mm bore complete.
Dismantling of floor hearth or wall tilling including cement mortar bedding (but not backing) including removing the debris from site to outside MoD land complete.
M &L for ceramic coloured/ printed non-skid tile of size 7 to 8 mm thick( square / rectangular ) area of each tile exceeding 0.06 Sqm but n. exec. 0.11 Sqm laid as in floors, set and jointed with neat cement slurry and pointed in white cement with pigment to match the colour of tiles over & including 15 mm thick screed bedding layer of cement sand mortar ( 1:4) .
M&L for glazed ceramic coloured tiles (colour & shade as approved by GE) of size 300x200x7mm thick on vertical surfaces as in skirting,dado etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour of tiles over 10mm thick rendering in cement mortar (1:4).
Demolition of cement concrete of any description and in any position not otherwise specifically provided including removing the debris from site to outside MoD land complete.
Dismantling wall and ceiling boards ( fibre , pulp,insulation etc.) or insulation boards / slabs / blankets , any thickness including fillets all as specified
S&F for 12mm thick Lafarge Gypsum board suspended Ceiling system (India gypsum make or its equivalents ) with ISI grade GI framing of intermediate channel 15mmX45mmX15mmX0.9mm, perimeter channel and ceiling angle 25mmX10mm section with connecting clip 2.64mm dia including all hardware i.e soffit cleat,rawl plug,edge bead,angle bead,nut &bolt drywall screws, hangers etc with all hanging accessories, cut out to made for lighting, fixture and AC grills etc complete all as specified and directed by GE..
M&L for complete removal of existing treatment of old decorated external surface of walls by electrically operated grinder including necessary scaffolding etc and applying two coats of exterior emulsion paint (Make Apex of Asian or equivalent in Shalimar/Berger paints) over one coat of primer after applying 3mm thick wall care putty to obtain smooth finish surface etc complete all as specified and directed by Engineer- in- Charge.
M&L for preparation of plastered or unplastered old decorated surface of walls by brooming down with steel wire brushing, scraping down, smoke soot's moulds, moss efflorescent salts& trading oil, greasy spots and filling cracks/holes with wall care putty and applying one coat of oil bound distemper all as specified and directed by engr-in -charge
M&L for prepartion of plastered or unplastered old deorated surfaces of ceiling by brooming down with steel wire brushing, scraping down smoke, soot, mould, moss efforescent, salt & trading oil and grease spots and filling cracks/holes with wall care putty and applying two coats of oil bound distemper all as specified and directed by Engr- in- charge,
M&L for preparation of old painted wood & wood based surface of any description not otherwise described over 10 cm width & girth and applying two coats of synthetic enamel paint .
Material and labour for preparation of old painted steel and iron surfaces of any description not otherwise described over 10 cm width & girth and applying one coat of synthetic enamel paint.
S&F for rolled mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming with Fe-290 grade E-165.
S&F for 1.60mm thick mild steel plain sheet (black ) as in wall cladding, steel gates and similar work, cut to size ,hole punched, including round headed screw,clout nails or rivet and fixing to wood or steel framing with plain 40mm lap joints with riveted or seams including bending or turning up mitred angles etc.
Taking down shutter of any description area exc 1sqm and n.exc 2 Sqm each.
S&F for 35mm thick second class hardwood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed .
S&F butt hinges cold rolled mild steel 100mm long medium weight
S&F extruded anodised aluminum alloy handle 125mm long fabricated type .
S&F anodised aluminum barrel tower bolt of extruded section 150mm long.
S&F aluminum alloy sliding door bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheet and fixing bolts of extruded section all as specified.
S&F floor door stopper of size 140 mm long aluminium body and tongue, anodized with hard drawn steel spring including cleats etc fixed to door.
M&L for two coats of synthetic enamel paint over a coat of primer after preparation of newly wooden surface exc 10cm width or girth of any description complete all as specified .
M&L for two coats of synthetic enamel paint over a coat of red oxide primer after preparation of newly steel surface exc 10cm width or girth of any description complete all as specified .
S&F in repairs stainless steel wire cloth 0.36mm nominal dia of wire and and average width of aperture not more than 1.40mm fixed with stainless steel wire staples.
S&F Vitreous Cliina wash basin, white, flat back, size 550x400mm including PVC waste pipe of adequate length,brackets,CP waste fitting,cutting for and pinning in ends of brackets or erecting stand complete.
S&F 15mm dia Pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed.
S&F 15mm dia Bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed.
S&F PVC connection 15 mm dia with PTMT nuts and 450mm long.
S&F 15mm dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed.
S&F PVC(SWR) floor tap with grating including jointing with solvent for 75mm bore pipe.
S&F PVC(SWR) bend110 mm dia of any radius with oval acess door
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors.
Demolition of brick work or stone masonry built in cement mortar including all quoins, pillars, arches etc complete all as specified.
S&F in repairs EWC, white, including P or S-trap, PVC seat cover white (Standard) with hinging devices, PVC bend etc Cat Part No 20044 of Hindware or its equivalent in CERA/PARRYWARE as approved by GE complete.
S&F 10 ltrs capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, long bend pipe for IWC/EWC complete.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exceeding 6mtr mean radius, built in cement mortar 1:6.
M&L for cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l superficial area exc150 Sqcm but n.exc. 400 Sqcm all as specified and directed by Engr-in-Charge.
M&L for framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting etc conforming to Fe-290 Gde-E-165 for cooler stand complete.
Excavation in post holes (or similar holes) not exc 0.50 Cum each in soft/loose Soil and getting out, returning filling in and removing surplus spoil to a distance not exc 50mtr.
M&L for mild steel works for hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc, wind ties for roof including securing bolts, posts, struts including cutting tops to shape as directed, drilling holes, notching for wire etc,flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165.
M&L for mild steel rolled sections as in main and cross beams, rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates etc conforming to Fe-410W(GdeE-250) quality-A including all necessary welding, bending,drilling holes for bolts complete all as specified and as directed.
M&L for cement concrete 1:3:6,type C-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete, posts etc complete all as specified and as directed.
M&L for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering,cladding etc fixed with self tapping including dismantling of existing sheet in any position all as specified and directed by Engr-in-Charge.
S&F aluminum anodised coloured powder coated door frame and shutters with single or double leaf, glazed prelaminated particle board in interior panels including aluminium powder coated rubber gas kit and packing materials and drilling in existing wall and thrust bolt of suitable size complete with the followings :- (a) Door frame section of size 101.60mm x 44.45mmx1.93mm thick. (b) Door shutter Vertical style of size 85mmx44.45mmx2mm thick. (c) Door shutter top rail section 95.25mmx44.45mmx2mm thick. (d) Aluminium coloured powder coated middle lock rail/bottom rail section 150mmx44.45mmx1.93mm. (e) Aluminium coloured powder coated Tower bolts 02 Nos in each shutter 200 long as spd. (f) Aluminium coloured powder coated handle 150mm size- 02 Nos in each shutter . (g) Door floor spring ISI marked. (h) Six lever mortice lock brass in each door. (j) 12mm thick partical board (prelaminated both side ) exterior grade ISI Marked. (k) Tinted glass/plain glass (Colour) 5mm thick.
E/M PORTION Taking down carefully unserviceable copper/aluminium point wiring (light, fan, socket or power)complete including fixture and fitting such as switches,ceiling rose, lamp holder, regulators, sockets, wooden terminal boxes, plastic laminated sheet cover etc all as specified and directed by Engr-in-Charge.
S&F for point wiring with PVC insulated 1.5 Sqmm FRLSH multistrand copper conductor cable 1100 volts grade drawn into and including stove ennamelled steel conduit heavy grade not less than 20 mm dia ISI marked with all conduit fittings and fixing accessories for mounting flame proof switches, sockets etc and 1.5 Sqmm FRLSH multistrand copper conductor cable as continuous earth wire connecting to common earth dolly complete for light/ fan point all as specified and as directed by Engr-in-Charge.
All as per item No.66 here-in-before but for one 3 pin 5 Amps socket out let point on the same board controlled by one switch .
All as per item No.66 here-in-before but for 3 pin 5 Amps socket out let on independent board and different wall controlled by one switch.
All as per item No.66 here-in-before but for one power point 6 pin 15 Amps socket out let with 2.5 Sq mm stranded copper conductor cable PVC insulated including earth wire 2.5 Sq mm copper conductor cable connected to earth dolly complete.
S&F in replacement of LED light fitting 2x16Watt flame proof, CMRI certified recommended for gas/ vapor group of group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size all as specified and directed.
S&F switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete.
S&F exhaust fan 300mm size, flame proof ,single phase 240 volt ,50 HZ complete Cat part No. EF/140 of SUDHIR or its equivalent.
S&F sheet metal enclosure for distribution board SPN (when MCBs to be used ) 8 way double door, 200 Amps rated bus bars and with neutral, earthing bar and din rail complete all as specified and as directed.
S&F in replacement of MCB,SPN, 40 Amp ,240V, 10KA 'C' curve complete with connection testing and commissioning complete.
S&F in replacement of MCB,SP, 6-32 Amp ,240V, 10KA 'C' curve complete with connection testing and commissioning complete.
M&L for making of opening in brick masonary wall for fixing of 300mm sweep exhaust fan including making good surface complete.
S&F switch piano flush type 5 Amps, single pole one way .
S&F socket out let 3 pin 5 Amps, flush type .
S&F for switch piano flush type single pole one way 15 Amps.
S&F for socket outlet 2 in 1, 6 pin 5/15 Amps, flush type .
S&F in replacement of Indoor decorative LED battens- integrated type 20 watt 4 feet white fixture with extruded aluminium body, suitable for LED tube 20 watt , bipin holder, connector block, LED rod 20 watt etc complete with all accessories internally are wired and including connecting up with twin core copper conductor cable complete.
S&F Air circulator fan 230 Volts single phase oscilating 450mm sweep suitable for wall mounted complete all as specified and directed by Engr-in-Charge.
S&F for single pole netural enclosure with two pin and earth plug and socket complted with one single pole MCB single pole 20 Amps all as specified and as directed.
Taking down unservesiable sub main wiring with conduits/battens etc complete all as specified and as directed.
S&F for submain wiring with two single core 4.0 sqmm PVC insulated FRLSH multistrand copper conductor cable drawing into and including stove ennamelled steel conduit heavy grade not less than 20 mm dia ISI marked with all conduit fittings & fixing accessories and one single core 4.00 Sqmm multistranded copper conductor cable as continuous earth wire complete concealed wiring system including making good the disturbed surface of wall all as specified and directed by Engr-In-Charge.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, PCC concrete chamber of size 300 mm x 300 mm x 300 mm ( inside dimension) in 1:3:6 type C-1 mix (using 20mm graded crushed stone aggregate),15mm thick cement plaster in CM 1:4, funnel with wire gauge of 22 gauge 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm in 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with XPM, JALLI and charcoal dust and common salt all as shown in Electrical plate No. 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete including all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge.
Taking down carefuly existing GI /Copper strips of any description from roof and wall etc of any height all as specified and directed by Engr-in-Charge.
Taking down carefuly existing aluminium strips of any description from hanger, roof wall etc of any height all as specified and directed by Engr-in-Charge.
Taking serviceable air termination rod aluminium of any shape or size from hanger, roof wall etc of any height and re-fixing the same complete on roof all as specified and directed by Engr-in-Charge.
M&L for copper strip 20mm x 3mm for earth continuity conductor including fixing on porcelain holder insulator for support on wall / roof etc with suitable size screw, nut bolts etc complete.
M&L for 32mmx6mm galvanised iron strip including fixing on porcelain holder insulator for support on wall / roof etc with suitable size screw ,nut bolts etc complete.
M&L for 25mmx3 mm aluminium strips with and including porcelain holder insulator for support on wall / roof /hangar roof and walls at any height with suitable size screw, nut bolts etc complete.
Fixing only aluminium strips 25 x 3 mm with and including on porcelain holder insulator for support on wall roof top any hight etc with suitable size screw, nut bolts etc complete .
M&L in replacement of test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8 mm dia 25mm long hex head screw complete.
Supply & Laying LT XLPE insulated screened PVC bedded electric power cable (Heavy duty) 1100 volts grade galvanised steel strip armoured with stranded aluminium conductor 35 Sqmm 3.5 core laid in trenches/ ducts, fixed to wall/pole/inside panel drown through pipe etc including testing all as specified and as directed by Engr-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.50 mtrs wide and not exc. 1.5 Mtr deep and getting out for laying of cables, poles & stay etc.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid in trenches and testing complete.
Removal of excavated surplus soil to a distance not exc. 50 mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point .
M&L for sand cushioning to under ground cable in layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm) and below 2 pole/ 4 pole structures and filling of ducts etc all as spsecified and directed by Engr-in-charge. Note:- For the purpose of measurement only punned thickness will be mearsured )
M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat complete.
S&F for Vertical type load line distribution board, double door, 4 way, AC ,3 Phase, 415 volts ,TPN, bus bar 200 Amps rating and earth bus & din rail suitable for MCCB as incomer complete all as specified and as directed by Engr-in-Charge.
S&F MCCB, 3 pole,100A ,16KA., 415 Volts.
S&F MCB SP 6-32A, 10KA, 230 Volts 50 Hz 'B' series.
Kunal Construction Co.
JAIPAL AND BROTHERS
Mahesh Enterprises
Commercial Traders
M/S Parshant Associates
SHEELSONS ENTERPRISES
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .