| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.7 LAccepted-AOC SHOP NO 106 1ST FLOOR ASHOKA SHOPPING CENTRE LT ROAD MUMBAI 400001 | MUMBAI | MUMBAI | MAHARASHTRA | 400001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹36.5 L+₹32,054.72 (0.89%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹37.5 L+₹1.4 L (3.83%)Rejected-AOC FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹39.6 L+₹3.4 L (9.46%)Rejected-AOC MAYURESH BHARAT CHS PLOT NO 170 181 B 09 SECTOR 21 NERUL NAVI MUMBAI 400706 | THANE | MAHARASHTRA | 400706 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹43.0 L+₹6.9 L (19.1%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
19 Jan 2021, 6:00 pmClosed
CWE KARANJA
CWE KARANJA NAVAL STATION KARANJA URAN RAIGAD-400704
PERIODICAL MAINTENANCE AND ESSENTIAL REPAIRS OF FIRE ALARM SYSTEM INSTALLED AT NAVAL STATION KARANJA
2020_MES_399624_2
84063-K/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
NAVAL STATION KARANJA
Please refer tender documents
11 documents required · 11 mandatory
₹500
Yes
CWE KARANJA
₹80,000
Yes
2 Feb 2021
31 Dec 2020
21 Jan 2021
31 Dec 2020
19 Jan 2021
7 Jan 2021
Amount
Sch ''A'' Part-I (PERIODICAL MAINTENANCE)
Material and labour for periodical maintenance of fire alarm system by attending fault, testing of system, periodical checking of system, including testing on monthly basis in presence of user representative etc., including attending system fault on emergency, preventive measures by replacing minor spares (up to cost Rs 500/-) other than mentioned in Schdule 'A' part II for fire alarm system installed at Magic Matra bldg comprising following complete all as specified and as directed by Engg-in-Charge. (a) 06 Zone main control panel with zone card battery charger and 230 V power unit. (b) Ionisation type smoke detector, heat detector, response indicator, manual call point and hooters etc., (c) All cable connections from main control panel to item. (d) Lead acid battery any capacity. (e) Electric Hooter.
All as per srl item No. 1.01 here-in-before but for compressor room bldg in EKM complex (Bldg No 784) but for 8 Zone main control panel.
All as per srl item No. 1.01 here-in-before but for oxygen workshop bldg in EKM complex (Bldg No 783) but for 8 Zone main control panel.
All as per srl item No. 1.01 here-in-before but for Armoury store room at INS Abhimanyu complex but for 2 Zone main control panel.
All as per srl item No. 1.01 here-in-before but for Sea Cat workshop bldg in NAD (karanja) with 3 zone main control panel.
All as per srl item No. 1.01 here-in-before but for Maurya Hanger but for 15 Zone main control panel.
All as per srl item No. 1.01 here-in-before but for Harshawardhan Hanger but for 15 Zone main control panel.
All as per srl item No. 1.01 here-in-before but for Akbar 1 Hanger but for 2 Zone main control panel.
All as per srl item No. 1.01 here-in-before but for Club TP but for 5 Zone main control panel.
All as per srl item No. 1.01 here-in-before but for NAD Explosive area Fire Station but for 10 Zone main control panel.
All as per srl item No. 1.01 here-in-before but for INS Tunir Hanger but for 10 Zone main control panel with electric siren of 02 Km range and amplifier and microphone.
All as per srl item No. 1.01 here-in-before but for 582 Bldg but for 07 Zone main control panel with electric siren of 02 Km range and amplifier and microphone.
All as per srl item No. 1.01 here-in-before but for Chukar Squadron but for 04 Zone main control panel.
All as per srl item No. 1.01 here-in-before but for Kakoli Bldg but for 12 Zone main control panel.
All as per srl item No. 1.01 here-in-before but for Kalapi Bldg but for 24 Zone main control panel.
All as per srl item No. 1.01 here-in-before but for Kiran Bldg but for 24 Zone main control panel.
All as per srl item No. 1.01 here-in-before but for Komal Bldg but for 24 Zone main control panel.
All as per srl item No. 1.01 here-in-before but for Kailash Bldg but for 24 Zone main control panel.
All as per srl item No. 1.01 here-in-before but for Kesar Bldg but for 12 Zone main control panel.
All as per srl item No. 1.01 here-in-before but for Koyal building but comprising following: (i) Manual operated 8 zone electronic control panel (ii) Electric hooter (iii) Manual Call point (iv) Lead Acid battery etc.,
All as per srl item No. 20 here-in-before but Kalpana building.
All as per srl item No. 20 here-in-before but Kaneri building. Note for Sl item Nos 1.01 to 22: (i) Cost of Minor spare parts replaced other than listed in Sch"A" Part II shall be deemed to be included in the rate quoted by the contractor.
Sch ''A'' Part-II (ESSENTIAL REPAIRS)
Excavation in trenches not exc 1.5m wide and not exc 1.5m depth and getting out in soft /loose soil including taking out faulty cable /cable, cable covers and GI pipe complete all as specified and as directed by Engr-in-charge.
Returning filling in including spreading leveling watering and well ramming in layers not exc 25 cms thick complete all as specified and as directed by Engr-in-charge.
Removing excavated soil not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and as directed by Engr-in-charge.
Material and labour for sand cushioning with dry river sand in trenches for cushioning of underground cable line including spreading, leveling, well ramming complete all as specified and as directed by Engr-in-charge.
Supply and laying un-reinforced precast concrete cable cover with embossing of cable size and capacity class LV type 1, flat size 250x150x40mm complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement manual call point red coloured surface mounting type of standard size with alarm raising push button, plastic coated glass element in and out terminal metal hammer with chain etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement manual call point outdoor type, weather proof, ISI marked, red coloured surface mounting type of standard size with alarm raising push button, plastic coated glass element in and out terminal metal hammer with chain etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement outer cover for manual call point for protection from rain made out of MS sheet, painted in red colour, standard type, factory fabricated complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement smoke detector confirming to E- 54.7 standard of size 100mm dia, height 56mm suitable to work on 24V DC (12 V DC - 28 V DC) fixed with LED made out of frame retardant plastic confirming to fire protection standard complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement heat detector automatic reset type (class air series 65) complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement 1.5 sqmm 2 core armoured copper conductor cable ISI marked complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement 1.5 sqmm 4 core armoured copper conductor cable ISI marked complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement 1.5 sqmm 16 core armoured copper conductor cable ISI marked complete all as specified and as directed by Engr-in-charge.
Supply and fix lead acid battery 12V/ 25AH capacity (maintenance free) complete all as specified and as directed by Engr-in-charge.
Supply and fix lead acid battery 12V /42AH capacity (maintenance free) complete all as specified and as directed by Engr-in-charge.
Supply only lead acid battery 12V/ 7AH capacity (maintenance free) complete all as specified and as directed by Engr-in-charge.
Supply and fix in repair fire alarm hooter with speaker suitable for PA system complete all as specified and as directed by Engr-in-charge.
Supply and fix fire alarm sounders /sirens electronic type horizontal single stage continues normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5m with sound output variation of +5 DB of 3500m range complete all as specified and as directed by Engr-in-charge.
Taking down unserviceable conventional type fire alarm control panel from existing position and supply, testing and install new conventional type fire alarm control panel of 8 zone to work on single phase AC supply 50 HZ fabricated out of CRCA sheet steel 1.6mm thick duly painted with CRCA sheet steel over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint first quality of approved colour for panel board including wiring with suitable copper conductor cable from panel to floor level manual call point and upto smoke/ heat detector if required complete all as specified and as directed by Engr-in-charge.
Taking down unserviceable conventional type fire alarm control panel from existing position and supply, testing and install new conventional type fire alarm control panel of 12 zone to work on single phase AC supply 50 HZ fabricated out of CRCA sheet steel 1.6mm thick duly painted with CRCA sheet steel over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint first quality of approved colour for panel board including wiring with suitable copper conductor cable from panel to floor level manual call point and upto smoke/ heat detector if required complete all as specified and as directed by Engr-in-charge.
Taking down carefully conventional type fire alarm control panel 12 Zone from existing position (NAD Fire Station) and supply, testing and install new conventional type fire alarm control panel of 28 Zone including Zone card, Contral module, suitable size relay to work on single phase AC supply 50 HZ fabricated out of CRCA sheet steel 1.6mm thick duly painted with CRCA sheet steel over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint first quality of approved colour for panel board including wiring with suitable copper conductor cable from panel to floor level manual call point and upto smoke/ heat detector if required complete all as specified and as directed by Engr-in-charge.
Supply, installation, commissioning and testing conventional type fire alarm control panel 12 Zone at Map Sailor bulding obtained against item ser No.44 here-in-before complete all as specified and as directed by Engr-in-charge.
Taking down unserviceable conventional type fire alarm control panel from existing position and supply, testing and install new conventional type fire alarm control panel of 32 Zone to work on single phase 50 HZ fabricated out of CRCA sheet steel 1.6mm thick duly painted with CRCA sheet steel over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint first quality of approved colour for panel board including wiring with suitable copper conductor cable from panel to floor level manual call point and upto smoke/ heat detector if required complete all as specified and as directed by Engr-in-charge.
Taking down unserviceable conventional type fire alarm control panel from existing position and supply, testing and install new conventional type fire alarm control panel of 32 Zone repeater type to work on single phase 50 HZ fabricated out of CRCA sheet steel 1.6mm thick duly painted with CRCA sheet steel over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint first quality of approved colour for panel board including wiring with suitable copper conductor cable from panel to floor level manual call point and upto smoke/ heat detector if required complete all as specified and as directed by Engr-in-charge.
BRITE INDUSTRIES
M.K Enterprises
ECOBUILD
M/S GLOBAL FIRE PROTECTION SYSTEM
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .