| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L 1₹23.3 LAccepted-AOC | L 1 | Accepted-AOC AOC done | |
| 2 | L 2₹26.7 L+₹3.3 L (14.3%)Rejected-Finance | L 2 | Rejected-Finance L2 | |
| 3 | L 3₹31.5 L+₹8.1 L (34.7%)Rejected-Finance VILLAGE DINAK P O KANAID TEHSIL SUNDERNAGAR | BILASPUR | HIMACHAL PRADESH | 174001 | L 3 | Rejected-Finance L3 | |
| 4 | L4₹38.9 L+₹15.5 L (66.6%)Rejected-Finance H NO 199 W NO 6 NEAR OLD SDM OFFICE DISTT HAMIRPUR HP 177001 | HAMIRPUR | HAMIRPUR | HP | 177001 | L4 | Rejected-Finance L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Non Responsive |
Tender Value
₹24.6 L
EMD Value
₹49,300
Closing Date
29 Oct 2021, 5:00 pmClosed
EE Elect division HPPWD Una
EE Elect division HPPWD Una
Providing E.I. therein
2021_PWD_53065_1
School building at G.S.S.S.(Boys) Una
Open Tender
Electrical Works
Item Rate
365 days
Una
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
₹49,300
1 Jun 2022
22 Oct 2021
30 Oct 2021
22 Oct 2021
29 Oct 2021
22 Oct 2021
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.Make :-Legrand (Myrius)/L&T (Oris) / Anchor ( Roma plus)
Group C.
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.Make :-Legrand (Myrius)/L&T (Oris) / Anchor ( Roma plus)
Group C.
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(SSK/KEI/Anchor/L&T make)
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(SSK/KEI/Anchor/L&T make)
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(SSK/KEI/Anchor/L&T make)
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.(SSK/KEI/Anchor/L&T make)
2x1.5 Sq. mm.
2x6.0 Sq. mm.
2x10 Sq. mm.
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(SSK/KEI/Anchor/L&T make)
Wiring for circuit / sub-main with 3x25+1x16 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.16 Sq.mm. (3x25+3x16) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.(SSK/KEI/Anchor/L&T make)
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.(SSK/KEI/Anchor/L&T make)
3x1.5 Sq. mm.
6x1.5 Sq. mm.
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.Make :-Legrand (Myrius)/L&T (Oris) / Anchor ( Roma plus)
S.P. 5/ 6 Amps one way Modular switch.
5 pin, 5/ 6 Amps Modular socket outlet.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.Make :-Legrand (Myrius)/L&T (Oris) / Anchor ( Roma plus)
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.Make :-Legrand (Myrius)/L&T (Oris) / Anchor ( Roma plus)
Supplying and fixing bakelite batten/angle holder including connections etc. as required:- (SSK/Anchor make)
Supplying and fixing call bell / buzzer, suitable for D.C./A.C. single phase,230 volts complete as required:- (SSK/Anchor make)
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-(SSK/Anchor make)
Supplying and erection of wall mounted metal boards for switch gear mounting of suitable size, with permissible variation in size of plus minus 5mm, welded frame work made of M.S. angle iron 35 mm x 35 mm x 6 mm thick duly welded complete with 2.80mm thick M.S. sheet fixed with hinges as open able front, complete with locking arrangement including painting and bonding to the existing earth as required:-
Supplying and fixing sheet metal bus-bar chamber suitable for 63 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 300mm & cross-sectional area (16mmx3.17mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (380mmx350mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-(Legrand/Schneider/Siemens make)
Supplying and fixing sheet metal bus-bar chamber suitable for 200 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 300mm & cross-sectional area (25.4mmx4.75mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (380mmx450mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:--(Legrand/Schneider/Siemens make)
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required.(Legrand/L&T/ABB/Siemens make)
160 Amp. -16 KA
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- (Legrand/Hagger/ABB/L&T make)
Single pole. 6 Amps.Cat-A.
Single pole. 16 Amps.Cat-A.
Single pole. 25 Amps.Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-(Legrand/Hagger/ABB/L&T make)
Double pole. 40 Amps.Cat-A.
Double pole. 63 Amps.Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Legrand/Hagger/ABB/L&T make)
40 Amps. Cat-A.
63 Amps. Cat-A.
Supplying and fixing 20 Amps, 240 volts, SPN industrial socket outlet, 2-pole & earth, metal enclosed plug top, sheet steel enclosure, suitable to accommodate a 20 Amp SPN-MCB/DP, on surface or in recess, with chained metal cover for the socket outlet, complete with connections, testing and commissioning etc. as required. (Legrand/Hagger/ABB/L&T make)
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- (Legrand/Hagger/ABB/L&T make)
Single door-12 way
Single door-16 way
Double door-12 way
Double door-16 way
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Providing and fixing 25mm x 5mm copper strip on surface or in recess for earth connections etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
Riveting, sweating and soldering of copper/ G.I. tape ( with another copper/G.I. tape, base of the finial or any other metallic object) as required.
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for vertical run)
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for horizontal run)
Providing and fixing M.V.danger notice plate of 200 mm x 150 mm made of mild steel at least 2 mm thick, and vitreous enameled white on both sides and with inscription in signal red color on front side as required.
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning, protective covering and refilling the trench etc. of the required size:-(SSK/KEI or its equivalent make)
Armoured cable 70 sq. mm (3.5 core)
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, unarmoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-(SSK/KEI or its equivalent make)
Armoured cable 70 sq. mm (3.5 core)
Providing and laying of aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground in the same trench, in one tier horizontal formation to be laid 1 meter below the ground level including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering etc. of required size:-(SSK/KEI or its equivalent make)
Armoured cable 70 sq. mm (3.5 core)
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- (Usha - SPH Turbo HDEF 900 RPMISI or its Equivalent make)
Exhaust Fan, Light duty, (Domestic) 300 mm sweep
Exhaust Fan, Heavy duty, 300 mm sweep
Supplying and fixing stepped type Modular fan regulator on the existing modular box including making connections etc. as required.Make :-Legrand (Myrius)/L&T (Oris) / Anchor ( Roma plus)
Providing, Installation, testing and commissioning of ceiling fan without regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:- ( Usha-Technixplus BEE 3 Star rated model) or its equivalent make)
Ceiling Fan 1200 mm sweep, Category-A
Supplying and fixing Fan box of M.S.sheet with iron rod hook 12 mm.in place of junction box complete as required.
Supplying and fixing exhaust fan louver shutter for 300 mm.exhaust fan on the existing wall,painting etc, as required.(National or its equivalent make)
S/F Computer board comprising 3 No.5 amps.switch (Modular) and 3 No.3 pin 5 amps. Socket out let (Modular) and 1 No.12 Modular switch board with cover plate including connections etc,as required,complete in all respects..Make :-Legrand (Myrius)/L&T (Oris) / Anchor ( Roma plus)
Supplying and fixing of Rubber matt 1x2 mtrs.long 2.5 mm. thick (Jyoti) in the front of main panel etc,as required
Supplying and fixing shock trearment chart in main panel room on the existing wall etc, as required
Supplying and laying G.I.pipe of 40 mm. dia (Heavy duty) underground 1.00 mtr.below ground level for laying the wire/cable etc, as required
Supplying and laying G.I.pipe of 100 mm. dia (Heavy duty) underground 1.00 mtr.below ground level for laying the wire/cable etc, as required
Supply and fixing of IP40 Led fixture 40 W with Surface Mounted 4 Feet with Polycarbonate diffuser with aluminium housing minimum lumen output 4000 lumens with P.F.>0.95 with THD<10% ,CRI 80,Surge Protection 2 Kv with IP Protection of IP20 .The LEDs with minium life of 50000 burning hours.The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of ANSI Bin 5700 K with CRI of minimum 80. LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The Input voltage range shall be 150V to 270V . Driver Output voltage shall be less than SELV Limits for safe operation and maintenance.Wipro Cat. No LL24-541-XXX-57-XX or Equivalent in Philips : BN308C LED40S-6500 L120 PSU WH or Trilux:TRL-X F OTA 4000-857 ET(With five years warranty)
Supply and fixing of 2ft Led Batten 10 W surface mounted with polycarbonate diffuser and with extruded aluminum housing/polycarbonate housing minimum lumen output 1000 lumens P.F.>0.95 with THD<20% ,CRI 80,Surge Protection 2 Kv with IP Protection of IP20 .The LEDs with minium life of 50000 The LEDs used in the luminaire shall have CCT of ANSI Bin 65000 K with CRI of minimum 80. LEDs used must be tested as per EN62471 for Photobiological Safety of humans. The Input voltage range shall be 150V to 270V . Driver Output voltage shall be less than SELV Limits for safe operation and maintenance.Wipro Cat. NoLL20-111-XX-65NE3 or Equivalent in Philips : BN 021 LED10S- 6500 PSU GR S1 or Trilux:TRL-X F OTA 2000-857 ETor LT (With five years warranty)
Supplying and fixing surface mounting LED 18 watts metal round down light for soft diffuse lighting cool white and it should be compatible with specifications i.e.Power factor >0.9,Harmonic distortion <10% & efficacy >100 Lumen per watts,CRI >80 ,4000 K suitable for input voltage 220-240 Volts,50 HZ,IP rating 20,Surge rating up to 3 KV,diamensions 20.5x3.0 mm. complete with connections etc,as required. (Tisva Hector Pro Code No.DLP1832202/Pansonic/Philips or its equivalent make) (With five years warranty)
Providing and fixing MCCB four pole 32 amps to 63 amps.rating and 18 KA breaking capacity 415 volts AC.supply 50 HZ four pole DU 100 D type in the existing enclosure including making connections etc,as required. (L&T/Legrand/ABB/Siemens make)
Providing and fixing MCCB two pole 32 to 63 amps.rating and 25 KA breaking capacity 240 volts AC.supply 50 HZ two pole DU 100 D type in the existing enclosure including making connections etc,as required. (L&T/Legrand/ABB/Standard make)
Providing and fixing MCCB enclosure for DU 100 D/DU MCCB following rating on the existing board complete as required.(L&T/Legrand/ABB/Legrand make)
Supplying and fixing LED Lamp 9 watts 6500 K E-27 ,900 Lumens 240 volts AC.supply 50 HZ in the existing batten holder,pendent holder,wall bracket & bulk head fitting etc, as required.(Tisva cat. No.AL946611X/Panasonic/Philips make)
Supplying and fixing recess mounting LED 18 watts metal round down light for soft diffuse lighting cool white and it should be compatible with specifications i.e.Power factor >0.9,Harmonic distortion <10% & efficiency >100 Lumen per watts,CRI >80 ,6500 K suitable for input voltage 220-240 Volts,50 HZ,IP rating 20,Surge rating up to 3 KV,diamensions 21.2x20x3mm. complete with connections etc,as required. (Tisva EZIO Series Code No.DLP181623M/Pansonic/Philips or its equivalent make) (With five years warranty)
Providing and fixing LED Street light 25 watts aluminium die cast housing ,with Polycarbonate LENS for uniform light distribution ,AC 85-270 volts with 4MV electric surge,lumen 2400,available color temperature 6500 K,CRI 80,IP rating 66, up to 10KVA electric surge protection and bracket of steel conduit pipe 32 mm., complete with all accessories,connections,testing and commissioning etc,as required. (Wipro LR02-291-XXX-57-XX/Clair/Philips make) (With five years warranty)
Providing and fixing LED Tube fixture 36 watts surface/pendent mounting ,extruded aluminium coated body and it should be compatible with specifications i.e.Power factor >0.9,Harmonic distortion <10% & efficacy >100 Lumen per watts,CRI >80 ,6500 K suitable for input voltage 220-240 Volts,50 HZ,IP rating 20,Surge rating up to 3 KV and diamensions 121.5x5.4x7.3 mm. complete with all accessories,connections,testing and commissioning etc,as required. (Tisva Steller series code No.PL366203/Pansonic/Philips make )(With five years warranty)
Providing and fixing LED Tube fixture 36 watts recessed mounting ,extruded aluminium coated body CCT 6500 K diamensions 121.5x9.1x3.7 mm.Input voltage 130 to 270 volts,CRI 80,IP rateing 20,Surge rating upto 3 KV, complete with all accessories,connections,testing and commissioning etc,as required. (Tisva,Pansonic & Philips make) (With five years warranty)
Supplying and drawing Lan cable Cat.6,solid copper conductor protected with PVC.sheath in the existing surface/recessed steel/PVC conduit as required.( D-Link or its equivalent make)
Subhash Electrical Contractor
Bhardwaj Electrical Co.
SHARMA ELECTRICAL CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .