Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.1 LQualified Make: BPE
Model: 5 KVA UPS 120 Minute 16000 VAH Warranty 2 Years Both DELHI DELHI 110024 | SOUTH EAST DELHI | DELHI | 110024 | Make: BPE
Model: 5 KVA UPS 120 Minute 16000 VAH Warranty 2 Years Both | L1 | Qualified | |
| 2 | L2₹1.2 L+₹6,400 (5.59%)Qualified Make: LUMINOUS
Model: LUMINOUS Online UPS 5 KVA 1ST FLOOR F 05 PARKER SUITES NH 01 SECTOR 62 KUNDLI SONEPAT HARYANA 131028 SONEPAT SONIPAT HARYANA 131001 | SONIPAT | HARYANA | 131028 | Make: LUMINOUS
Model: LUMINOUS Online UPS 5 KVA | L2 | Qualified | |
| 3 | L3₹1.3 L+₹17,500 (15.3%)Qualified Make: UTL
Model: UTL-5KVA AYODHYA BYPASS ROAD BHOPAL MADHYA PRADESH 462041 | BHOPAL | MADHYA PRADESH | 462041 | Make: UTL
Model: UTL-5KVA | L3 | Qualified | |
| 4 | Disqualified Make: ACPL
Model: HFIG5000-120M-14400VAH 35 A N PATH NORTH S K PURI BORING ROAD PATNA BIHAR 800013 | PATNA | BIHAR | 800013 | Make: ACPL
Model: HFIG5000-120M-14400VAH | - | Disqualified | |
| 5 | Disqualified Make: microtek
Model: MICROTEK AND RZ R 150 CHANAKYA PLACE PART 2 UTTAM NAGAR WEST DELHI D K MOHAN GARDEN WEST DELHI DELHI 110059 | WEST DELHI | DELHI | 110059 | Make: microtek
Model: MICROTEK AND | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
20 Aug 2018, 3:00 pmClosed
Online UPS Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM with inbuilt isolation transformer IGBT-PWM with inbuilt isolation transformer Input Power single phase 160V - 260V sinewave
50Hz single phase 160V - 260V sinewave
50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz Backup time (Minutes) 120 120 Minimum VAH (VAH) 16000 16000 Warranty for UPS (Years) 2 2 Movable trolly for Batteries With With Warranty for battery 2 1
2 Degree of Protection IP21 IP21
IP20 Cabling 5 meters for input and out put With With
Without Paralleling kit for synchronising With With
Without Installation and Commissioning Yes - 1/4 CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I
II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage
Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage
Output AC Volt age
Current
Frequency
Battery Voltage and Current Yes - Indicators for mains presence
Battery charging and discharging
Output Over Load
Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C
two cycles of (12+12) hours each 2007) Yes - Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 Yes - 2/4 (reaffirmed 2007) at 55 degree C for 16 hrs Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. UQ-8326 - Type Test Certificate date 08-10-2016 - Name of Lab UKCERTIFICATIONS (ROHS) - Address of Lab NEW DELHI - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Binay Kumar Swain 790003
GSO1 INFO SYSTEMS HQ 5 Mtn Div C/o 99 APO PIN 908405 1 15
406060
GEM/2018/B/57464
Online UPS
15 days
Arunachal Pradesh; West Kameng
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Online UPS Online UPS ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Rating in KVA (KVA) 5.0 KVA 5.0 KVA Technology IGBT-PWM with inbuilt isolation transformer IGBT-PWM with inbuilt isolation transformer Input Power single phase 160V - 260V sinewave | - | - | - |
| 50Hz single phase 160V - 260V sinewave | - | - | - |
| 50Hz Output power Single phase 230V +/-1% sinewave 50 Hz Single phase 230V +/-1% sinewave 50 Hz Backup time (Minutes) 120 120 Minimum VAH (VAH) 16000 16000 Warranty for UPS (Years) 2 2 Movable trolly for Batteries With With Warranty for battery 2 1 | - | - | - |
| 2 Degree of Protection IP21 IP21 | - | - | - |
| IP20 Cabling 5 meters for input and out put With With | - | - | - |
| Without Paralleling kit for synchronising With With | - | - | - |
| Without Installation and Commissioning Yes - 1/4 CONSTRUCTIONAL Minimum thickness of M.S.Sheet Enclosure duly painted (mm) 1.2 - Type of Battery SMF-VRLA conforming to JISC:8702(Pt.I | - | - | - |
| II&III) - FUNCTIONAL Maximum overshoot and Under shoot of output rated voltage 4 - Voltage Regulation from no load to full load (%) </= 3% - 20% Overload limit for minimum 10 minutes Yes - Overall Efficiency (%) >/=90% - Total Harmonic Distortion(THD) (%) Maximum 3% - 50% Overload limit for minimum 1 minutes Yes - PROTECTION Protection for under voltage at battery terminal at 10.5V per 12 V battery. Yes - Protection of Over voltage | - | - | - |
| Short Circuit & over load at UPS output terminal Yes - METERING AND INDICATIONS Digital Metering in UPS for AC Input Voltage | - | - | - |
| Output AC Volt age | - | - | - |
| Current | - | - | - |
| Frequency | - | - | - |
| Battery Voltage and Current Yes - Indicators for mains presence | - | - | - |
| Battery charging and discharging | - | - | - |
| Output Over Load | - | - | - |
| Low Battery Voltage Yes - REPORTS AND CERTIFICATION Damp Heat : in accordance with IS:9000(part 5/sec.2)1981 at Temperature of 40 degree C | - | - | - |
| two cycles of (12+12) hours each 2007) Yes - Dry Heat Test : in accordance with IS:9000 (part 3/sec.5)1977 Yes - 2/4 (reaffirmed 2007) at 55 degree C for 16 hrs Cold Test : in accordance with IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) at -10 degree C for 4 hrs. Yes - Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab covering all technical requirements. Yes - Type Test Certificate No. UQ-8326 - Type Test Certificate date 08-10-2016 - Name of Lab UKCERTIFICATIONS (ROHS) - Address of Lab NEW DELHI - As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Binay Kumar Swain 790003 | - | - | - |
| GSO1 INFO SYSTEMS HQ 5 Mtn Div C/o 99 APO PIN 908405 1 15 | - | - | - |
Exempted
20 Aug 2018
31 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_406060.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .