| 1 | | Supply of LED flood light of 300 Watt (MB/NMB as per site requirement) with high pressure die cast Aluminium / standard alloy housing and LEDs of approved make pasted on diecast housing, driver installed on cast aluminium housing and prewired upto the terminal block. It has a luminaire efficacy of not less than 110 lm/W, CCT of 5700 K, suitable for outdoor applications complete as per technical specifications. | 70 | Each | Brijesh Kumar Rajpoot 221006,Lal Bahadur Shastri International Airport, Babatpur, Varanasi-221006 | 120 |
| 2 | | Dismantling of existing flood lights from the existing High Mast by loweing the carriage using existing motorized pulley including removing the existing installed flood lights of various ratings along with any other accessories complete as required and depositing the dismantled fittings to AAI store as per the direction of Engineer in charge complete as per site requirement. | 40 | Job | Brijesh Kumar Rajpoot 221006,Lal Bahadur Shastri International Airport, Babatpur, Varanasi-221006 | 120 |
| 3 | | Installation, testing and commissioning of Flood lights on existing High Mast (set of approx. 12 Nos. light fittings on each high mast) along with providing and fixing of suitable clamp, nut, bolts etc. as required including provision of rubber type or suitable counter-balancing arrangement required to maintain the horizontal level of the carriage and prevent any unbalance, including lifting the high mast carriage using existing motor pulley, including making connections to the LED flood lights, testing and commissioning complete as required as per site requirement.
( 01 Job - Installation of 1 set of fittings on 01 High Mast). | 4 | Job | Brijesh Kumar Rajpoot 221006,Lal Bahadur Shastri International Airport, Babatpur, Varanasi-221006 | 120 |
| 4 | | Supply of 6.00 mtrs. long OCTAGONAL hot dipped galvanised high mast pole suitable for wind speed as per IS-875 with suitable circular bracket as per OEM and clamps suitable for installation of min. 09 number LED luminaire facing one side, pole fabricated out of minimum 3 mm sheet, in single section, suitable for installation on a precast foundation with supply of minimum 4 nos. of foundation bolt and template, rigid flange plate welded with the base of pole for fixing on foundation bolts complete as reqd. for structural stability as specified, weather proof and vandal resistance door of height not less than 300 mm, flush with the exterior surface, including supply and fixing of suitable size Weather proof box (near bottom of pole) containing a terminal plate of backlite sheet with 32 Amp connector and insulated caps for cable terminations suitable for cable up to 4C X 25 sq.mm., including 3 core 6 Sq.mm cables (for connection from bottom of pole to LED fittings at top of pole as per site conditions) and 10A, DP MCB-03 Nos., earthing bolts for continuous earth connections, including supply and fixing low intensity aviation LED light complete as required and as specified. | 1 | Each | Brijesh Kumar Rajpoot 221006,Lal Bahadur Shastri International Airport, Babatpur, Varanasi-221006 | 120 |
| 5 | | Erection of G.I.OCTAGONAL High Mast of height as mentioned below along with ring type bracket with all accessories in reinforced cement concrete 1/2/4 (1 cement / 2 coarse sand / 4 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling including positioning of template and foundation bolts (supplied with pole to match with pole base plate) and providing and fixing of HDPE pipe of size 63 mm dia (1 pieces of approx 0.75 m length) in the foundation for loop-in-loop-out of the cable to the pole complete as required and as specified.
A) Above 4.5 metre and upto 6.5 metre | 1 | Each | Brijesh Kumar Rajpoot 221006,Lal Bahadur Shastri International Airport, Babatpur, Varanasi-221006 | 120 |
| 6 | | Installation, testing and commissioning of Flood lights on existing High Mast pole (set of approx. 10 Nos. light fittings on each high mast pole) including making suitable connection, along with providing and fixing of suitable clamp, nut, bolts etc. including provision of suitable counter-balancing arrangement as required to maintain the horizontal level of the circular bracket and prevent any unbalance, complete as required as per site requirement.
( 01 Job - Installation of 01 set of fittings on 01 High Mast) | 1 | Job | Brijesh Kumar Rajpoot 221006,Lal Bahadur Shastri International Airport, Babatpur, Varanasi-221006 | 120 |
| 7 | | Supply of following sizes of 1.1 kV grade XLPE insulated copper conductor armoured stranded/solid Control Cable conforming to IS 7098 (Part 1) 1988 complete as required and as per specifications.
A) 24 C X 2.5 sq.mm. | 880 | Metre | Brijesh Kumar Rajpoot 221006,Lal Bahadur Shastri International Airport, Babatpur, Varanasi-221006 | 120 |
| 8 | | Supply of XLPE insulated, PVC innersheathed, armoured aluminium cable,1100 V as per IS 7098 (Part 1) 1988 with upto date amendments of following sizes-
A) 4 C X 25 sq.mm. | 600 | Metre | Brijesh Kumar Rajpoot 221006,Lal Bahadur Shastri International Airport, Babatpur, Varanasi-221006 | 120 |
| 9 | | Supply of following sizes HDPE Pipe suitable to lay in underground as per IS-4984/95 duly ISI marked,
i) 63 mm outer dia PE80, PN10 | 775 | Metre | Brijesh Kumar Rajpoot 221006,Lal Bahadur Shastri International Airport, Babatpur, Varanasi-221006 | 120 |
| 10 | | Laying of following size HDPE /GI pipe in ground up to depth of approx 0.75 meter including covering with excavation and refilling the trench, consolidation and making good the surface etc. complete as required.
a)Upto 63 mm dia | 702 | Metre | Brijesh Kumar Rajpoot 221006,Lal Bahadur Shastri International Airport, Babatpur, Varanasi-221006 | 120 |