SE
SE OMC-V ATPS Anpara
Round the clock checking Breakdown preventive maintenance and operation of dust extraction dust suppression system ventilation fans sump pumps Air conditioning System OTIS make elevator and other miscellaneous work of the CHP 3 x210 MW ATPS
2022_RVUNL_678193_1
T-01/CHD-I/ATPS/2022-23
Open Tender
Repair and Maintenance Works
Fixed-rate
365 days
ATPS Anpara
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Dy CAO CFA and BO ATPS Anpara
₹30,000
20 Jun 2022
14 Mar 2022
28 Apr 2022
14 Mar 2022
26 Apr 2022
14 Mar 2022
Amount
Section A: Round the clock checking/ minor maintenance and operation of Dust Extraction / Suppression System, Ventilation Fans and Sump Pumps, Maintenance of water pipeline system of the CHP ‘A’ TPS, Anpara”
Checking/minor routine maintenance & round the clock operation of dust extraction /suppression system /ventilation fans/ sump pumps.
Removal /replacement of old and damaged pipe line of following sizes 25 mm to 150 mm
Removal /replacement of old and damaged pipe line of following sizes 151 mm to 400 mm
Repair /replacement of M.S./G.I. bends or flanges and repair/ replacement of valves of having sizes:25 mm to 80 mm
Repair /replacement of M.S./G.I. bends or flanges and repair/ replacement of valves of having sizes:81 mm to 250 mm
Fabrication & erection /repairing of supports for M.S. /G.I. pipe line.
Excavation for fixing the support & back filing
Attending leakages in pipe line by welding.
Servicing of valves of sizes 25 mm to 80 mm
Servicing of valves of sizes 81 mm to 250 mm
Servicing of valves of sizes 251 mm to 400 mm
Servicing/ replacement of nozzles
Flushing of header installed at TPs (joint to joint) at one location.
Flushing of pipeline of CCR building/office building /track hopper area.
Overhauling of pressure releasing valves.
Overhauling pump 05 KW to 15 KW motors
Repair/ replacement of shaft ,impeller of pump of 05 KW to 15 KW motors
Replacement of bearing / repairing of bush/ sleeve/ star in pump
Adjustment of coupling /shaft
Adjustment of auto float switch
Repairing of foundation of sump pumps
Replacement / complete servicing of bearing /plumber block.
Repair /replacement of shaft of fan
Replacement of canvas of one no. D.E. system /ventilation fan
Servicing of Damper /removal jamming.
Complete flushing of nozzles and ring header pipe of cyclone chamber of D.E. system.
Replacement of flexible hose pipe.
Repairing / replacement of impeller of V.F.
Removal of choking in bend pipes of D.E. system.
Adjustment of impeller, fitting the same on shaft, ensuring the proper clearance with casing, alignment, and removal of vibrations to ensure smooth operation of Ventilation fan.
Repair /replacement of tie rod.
Proper checking and maintenance of suction duct for smooth operation including complete checking & tightening of nut-bolts, replacement of duct joints whenever required, removal of coal dust/slurry/foreign material from the duct manually with help of compressed air after cutting the duct, followed by its sealing, proper adjustment of opening including their smooth and free operation and proper sealing of the For Dust Extraction System
Proper checking and maintenance of suction duct for smooth operation including complete checking & tightening of nut-bolts, replacement of duct joints whenever required, removal of coal dust/slurry/foreign material from the duct manually with help of compressed air after cutting the duct, followed by its sealing, proper adjustment of opening including their smooth and free operation and proper sealing of the For Ventilation system
Removal, cleaning and refitting of filter panels (blocks) provided in supply and discharge end ventilation Fans
Repair of duct/extraction hood etc.(up to 100mm x100mm size)
Section B: “Work of Operation, checking, routine/preventive/breakdown maintenance works of air conditioning system of the CHP, ATPS Anpara”“
Operation & routine maintenance of Air Conditioning system & Aqua-guard Water cooling system during as per scope of work
Preventive/breakdown maintenance of Air Conditioning system.
Painting & Polishing of Air Conditioning system.
Preventive/ Breakdown maintenance of Aqua-guard Water system.
Preventive/breakdown maintenance of Water cooler system.
Section C: “Routine minor maintenance of OTIS make elevator installed in the service building ATPS for Zero meter to 54 meters levels for CHP 3X210 MW ATPS”
Round the clock operation, routine minor maintenance of lift
Painting & Polishing, as and when required for OTIS make elevator.
Cleaning & Sweeping of the floor area in front of 06 No. doors at different level (zero meter to 54 meters.etc.) & Machine room for OTIS make elevator.
M/S AIR FREEZE
M/S UNIVERSAL ENGINEERING WORKS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .