Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹24.8 L+₹84,684.50 (3.53%)Rejected-Finance AT POST SAHAJPUR RANMALA TAL DOUND DIST PUNE 412202 | PUNE | MAHARASHTRA | 412202 | L2 | Rejected-Finance High Rate | |
| 3 | L3₹26.1 L+₹2.1 L (8.60%)Rejected-Finance | L3 | Rejected-Finance High Rate | |
| 4 | L4₹26.2 L+₹2.2 L (9.21%)Rejected-Finance MOURYA HEIGHTS SATAVNAGAR HANDEWADI ROAD HADAPSAR PUNE 28 | PUNE | MAHARASHTRA | 411028 | L4 | Rejected-Finance High Rate | |
| 5 | L5₹27.2 L+₹3.2 L (13.3%)Rejected-Finance C 1 502 MANDKE ADVANTAGE HOME SOCIETY LULLANAGAR PUNE 411 040 | PUNE | MAHARASHTRA | 411040 | L5 | Rejected-Finance High Rate |
Tender Value
₹42.8 L
EMD Value
₹85,500
Closing Date
30 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (Central) Pune
Garrison Engineer (Central) Pune-411001
8596 SPL REPAIR AT BASEMENT OF BLDG NO P-83, P-90 AND P-91 AT AFMC UNDER GE (CENTRAL) PUNE
2025_MES_706470_1
8596 SPL REPAIR AT BASEMENT OF BLDG NO P-83, P-90 AND P-91 AT AFMC UNDER GE (CENTRAL) PUNE
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer (Central) Pune
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer (Central) Pune
₹85,500
Yes
18 Jul 2025
2 May 2025
2 Jun 2025
2 May 2025
30 May 2025
16 May 2025
Amount
Dismantling of stone slab or tiles in any description or thickness, laid bedded jointed in any morter.
Demolition of brick work or stone/ boulders masonry, built in cement mortar including all quoins, arches, pillars etc. but excluding ashlars facing, dressed stone work and precast concrete articles
M&L for vitrified ceramic tiles 8 to 9mm thick (square/ rectangular) polished, area of Each tiles not exceeding 0.36 Sqm, in floor etc set jointed and pointed in white or coloured cement to match the colour of tiles with screed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:6. all as specified.
. --Ditto-- all as per item No 3 above but as in skirting over & including 10mm thick backing coat of CM 1:4 on any type of masonary surfaces including traigular filleting in cement mortor in 1:4 complete all as specified and directed.
M&L for glazed ( glossy or matt finish) ceramic coloured, designer & pattern (dark & light shade combination) tiles in 450 x 300 x 7-8 mm thick on vertical surfaces such as dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match over with and including 10mm thick backing coat in CM 1:3 and filleting filleting in cement mortor in 1:3 complete all as specified and directed.
Demolition of Concrete of any description and in any position not otherwise specifically provided for etc Complete.
M&L for 75mm thick Cement concrete type D2 1:4:8 (using 40mm graded stone aggregates) as in sub base course.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including screed bed or bedding layer of 15 mm thick in CM (1:6) all as specified and directed by Engineer-in-charge.
. --Ditto-- all as per item No 08 above but as in in riser of steps, skirting, dado and pillar & including 10mm thick backing coat of CM 1:4 on any type of masonary surfaces including filleting.
M&L for 18mm to 20mm thick Granite work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platfoms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
Rounding to edges of stone slabs one edge, such as in steps, Cooking platform, and other similar situations
Complete removal of existing treatment and M&L for applying thin layer wall care putty and applying two coats of oil bound distemper including a coat of primer on walls all as spd and directed.
M&L for preparation of old decorative surfaces of ceiling incl, cornices (plastered or unplastered) by brooming down and scrapping wherever necessary and including applying one coat of oil bound distemper on ceiling all as spd and directed.
Taking down Chowkats or frames with shutters (w/o taking of shutters from the frame) exc. 1.5 Sqm but n.exc. 4 Sqm & removing from site.
Taking down Chowkats or frames with shutters (w/o taking of shutters from the frame) area n. exc 1.5 Sqm removing from site
S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides.
S&F 100 mm long SS hinges all as spefied and directed.
S&F 150 mm long Aluminium anodised barrel tower bolt of extruded section.
Supply and fix 150mm long Extruded aluminium alloy handles, 150mm long fabricated type., anodised
S&F 300 mm long Aluminium alloy anodised sliding door bolt with hasp staple (bolt type ) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminum alloy.
Supply and fix in repairs floor door stopper of aluminium body and tongue anodised with hard drawn steel spring fixed in floor over all length of cover plate 150mm.
S&F, Powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S&F Powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con-forming to Fe 290.Gde-E-165
M&L for precast cement concrete block masonry exceeding 10cm in width with solid blocks of PCC (1:5:8) gde C-5 and setting in CM 1:6.
Taking down cement plaster on stone / Brick walls including raking out joints, hacking for key, scrubbing down with water all as specified
M&L for rendering 5 mm thick plaster on ceiling concrete surfaces as in CM (1:3) finished even & Smooth without using extra cement.
M&L for 15mm thick rendering in CM 1:4 over brick / conc wall surfaces trowelled to even & smooth w/o using extra cement for internal wall surfaces complete.
M&L for rendering 15mm thick plaster on fair faces of brick work or concrete surfaces (1:6) finished the surface even and Smooth without extra cement.
M&L for applying three coat of white wash to newly plastered surfaces of on ceiling.
M&L for preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide or zink chrome primer on new steel urfaces al as specified.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bond distemper over one or two coats of putty including one coat of primer all as specified & directed by Engineer-in- Charge.
M&L for Finishing walls with Acrylic Smooth exterior paint of required hade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
M&L for 75mm thick PCC (1:3:6) type B2 (using 20mm graded store aggregate) as in plinth protection/hard standing, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with any type of unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge.
M & L for point wiring with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia / PVC Casing & Caping not less then (20 x 12 ) mm including all accessories/ fittings such as junction boxes, bends, tee, elbow etc alongwith required size Modular boxes including modular frame / cover plate suitable for mounting switches /sockets etc including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:-
One light / Exhaust Fan/Ceiling fan & One Bell/buzzer point controlled by one switch.
One switch socket outlet point 3 pin 5 Amps on Independent board.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/ side the switch board of light point in same vertical / horzintal plane.
One 3 pin 6/5 Amp socket outlet Same board.
Material and labour for Point wiring complete with 2 run of 2.5 sqmm single core PVC FRLS insulated heavy duty ISI Marked , unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including suitable size of PVC white non metalic conduit with all accessories like tee, straight joint, L Bend etc., concealed on wall surface on ceiling / roofs etc., and including provision of PVC insulated heavy duty ISI Marked unsheathed copper conductor 1.5 sqmm for earth continuity conductor and connected to common earth dolly, including suitable size of sheet metal box 1.6mm thick fixed and flushed inside the walls, with 3mm thick laminated sheet top cover for housing the switches/socket outlets 15 Amps.
All as per item no 39 here-in -before but for One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/ side the switch board in same vertical / Horzintal plane.
Taking down old unserviceable/worn out sub main wiring of any type and size complete all as specified.
Taking down Earth plug/DBs of any make and type including MCBs/MCCBs etc. complete and making good the disturbed surfaces including colour wash complete all as specified.
Taking down fan/Ex Fan/Wall Fan any sweep any type and size, keeping with safe custody and refixing the same with replacement of 3 core PVC insulated PVC sheated 3 core multistranded copper conductor cable of appropriate size as specified/directed, from ceiling rose to fan terminal, S & F capacitor of suitable capacity, over hauling the fan complete all as specified and as directed.Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.
Material and labour for sub main wiring with two single core PVC FRLS insulated unsheathed copper conductor cable 2.5 sqmm drawing in and including PVC Casing/casing of suitable size on wall/surface on ceiling with one additional PVC wire of copper conductor of 2.5 sqmm for earth continuity conductor complete all as specified and directed by EIC.
Material and labour for sub main wiring with two single core PVC FRLS insulated unsheathed copper conductor cable 6 sqmm drawing in and PVC casing/caping of suitable size on wall/surface on ceiling with one additional PVC wire of copper conductor of 6 sqmm for earth continuity conductor complete all as specified and directed by EIC.
Material and labour for sub main wiring with two single core PVC insulated unsheathed copper conductor cable 4 sqmm drawing in and including suitable size PVC -FRLS Casing and caping wall/surface on ceiling with one additional PVC wire of copper conductor of 4 sqmm for earth continuity conductor complete all as specified and directed by EIC.
S&F as in bracket holder/ Angle lamp holder fixed on wall /ceiling all as approved and directed by Engineer-in-charge.
Supply and Fixing as in replacement of LED 18/20 Watt light fitting Baton integrated LED channel, integral sleek extruded polycarbonate LED Channel with white acrylic cover and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete with all accessories all as specified and directed by Engr-in-Charge.
S&F in replacement of LED light fitting surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver complete in all respect of 10W capacity.
Material and labour to perform core drilling on brick/masonry walls with a thickness of up to 18 inches, drilling shall crate holes with a diameter ranging from 2 to 4 inches, using suitable machinery and equipment. The contractor shall provide all necessary materials, labour, and eqpt reqd to perform the work. The contractor shall ensure that the drilling prices is executed without damaging the surrounding structure, any scaffolding, ladders, or additional support structures necessary to perform the job shall be arranged by the contractor under the job complete all as spd and directed by the EIC.
Supply and fix as in replacement of ceiling fan down rod GI pipe of 15 mm bore, duly arrangement of hole and cutting of pipe etc of size 4/6 Feet long complete all as spd and directed.
Supply and fixing as in replacement of building security LED fitting upto 40 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete along with suitable size /bore GI pipe bracked duly cut to size and bent to shape , duly painted incl necessary clamps as required to fix on concrete / steel poles incl taking old unsve light & GI bracket any type and size complete all as specified and as directedby EIC
S & F as in replacement ceiling rose Ceiling rose, 3 phase/PVC/polycarbonate, isolated body all as specified and directed.
S & F as in replacement modular switch 6A SP one - way 230V white ivory finish complete all as specified
S & F as in replacement modular switch 16A SP one - way 230V white ivory finish complete all as specified
S & F as in replacement modular socket outlet 2/3 pin 6 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified.
S & F as in replacement modular socket outlet 2/3 pin 16 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified.
S & F as in replacement Modular type stepped electronic fan regulator all as specified & directed
Supply & Fixing as in replacement of SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, incl taking down old UNSV SPN DB any type and size complete all as specified and directed.
Supply and fix as in replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, single pole all as directed by EIC.
Supply & Fixing as in replacement of MCB SPN, 40 to 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked complete all as specified and directed.
Supply & Fixing as in replacement of MCB SP, 06 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked complete all as specified and directed.
Supply & Fixing as in replacement of TPN DB 4 Way distribution Box, double door in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar complete incl taking down old UNSV TPN DB any type and size complete all as specified and directed.
Supply & Fixing as in replacement of MCB TPN DP 63 Amps 440 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked complete all as specified and directed.
M&L as in replacement for earthing with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).
Material and labour for taking down of split type AC any type and Capacity duly storing of its refrigerant, disconnecting its both the copper tubes from indoor and out door unit carefully, taking its inner and outer unit and refixing the same in other side of wall/location as directed by EIC , duly filling of make up refrigerant as per desired pressure, minor brazing/welding in copper tubing, making all elect connections as before and testing all as spd and direted by EIC
Supply and fixing as in replacement of LED luminaire (white/warm Lt) 600 mm x 600 mm, 36 watt, 220 V AC recessed/surface type with high efficiency soft glare free light complete with driver, holders & LED lamp suitable for surface/ceiling (as per site requiremt) including connecting up with driver three core flexible copper conductor cases of suitable size complete all as per sample approved by EIC.
M/S Abhishek Builders (BID ID -3303015)
Parhar Enterprise (BID ID -3303464)
Gauri Associates (BID ID -3308981)
PRANAV ENTERPRISES (BID ID -3302440)
M/s Asrani and sons (BID ID -3303673)
M/s.BAJRANG CONSTRUCTION (BID ID -3303266)
ANIL CONSTRUCTION CO. (BID ID -3303482)
Suma Construction (BID ID -3309094)
UNIQUE ENGINEERS (BID ID -3309271)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .