Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹24.0 L+₹98,886 (4.30%)Rejected-Finance NEW HOSPITAL ROAD UDHAMPUR UDHAMPUR UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹26.9 L+₹3.9 L (17.1%)Rejected-Finance B 56 LANE NO 4A SECTOR 7 VASHNAVI ENCLAVE CHANNI HIMAT JAMMU 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹28.9 L+₹5.9 L (25.7%)Rejected-Finance WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance BEING L4 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
12 Jul 2024, 6:00 pmClosed
GE AF UDHAMPUR
GE AF STN UDHAMPUR
REPAIR/REPLACEMENT/MAINT OF CEILING FAN/ EXHAUST FAN /GEYSER/PEDESTAL FAN/WALL MOUNTED CEILING FAN/ SUBMAIN WIRING/MCBs / DBs/ 3 PHASE SOCKET / INDUSTRIAL SOCKET/SERVICE CONNECTION A/W CERTAIN CONNECTED WORKS AT VARIOUS LOC OF 39 WING AF STN UDHAMPUR
2024_MES_659573_1
GE/AFU-27/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE AF STN UDHAMPUR
PLEASE REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE AF UDHAMPUR
₹80,000
19 Nov 2024
14 Jun 2024
15 Jul 2024
14 Jun 2024
12 Jul 2024
28 Jun 2024
14 Jun 2024 - 21 Jun 2024
Amount
Taking out burnt/damaged copper winding wire of 1200/1400mm Sweep ceiling fan motor of any make and M&L for rewinding of ceiling fans motor of any make with super enameled copper winding wire of appropriate size/same gauge as original including ,soldering, varnishing , ball bearing, push,locking pin and certain minor repair along with minor repair/replacement work-as-such Ruber rill,louring pin,flexible wire from ceiling rose to ceiling fan etc and assembling and testing and refixing of same places complete all as specified.
Taking out burnt/damaged copper winding of Wall mounted fan 400mm motor of any make and M&L for rewinding of wall mounted fans motor of any make with super enameled copper winding wire of appropriate size/same gauge as original, including packing insulating material, soldering, varnishing, including painting etc and certain minor repair such as such as flexible wire/cord oiling greasing etc complete all as specified.
Taking out burnt/damaged copper winding of Wall mounted fan 600mm motor of any make and M&L for rewinding of wall mounted fans motor of any make with super enameled copper winding wire of appropriate size/same gauge as original including insulating,soldering, varnishing, etc such as flexible wire /cord/oiling greasing etc certain complete all as specified.
Taking out taking down refixing burnt/damaged wire of pedistal fan any size motor of any make and M&L for rewinding of fans motor of any make with super enameled copper winding wire of appropriate size/same gauge as original including packing insulating , soldering, varnishing, assembling and testing and refixing of same places complete all as specified.
Taking out burnt/damaged wire of exhaust fan 200 to300 mm motor of any make and M&L for rewinding of fans motor of any make with super enameled copper winding wire of appropriate size/same gauge as original including insulating , soldering, varnishing, assembling and testing including taking down and refixing using etc of same places complete all as specified. all as specified.
Taking out burnt/damaged wire from exhaust fan motor of 400 to 450 and M&L for rewinding of with super enameled copper winding wire of same size, gauge & weight including packing insulating material, soldering, varnishing, including painting and certain minor repair such as flexible wire/cord oiling,greasing etc assembling and testing including refixing using fastner etc. complete all as specified varnishing & insulating complete and refixing of same places complete all as specified and directed.
Taking down dismaintilling UNSV/Rusted fatal/damaged Exhaust Fan MS / iron body of any size and any make and repairing the following items of existing sizes.
Exhaust Fan motor suitable for 400 to 450 mm
Exhaust fan frame with nut bolts etc size 400to 450 mm sweep
Exhaust fan Louver iron shutter for size 400 to 450mm sweep along with fixing arrangement
Exhaust Fan motor suitable for 250 to 300 mm
Exhaust fan frame with nut bolts etc size 200to 300 mm sweep
Exhaust fan Louver iron shutter for size 250 to 300mm sweep along with fixing arrangement
Taking down dismaintilling UNSV/Rusted fatal/damaged Ceiling Fan from of any size and any make and repairing the following items of existing sizes.
Ceiling Fan motor suitable for 1200 mm
Ceiling fan winds(sweep)1200mm set etc size
Ceiling fan conopy set of two suitable for existing fan.
Ceiling fan down rod suitable 1200mm ceiling fan.
Ceiling fan fixing arrangement/hook with nuts bolts /locking pin system
Standard ball bearing for suitable 1200/1400 mm ceiling fan suitable for diffrent makes of fans of aproved quality including necessary
S&F in repairs down rod 30 cms long made out of heavy grade M.S pipe with necessary threading at both ends, holes as required matching with existing & painting for size of ceiling fan 1200mm/1400 mm as all directed by Engineer-in-Charge. Make :- Orient/Usha/Khaitan or as directed by GE.
S&F in repairs down rod 60 cms long made out of heavy grade M.S pipe with necessary threading at both ends, holes as required matching with existing & painting for size of ceiling fan 1200mm/1400 mm as all directed by Engineer-in-Charge. Make :- Orient/Usha/Khaitan or as directed by GE.
S&F in repairs rubber bushes and real synthetic rubber with 14.5 mm hole suitable for fan hooks for hanging of ceiling fans all directed by Engineer-in-Charge.
S&F in replacement fasteners size of nut less than25 mm clamp with complete set of appropriate size for hanging of ceiling fan all directed by Engineer-in-Charge.
Supply and fixing of Surface mounting clamps for PVC pipe clearince saddle clamps25/40/50 /60/75 mm complete all as specified and as directed.
S&F in replacement condenser/capacitor suitable for 230 volts single phase for ceiling fan/exhaust fan/cabin fan/pedestal fan of capacity 2.5 mfd ISI mark including necessary connection complete all as specified.
S&F in replacement condenser/capacitor suitable for 230 volts single phase for ceiling fan/exhaust fan/cabin fan/pedestal fan of capacity 3.15 mfd ISI mark including necessary connection complete all as specified.
S&F in replacement condenser/capacitor suitable for 230 volts single phase for ceiling fan/exhaust fan/cabin fan/pedestal fan of capacity 4 mfd ISI mark including necessary connection complete all as specified.
Painting one coat of synthetic enameled paint by spraying to ceiling fans/E/fan of any type in MES store yard including preparation to old painted surfaces by filling cavities etc and overhauling by providing correct grade of lubricant oil/wheel bearing grease complete including taking down and refixing of same places making/writing of MES No all as directed by Engineer-in-charge.
Supply and replacement exhaust fan frame cover,louver , made out of M.S sheet of any make and size as per existing exhaust fan with suitable size of nuts, bolts & washers complete all as specified and directed by Engineer-in-Charge.
Cutting of existing wall and fixing of Exaust fan total making good plaster and white wash and suitable size of 04 Number faishner and fixing of any type exhaust fan complete all as specified and as directed .
Supply and fixing of PVC Exhaust Fan 150 mm sweep with lovour complete all as specified and as directed
Supply and fixing of PVC Exhaust Fan 200 mm with lovour complete all as specified and as directed.
Supply and fixing of PVC Exhaust Fan 250 mm Rust free Body ,copper motor with lovour complete all as specified and as directed.
Supply and fixing of PVC Fan 300 mm with lovour complete all as specified and as directed.
Taking down geysers of any type and any capacity due to rusting of bolts/seepage of wall and re-installation at any location including S&F in repairs of heavy duty pin type fastener 4” long and making necessary inlet/outlet electric & water supply connections from existing source to geyser complete all as specified and as directed.
S&F in repairs heating element, cup (round) type, 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA/Bajaj/Recold/Venus.
Description all as per serial item No.26 here-in-before but in tikona type Make : USHA / Bajaj / Recold.
S&F in repairs heating element, cup (round) type, 2.00 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of any make complete all as specified and as directed. Make : USHA/Bajaj/Recold/Venus.
Description all as per serial item No.28 here-in-before but in tikona type Make : USHA / Bajaj / Recold.
S&F in repairs 7 " thermostat switch for geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed. Make : USHA / Bajaj / Recold / Theta / Elcon.
S&F in repairs 11" thermostat switch for geysers of 25/50 ltrs capacity (ISI marked) complete all as specified and as directed. Make : USHA / Bajaj / Recold / Theta / Elcon.
S&F in repairs inner stainless-steel inner tank of 20 gauge sheet rated pressure not less than 8kg/sqcm suitable for 25 ltrs capacity geysers complete all as specified and as directed.
S&F in repairs inner stainless-steel inner tank of 20 gauge sheet rated pressure not less than 8kg/sqcm suitable for 50 ltrs capacity geysers complete all as specified and as directed.
S&F in repair base 09/06 Nuts assembly, compatible to existing geyser, with inlet and thermostat pipe with drain plug inclusive of clamps for holding the element with nuts, bolts and gasket complete all as specified and as directed.
Taking down UNSV/ Rushed / fatal hot water geyser capacity 25 Ltrs / 50 Ltrs from OTM / Mess / Accn etc of any make and repairing / Installation at same location by replacement of following items-
Outer body of geyser Cap-50 Ltrs along with PV foam for heat retaining
Outer body of geyser Cap-25 Ltrs along with PV foam for heat retaining
Steel Inner tank of geyser cap-50 Ltrs, pressure ratintg 0.8 bar
Steel Inner tank of gyser cap-25 Ltrs, pressure ratintg 0.8 bar
Base plate with indicator suitable for cap-50 Ltrs
Base plate with indiactor suitable for Cap-25 Ltrs
Geyser assy suitable for Cap-50 Ltrs
Geyser assy suitable for Cap-25 Ltrs
Element suitable for Cap-50 Ltrs Geyser & 5 star rating
Element suitable for Cap-25 Ltrs Geyser & 5 star rating
Thrmostate suitable for 50 Ltrs Geyser
Thrmostate suitable for 25 Ltrs Geyser
S&F in repairs indicator lamp for geyser of any type colour green & red complete all as specified and as directed. Make : Usha / Bajaj/ Crompton
S&F in repairs plug top 3 pin 15 Amp ISI marked complete all as specified and as directed. Make Anchor / Havells / Bajaj .
S&F in repairs bottom cover of MS sheet 20 gauge suitable for 25 /50 ltrs capacity geysers and providing a coat of red oxide to inner surface and applying one coat of synthetic enamel paint by spray painting to outer surface complete all as specified and as directed.
S&F in repairs brass non-return valve 15 mm bore ISI marked screwed both ends and connecting to iron pipe in repairs complete all as specified and as directed. Make : Neta metal works/Orient/Leader/Bir.
Supply and fixing Plug socket board with metal socket and plug DP 20 Amp (I Phase ,1 Neutral and earth ) complete including taking down all as specified and as directed. (Make Legrand/ indoasian/ havells)
S&F in repairs pressure safety value confirming to relevant IS with washer suitable for 15 mm GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed. Make : Theta / Usha or ISI marked
S&F in repairs of pressure release valve, confirming to relevant IS with washer suitable for 15mm bore GI pipe suitable for 25/50 ltrs geysers complete all as specified and as directed. Make : Leader/ Theta or ISI marked.
S&F in repair of GI tubing medium grade of size 25mm bore ISI marked galvanized with all fittings such as bends, elbows, tees, check nuts, unions nipples etc for cold water pipe line complete all as specified and as directed.
Description all as per item No 43 here-in-before but 20mm bore.
Description all as per item No 43here-in-before but 15mm bore.
S&F in repairs of Heavey Stainless steel geyser connection pipe 304 Grade Graiding for extra connection icomplete all as specified and as directed. (size 18" mm)
S&F in repairs of Heavey duty PVC pipe( 36" inch for geyser connection pipe for extra connection complete all as specified and as directed. Make : Usha / Bajaj/ Crompton
Supply and fixing of Plug type bib taps, cast iron, screwed for iron pipe and fixed of size 15/20 mm bore dia
Stop valves/angle vale 15mm , cast copper alloy, screwed down, high pressure,with crutch or butterfly handle, screwed both ends for ironpipe or for unions and fixed
M&L in repair of single pole and earth encloser with three pin and earth plug plus neutral with socket 32/40 Amps 240Volts complete indrustial type with Tripple pole MCB complete all as specified and directed
M&L in repair plastic type DBs SPN 2 way flush mounted including accessories therein and disposing off complete all as specified and directed.
M&L in repair of tripple pole and earth encloser with three pin and earth plug plus neutral with socket 63 Amps 415 Volts complete indrustial type with Tripple pole MCB complete all as specified and directed
M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring concealed in wall/false ceiling with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
One light/Fan/Exhaust fan point controlled by one switch
One light point controlled by two way switches
One bell/buzzer point controlled by one push button on the same board with other switches or independent
One 5 pin 5 Amp switch socket out let point on the same board with other switches
One 5 pin 5 Amp switch socket out let point on an independent board
M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in existing conduit with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
One light/Fan/Exhaust fan point controlled by one switch
One light point controlled by two way switches
One bell/buzzer point controlled by one push button on the same board with other switches or independent
One 5 pin 5 Amp switch socket out let point on the same board with other switches
One 5 pin 5 Amp switch socket out let point on an independent board
M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in Surface conduit with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
One light/Fan/Exhaust fan point controlled by one switch
One light point controlled by two way switches
One bell/buzzer point controlled by one push button on the same board with other switches or independent
One 5 pin 5 Amp switch socket out let point on the same board with other switches
One 5 pin 5 Amp switch socket out let point on an independent board
M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring concealed in wall/false ceiling with pressed steel concealed Sunken boxes suitable for Modular Switch & Socket not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
One light/Fan/Exhaust fan point controlled by one switch
One light point controlled by two way switches
One bell/buzzer point controlled by one push button on the same board with other switches or independent
One 5 pin 5 Amp switch socket out let point on the same board with other switches
One 5 pin 5 Amp switch socket out let point on an independent board
M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in existing conduit with pressed steel concealed Sunken boxes suitable for Modular Switch & Socket not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
One light/Fan/Exhaust fan point controlled by one switch
One light point controlled by two way switches
One bell/buzzer point controlled by one push button on the same board with other switches or independent
One 5 pin 5 Amp switch socket out let point on the same board with other switches
One 5 pin 5 Amp switch socket out let point on an independent board
M&L for point wiring complete with PVC insulated and unsheathed cable 1.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in Surface conduit with pressed steel concealed Sunken boxes suitable for Modular Switch & Socket not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 1.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
One light/Fan/Exhaust fan point controlled by one switch
One light point controlled by two way switches
One bell/buzzer point controlled by one push button on the same board with other switches or independent
One 5 pin 5 Amp switch socket out let point on the same board with other switches
One 5 pin 5 Amp switch socket out let point on an independent board
M&L for point wiring complete with PVC insulated and unsheathed cable 2.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in concealed in wall/false ceiling with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 2.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
M&L for point wiring complete with PVC insulated and unsheathed cable 2.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in Existing Conduit with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 2.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed.
M&L for point wiring complete with PVC insulated and unsheathed cable 2.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in Surface Conduit with pressed steel concealed Sunken boxes not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 2.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Anchor/KEI/ Polycab ]
M&L for point wiring complete with PVC insulated and unsheathed cable 2.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring concealed in wall/false ceiling with pressed steel concealed Sunken boxes suitable for Modular Switch & Socket not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 2.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Anchor/KEI/ Polycab ]
M&L for point wiring complete with PVC insulated and unsheathed cable 2.5 sqmm (nominal area) ISI marked multi-stranded copper conductor single core including ISI marked 20mm dia 'medium grade' PVC conduit for point wiring in Existing Conduit with pressed steel concealed Sunken boxes suitable for Modular Switch & Socket not less than 1.6mm thick of reqd size (factory painted) and with top cover 3 mm thick of Hylam sheets of required colour, painting Sunken boxes inside and out side with one coat of red oxide primer complete including 2.5 sqmm PVC insulated and unsheathed ISI marked copper cable to common earth connected to earth dolly colour coding of cable as per IE Rule complete all as specified & directed. [ Make of cable - Finolex / Havell's / Anchor/KEI/ Polycab ]
S&F Bell switch AC, 230 Volt single pole
S&F switch piano, flush type, 5 amps single pole, one way
S&F switch piano, flush type, 16 amps single pole, one way
S&F socket, flush type, 5 pin, 16 amp multi purpose.
S&F socket 2 in 1, 3 pin, 5 and 5 Amps flush type
S&F switch piano Two way flush type, 05 amps single pole, one way
S&F modular switch , 6 Amp singe pole one way.
S&F modular socket 2/3 pin, 6 amp multipurpose.
S&F modular switch , 16 Amp, single pole one way.
S&F modular socket multipurpose 16 amps.
S&F modular switch , 6 Amp Bell Push singe pole one way.
S&F modular Two Way switch , 6 Amp singe pole one way. Note : -( For Ser. Item No 64-76) The rate will be inclusuve of suitable cover,and module frame for group of switches,sockets etc all as required as per site requirement.
Supply and fix in repair Modular fan regulator complete all as specified and as directed.
S&F in repair ceiling rose 3 phase /PVC/polycarbonate,isolated body .
Taking down carefully aluminum/copper point wiring (light/ fan/socket or power) complete ,including fixture and fittings such as switches,ceiling roses,pendants ,reguators socket,light fitting etc removing materials to store for keeping in safe custody or for taking credit( credit for above items should be made as per conditions separtely) and making good disturbed surfaces of walls,floors etc.
M&L in repair Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface concealed PVC conduit, heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed. Make of conductor : Havells/polycab/KEI Note: Two runs each of 4.00 sqmm main cable and one RM of 4.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
M&L in repair Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 6.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface existing conduit, heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed. Make of conductor : Havells/polycab/KEI Note: Two runs each of 6.00 sqmm main cable and one RM of 6 .00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
M&L Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 10.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid SurfacePVC conduit ISI Marked , heavey duty and connected to main board and making good disturbed surface complete all as specified and as directed. Make of conductor : Havells/polycab/KEI Note: Two runs each of 10.00 sqmm cable and one RM of10.00sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose.
M&L in repair Sheet metal enclosures for DBs SPN 2 way flush mounted including accessories therein and disposing off complete all as specified and directed. Make:Legrand/HAVELLS / indoasian
M&L in repair Sheet metal enclosures for DBs SPN 4 way flush mounted including accessories therein and disposing off complete all as specified and directed. Make:Legrand/HAVELLS / indoasian
M&L in repair of sheet metal enclosures double door for DBs SPN 12 way 240 Volt with 200 Amps rated Busbar including accessories therein and disposing off complete all as specified and directed.(Make: Indoasian or its equivalent/legrand /CG )
M&L in repair Sheet metal enclosures for DBs SPN 8 way with 200Amps rated busbar including accessories therein and disposing off complete all as specified and directed. Make:Legrand/HAVELLS / indoasian
M&L in repair of MCB SPN 63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed. .(Make: Indoasian or its equivalent/legrand /CG )
M&L in repair MCB SPN 40 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed. Make of Legrand or equavalent to HAVELLS / SIEMENS/indoasian
M&L in repair MCB SP 32 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed. Make: of Legrand or equavalent to HAVELLS / SIEMENS/indoasian
M&Lof MCB TPN 40-63 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed.(Make: Indoasian or its equivalent/legrand /CG )
M&Lof MCB TPN 100 Amps, 240 Volts, having breaking capacity 10 kA, 'C' characterstic complete all as specified and as directed.(Make: Indoasian or its equivalent/legrand /CG )
S&F Recess mounting type fitting LED indoor luminaire powder coated, CRCA or powder coated aluminium panel 2' x 2' (Appx) system wattage 36 watt (cool white), minimum system lumen efficacy not less than 80 % , CRI not less than 80, colour temperature not less than 6000 K, power factor not less than 0.95, LED driver with constant output voltage and current at input voltage of 140volt to 285 volt AC, 50 HZ, Surge Protection>2 KV, IP protection IP 20, powder coated housing with ashthetic bottom frame, with excellent heat dissipation through high thermal conductivity, high efficiency transulence diffuser, suitable for any type of ceiling system including connection with PVC insulated copper conductor 3 core cable of 0.50 sqmm complete all as specified. (Make Havells/Bajaj/CG or Equivalent.)
Supply and fixing in repars of steped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. As per existing make requied complete all as specified and as directed.
Supply and fix in repairs LED lights fitting Four feet 1 x 20 Watt LED 6500K, 220V,AC decorative ultra slim square profile LED lighting fixture with extruded polycarbonate environmental friendly energy, with driver, holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.Make :Bajaj/wipro/Havells /Orient/philips
M&L in repair of Lamp holder, insulated body, cord grip pattern SP 230 volt, including taking down complete all as specified and as directed.
Supply and fixing in repar of LED 9/ 10 watt Bulb thruded type warm complete all as speciefed and as directed.
Supply and fixing in repar of LED 9/ 10 watt Bulb holder type white complete all as speciefed and as directed.
Supply and fixing in repar of LED light fitting Bulk Head type with high out put diffuser 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge Make Havells/philips/bajaj/wipro
Supply and fixing in repar of LED light fitting 2 feet 10 watt 220 V AC decorative type with driver holder and including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge Make Havells/philips/bajaj/wipro
Supply and in repair round type light fitting 9/10 Watt 230 V AC outdoor type complete with driver, lamp fixing of wall,ceiling with impact and corrosion resistant as per existing model fitting complete all as specified and as directed.
Supply and in repair round type light fitting 2/3 Watt 230 V AC outdoor type complete with driver, lamp fixing of wall,ceiling with impact and corrosion resistant as per existing model fitting complete all as specified and as directed.
Supply and fixing in repair of LED rod 20 watt NU Batten 2000 lumeen in a compact batten (61.8 cm) decorative LED Fixture with curved diffuser and extunded polycarbonate channel envernoment friendly energy efficent complete all as specified and directed by Engr-in-Charge Make : CG ,Havells/philips/bajaj/wipro/surya
Supply and fixing in repair of flourocent 4 pin rod 36 watt lumeen 29002G11 complete all as specified and directed by Engr-in-Charge Make : CG ,Havells/philips/bajaj/wipro
Supply and fix in repair of 15 Amps switch socket combination including Box complete all as specifed and as directd
Supply and fix in repair of 5 Amps switch complete all as specifed and as directd
Supply and fix in repair of 5 Amps socket complete all as specifed and as directd
M&L in repair of VTPN Vertical three phase distribution board, VTPN, 4 way 440 volts having IP-54 isolated busbar assembly IK 09 Mechnical impact strength door earthing protection, double door with provision for fixing of MCCBs as incomer up to 125 Amps and MCBs as outgoing complete all as specified and as directed .(Make: Indoasian or its equivalent/legrand /CG )
Supply and fix in repairs of MCCB 3P 25 to 100 Amps /415Volts ,having breaking capacity with complete accessories as per existing suitable size complete all as specified and as directed
Supply and fix in repairs of MCCB 3P 160 Amps /415Volts ,having breaking capacity with Complete accessories as per existing suitable size complete all as specified and as directed
Supply and fix in repairs of MCCB 4P 63 Amps /415Volts ,having breaking capacity with complete accessories as per existing suitable size complete all as specified and as directed
Supply and fix in repairs of MCCB 4P 100 Amps /415Volts ,having breaking capacity with Complete accessories as per existing suitable size complete all as specified and as directed
Supply and fix in repairs of MCCB 4P 160 Amps /415Volts ,having breaking capacity with Complete accessories as per existing suitable size complete all as specified and as directed
Supply and fixing of PVC Casing caping 16/20 mm complete all as specifed and as directed
Supply and fixing of PVC Flexible pipe 15/20 mm complete all as specifed and as directed
Supply laying, connecting and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, of size 10 sqmm 4.0 core laind in trenches or passing through pips/ ducts including taking down complete all as specified and directed by Engineer in charge
Supply laying, connecting and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, of size 25 sqmm 3.5 core laind in trenches or passing through pips/ ducts including taking down complete all as specified and directed by Engineer in charge
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for laying of cable and foundation of poles, stays and getting out in any type of soil, all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and as directed by Engineer-in-Charge.
Removing surplus excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete, all as specified and as directed by Engineer-in-Charge.
M & L for Sand cushioning to underground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. by Engineer-in-Charge. Note: Punned thickness of sand shall be measured.
M&LCommon burnt sub class ‘B’ brick laid flat in trenches over and across the length of cable with length of brick perpendicular to the direction of cable adjacent/abutting each other complete all as specified and directed for cable protection.
MAHAJAN TRADING CO
ANIKET TRADERS
DAVINDER SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .