Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
10 Feb 2020, 6:00 pmClosed
GE AF Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati-15, Assam, Pin- 781015 Tele 0361 - 2840127
8717/BOR/E8 Repair/maint of old electrical wiring and replacement of unserviceable conventional fittings/fixture with led fittings/fixture at MT hanger certain technical building blast pen termac disposal and high mast light at 19 wing AF under GE
2019_MES_300327_3
8717/BOR/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
GE AF Borjhar
As per NIT/Tender documents
7 documents required · 7 mandatory
₹500
GE AF Borjhar
₹50,000
Yes
20 Feb 2020
15 Jan 2020
11 Feb 2020
15 Jan 2020
10 Feb 2020
25 Jan 2020
16 Jan 2020 - 25 Jan 2020
Amount
Taking down carefully aluminum/copper point wiring (light, fan socket or power) complete (fittings & fixtures such as switches, ceiling roses, pendants, regulators, sockets etc to be maesured separately) and making good disturbed surfaces of walls, floors etc complete all as required and removing materials to store for keeping in safe custody for reuse in the work as directed.
Dismantling/taking down of unserviceable dispersal light/ tarmac / tower light of any wattage, any make, any size of HPSV fitting/MH fitting and removing from site for fixing new fittings in its position complete all as specified and directed by Engineer-in-Charge.
Taking down carefully defective High mast light of any make & size, HPSV/MH, Flood light fitting removing from site, all as directed and S&F new LED Flood light fittings in original position by employing specialist person having thorough knowledge in high mast light, complete, all as specified and directed by Engineer-in-Charge. Note:- New LED flood light & relevant accessories shall be measured & paid seperately as supply only under item No.19 after taking down high mast light fitting.
M&L for Point wiring complete with 2.5 Sq mm (nominal area) PVC insulated, unsheathed and multi stranded copper conductor FRLS cable (ISI marked), 1100 volt, drawn into and including stove enamelled mild steel conduit and conduit fittings including PVC insulated 2.5 Sq mm single core multi stranded copper conductor FRLS cable for earth wire to common earth and connecting to earth dolly including factory made metal sheet terminal box modular flush type of thickness not less than 3.00mm (required as per site condition) for mounting fittings such as switches, sockets, fan regulators, bell push etc including machine made brass screw and washers etc for one light point controlled by one switch 5Amp complete all as specified and as directed by Engineer-in -charge. Note:-(i) Colour code shall be provided for point wiring as per IE rule for phase like as Red/Yellow / Blue / Black / Green. (iii) Making good to existing disturbed portion of existing surfaces shall be done by the contractor and match with existing surfaces at own cost. Nothing extra shall be entertained on this account. (iv) Switch & socket shall be measured & paid separately under concerned item.
All as per item No 4.00 above but fixing only
M&L for PVC insulated sheathed copper conductor cable 2.5 sqmm three core for connection security light from overhead conductor complete all as specified and directed by Engineer-in-Charge.
M&L for PVC insulated sheathed alluminium conductor cable 10 sqmm twin core complete all as specified and directed by Engineer-in-Charge.
M&L for PVC insulated sheathed alluminium conductor cable 6 sqmm twin core complete all as specified and directed by Engineer-in-Charge.
M&L for PVC insulated sheathed alluminium conductor cable 4 sqmm twin core complete all as specified and directed by Engineer-in-Charge.
S&F bracket for street light fittings of any size made out of GI pipe light grade 40mm dia 2 mtr length bend to required size and shape including provision of clamps and one 15 mm dia pipe support of requird length and fittings in position and including two coat of aluminum paint over a coat of red oxide primer with and including taking down old bracket complete all as specified and directed.
S&F 'CPRI certified 30W LED Flame proof Bulkhead / Well glass Luminaire recommended for Gas / Vapor Group of IIA & IIB and Zone 1 & 2 made out from die cast aluminum housing with heat resistant toughened glass IP65 protection complete of capacity 30W complete all as specified and directed by Engineer-in-Charge. Make :- Crompton Cat No. FWL1315-30-CDL or Equivalent make from Philips/Surya/Havells
S&F 'LED highbay circular light 120Wwith best lightening techonology luminair, comes in different beam angle suitabl for different modern hi-tech industrial application and werehouse application with better vertical illumination complete of 120 W capacity complete all as specified and directed. Make:- Baja Cat No.BGHB 120W LED GIV or equivalent from Phillips / CGL/Surya/Havells
S&F 'LED highbay circular light 150W with best lightening techonology luminair, comes in different beam angle suitabl for different modern hi-tech industrial application and werehouse application with better vertical illumination complete of 120 W capacity complete all as specified and directed. Make:- Baja Cat No. BGHB 150W LED GIV or equivalent from Phillips / CGL/Havells
S&F 'circuler 70' LED Flood light with tapered fin designe and execllent magagement along with IP 66 proctection complete of 70 W capacity complete all as specified and directed. Make:- Crompoton Cat No. LFLN11-L/60 or equivalent from Phillips / Havells/Jaguar
S&F ' LED high bay light Luminaire with high pressure die cast housing high efficiency with futuristic luminaires with cutting edge technology & design IP65 protection complete of 80W capacity complete all as specified and directed. Make:- Bajaj Cat No.BGPPH 80W LED or equivalent from Phillips / CGL/Havells/Jaguar
S&F 'LED HIGHBAY LUMINIARE' LED high bay light Luminaire with high pressure die cast housing high efficiency with futuristic luminaires with cutting edge technology & design IP65 protection complete of 100W capacity complete all as specified and directed. Make:- Bajaj Cat No. BGPPH 100W LED or equivalent from Phillips / CGL/Havells/Jaguar
S&F 'Turbo LED' Flood light Luminaire with secondary optics made in high pressure extrusion housing of heat sink with IP66 protection complete of 160 W capacity complete all as specified and directed. Make:- Bajaj Code. BARFEG 160W LED or equivalent from Havells / CGL/Philips/Surya/Jaguar
Supply and fix 'Turbo LED' Flood light Luminaire with secondary optics made in high pressure extrusion housing of heat sink with IP66 protection complete of 120 W capacity complete all as specified and directed. Make:- Bajaj Code. BARFEG 120W LED or equivalent from Havells / CGL/Havells/Jaguar
Supply only 'Turbo LED' Flood light Luminaire with secondary optics made in high pressure extrusion housing fof heat sink with IP66 protection complete of 180 W capacity complete all as specified and directed. Make:- Bajaj Code-BARFEG 180W LED or equivalent from Havells / CGL/Jaguar
Taking down of old unserviceable aviation light from tower, blast pen and Hanger complete all as directed.
S&F Solar avation obstruction light base on LED technology intebcity less then 10 CD (Flashing), Horizontal divergence 360 Degree, flash setting 20-60 times/min (user-adjustable), on off level 70/100 lux, internal battery capacity 3.6/10 AH (maintenance-free), IP protection IP 65, visible distance less then 3.6 KM, base material dia casting aluminium LM6 and lamp houshing polycarbonate with UV resistance and bird spike complete fixing arrangement of like base plate as top fixing or side fixing with brass nut and bolts, complete all as specified and directed. Make :- Micolux or Equivalent MES approved make.
S&F Rubber insulation tap 25cm width 2.5 Mtr long fixing of connection make water proof outside the fittings and also fixing underground cable where crack arises outside the buildings complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and paving n.exc 15cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-charge
S&F in repair for aluminium cable lugs for fixing of armoured cables in panels for 16 Sqmm cables complete all as specified and directed.
All as per item No 24.00 above but for 25 Sqmm cable
All as per item No 24.00 above but for 35 Sqmm cable
All as per item No 24.00 above but for 50 Sqmm cable
All as per item No 24.00 above but for 70 Sqmm cable
All as per item No 24.00 above but for 95 Sqmm cable
All as per item No 24.00 above but for 120 Sqmm cable
All as per item No 24.00 above but for 150 Sqmm cable
All as per item No 24.00 above but for 185 Sqmm cable
S&F in repair for copper cable lugs for fixing of armoured cables in panels for 10 Sqmm cables complete all as specified and directed.
All as per item No 33.00 above but for 16 Sqmm cable
All as per item No 33.00 above but for 25 Sqmm cable
M&L for PCC (1:2:4) type B-1, using 20mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
M&L for PCC (1:3:6) type C-1, using 20 mm graded stone aggregate as in coping/collar for poles including necessary form work and finished to exposed surface even and fair without using extra cement all as specified and as directed by Engineer-in-charge
Taking down of MCCB of any size complete all as specified and directed.
S&F MCCB 100 Amps, TPN/ 4 pole, 415 volt, breaking capacity 25 KA, ICS=100% ICU adjustable type, O/L 0.8-1.0, adjustable S/C 5-10 ln, conforming to IS, complete, all as specified and directed.
S&F MCCB 63 Amps, TPN/ 4 pole, 415 volt, breaking capacity 25 KA, ICS=100% ICU adjustable type, O/L 0.8-1.0, adjustable S/C 5-10 ln, conforming to IS, complete, all as specified and directed.
Taking down of unsrviceable feeder piller box of different size complete all as specified.
Supply, installation, testing and commissioning LT Feeder pillar box Factory made of size 400 (w) x 600(H) x 300 mm (B) suitable for 3 phase 415 Volts CPRI approved out door suitable size single/double door made out of 3.15mm thick CRCA sheet with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 63 Amp and including PCC foundation as per site requairment to accomodated to the following. INCOMING : (a) MCCB 4 pole 63 Amp 25 KA - 01 No. (b) LED indicating lamp R-Y-B - 03 Nos. OUTGOING (a) MCB SPN 32 Amps -02 Nos (b) MCB SPN 25 Amps-02 Nos (c ) MCB SPN 15 Amps -02 Nos (d) Single phase timer with contator
Repair/ Maintenance LT feeder pillar box of CPRI Tested of Size 800X600X500mm suitable for 3 phase 415 Volts out door type double door made out 3.15mm thick CRCA sheet with angle iron frame of size 50x50x6mm cubical type complete with aluminium bus bar 400 Amp and including PCC foundation as per site requairment to accomodated to the following :- INCOMING (a) MCCB 4 pole 125 Amp 16 KA - 01 No. (b) LED indicating lamp R-Y-B - 03 Nos. OUTGOING (a) MCCB TPN 32 Amps -02Nos (b) MCCB TPN 63 Amps br V Cap 25 KA (c ) MCCB 40 Amps -02 Nos (d) C/O switch 125 Amps TPN (e) R-Y-B LED indication lamp (f) Voltmeter of rating 0- 500 V (g) Ammeter of rating 0-100 A (h) Timmer with contractor
S&F of new digital ammeter 0-300Amps rating including necessary fabrication required and painting the effected area with existing paint including taking down of old unserviceable ammeter and complete all as directed.
Taking down of unserviciable old UG Cable of any size and as directed
Supply, laying, jointing and testing XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade, laid in trenches / duct with shaddling / on pole including all necessary fixing arrangement such as lugs, glands end termination etc of cross sectional area 16 Sqmm 4 core, complete, all as specified and directed by Engr-in-Charge.
All as per item No.46.00 herein before but of size 25 Sqmm x 4 core complete all as specified and as directed.
All as per item No.46.00 herein before but of size 35 Sqmm x3.5 core complete all as specified and as directed.
All as per item No.46.00 herein before but of size 50 Sqmm x3.5 core complete all as specified and as directed.
All as per item No.46.00 herein before but of size 70 Sqmm x3.5 core complete all as specified and as directed.
All as per item No.46.00 herein before but of size 95 Sqmm x3.5 core complete all as specified and as directed.
All as per item No.46.00 herein before but of size 120 Sqmm x3.5 core complete all as specified and as directed.
Relaying, jointing and testing old XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade, laid in trenches / duct / on pole including all necessary fizing arrangement such as lugs, glands end termination etc of cross sectional area 16 Sqmm 4 core to 25 sq mm 4 core complete all as specified and as directed. Note:- Serviceable cable retrieved from Srl item No.46.00 above shall be used for relaying.
All as per item No. 53.00 herein before but of size 50 Sqmm x 3.5 core to 70 sq mm 3.5 core
All as per item No. 53.00 herein before but of size 95 to 120 Sqmm x 3.5 core.
S&F of new digital Voltmeter 0-500 Volts rating including necessary fabrication requaired and painting the effected area with existing paint including taking down of old unserviceable Voltmeter complete all as directed.
S&F in repairs cable jointing kit for 1100 Volt grade cable for Straight through, heat shrinkable type joint, complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 16 to 50 Sqmm 3.5 core, complete all as specified and as directed by Engineer-in -charge.
S&F in repairs cable jointing kit for 1100 Volt grade cable for Straight through, heat shrinkable type joint, complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 70 to 120 Sqmm 3.5 core, complete all as specified and directed by Engineer-in -charge.
S&F in repairs cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armoured aluminium conductor cable of size 150-300 Sqmm 3.5 core, complete all as specified and directed by Engineer-in -charge
Taking down and Re-routing dicipline the serviciable power cable in hanger/ office of size 50 to 150 Sq mm with shaddleing with aluminium pati with required size of screw inside cable duct / wall, complete all as directed.
Supply anf fixing new LT UG Cable gland of size 16-50 including taking down of old unserviceable cable gland complete all as directed.
Supply anf fixing new LT UG Cable gland of size 70-120 including taking down of old unserviceable cable gland complete all as directed.
Supply anf fixing new LT UG Cable gland of size 120 -185 including taking down of old unserviceable cable gland complete all as directed.
M&L for 40 mm bore mild steel galvanised iron pipe, light grade laid in trenches or fixed to wall/along the pole for protection of cable as in repair complete all as specified and as directed.
All as per above item No 65.00 here-in-before but size 50 mm bore
All as per above item No 65.00 here-in-before but size 80 mm bore
Horizontal Boring under road and foot path for crossing 40 mm bore GI tubing for drawing UG cable, complete all as per specified and directed.
All as per above item No. 68.00 here-in-before but size 50 mm bore
Boring under road and foot path for crossing 80 mm bore GI tubing for drawing UG cable, complete all as per specified and directed.
S&F IP 66/67 thermoplastic-polycarbonate cable junction box of size 155X210X92mm with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of Two nos of GI calmp of size 25X3mm complete as in repair complete all as specified and directed.
S&F single GI pole structure of dia 100 mm dia medium grade and 1.75 meter height with welding of GI strip of size 500X 50X 6 mm in top of GI Pipe with 4 Nos of hole, two nos of GI Strip welded cross at bottom of pipe of size 300X50X6 mm, one welding of GI strip of size 300 X 50X 6 mm middle of pipe with 4 nos of hole including all earth work , PCC foundation, PCC copping of size 450X450X450mm, PCC (1:3:6) all around 1.0 meter inclding hard core including taking down of old GI Clamp of dispersal light cage complete all as specified and directed.
Excavation in trenches any type of soil (soft/loose) not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, pipe, laying of cable etc not exc 10 Sqmtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick each layers complete all as specified and as directed by Engineer-in-Charge.
Removal of surplus spoil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.by Engineer –in-charge.
M&L fine sand (River sand) spread in trenches for cushioning of cable 8 cm thick under the cable and 15cm over the cable, punned down gently to 18cm for protection complete all as specified and as directed.by Engineer–in-charge. Note :- Compacted thickness shall be measured and paid
M&L for brick protection with sub-class ‘B’ bricks laid dry flat (23 cm width) cross the cable for protection to cable after sand cushioning complete all as directed by Engineer-in-Charge.
Re-laying only old PCC cable cover in trenches for Under Ground cable protection (Serviceable Materials obtained fron item No. 45 here-in-before), complete all as specified and directed.
Taking Down of old unserviceable earthing complete all as directed by Engineer-in-Charge.
M&L for Earthing complete with copper earth plate electrode 60 cm x 60 cm x 6.3 mm thick, buried directly in ground earth pit not less than 2.25 metre below normal groud level with top edge of the plate not less than 1.5 mtr below ground level, connected to and including copper earth strip 20 x 3.00mm by means of copper brazing and steel bolts, nuts, check nuts and washers protected with 40mm bore GI pipe light grade and 15 mm dia GI pipe for watering and earth pit surrounded by picked layer of coal and common salt, 15cm thick all around bottom and top, watering pipe of 20 mm bore of light grade with funnel all as shown in electrical plate No 3 of SSR Part-I (2009) and connecting to earthing test point, main switch board and testing on completion including PCC (1:3:6) type C-2, using 20mm graded stone aggregate as in earthing pit with RCC cover and framing including necessary earth work etc, complete all as specified. Note: Resistance value should be less than 05 Ohm.
M&L for Earthing complete withgalvanised earth plate electrode 60 cm x 60 cm x 6.3 mm thick, buried directly in ground(earth pit not less than 2.25 metre below normal groud level) with top edge of the plate not less than 1.5 mtr below ground level, connected to and including galvanised iron earth strip 32x 6mm thick by means of steel bolts, nuts, check nuts and washers and earth copper strip protected with 40 mm bore GI pipe light grade and earth pit surrounded by picked layer of coal dust and common salt, 15cm thick all around bottom and top, watering pipe of 20 mm bore of light grade with funnel all as shown in electrical plate No3 of SSR Part-I (2009) and connecting to earthing test point, main switch board and testing on completion including PCC (1:3:6) type C-2, using 20mm graded stone aggregate as in earthing pit with RCC cover and framing including necessary earth work etc, complete all as specified.
Taking down Earth pit cover of conventional earthing and S&F PCC earthing pit of outer size 600x600x300 mm and RCC pit cover of size 600x600x80mm with 12mm dia plain sheet route bar including GI funnel and necessary earth work, complete, all as directed.
Taking down LT panel board and shifting of LT panel board within 100 mtr distance including necessary electric connection & testing, complete all as directed.
Taking down old unserviceable aluminium sub main wiring any size complete with PVC conduit/ casing capping and removing materials from site and making good disturbed surfaces of walls, etc complete as specified and directed.
S&F Sub main wiring with 2 runs of single core, 4 Sqmm PVC insulated, unsheathed, 1100 volts grade multi-stranded, copper conductor cables (FRLS quality) drawn through PVC casing capping / Conduit with fitting/accessories, fixed on roof, walls, ceiling of Hanger / Balst pen etc including 4.00 Sqmm PVC insulated, unsheathed, single core, multistranded,, copper conductor as earth continuity wire complete as specified and directed.
All as per item 85.00 but size 6 sqmm
Taking down of old serviceable copper/ G I strips from Blast pen/ Hanger and Refixing with new insulator with nut bolt washer including aluminium clamp of size 25X3mm suitable for blast pen/ Hanger piller for fixing of sub main wiring conduit shaddle complete all as directed.
Taking down of old unserviceable clamp and S&F aluminium clamp of size 25X3mm suitable for blastpen/ Hanger piller for fixing of sub main wiring conduit shaddle complete all as directed.
Supply and fixing test point terminal block made of gun metal or phosphorous bronze, size 75mm x 75mm x 25 mm thick, drilled and screwed including 3 Nos. 8 mm dia. 25 mm long hexagonal head screws, including MS box 2 mm thick of suitable size for protection of test point terminal, including dismantling of old unserviceable test point complete all as specified and directed.
Supply and fixing in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 25 mm x 4 mm thick, galvanised iron strip using porcelain clit/post insulators, complete all as specified and directed.
Supply and fixing in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 20 mm x 3 mm thick, copper strip using porcelain clit/post insulators, complete all as specified and directed.
S&F of vertical type of MCCB DB TPN 4 way IP-43 made of sheet steel phosphatised, powder painted with bus bar, neutral link, earth bar and Din rail, 415 Volts with double door including taking down of old DBs complete as specified and directed.Make : Legrand Cat part No 507750 or Equivalent from other specified make in PS.
Supply, fixing, connection and testing MCCB 3 Pole, 415Volts breaking capacity 25 KA,"C" series of rating 63 Amps as in repair complete as specified and directed.
Supply, fixing, connection and testing MCCB 3 Pole, 415Volts breaking capacity 25 KA,"C" series of rating 100 Amps as in repair complete as specified and directed. Make : Legrand Cat part No 4202 15 or Equivalent from other specified make in PS.
M & L for switch flame proof rotary type with termination box in LM6, 16A, single pole 250V as in repair complete all as directed
S&F of MCB SPN DB 8 way IP-43 made of sheet steel phos phatised, powder painted with bus bar, neutral link, earth bar and Din rail ,230 Volts with double door including taking down of old DBs complete as specified and directed. Make : Legrand Cat part No 5076 11 or Equivalent from other specified make in PS.
S & F Solar LED 4 watt garden light suitable for High effiency mono-crystalline soalr panel 1.6 Wp high quality LED 120 Lumen/W with 100 Lumen Lithium battery : A graded Li-ion battery No 18650 of 100 Lumen at mode 1 and 50 Lumen at Mode 2 Make: Havells /Bajaj
S&F and testing MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32 Amps as in repair complete as specified and directed.
S&F and testing MCB TPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 63 Amps as in repair complete as specified and directed.
S&F and testing MCB SP 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32 Amps as in repair complete as specified and directed.
S&F Double drum wrench gear pully with chain link between motor and drum suitable for 13 Mtr high mast pole mounted inside the pole and fixing with GI wire complete all as specified and directed .
Taking down motor of capacity 01 HP with gear pully from high mast pole and refixing after service of motor complete all as specified and directed .
S&F of GI wire of size 8 mm dia suitable for 13Mtr high mast pole mounted inside the pole complete all as directed .
S&F of GI wire clamp suitable for 13 Mtr high mast pole mounted inside the pole complete all as directed .
S&F of changing of spare parts of control panel out door type suitable size for 13 Mtr high mast pole of 8X 800 Watt capacity including one starter for UP and Down all electrical arrangement, auto / manual ON Off arrengement and one MCB TPN 32 Ampa and rewaring complete panel of suitable colure coading multistrand copper conductorof size 6.00 Sq mm testing after all arrangement complete all as directed.
RIPAN BARUAH
M/s Torrent Inc
Purbanchal Construction Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .