Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹52.0 LAccepted-AOC C 109 POCKET C SECTOR 2 DSIIDC INDUSTRIAL AREA BAWANA DELHI DELHI 110039 UDYAM DL 06 0004527 | NORTH DELHI | DELHI | 110039 | ₹52.0 L | L1 | Accepted-AOC LOA issued |
| 2 | L2₹52.3 LRejected-Finance | ₹52.3 L | L2 | Rejected-Finance L2 |
| 3 | L3₹52.6 LRejected-Finance 108 AND 111 COMMERCIAL ROAD 133001 | AMBALA | HARYANA | 133001 | ₹52.6 L | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | Instruments and Equipment Co L3 | AAR KEY INDUSTRIES L1 | H S Enterprises L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing and Commissioning of 30 KVA High Frequency IGBT based Emergency Rescue Device having following specifications. AC Input – 340–460 Volts AC Three Phase, DC Input – 360 Volts DC, AC Output – 400 Volts AC Three Phase, Sine wave, Stability – ±1%, Cooling – Forced Air Cooled, Frequency – 50 Hz ±0.5 Hz Total Harmonic Distortion – Less than 2% on linear load, Overall Efficiency – More than 90%, Power Factor – 0.8, Manual By Pass – Provided, Input / Output termination – Provided Switching Frequency – 10 kHz, kW Rating – Shall be 0.7 times the kVA Rating, IP Rating – IP 20, Overload – The system shall withstand 10% overload for one minute, Protection – Over voltage, short circuit and overload at output terminal,Low battery and high battery cut-off, Indicators – Mains, battery charging, UPS ON, output overload, battery low and UPS trip, Digital Meter shall be provided for – Input AC Voltage, Output AC Voltage, Current and Frequency,Battery Voltage and charging Current.Isolation Transformer – Built-in isolation transformer at inverter output shall be provided. AC Input MCCB – A suitable rating TP MCCB shall be provided at the mains input. DC Circuit Breaker – Suitable rating DC MCCB shall be provided at the battery input., Regenerative Power – ERD shall be equipped to handle regenerative power of the lift motor. The entire assembly shall be housed in a sheet steel enclosure duly powder coated and mounted on unidirectional castor wheels for easy movement of the equipment. Lead Acid SMF VRLA Battery Bank consisting of 12V, 42 AH, 30 Nos. batteries Make: EXIDE / Amron/ Luminous Matching cabinet / open rack to house 30 Nos. 12V, 42 AH SMF batteries complete with battery interlinks for 40 kVA ERD. MCCB – 125 Amps, Four Pole, with enclosure (1 No.) Cable – 16 sq.mm, 4-core copper wire (20 meters) complete in all respect upto the entire satisfaction of Engineer-in-charge of the work Make Hi-Shine/ Aar-key/ IECO | 3 | Each | 8,95,000 ₹26.9 L | 8,85,000 ₹26.6 L | 8,90,000 ₹26.7 L |
| 2.00 | Supply, Installation, Testing and Commissioning of 60 KVA High Frequency IGBT based Emergency Rescue Device having following specifications. AC Input – 340–460 Volts AC Three Phase, DC Input – 360 Volts DC, AC Output – 400 Volts AC Three Phase, Sine wave, Stability – ±1%, Cooling – Forced Air Cooled, Frequency – 50 Hz ±0.5 Hz Total Harmonic Distortion – Less than 2% on linear load, Overall Efficiency – More than 90%, Power Factor – 0.8, Manual By Pass – Provided, Input / Output termination – Provided Switching Frequency – 10 kHz, kW Rating – Shall be 0.7 times the kVA Rating, IP Rating – IP 20, Overload – The system shall withstand 10% overload for one minute, Protection – Over voltage, short circuit and overload at output terminal,Low battery and high battery cut-off, Indicators – Mains, battery charging, UPS ON, output overload, battery low and UPS trip, Digital Meter shall be provided for – Input AC Voltage, Output AC Voltage, Current and Frequency,Battery Voltage and charging Current.Isolation Transformer – Built-in isolation transformer at inverter output shall be provided. AC Input MCCB – A suitable rating TP MCCB shall be provided at the mains input. DC Circuit Breaker – Suitable rating DC MCCB shall be provided at the battery input., Regenerative Power – ERD shall be equipped to handle regenerative power of the lift motor. The entire assembly shall be housed in a sheet steel enclosure duly powder coated and mounted on unidirectional castor wheels for easy movement of the equipment. Lead Acid SMF VRLA Battery Bank consisting of 12V, 65 AH, 30 Nos. batteries Make: EXIDE / Amron/ Luminous Matching cabinet / open rack to house 30 Nos. 12V, 65 AH SMF batteries complete with battery interlinks for 60 kVA ERD. MCCB – 200 Amps, Four Pole, with enclosure (1 No.) Cable – 16 sq.mm, 4-core copper wire (20 meters) complete in all respect upto the entire satisfaction of Engineer-in-charge of the work Make Hi-Shine/ Aar-key/ IECO | 2 | Each | 12,89,000 ₹25.8 L | 12,75,000 ₹25.5 L | 12,80,000 ₹25.6 L |
Tender Value
₹50.9 L
EMD Value
₹1.0 L
Closing Date
17 Jan 2026, 4:00 pmClosed
VISHWNATH KHICHI
ED - Karnal
Const. of Mother and Child Block in District Civil Hospital Distt. Panipat (Pdg. Emergency rescue device for Lifts only)
2026_HRY_495984_1
202665DD77B5 5709 42AB B25B 3B924BF130F7665BAR
Open Tender
Electrical Works
60 days
Panipat
2 documents required · 2 mandatory
₹5,000
₹1.0 L
Yes
4 Feb 2026
9 Jan 2026
19 Jan 2026
10 Jan 2026
17 Jan 2026
10 Jan 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer Electrical Division PWD B&R Br., Karnal
Name of Work: Const. of Mother and Child Block in District Civil Hospital Distt. Panipat (Pdg. Emergency rescue device for Lifts only)
DNITRs. 50.93 Lakhs
Name of the Bidder/ Bidding Firm / Company :
Sl. No. HSR Items / Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder in Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.06 MB
BOQ_574484.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid