Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC N A | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹24.1 L+₹10.3 L (74.2%)Rejected-Finance | L2 | Rejected-Finance Other then lowest bidder | |
| 3 | L3₹25.3 L+₹11.5 L (82.9%)Rejected-Finance B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L3 | Rejected-Finance Other then lowest bidder | |
| 4 | Rejected-Technical D 52 FIRST FLOOR OKHLA INDUSTRIAL AREA PHASE 1 NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | - | Rejected-Technical No, Since the firm has not uploaded scanned copy of earnest money and also physical copy of earnest money has not been received hence the bid become disqualified for opening of cover 2 as per tender condition. | |
| 5 | Rejected-Technical RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | - | Rejected-Technical No, Not enlisted in required category of work. |
Tender Value
₹30.5 L
EMD Value
₹61,040
Closing Date
3 Nov 2023, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
COMPREHENSIVE MAINTENANCE OF FIRE ALARM CUM GAS SUPRESSION SYSTEM FOR OLD NEW SERVER ROOM REPAIR MAINTENANCE OF FIRE FIGHTING EQUIPMENTS AND CONNECTED WORKS INSTALLED AT DIPAC UNDER GE U P and M DELHI CANTT 10
2023_MES_621976_1
GE(U)/PM/D-42/2023-24
Open Tender
Miscellaneous Works
Item Rate
330 days
DELHI CANTT-10
MES contractor enlisted under class D category c (vi) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and cat.
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹61,040
Yes
8 Jan 2024
6 Oct 2023
6 Nov 2023
6 Oct 2023
3 Nov 2023
20 Oct 2023
Amount
Taking down Fire extinguishers of the following capacities from it's location checking thoroughly, repair the same if any deffect is found, and taken out the parts and replacement of burnout parts like pressure guage, Squeese Grip Valve, Brass valves, Bend horn, Brass cap etc.and refilling the extingushing agent at workshop after emptying the extingushing agent where directed and place the Fire extinguisher at their original location complete all as specified and as directed by Engr-in-Charge. Note:- 1. Cost of the Extinguisher agent for refilling and transportation to workshop and back to DIPAC to be included in the quoted rate. 2. Cost of removing burntout and refixing new spares of Pressure guage, Squeese Grip Valve, Brass valves, Bend horn, Brass cap etc shall be included in the quoted rate but Cost of Material for these items shall be measured and paid seperately as 'Supply Only" items.
Fire Extinguisher Liquid type stored pressure type of capacity 9.0 Ltrs
Fire Extinguisher AFFF mechanical form stored pressure type of capacity 09 Kgs
Fire Extinguisher foam catrege type of capacity 09 Ltrs
Fire Extinguisher CO2 type of capacity 4.5 Kgs
Fire Extinguisher CO2 type of capacity 2.0 Kgs
Fire Extinguisher Water CO2 type of capacity 4.5 Kgs
Fire Extinguisher ABC Dry Powder type of capacity 1.0 Kgs
Fire Extinguisher ABC Dry Powder type of capacity 2.0 Kgs
Fire Extinguisher ABC Dry Powder type of capacity 5.0 Kgs
Fire Extinguisher Powder type gas Catridge of capacity 9.0 Kgs
Supply only Pressure Guage for any type of Fire extinguisher
Supply only Squeeze Grip Valve for Dry Powder Fire extinguisher of any capacity
Supply only Brass Valve for CO2 Fire extinguisher of any capacity
Supply only Bend Horn for CO2 Fire extinguisher of any capacity
Supply only Brass Cap for Water & Mechanical foam Fire extinguisher of any capacity
M&L for two Coats of Anti corrossive paints red colour of adequated Micron rating on galvanized surfaces including repartion of surfaces including cleaning after rust inhibited through a rocess of de-greasing, acid packing, phosp[hating and over a coat of red oxide primer after painting necessary stickering suitable for fire extinguisher typer and capacity including transportation from DIPAC to contractor's workshop and back complete all as specified and as directed by Engineer-in-Charge for the following items:- Make:- Asian Paints/Berger/Acco Paints/ Dulux
M&L for two Coats of Anti corrossive paints red colour of adequated Micron rating on galvanized surfaces including repartion of surfaces including cleaning after rust inhibited through a rocess of de-greasing, acid packing, phosp[hating and over a coat of
Fire beater
Fire Hook
Fire Bucket
Fire Shovel
Supply of new fire buckets in replacement of old rusted fire buckets of capacity 10 Ltrs including two Coats of Anti corrossive paints red colour including preparation of surfaces over a coat of red oxide primer after painting necessary stickering as directed complete all as specified and as directed .
Supply of new Fire beater in replacement of old rusted fire beater including two Coats of Anti corrossive paints red colour including preparation of surfaces over a coat of red oxide primer after painting necessary stickering as directed complete all as specified and as directed .
Supply of new Fire hook in replacement of old rusted fire hooks including two Coats of Anti corrossive paints red colour including preparation of surfaces over a coat of red oxide primer after painting necessary stickering as directed complete all as specified and as directed.
Supply of new Fire Shovel in replacement of old rusted fire shovel including two Coats of Anti corrossive paints red colour including preparation of surfaces over a coat of red oxide primer after painting necessary stickering as directed complete all as specified and as directed .
Supplying and fixing in repair of Fire Extinguisher Carbon dioxide (CO2) extinguishers consisting of welded M.S. cylindrical body, light weight squeeze lever discharge valve fitted with pressure indicating gauge with internal discharge tube, discharge nozzle suspension bracket of capacity 4.5 Kg as per IS: 2878 complete with holding accessories including taking down old unserviceable one complete all as specified & directed. Make:- Minimax/ Firex/ Newage/ Nitin/ Cease Fire
ditto- all as per item No. 12.00 above but CO2 of capacity 6 Kg. Make:- Minimax/ Firex/ Newage/ Nitin/ Cease Fire
Comprehensive maintenance of Gas based fire suppression system comprising 2X60 Kgs seamless cylinder with valves and all connected electromagnetic actuators and kit complete including MS seamless pipes as ASTMA 106-250 etc in old server room Automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. etc.and all as directed. The system comprising of following items as specified & directed . (a) Gas suppression system control panel (make Agni) - 01 No. (b) Gas Cylinder 60 Kg capacity - 02 Nos. (c) Solenoid valve - 02 Nos. (d) Smoke detectors - 12 Nos. (e) Gas Nozzle - 06 Nos. (f) Hooter - 01 No. (g) Gas abort push button - 01 No. (h) Gas release push button - 01 No. (j) SMF Battery 7AH - 02 Nos. (k) Steel hose pipe - 1 Lot. (l) Control wiring complete.
Comprehensive maintenance of Gas based fire suppression system SINOREX 1230 system comprising 2 X 90 Kgs seamless cylinder with valves and all connected electromagnetic actuators and kit complete including MS seamless pipes as ASTMA 106-250 etc in New server room Automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. etc. and all as directed. The system comprising of following items as specified & directed. (a) Gas suppression system control panel (make Ravel RE120GR) - 01 No. (b) Gas cylinder 90 kg capacity - 02 Nos. (c) Solenoid valve - 01 No. (d) Gas Nozzle - 03 Nos. (e) Hooter - 01 No. (f) Gas abort push button - 01 No. (g) Gas release push button - 01 No. (h) SMF Battery 26 AH - 02 Nos. (j) Steel hose pipe - 01 Lot. (k) Control wiring complete.
Comprehensive maintenance of microprocessor based net workable analogue adderssable type 1-2 fire alarm control panel expandable to 10 loops each loop are connected 252 analog addressable devices in one loop each loop are loaded to 90% of its full capacity including comprising hooter cum stoable red colour with 99 db sound output vesda detector for new server room. Automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and then be capable of operating the system for 2 hours during an emergency conditions as required. etc. For New server room. The system comprising of following items as specified & directed. (a) Fire alarm system control panel (make Notifier) 01 No. (b) Smoke detectors - 18 Nos. (c) Response indicator - 13 Nos. (d) Hooter - 01 No. (e) Manual call point - 01 No. (f) VESDA panel - 01 No. (g) SMF Battery 26 AH - 02 Nos. (h) Air aspirator - 01 Lot. (i) Control wiring complete.
NOTE FOR ITEM NOS. 14 to 16 :- (a) Working Hrs: Monday to friday .Timings: 0900 Hrs to 1700 Hrs for monthly preventive maintenance. (b) If there is any complaint at day/night (including sunday & holidays) contractor / Auth rep of contractor /supervisor should rectify the same within four hours,failing which a penalty @ Rs.3000/-per day shall be imposed upon the contractor. (c) Weekly preventive maintenance will be carried out by qualified thechnician should least ITI holder and approved by Engr-in-charge and with minimum three years experience in the same field. (d) Monthly inspection & testing report shall be maintained. report shall be signed by MES representative & user weekly. (e) Items required for replacement /repairs shall be supplied by the contractor & cost of minor items such as nuts,bolts screws including replacement of spare parts of control panel ICs/rectifiers/LED etc and internal wiring of control panel are deemed to be included in the quoted rate. (f) Except filling of gas NAFS-125. (Gas filling by the department after refilling of cyclinder all electrical/solinied valve connections including of testing and commissioning deemed to be included in abovequoted rates.
Supply and fixing of intelligent addressable photoelectric type optical smoke detector including taking down old unserviceable one complete all as specified and as directed along with comprising the following:- Operating Voltage : 15-27 V DC Current : 200µA Alarm Current : 1mA Smoke sensitivity : 0.5-3.5& obscuration/ foot Operating temperature : 0o C – 49o C Humidity : 0-95% RH (Non condensing) Colour : White Housing : Polycarbonate Contact clamps : Stainless Steel Indications Normal : Green LED (Blinks during scan) Alarm : Red LES (Glow steady) (Make: Edward EST Model No SIGA2-PS or equivalent of SYSTEM SENSOR/ APPOLO/ HONEYWELL / NOTIFIER)
Precision Safety Equipment Limited
New Era Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .