Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹13.9 L+₹6,062 (0.44%)Rejected-AOC | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹14.3 L+₹40,337.50 (2.90%)Rejected-AOC | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹16.2 L+₹2.3 L (16.9%)Rejected-AOC | L4 | Rejected-AOC Not Lowest | |
| 5 | L5₹16.5 L+₹2.6 L (19.0%)Rejected-AOC | L5 | Rejected-AOC Not Lowest |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
7 Oct 2020, 6:00 pmClosed
Garrison Enigneer Basoli
Garrison Engineer Basoli Pin-184152
REPAIR AND MAINTENANCEOF SECURITY LIGHTS ROAD LIGHTS SOLAR LIGHTS AND STAND BY GENERATOR SETS AT JANGLOTE UNDER GE BASOLI
2020_MES_370931_1
GE/BAS-37/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Basoli
As Per Tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer Basoli
₹36,000
Yes
Garrison Engineer Basoli
26 Oct 2020
1 Sept 2020
9 Oct 2020
1 Sept 2020
7 Oct 2020
23 Sept 2020
7 Sept 2020
Amount
Repair/rectification for street/security light/ perimeter light/ flood light any type, capacity & make to make the security/street lights in serviceable condition as intimated by JE E/M / Engineer -in- Charge after rectification/trace out the fault which includes removing of street/security light fitting from LT/HT PCC/steel tubular/swan neck poles, refixing after repair, tightening of loose connection on ACSR conductor/with bus bar chamber/in DB, replacement of ballast, lamp, ignitor, lamp holder, capacitor, replacement of glass, jumper breakage, replacement of connection wire or any other part and refixing in proper alignment on GI pipe bracket or by other means as per site requirement incl replacement of screws,nut,bollts washers as reqd, proper connection with PVC insulation tape etc complete to keep the light in serviceable condition through out the period of contract by repairing one time all as directed to the entire satisfaction of JE E/M / Engineer-in-Charge Note : (i) Worn out/ damaged/ unserviceable parts to be replaced shall be measured and paid for separately under relevent items of sch 'A' as supply only and fixing is deemed to be included under this item. (ii) All the T&P and transportation required for the work shall be arranged by the contractor which shall be deemed to be included in quoted rate. Contractor shall provide the all type of T & P i.e. tools, insulation tape, ladder any type etc to electrician for attending the complaints. The quoted rate include the cost of minor items i.e. screws, nuts, washers for light fitting etc. (iii) Contractor shall provide & maintain the register regarding 100% serviceability of security lights duly signed by the JE/Engr-in-Charge, contractor, unit rep. (iv) The work will be carried out on day to day at as per direction of JE/ Engr-in-charge. (v) The electrician shall receive the complaint from JE /Engineer -In -Charge on complaint slip and after completion of job the slip shall be deposited to JE /Engineer -In -Charge daily duly signed by users. The printed complaint slip and compliant register shall be arranged by the contractor without any extra cost. (vi) The contractor shall arrange one electrician and one helper in one shift for 0900 hrs to 1700hrs on daily basis except sunday and holidays. (vii) An inventory for the parts/spares which are found unserviceable and requir replacement with new parts/spare shall be prepared and kept in record duly signed by Engr-in-charge and contractor. (viii) In case non deployment/absence of staff from duty recovery @850/- per day for electrician and Rs. 550/- per day for helper shall be recovered from the contractor's dues. The record of presence of workmen with name and details shall be maintained with signature of JE E/M, Engr-in-Charge and contractor. The decision of accepting officer shall be final and binding.
Supply only Driver electronic compact type suitable for LED street light fitting 70 Watt as per sample/required at site complete all as specified and directed.
Supply only Driver electronic compact type suitable for LED street light fitting 90 Wattas per sample/required at site complete all as specified and directed.
Supply only Driver electronic compact type suitable for LED street light fitting 120 Wat as per sample/required at site complete all as specified and directed.
Supply only LED street light bulb thread/pin type of capacity 30 Watts complete all as specified and directed
Supply only LED street light bulb thread/pin type of capacity 40 Watts complete all as specified and directed
Supply only porcelain Lamp holder suitable for 30/40 watt LED street light bulb fitting thread type complete all as specified and directed.
Supply and fix in repair for street light bracket made to shape at required angle made out of 50mm dia ( light grade ) GI tubing of length not less than 1.2m long suitable for fixing /holding street light fittings including mild steel flate iron 50 x 6 mm clamp 02 Nos with bolts, nuts and washer complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair for 2.5 sqmm PVC insulated and sheathed cable twin core aluminium conductor cable from over head conductor to street light fittings complete all as specified and directed.
Supply and fix in repair / replacement LED street light fitting of capacity 45 Watt energy saving & environmental friendly long life versatile pressure die cast aluminium with ptotection IP66 and impact reistance of IK07 with high power LEDs as light source with electronic chip and driver (lamp type 45W LED) suitable for pole dia 54mm(max)complete with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed. Cat Part No PCGLST145N of make polycab or equivalent in CG/Bajaj/Philips.
Supply and fix in repair / replacement LED street light fitting of capacity 60 Watt energy saving & environmental friendly long life versatile pressure die cast aluminium with ptotection IP66 and impact reistance of IK07 with high power LEDs as light source with electronic chip and driver (lamp type 60W LED) suitable for pole dia 54mm(max)complete with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed. Cat Part No PCGLST160N of make polycab or equivalent in CG/Bajaj/Philips/Halonix
Supply and fix in repair / replacement LED street light fitting of capacity 35 Watt energy saving & environmental friendly long life versatile pressure die cast aluminium with ptotection IP66 with high power LEDs as light suorce with electronic chip and driver (lamp type 35W LED) suitable for pole dia 54mm(max)complete with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed. Cat Part No PCGLST135N of make polycab or equivalent in CG/Bajaj/Philips/Halonix
Supply and fix in repair / replacement flood light of capacity 80 Watt energy saving & environmental friendly long life versatile pressure die cast aluminium with ptotection IP66 made out pressure die cast aluminium housing suitable lens & tughened glass with high power LEDs as light source with electronic chip and driver of cat part No PCGLFT1028057 of make polycab or equivalent in CG/Bajaj/Philips/Halonix with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed by engr-in-charge
Supply and fix in repair / replacement flood light of capacity 60 Watt energy saving & environmental friendly long life versatile pressure die cast aluminium with ptotection IP66 made out pressure die cast aluminium housing suitable lens & tughened glass with high power LEDs as light source with electronic chip and driver of Cat Part No PCGLFT1026057of make polycab or equivalent in CG/Bajaj/Philips/Halonix complete with the provision of double driver and additional surge protector of capacity 10 kv all as specified and directed
Supply and fixing in replacement PVC conduit 25mm dia medium grade for fixing along the pole with 02 Nos clamps per pole the connections from junction box to street lights all as specified and directed.
Excavation in trenches not .exceeding 1.5m wide and not exceeding1.5m depth and getting out in any type of soil, complete all as specified and directed .
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc.25 cm complete all as specified and directed .
Removing excavated material n exc. 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified .
Material and labour for well burnt, old size Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and directed.
All as per item No 22 here-in-before but except brick complete all as specified and directed.
Material and labour for sand cushioning to under ground cable 8 cm before laying the electric cable and 15 cm after laying the cable as specified in SSR 1991 of part -I complete all as specified and directed.
Supply and erect steel tubular swaged pole type 410 SP-31 (9 meter long) complete with cast iron / MS base plate, top plate welded with MS round sheet with necessary nuts, bolts and wahsers duly painted with a coat of red oxide primer and two coat of aluminum paint including black and yellow strip 30cm in height above the coping of the pole complete all as specified and directed.
Material and labour for plain cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation & filling of pole/stay, complete all as specified and directed.
Material and labour for Continuous earth wire/guard cradle horizontal/rectangular fabricated with 4mm dia galvanized mild steel, binding wire including dismantling and taking out the damaged broken GI Earth wire in any position complete all as specified and directed .
Material and labour for Aluminium conductor, steel reinforced (ACSR) conductor of any size for OH lines including stretching, binding with aluminium binding wire, jumpers, line taps etc including dismantling and taking out the damaged broken ACSR conductor of any size from service feeder or distribution span in any position complete all as specified and directed.
Supply and Fix for shackle type, polycaronate Insulator incl one galvanised mild steel spindle, two galvanised iron washers,and one galvanised iron nut, 100 mm height, 115 mm dia ,suitable for 1100 Volt complete all as specified and directed.
Supply and Fix for structural steel work as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including , nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one priming coat of red oxide, one under coat , one finishing coat of aluminium paint and epoxy coating, complete all as specified and directed.
Supply and fix for Stay assembly complete with stay rod 20 mm dia and all accessories all as shown in electrical plate No. 1 of SSR Part-I including dismantling and taking out the damaged broken stay assembly in any position and removal for further disposal complete all as specified and directed. Note :- Excavation, earth work and PCC work shall be measured and paid separately under respective items.
Material and labour for loop insulator vitreous porcelain, white,brown or green with overall dimensions 140mm,clearance from hole 25.5 mm complete all as specified and directed .
Material and labour for galvanised stay strand of size 7/4 mm ccomplete all as specified and directed .
Supply and laying in trenches or fixing or passing through pipe UG cable XLPE insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,cross section area 50 sq mm 3.5 core complete all as specified and directed.
Supply and laying in trenches or fixing or passing through pipe UG cable XLPE insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,cross section area 25 sq mm 3.5 core complete all as specified and directed.
Supply and laying in trenches or fixing or passing through pipe UG cable XLPE insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,cross section area 16 sq mm 4.0 core complete all as specified and directed.
Supply and laying in trenches or fixing or passing through pipe UG cable XLPE insulated,armoured heavy duty electric cable with aluminum conductor,1100 Volts grade,cross section area 16 sq mm 2.0 core complete all as specified and directed.
Supply and fix for DWC high density polyethylene pipes having dia 63/50 as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laidalong pole/along wall/in PCC on GL/roof and including all fittings as required at site including taking down the old unserviceable pipe complete all as specified and directed.
Supply and fix in repair for junction box of size 300x250x150mm made out of 1.6 mm thick CRCA sheet powder coated front hinged door with openable and self closing arrangements including aluminium bus bar 3 Phase 4 wire system of size 20mm x 5mm fixed on SMC/DMC insulators and cable entry glands for connections and MCB SP 6 Amps-01 No all as required and fixed to poles with MS clamp made out of MS flat iron of size 25x5mm and including nuts, bolts and washers complete all as specified and directed.
Supply and fixing in replacement polycarbonate globe prismatic finish of size 200 mm ampore in shape in and including with holder B-22 having provision for fixing on pipe and LED lamp all as specified and directed. Make : Bajaj/CG/Philips.
Supply and fixing in replacement polycarbonate globe prismatic finish of size 250 mm imperial in shape in and including with holder B-22 having provision for fixing on pipe and LED lamp all as specified and directed. Make : Bajaj/CG/Philips/ Halonix
Supply and fixing in replacement polycarbonate globe prismatic finish of size 300 mm dia in shape in and including with holder B-22 having provision for fixing on pipe and LED lamp all as specified and directed. Make : Bajaj/CG/Philips/ Halonix
Supply and fixing in replacement polycarbonate globe prismatic finish of size 385x340 mm seattle in shape in and including with holder B-22 having provision for fixing on pipe and LED lamp all as specified and directed. Make : Bajaj/CG/Philips/Halonix
Supply and fixing in replacment of smart integrated solar street light LED with built in mono crystalline panel, litheium ferro phosphate battery MPPT charge controller and PIR Sensor with colour temperature 6000 to 6500 K capacity 12 W all in one standard complete.all as specified and directed.
Supply and fixing in replacment of smart integrated solar street light LED with built in mono crystalline panel, litheium ferro phosphate battery MPPT charge controller and PIR Sensor with colour temperature 6000 to 6500 K capacity 15 W all in one standard complete.all as specified and directed.
Supply and fix Off load change over switch four pole with sheet metal enclosure of capacity 100 Amps , 415 Volts,Ac with necessary nuts, bolts and washers including necessary electric connections complete all as specified and directed
Repair and maintenance of DG sets 82.5 KVA capacity with carry out servicing as per the OEM is manual based as hours run/ vintage of the DG set, inspecting all the parts for its further serviceability i.e air intake system, fuel system, lubricating system, cooling system and electrical system,cleaning,calibration of each parts of the system, replacement of defective parts, and fixing of serviceable parts, rectification of leakage of fuel and oil,, cleaning /replacement of all the filter elements,calibration of FIB, toping up of radiator coolent replacement of engine gasket set, replacement of engine oil, complete cleaning of out door body and inner body. Notes for Sr Item No 44 to 46 (i) New spare parts and engine oil shall be measured and paid separately under respective items. (ii) Labour charges for replacement of old engine oil and old defective spare parts shall be deemed included in quoted rates. (iii) Cost of routine lubrication/ greasing to spare parts, lubricants/grease, tightening of nut, bolts and washers etc. shall deemed included in quoted rates. (iv) Cost of fixing and transportation of all components/ spare parts required being repair, of DG sets from site to workshop for repair and workshop to site after repair shall be deemed included in quoted rates. (v) Periodical routine maintenance/ checkup of diesel generator sets shall be carried out as per TI-04 of 1984 and maintenance record, prepared/ maintained by contractor and signed by concerned JE E/M, Engineer-In-Charge and Contractor. This maintenance record shall be produce to Garrison Engineer whenever asked.
(vi) Periodical routine maintenance/ checkup of diesel generator sets shall be carried out as per following periodicity: a) Stage-I (Monthly): (i) Cleaning of air cleaner/ filter. (ii) Changing of lubricants and oil filter elements. (iii) Cleaning of fuel tanks and cleaning of fuel filter elements. (iv) Cleaning of radiator cooling fins and top up of coolant. v) Cleaning of line cylinder head fins, in case of air cooled engines. (vi) Checking of all electrical instruments/indicating or any other gauge i.e. frequency meter,voltmeter, ammeter, revolution meter, Hrs run meter, water temp gauge, fuel gauge etc for satisfactory functioning. (b) Stage-II (Quarterly): (i) Changing of engine oil, if required, and clean the pre-cleaner bowl. (ii) Check/ open radiator fins, and clean, if chocked/ blocked. (iii) Check button filter in banjo bolt of feed pump. (iv) Drain the water from water separator, if provided. (v) Check all external fasteners as per specified torques. (vi) battery lead connections. (vii) Check belt alignment and belt condition. (viii) Check turbo changer. (ix) Leakage in air take/ exhaust of exhaust piping (x) Lubrication to the turbo charger,Oil filter. (xi) Repair work shall be carried out by authorised dealer (xii) Spare parts used during repair shall be only as per the original make (xiii) After completion testing of DG Set shall be carried out on Full load test in the presence of Engineer-in-Charge (xiv) The fuel for testing shall be born by contractor and shall be deemed to include in quoted rates.
All as per srl item No 44 above but 63/62.5 KVA DG Set
All as per srl item No 44 above but 40/31.50 KVA DG sets
Supply only oil filter suitable for 82.5 KVA DG Set
Supply only fan belt suitable for 82.5 KVA DG Set
Supply only hose pipe with two Nos metallic clip suitable for 82.5 KVA DG Set
Supply only Diesel pipe(steel) with banjo connection suitable for 82.5 KVA DG Set
Supply only air filter suitable for 82.5 KVA DG Set
Supply only fuel filter suitable for 82.5 KVA DG Set
Supply only oil filter suitable for 63/62.5 KVA DG Set
Supply only fan belt suitable for 63/62.5 KVA DG Set
Supply only hose pipe with two Nos metallic clip suitable for 63/62.5 KVA DG Set
Supply only Diesel pipe(steel) with banjo connection suitable for 63/62.5 KVA DG Set
Supply only air filter suitable for 63/62.5 KVA DG Set
Supply only fuel filter suitable for 63/62.5 KVA DG Set
Supply only oil filter suitable for 40/31.50 KVA DG Set
Supply only fan belt suitable for 40/31.50 KVA DG Set
Supply only hose pipe with two Nos metallic clip suitable for 40/31.50 KVA DG Set
Supply only Diesel pipe(steel) with banjo connection suitable for 40/31.50 KVA DG Set
Supply only air filter suitable for 40/31.50 KVA DG Set
Supply only fuel filter suitable for 40/31.50 KVA DG Set
Supply only coolant fluid of make as approved by Engr-in-Charge suitable for radiator of DG set of any capacity/make complete all as specified and directed.
Supply only Engine oil/ lubricant, 20 W 40 grade or any other grade as recommended by OEM of Engine or Engr-in-Charge suitable for DG set of any capacity and any make, complete all as specified and directed.
Supply and fix in repair of lead acid battery 12 volt, 150 AH heavy duty maintenance free incl initial charged complete all as specified and directed.
Replacement of old damaged battery lead with new battery lead of copper conductor of 50 Sqmm cross-sectional area, multistranded, single core, PVC insulated fitted with lugs/ terminals at one end and brass terminals at other end, complete all as specified and directed. (Note: The battery lead replaced shall have colour as per colour coding. The brass terminal provided on battery end side shall be measured & paid separately.)
Taking out old defective repairable injection nozzle from existing DG set of 82.5 KVA capacity and transport to workshop for any type of repair, overhauling and calibration including installation back to same DG set, including testing, complete all as specified and directed.
Taking out old defective repairable injection nozzle from existing DG set of 62.5 to 30 KVA capacity and transport to workshop for any type of repair, overhauling and calibration including installation back to same DG set, including testing, complete all as specified and directed.
Cleaning of fuel tank of any capacity for DG set 82.5 KVA to 30KVA any type(inbuilt in canopy/ separate storage tank) DG Set by removing all silt /dirt/ all residual, foreign particles any type etc, removing any type of leakage by welding/brazing and writing date of cleaning with synthetic enamel paint complete all as specified and directed.
Taking out FIP from DG set of 30/40 KVA capacity, transportation to manufacturer's authorised service centre and recallibration & transpotation to same or other location as directed incl. replacement of all necessary spare parts such as delivery valves , plunger , 'O' ring spring etc complete all as specified and directed.
Taking out FIP from DG set of 62.5/82.5 KVA capacity, transportation to manufacturer's authorised service centre and recallibration & transpotation to same or other location as directed incl. replacement of all necessary spare parts such as delivery valves , plunger , 'O' ring spring etc complete all as specified and directed.
Repair and maintenance of DG set control panel, checking all the electrical connections of engine/alternator/ control panel instruments ie lub oil, pressure gauge,temprature gauge, ameter, battery , volt meter,ac volt meter,ac ameter, frequecny meter etc, calibration of modules microprocessor, tightening all the connection, replacement of defective wiring & cable and lugs of DG set of cap 30KVA to 63KVA DG set and replacing of the following parts spare partsshall be measured and paid separately under respective items as supply only as under :-
Supply only Voltmeter digital/analog type 96x96mm having range as per existing
Supply only Ammeter digital/analog type 96x96mm having range as per existing
Taking down radiator of DG set of cap 40/62.5 KVA and repairing/cleaning and refixing the radiator , including any welding (if leakage is noticed) complete all as specified and directed
Supply and fix in repair for bus bar chamber outdoor type, comprising of encloser made out of 3.15 mm thick CRCA sheet of size 0.6 X 0.50 X 0.35 mtr , powder coated with 04 Nos of aluminium bus bar of 100 Amps 1100 volts grade, fixed and including insulators with provn of 04 X incoming/outgoing cable hole and provided with rubber bushes with provn of earth connection duly provided with angle iron frame stand of size 40x40x5 mm with 40 cm grouted in PCC and 40 cm above the ground level in and including with necessary PCC and earth work complete all as specified and directed.
Dismantling and Taking down old U/S PCC LT/Steel pole of any size including earth work , removing the PCCetc complete all as specified and directed
Errecting of steel tubular/PCC LT pole retrieved against the respective item as above complete where required and planted in the earth in PCC (1:3:6) type C2 using 40 mm graded stone aggregate in foundation all as specified and directed. Note :- Earth work and PCC work shall be measured and paid separately.
Dismantling insulators any type, any size and depositng to the same to the MES store yard.
Taking out the old unsv LT/AB cable any type any size 50 Sq mm X 3.5 core to 16Sq mm X 3.5/4 core in any position from pole in any height or passing through pipe heavy duty electric cable all as specified and directed.
Standard engineers
KALSI CONSTRUCTION CO
SHUSHANT ASSOCIATES
M/S PRAJAPATI ENGINEERS
Ms International Engineers
kailu construction co
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .