| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.9 LAccepted-AOC 337 B ROAD NO 04 ASHOK NAGAR RANCHI 834002 JHARKHAND | RANCHI | JHARKHAND | 834002 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹51.6 L+₹93,794.25 (1.85%)Rejected-Finance VIKASH NAGAR ROAD NO 1 NEAR GAUSHALA RAMGARH CANTT JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹53.9 L+₹3.2 L (6.37%)Rejected-Finance 1446 ELITE ENTERPRISES NORTH SOLAPUR NEAR SUSHIL MARATHI SCHOOL SOLAPUR MAHARASHTRA 413004 | SOLAPUR | MAHARASHTRA | 413004 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹54.0 L+₹3.4 L (6.69%)Rejected-Finance KRISHNA NAGAR BOOTY RANCHI 835217 | RANCHI | JHARKHAND | 835217 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹54.8 L+₹4.2 L (8.27%)Rejected-Finance D 9 NETAJI NAGAR KANTATOLI COLONY RANCHI 834001 | RANCHI | RANCHI | JHARKHAND | 834001 | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
6 Dec 2021, 6:00 pmClosed
GE Dipatoli
GARRISON ENGINEER MILITARY ENGINEER SERVICES DIPATOLI CANTT P.O. HOTWAR RANCHI - 834012
REPAIR / MAINT OF DRAIN, BOUNDARY WALL, FENCING, GATES, HARD STANDING ETC FOR MD AND OTM ACCN OF CENTRAL ZONE IN AGE B/R-II AREA UNDER GE DIPATOLI MIL STATION
2021_MES_485505_2
8000/1762/E8
Open Tender
Civil Works
Item Rate
180 days
GE Dipatoli
Class D
Category a(i)
8 documents required · 8 mandatory
₹500
Yes
GE Dipatoli
₹96,000
Yes
31 Dec 2021
24 Nov 2021
8 Dec 2021
24 Nov 2021
6 Dec 2021
1 Dec 2021
Amount
Dismantling posts or struts (wood, steel or RCC) any section including taking out embedded portion and making good disturbed ground/portion, post embedded in natural ground etc complete all as specified and as directed.
Excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cu.m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and as directed.
M&L for PCC (1:2:4) type B-2 (using 40 mm graded stone aggregate) as in foundation, filling and packing of fencing post or other works complete all as specified and as directed.
S&F mild steel work as in hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars for doors, balusters, nosing to steps including embeding in concrete and screws etc wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron filets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F 5 to 10 mm dia mild steel screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm but n. exc. 10 cm long complete all as specified and as directed.
S&F chimney bars (straight or camber), bearing bars; tongues or water bars for window frames, window guard bars, bars for chain link fencing plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc and similar articles conforming to Fe-290 Gde E-165 complete all as specified and directed.
Dismantling fencing wire mesh, any type or in any situation complete all as specified and as directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and as directed.
Supply only chain link MS galvanised fencing, any size or type complete all as specified and as directed.
Supplied and fixed in repair galvanized 2 strands steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75mm spacing and straining and fixing to any type of standared rails straining bolts including securing or tying at crossing with and provision of galvanized mild steel wire , staples or steel pins etc complete all as specified and as directed. Note:- Each line wire to be measured.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth not otherwise described and apply two coats of synthetic enameled paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Demolition of cement concrete in ground floors and paving n.exc 15cm thickness but above ground level complete all as specified and as directed.
Surface excavation n. exc 30 cm deep and averaging 15cm deep and getting out in soft/loose of soil complete all as specified and as directed.
M&L for hardcore of gauge n exc. 63 mm of broken stone or boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and well rammed to a true surface complete all as specified and as directed.
M&L for PCC (1:4:8) type D-2 using 40 mm graded stone aggregates as in foundation and sub base filling and mass concrete complete all as specified and as directed.
M&L for 100mm thick cement concrete (1:2:4) type B-2, (using 40mm graded stone aggregate), surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, dry complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block glossy finish, with gray cement and pigment, any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade with and including over 50mm thick sand filling complete all as specified and as directed.
M&L for chequered cement concrete tiles of size (20cm x 20cm) x 25mm thick glossy finish, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment, over and including 15 mm screed bed in cement mortar (1:4) complete all as specified and as directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specially provided etc complete all as specified and as directed.
M&L for providing pre cast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregates) & set in CM (1:4) as in cover slabs for drain, manholes etc. including necessary use and waste of form work complete all as specified and as directed.
Excavation in trenches, n.exc. 1.5m wide and n.exc. 1.5 m in depth for foundation and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layer not exceeding 25cm etc complete all as specified and as directed.
Removal of excavated materials not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points etc complete all as specified and directed.
Demolition of brick work masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and pre-cast concrete articles complete all as specified and as directed.
M&L for brick work with subclass “B” Old size bricks, straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4), finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of old plastered surfaces of walls and applying one coat of cement base paint to external surfaces of walls complete all as specified and as directed.
M&L for preparation of newly plastered surface of walls and applying two coats of cement base paint over a coat of primer to external surfaces of walls complete all as specified and as directed.
M&L for cement concrete (1:2:4) type B2 (using 40mm graded stone aggregates) as in surface channels and drain complete all as specified and as directed.
M & L for PCC (1:2:4) type B1 (using 20mm graded stone aggregates) for fixing hold fast/coping or similar works complete all as specified and as directed.
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms, moulds, mitred/stopped ends etc complete all as specified and as directed.
M&L for concrete bed to drain pipes 300 mm bore of pipe including packing under and completely surrounding pipes with concrete after they are laid and tested in cement concrete (1:3:6) type C2 complete all as specified and as directed.
M&L for reinforced concrete pipes 300mm bore, class NP2, laid and jointed with collars complete all as specified and as directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits ( if any) of foundation and plinth beams; and similar work; vertical or to batter surfaces finished fair in forms complete all as specified and as directed.
Use and waste of Formwork to sides of Square, rectangular or polygonal pillars, posts, struts, piers, columns and stanchions surfaces finished fair as per clause 4.11.16.2 (a) of SSR Part I complete all as specified.
M&L for RCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in columns, pillras etc. complete all as specified and as directed.
M&L for RCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under reamed piles and mass concrete complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including, cranking bending, spirally for hooping ends and binding with mild steel wire (annealed) not leas than 0.9 mm dia or securing with clips quality confirming to Fe 410-S or Fe-410-0 complete all as specified and as directed.
S&F mild steel TMT bar 6 to 8 mm dia as in stirrups cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) complete, including fixture and fittings such as swithes, ceiling roses, pendants, regulators, Sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit at site and making good disturbed surfaces of walls, floors, roofs etc complete all as specified and as directed.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls, floors, roofs etc complete all as specified and as directed.
Taking down old/unserviceable MCB DB SPN any capacity by disconnection of electric connection including MCBs, Isolators, etc and making good to disturbed surface complete all as specified and as directed.
Taking down Old/ Unserviceabl MCB DBs TPN / Main Switches by disconnection of electric connection including old unserviceable MCCBs, MCBs, isolators etc and making good to distrubed surface complete all as specified and directed.
M&L point wiring for One light/Fan point controlled by one five amps one way single pole switch complete with 1.5 sqmm, single core, multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn through PVC concealed conduit pipe med grdae 20/25 mm on wall/ceiling, including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes 1.6 mm thick, chromium plated screw /Modular plate with frame and modular concealed GI sheet metal boxes ( 16 Gauge) as suitable size for mounting of switch & scoket including 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: The rate quoted is deemed to be included for Penolic sheet (Hylem) and concealed GI sheet metal boxes, modular plate with frame, cutting of hylem sheet for fixing of switch and scoket including cutting chases etc in wall and making good to disturbed surface and matching with existing wall, ceiling surfaces.
All as per Ser item No 47 here-in-before but one 3 Pin Socket out let 5 Amps on the same board complete all as specified and directed.
All as per Ser item No 47 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board complete all as specified and directed.
All as per Ser item No 47 here-in-before but one bell/buzzer point controlled by one push button on the independent board complete all as specified and directed.
All as per Ser item No. 47 here - in - before but one light point controlled by two 2 - way switches,with wire 1.5 Sqmm size complete all as specified and directed.
All as per Ser item No 47 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly complete all as specified and directed.
M&L point wiring for One light/Fan point controlled by one five amps one way single pole switch complete with 1.5 sqmm, single core, multi stranded copper conductor PVC insulated and unsheathed FRLS cable 1100 Volts grade, drawn through PVC casing / caping 20/25 mm on wall/ceiling, including replacement by new 3 mm thick phenolic laminated sheet top covers and sunk type CI/steel terminal boxes 1.6 mm thick, chromium plated screw /Modular plate with frame and modular concealed GI sheet metal boxes ( 16 Gauge) as suitable size for mounting of switch & scoket including 1.5 sqmm size pvc insulated unsheathed copper conductor to common earth and connecting to earth dolly complete all as specified and directed. Note: The rate quoted is deemed to be included for Penolic sheet (Hylem) and concealed GI sheet metal boxes, modular plate with frame, cutting of hylem sheet for fixing of switch and scoket including cutting chases etc in wall and making good to disturbed surface and matching with existing wall, ceiling surfaces.
All as per Ser item No 53 here-in-before but one 3 Pin Socket out let 5 Amps on the same board complete all as specified and directed.
All as per Ser item No 53 here-in-before but one 3 Pin Socket out let 5 Amps on the independent board complete all as specified and directed.
All as per Ser item No 53 here-in-before but one bell/buzzer point controlled by one push button on the independent board complete all as specified and directed.
All as per Ser item No.53 here - in - before but one light point controlled by two 2 - way switches,with wire 1.5 Sqmm size complete all as specified and directed.
All as per Ser item No 53 here-in-before but point wiring with 2.5 sqmm for 15 Amp socket out let & provision of earth wire 2.5 sqmm connected to common eart dolly complete all as specified and directed.
S&F Switch Piano type 2 way switch 5 amp 230 v complete all as specified and as directed.
Supply and fix Switch Piano type, single pole, one way 5 Amp complete all as specified & directed.
S&F Switch piano type , single pole , one way15 Amps complete all as specified and directed.
S&F Socket out let 2-in-1 2/3 pin 5 Amps complete all as specified and directed .
S&F Socket outlet 2-in-1, 3 pin, 5 and 15 amps, flush type complete all as specified & directed.
S&F in replacement electric Bell, ding dong type AC 230 Volt single pole complete all as specified and as directed.
S&F in replacement Bell push 5 Amps for electric Bell/Buzzer, AC 230 Volt single pole complete all as specified and as directed.
S&F Ceiling rose, 3 terminal PVC/polycarbonate complete all as specified and directed.
S&F 120 w, electronic fan regulator Rotary step type 240 Volts single phase, 50 Hz complete all as specified and as directed.
M&L for Angle lamp holder (metal ring), PVC /Polycarbonate type with back plate complete all as specified and directed at site.
S&F 10 Amp 1 Way modular switch, 240 volts one module complete all as specified and directed. Make : Anchor Roma cat part No 21011 or equivalent as per list of makes.
S&F 10 Amp 2 Way modular switch, 240 volts one module complete all as specified and directed at site. Make : Anchor Roma cat part No.21022 or equivalent as per list of makes.
S&F 10 Amp modular bell push switch, 240 volts one module complete all as specified and as directed. Make : Anchor Roma Cat part No.21044 or equivalent as per list makes.
S&F modular switch 20 Amp 1 way switch one module, 240 volts complete all as specified and directed at site. Make : Anchor Roma cat part No.21066 or equivalent as per list of makes.
S&F modular socket 10 Amp multi socket for Cell phone pin or 2 pin & 3 Pin, 240 volts, two module complete all as specified and as directed. Make : Anchor Roma cat part No.30373 or equivalent as per list of makes.
S&F modular socket one way 20 Amp & 10 Amp Twin Socket (heavy duty), 240 volts two module complete all as specified and as directed. Make : Anchor Roma Cat part No.30828 or equivalent as per list of makes.
S&F regulator modular step type one way 220 volt two module complete all as specified and as directed. Make : Anchor Roma Cat part No.30828 or equivalent as per list of makes.
S&F TV socket modular one module complete all as specified and as directed. Make : Anchor Roma Cat part No.21157 or equivalent as per list of makes.
S&F telephone socket modular one module complete all as specified and as directed. Make : Anchor Roma Cat part No.20857 or equivalent as per list of makes.
S&F in replacement of modular USB Charger complete all as specified and as directed. Make : Anchor Roma Cat part No.20460 or equivalent as per list makes.
S&F in replacement blanking plates for covering of MCCB DB open space complete all as specified and directed at site. Make : Anchor Roma cat part No.21598 or equivalent as per list of makes.
S&F in repacement switch socket combination 2 in 1, 3 pin 5 and 15 amp flush type as per existing model and size complete all as specified and directed at site.
S&F in repacement switch socket combination 2 in 1, 5 pin 5 amp flush type as per existing model and size complete all as specified and directed at site.
S&F in replacement of sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 20 Amps to 32 Amps complete all as specified and directed at site. Make-Havells Cat part No. DHDPUSN020/DHDPUDP020 or equivalent as per list of makes.
M&L for submain complete with 2x1.5 sqmm, single core, multi stranded copper conductor FRLS PVC insulated and unsheathed cable 1100 Volts grade, drawn in with and including PVC concealed conduit 20/25 mm dia as per site requirement along walls/ceiling etc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire(Phase red colour,neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surface conduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor) be measured as one length)
Description all as per ser item No.83 here-in-before but 2 x 2.5 sqmm and 1 x 2.5 sqmm for earth wire complete all as specified and as directed.
Description all as per ser item No. 83 here-in-before but 2 x 4 sqmm and 1 x 4 sqmm for earth wire complete all as specified and as directed.
Description all as per ser item No. 83 here-in-before but 2 x 6 sqmm and 1 x 6 sqmm for earth wire complete all as specified and as directed.
M&L for submain complete with 2x1.5 sqmm, single core, multi stranded copper conductor FR PVC insulated and sheathed cable 1100 Volts grade, drawn in with and including PVC casing / caping 20/25 mm dia as per site requirement along walls/ceiling etc including 1.5 sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and as directed. Note:- (i) all three wire (Phase red colour, neutral black colour and earth wire green colour) should be run through for each individual circuit from the DBs (ii) painting over surface conduit to be done to match with walls/ceiling existing surfaces. (iii) Two run of wire (phase & neutral) and one run of wire (earth conductor) be measured as one length)
Description all as per ser item No. 87 here-in-before but 2 x 2.5 sqmm and 1 x 2.5 sqmm for earth wire complete all as specified and as directed.
Description all as per ser item No. 87 here-in-before but 2 x 4 sqmm and 1 x 4 sqmm for earth wire complete all as specified and as directed.
Description all as per ser item No. 87 here-in-before but 2 x 6 sqmm and 1 x 6 sqmm for earth wire complete all as specified and as directed.
M&L fot fixing PVC Casing/ caping 20/25 mm on wall/ceiling, including replacement of old unserviceable PVC casing /caping, for existing old serviceable point wiring of 1.5mm,/2.5mm,/4mm /6 sqmm, existing wiring/Submain wiring drawn through new PVC Casing caping/conduit on wall/ceiling, including replacement complete all as specified and as directed. (Note:- The rate quoted is deemed to be included for taking down of unserviceable PVC Casing caping/ conduit including cutting & fixing charges & making good to disturbed surface matching with existing surfaces.)
Supply and fix MCB DB SPN 4 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site. Make -Havells Cat part No.DHDPSHODRW04 or equivalent as per list of makes.
Supply and fix MCB DB SPN 8 way double door with metal door suitable for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed at site. Make -Havells Cat part No.DHDPSHODRW08 or equivalent as per list of makes.
Supply and fix MCB DB SPN 12 way double door with metal door suitabl for housing of MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directedcomplete all as specified and directed at site. Make -Havells cat part No.DHDPSHODRW12 or equivalent as per list of makes.
Supply and fix MCB DB TPN 4 way double door with metal door suitable for Provision of incommer MCCB and out going MCBs grouting/flush in wall and making good to disturbed surfaces incl fixing material/accessories complete all as specified and directed. Make -Havells Havells cat part No.DHDLVDRWGOFO04 or equivalent as per list of makes.
S&F in replacement of MCCB 3 Pole 415 volt 100 amp 50 Hz adjustable type with breaking capacity 10 kA with thimbles / lugs and nut bolt complete all as specified and directed.
S&F in replacement of MCCB 3 Pole 415 volt 63 amp 50 Hz adjustable type with breaking capacity 10 kA with thimbles / lugs and nut bolt complete all as specified and directed.
S&F in replacement of MCCB 4 Pole 415 volt 100 amp 50 Hz adjustable type with breaking capacity 25 kA with thimbles / lugs and nut bolt complete all as specified and directed.
S&F in replacement of MCCB 4 Pole 415 volt 63 amp 50 Hz adjustable type with breaking capacity 25 kA with thimbles / lugs and nut bolt complete all as specified and directed.
S&F in replacement of MCB SP 6 to 32 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. Make Havells cat part No. DHMGCSPF006-32 or equivalent as per list of makes.
S&F in replacement of MCB SP 63 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles. Make -Havells cat part No.DHMGCSPF063 or equivalent as per list of makes.
S&F in replacement of MCB DP 40 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles. Make -Havells cat part No.DHMGCDPF040 or equivalent as per list of makes.
S&F in replacement of MCB DP 63 Amps 'C' Series 10 KA fixing in DBs, connecting with bottel type copper thimbles complete all as specified and directed. Make -Havells cat part No.DHMGCDPF063 or equivalent as per list of makes.
S&F in replacement of isolator DP 40 Amps 'C' series fixing in DBs, connecting with bottle type copper thimles complete all as specified and directed.
S&F in replacement of isolator DP 63 Amps 'C' series fixing in DBs, connecting with bottle type copper thimles complete all as specified and directed.
S&F in replacement of isolator TPN 40 Amps 'C' series fixing in DBs, connecting with bottle type copper thimles complete all as specified and directed.
S&F in replacement of isolator DP 63 Amps 'C' series fixing in DBs, connecting with bottle type copper thimles complete all as specified and directed.
S&F in replacement of isolator TPN 80 Amps 'C' series fixing in DBs, connecting with bottle type copper thimles complete all as specified and directed.
S&F in replacement of isolator TPN 100 Amps 'C' series fixing in DBs, connecting with bottle type copper thimles complete all as specified and directed.
S&F in replacement of LED tube light fitting 1x18/20 watt 230 Volt decorative ultra slim linear LED Lighting with extruded polycarbonate, including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make : Cat/part No. LUMILINEPLUSBS18WLED865SPCSS of Havells or equivalent in philips/Wipro/Jaguar.
S&F in replacement of Lienear and compact 9 watt LED mirror light with decorative end caps plocarbonate body and ribbed opal diffuser including 2/3 core flexible copper wire with flexible pipe ceiling rose to light fittings complete all as specified and as directed. Make : Cat/part No. LUMILINEBS9WLED865SPCWH of Havells or equivalent in philips/Wipro/Jaguar.
S&F in replacement of environmental friendly ultra modern, energy saving, surface mounted, decorative oval plastic bulk head LED light fittings 10 watt capacity comprising of high brightness LEDs IP 54 protection with all accessories including connecting up with 2/3 core twisted flexible copper conductor cable complete all as specified and as directed. Make : Philips cat part No. CWLL01V109XX or equivalent in Havells / HPL.
S&F in replacement of LED batten tube light fitting 20/22 watt 230 Volt decorative Endura Linear Neo LED Light fitting with aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver.Including all internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed at site. Make : - Cat/part No:-ENDURALINEARENEOBS22WLED830SPCWH of Havells or equivalent in Philips/HPL/C&S
S&F in replacement Decorative wall light fitting CT2 10 W made up of polycarbonate,complete all as specified and directed at site. Make : Havells Cat Part No.LHDL03160099 or equivalent in philips /Wipro
Supply and fix in replacement 'JUNO' integral post top lantern copper dust painted cast aluminium spigot,spun aluminium canopy with clear acrylic cover with 20 Watt LED lamp including all accessories such as Bracket, GI Pipe and prewired complete all as specified and directed at site. Make : Jaguar cat part No. 340.33.NGG or equivalent in Havells/ HPL
Supply and fix in replacement 'JUNO' integral post top lantern copper dust painted cast aluminium spigot,spun aluminium canopy with clear acrylic cover with LED lights including all accessories such as Bracket,GI Pipe and prewired complete all as specified and directed at site. Make : Havells cat part no. CORALMINIPT1 WLED757PSYMTOPC or equivalent in C&S/ PHILIPS/L&T
S&F in replacement of building LED security light fitting 35 Watt in aluminium pressure die cast aluminium housing with high power LED as lightning sourse and lens embedded PC Cover having IP 65 protection and impect resistance of IK07 with 10 KV Built in super protection device. luminaire with high power LED as light source including suitable size of GI bracket fixed with two Nos GI clamp nut,bolt,washer etc complete all as specified and directed at site.Make : Havells Cat No:-ENDURACITYLITEPLATPLUSSL35WLED 757SASYBOPC or equivalent in Philips/C&S
S&F in replacement of Ultra slim LED panel tube light fitting 36 watt 230 Volt made from extruded aluminium housing frame (recesss/pendant) 2' x2' Complete with all accessories internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed at site. Make : Cat/part No LSVR01S036XN of Jaguar/ /Havells cat part No.LHEWBPP7PL1w036/ Indus plus of HPL
M&L for repair/greasing of ceiling fan of any size sweep single phase celing fan of any size opening from any height or any locations, fan opening from hook, clamp & refixing the same after cleaning and greasing with requird necessary cutting/ welding/ grinding job or required store such as nuts, bolts, washer and suitable length mild steel/ down rod duly making holes etc complete all as specified and as directed.
S&F in replacement PVC ventilating air fan single phase 250 mm sweep complete with louver shutter and including making hole of suitable size, fan base after cutting of brick/stone wall of suitable size of water proof ply wood complete all as specified and directed. Make : Havells model ventil Air - DB or equivalent as per list of makes.
S&F in replacement PVC ventilating air fan single phase 300 mm sweep complete with louver shutter and including making hole of suitable size, fan base after cutting of brick/stone wall of suitable size of water proof ply wood complete all as specified and directed. Make : Havells model ventil Air - DB or equivalent as per list of makes.
Supply, Laying on replacement, connecting, testing and commissioning of XLPE LT UG cable of size 35 sqmm 3 1/2 core PVC insulated and sheathed armoured heavy duty cable 1100 V grade with aluminium conductor cable complete all as specified and as directed. Note:- Excavation, earthwork and protection of cable shall be measured and paid seperately.
Excavation in trenches in loose/soft soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface complete all as specified and as directed.
Removing excavated surplus (soil) obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and as directed.
Supplying and spreading dry river sand for cable cushioning in trenches complete all as specified and as directed. Note:- Punned down thickness shall be considered for measurement. .
Supply and lay kiln burnt bricks sub class ‘B’ old size laid dry in trenches across the cable protection complete all as specified and as directed.
M &L for GI Earthing complete with GI earth plate electrode (60cm x 60cm) x6 mm thick buried directly in ground vertically to size of depth not less than (0.90x 0.90)m x 2.25 mtr below ground level with top edge of the plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earth wire of size 8.00 mm dia 7.5 mtr long by means of brazing nuts, bolts, check nuts, & washers, testing of completion (drawn in earth lead protection pipe light gade GI of size 15 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 5 of SSR Part - I connected to earthing lead with Main switch/main control board, filling with charcoal dust 200 Kg, and common salt 100 KG, including necessary excavation and earth work in any type of soil, perforated watering pipe, funnel with wire mesh, earth lead protection pipe light grade, PCC chamber (1:3:6) type C1 (for even finish on both the faces) and RCC cover (1:2:4) Type B1, (450 x450)mm x 50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod complete all as specified and as directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EIC. Note : i) Earthing test must be carried out in presence of Engr-in-Charge/JE E&M. ii) The earthing result not more than 2 Ohms or desired earth resistance value. iii) Megger required for testing will be be provided at site by the contractor. iv) Contractor shall submit earth resistance testing report before submission of RAR.
M/S KAMLESHWAR SINGH
Elite Enterprises
M/S OMANIA ENTERPRISES
M/s Kundu Enterprises
M/S SURYA BUILDERS
M/s Ray construction
m/s sheo kumar singh & sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .